SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW



Similar documents
SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX Gb/s Fiber Channel

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

8.5Gb/s SFP+ Fibre Channel Optical Transceiver

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX

4.25Gbps SFP Optical Transceiver, 30km Reach

Product Specification 10Gb/s BIDI SFP+ Transceiver

10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX

155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

155Mbps DFB SFP Optical Transceiver, 120km Reach

LONGLINE 2km XFP Optical Transceiver

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

XFP Optical Receiver, 80km Reach

1.25Gbps GBIC Optical Transceiver, 20km Reach

Product Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL

LONGLINE 40km XFP Optical Transceiver

DWDM SFP Series. Power budget* (note2) Laser

DWDM SFP Series. Power budget* (note2) Laser

Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics

1000BASE-BX-OLT Transceiver

SFP-GIG-SX 1000BASE-SX, Jusqu à 550 mètres de distance opérationnelle, Longueur d onde Laser 850nm, Fibre Multimode (MMF), SFP Optique Insérable

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

Intel Ethernet SFP+ Optics

GPON OLT Optical Transceiver SFP Module RTXM Features

10GBASE-LR XFP Optical Transceiver AXM752

X2 LR Optical Transponder, 10Km Reach

Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

10/100/1000BASE-T SFP Transceiver

Product Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL

10GBASE -LRM, 220m Reach GX LRMC

10GBASE-SR XFP Optical Transceiver AXM751

GBIC CWDM 40km Part no:

SO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

Dual Fiber SFP Series

155Mbps ATM-Single Mode Transceiver

PART NUMBER INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE

EPON ONU Optical Transceiver SFF Module

Part No. Data Rate Wavelength Interface Temp. DDMI

Product Specification ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx

Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet

Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description

SFP Copper Transceiver 10/100/1000Base-T

RoHS compliant 1310 nm multi-mode Transceiver (2 km) 1x9, ST Duplex Plastic Connector, 3.3 V 155 Mbps ATM/ Fast Ethernet

SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

Enabling the Business Continuity & Change the way business communicates

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC

Data Sheet. HFBR-0600Z Series SERCOS Fiber Optic Transmitters and Receivers

Features. Modulation Frequency (khz) VDD. PLL Clock Synthesizer with Spread Spectrum Circuitry GND

Application Note 5016

Un-cooled Multimode Pump Laser Module for Telecom Applications

Dispersion penalty test 1550 Serial

3.3V, 2.7Gbps SDH/SONET LASER DRIVER WITH AUTOMATIC POWER CONTROL

it4036f 120-ps Wideband Phase Delay Description Features Device Diagram Timing Diagram

DS1307ZN. 64 x 8 Serial Real-Time Clock

ICS SPREAD SPECTRUM CLOCK SYNTHESIZER. Description. Features. Block Diagram DATASHEET

Photolink- Fiber Optic Receiver PLR135/T1

Fiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V

Cisco SFP Optics for Gigabit Ethernet Applications

BF15U REV DESCRIPTION DATE APPROVED 2 Preliminary 1/7/2016 RAS/MF

High-Speed, Low r ON, SPST Analog Switch (1-Bit Bus Switch)

ICS379. Quad PLL with VCXO Quick Turn Clock. Description. Features. Block Diagram

DG2302. High-Speed, Low r ON, SPST Analog Switch. Vishay Siliconix. (1-Bit Bus Switch with Level-Shifter) RoHS* COMPLIANT DESCRIPTION FEATURES

VITESSE SEMICONDUCTOR CORPORATION. 16:1 Multiplexer. Timing Generator. CMU x16

Description. Dimensions. Features. precision works better

Wideband Driver Amplifiers

Prisma IP 10 GbE VOD Line Card

Accurate Loss-of-Signal Detection in 10Gbps Optical Receivers using the MAX3991

11. High-Speed Differential Interfaces in Cyclone II Devices

SPREAD SPECTRUM CLOCK GENERATOR. Features

INTEGRATED CIRCUITS. 74LVC08A Quad 2-input AND gate. Product specification IC24 Data Handbook Jun 30

Cold-Junction-Compensated K-Thermocoupleto-Digital Converter (0 C to C)

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

HT9170 DTMF Receiver. Features. General Description. Selection Table

Spread-Spectrum Crystal Multiplier DS1080L. Features

Golden test for dispersion penalty 1550 Serial

DS1621 Digital Thermometer and Thermostat

2 TO 4 DIFFERENTIAL PCIE GEN1 CLOCK MUX ICS Features

DS1621 Digital Thermometer and Thermostat

Methode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly.

V CC TOP VIEW. f SSO = 20MHz to 134MHz (DITHERED)

ICL V Powered, Dual RS-232 Transmitter/Receiver. Description. Features. Ordering Information. Applications. Functional Diagram.

High-Speed, 5 V, 0.1 F CMOS RS-232 Driver/Receivers ADM202/ADM203

VS-500 Voltage Controlled SAW Oscillator

LB1836M. Specifications. Monolithic Digital IC Low-Saturation Bidirectional Motor Driver for Low-Voltage Drive. Absolute Maximum Ratings at Ta = 25 C

7 OUT1 8 OUT2 9 OUT3 10 OUT4 11 OUT5 12 OUT6 13 OUT7 14 OUT8 15 OUT9 16 OUT10 17 OUT11 18 OUT12 19 OUT13 20 OUT14 21 OUT15 22 OUT16 OUT17 23 OUT18

+5 V Powered RS-232/RS-422 Transceiver AD7306

4 OUTPUT PCIE GEN1/2 SYNTHESIZER IDT5V41186

1000 BASE-X SFP. Key Features DATA SHEET HIGHLIGHTS 1000BASE-SX 1000BASE-LX 1000BASE-ZX 1000BASE BX-D*

Transcription:

Product Features Compliant with IEEE Std 802.3-2005 10G Ethernet 10GBase-LR/LW Electrical interface specifications per SFF-8431 Management interface specifications per SFF-8431 and SFF-8472 SFP+ MSA package with duplex LC connector Uncooled 1310nm DFB Laser Up to 10.3Gb/s bi-directional data links Single +3.3V power supply Class 1 laser safety certified Operating temperature Options (Commercial) -5 o C to +70 o C (Industrial) -40 o C to +85 o C Up to 10km on 9/125µm SMF RoHS Compliant Applications 10G Ethernet 10GBASE-LR/LW 10G Fiber Channel 1200-SM-LL-L Descriptions SFP+ LR transceivers, according to Enhanced 8.5 and 10 Gigabit Small Form Factor Pluggable SFP+ Multi- Sourcing Agreement (MSA) SFF-8431 and SFF-8472, revision 10.4, are designed for 10G Ethernet serial optical data communication up to 10km on single mode fiber. They are compliant with IEEE Std 802.3-2005 10Gb Ethernet 10GBase-LR/LW and 10G Fiber Channel 1200-SM-LL-L. SFP+ LR offer commercial and industrial operating temperature options. Ordering Information Table 1. Ordering Information Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS SFP+ LR 1310nm DFB -8.2 ~ +0.5dBm PIN < - 14.4dBm 10km -5 ~ 70 o C Available Compliant SFP+LR ITEMP 1310nm DFB -8.2 ~ +0.5dBm PIN < - 14.4dBm 10km -40 ~ 85 o C Available Compliant

Pin Description Table 2. Pin Description Pin Name Function/Description Notes 1 VeeT Transmitter Ground 1 2 TX_Fault Transmitter Fault (LVTTL-O) - High indicates a fault condition 2 3 TX_Disable Transmitter Disable (LVTTL-I) High or open disables the transmitter 3 4 SDA Two wire serial interface Data Line (LVCMOS-I/O) (MOD-DEF2) 4 5 SCL Two wire serial interface Clock Line (LVCMOS-I/O) (MOD-DEF1) 4 6 MOD_ABS Module Absent (Output), connected to VeeT or VeeR in the module 5 7 RS0 Rate Select 0 Not used, Presents high input impedance - 8 RX_LOS Receiver Loss of Signal (LVTTL-O) 2 9 RS1 Rate Select 1 Not used, Presents high input impedance - 10 VeeR Receiver Ground 1 11 VeeR Receiver Ground 1 12 RD- Inverse Received Data out (CML-O) - 13 RD+ Received Data out (CML-O) - 14 VeeR Receiver Ground - 15 VccR Receiver Power - +3.3V - 16 VccT Transmitter Power - +3.3 V - 17 VeeT Transmitter Ground 1 18 TD+ Transmitter Data In (CML-I) - 19 TD- Inverse Transmitter Data In (CML-I) - 20 VeeT Transmitter Ground 1 Notes: 1. The module signal grounds are isolated from the module case. 2. This is an open collector/drain output that on the host board requires a 4.7KΩ to 10KΩ pull-up resistor to VccHost. 3. This input is internally biased high with a 4.7KΩ to 10KΩ pull-up resistor to VccT. 4. Two-Wire Serial interface clock and data lines require an external pull-up resistor dependent on the capacitance load. 5. This is a ground return that on the host board requires a 4.7KΩ to 10KΩ pull-up resistor to VccHost.

Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Table 3. Absolute Maximum Ratings Parameter Symbol Minimum Maximum Unit Storage Temperature T S -40 85 Relative Humidity RH 5 95 % Supply Voltage V CC -0.5 4.0 V o C Recommended Operating Conditions Table 4. Recommended Operating Conditions Parameter Symbol Min Typ Max Unit Operating Case Temperature T C -5 25 70 Supply Voltage V CC 3.135 3.3 3.465 V Data Rate - - 10.3125 - Gb/s o C Transceiver Electrical Characteristics Table 5. Transceiver Electrical Characteristics Parameter Symbol Minimum Typical Maximum Unit Module Supply Current Icc - - 290 ma - Power Dissipation P D - - 1000 mw - Transmitter Input Differential Impedance Z IN - 100 - Ω - Differential Data Input Swing V IN, P-P 180-700 mv P-P - TX_FAULT TX_DISABLE Receiver Notes Transmitter Fault V OH 2.0 - V CCHOST V - Normal Operation V OL 0-0.8 V - Transmitter Disable Transmitter Enable V IH 2.0 - V CCHOST V - V IL 0-0.8 V - Output Differential Impedance Z O - 100 - Ω - Differential Data Output Swing V OUT, P-P 300-850 mv P-P 1

Data Output Rise Time, Fall Time t r, t f 28 - - ps 2 RX_LOS Loss of signal (LOS) V OH 2.0 - V CCHOST V 3 Normal Operation V OL 0-0.8 V 3 Notes: 1. Internally AC coupled, but requires a external 100Ω differential load termination. 2. 20 80 %. 3. LOS is an open collector output. Should be pulled up with 4.7kΩ on the host board. Transmitter Optical Characteristics Table 6. Transmitter Optical Characteristics Parameter Symbol Minimum Typical Maximum Unit Notes Launch Optical Power Po -8.2 - +0.5 dbm 1 Center Wavelength Range λc 1260 1310 1355 nm - Extinction Ratio EX 3.5 - - db 2 Optical Modulation Amplitude OMA -5.2 - - dbm Spectral Width (-20dB) Δλ - - 1 nm - Side Mode Suppression Ratio SMSR 30 - - db - Transmitter and Dispersion Penalty TDP - - 3.2 db - Optical Return Loss Tolerance ORLT - - 12 db - Pout @TX-Disable Asserted P off - - -30 dbm 1 Eye Diagram IEEE Std 802.3-2005 10Gb Ethernet 10GBASE-LR compatible Notes: 1. The optical power is launched into 9/125µm SMF. 2. Measured with a PRBS 2 31-1 test pattern @10.3125Gbps.

Receiver Optical Characteristics Table 7. Receiver Optical Characteristics Parameter Symbol Minimum Typical Maximum Unit Notes Center Wavelength λc 1260 1310 1355 nm - Receiver Sensitivity (P avg ) S - - -14.4 dbm 1 Receiver Sensitivity (OMA) S OMA - - -12.6 dbm 1 Receiver Overload (P avg ) P OL 0.5 - - dbm 1 Stressed Sensitivity (OMA) - - - -10.3 dbm 2 Optical Return Loss ORL 12 - - db - LOS De-Assert LOS D - - -17 dbm - LOS Assert LOS A -30 - - dbm - LOS Hysteresis - 0.5 - - db - Notes: 1. Measured with PRBS 2 31-1 test pattern, 10.3125Gb/s, BER<10-12. 2. Comply with IEEE 802.3-2005.

SERDES IC SFP+ LR Recommended Host Board Power Supply Filter Network 0.1Ω 4.7μH VccT 0.1μF 22μF 0.1μF Host 3.3V 0.1μF 0.5Ω 4.7μH 22μF 0.1μF VccR SFP+ Connector SFP+ Module 0.5Ω Vee Figure 2. Recommended Host Board Power Supply Filter Network Recommended Application Interface Block Diagram Host Board SFP+ Module Vcc (+3.3V) VccT 4.7KΩ to 10KΩ TX Disable 4.7KΩ to 10KΩ TX Fault Serdata Out + 50Ω TD + Serdata Out - 50Ω TD - 100Ω Laser driver Serdata In + 50Ω RD + 100Ω Serdata In - 50Ω RD - Amplifier Vcc (+3.3V) 4.7KΩ to 10KΩ RX_LOS SDA SCL MOD_Abs RS0 RGND RS1 Figure 4. Recommended Application Interface Block Diagram

13.9 9.2 12.4 13.7 SFP+ LR Mechanical specifications 56.7 3.2 Unit:mm Figure 5. Outline Drawing

PCB layout recommendation Figure 6. PCB layout recommendation

For more information 47877 Willich / Germany Sales Hotline: +49 (0)391 563921 0 email: sales@globix-it.de web: