Definition AC Power Distribution

Similar documents
Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

Chapter 24. Three-Phase Voltage Generation

How To Wire A Three Phase, Single Phase, Wye Transformer

The generation and supply of electricity within the U.K is achieved through the use of a 3-phase system.

Services. Three Phase Service

Three-phase AC circuits

Three phase circuits

Three-Phase Electric Power Distribution for Computer Data Centers

(3 )Three Phase Alternating Voltage and Current

3-Phase AC Calculations Revisited

Buck - Boost Transformers

6/14/02 Chapter 2: Basic Electrical Power Fundamentals 1/6

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

DANGER! HIGH VOLTAGE HAZARD

THREE PHASE CIRCUITS

Lecture Notes ELE A6

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

Branch Circuit Calculations

Gates, Circuits, and Boolean Algebra

Electrical Drawings - Table of Contents

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

Rotary Phase Converters

Transformer circuit calculations

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

415V DISTRIBUTION FOR GREEN DATA CENTERS

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Extollo Communications. Home Electrical Wiring and Cross Phase Coupling Overview

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

ELECTRONIC POWER SYSTEMS

How To Select A Solid State Relay For A Three Phase Resistive Load

TSn SERIES Surge Protective Device

Inverter / Charger Installation General Operations and AC and DC Connections

WINDING RESISTANCE TESTING

Medium-voltage Transformers

The Fundamentals of Three-Phase Power Measurements. Application Note

Problem / Solution. The problem:

AC Generators. Basic Generator

Rule Fast Track Analysis for National Life Insurance Co.

TRANSFORMER LOSS COMPENSATION FOR METERMEN PRESENTED BY: MICHAEL K. BEARDEN

Current Transformers

Server Technology, Inc.

415V DISTRIBUTION FOR GREEN DATA CENTERS

Step Voltage Regulators

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

AC Power. by Prof. Dr. Osman SEVAİOĞLU Electrical and Electronics Engineering Department

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Fundamentals of Power

Unit 33 Three-Phase Motors

Short Circuit Current Calculations

FIT TIER 2 Application

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

BALANCED THREE-PHASE CIRCUITS

Introduction. Page 2 / 9

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

Earthing Guidance Notes

Power surges can also be generated by equipment in your facility such as:

Unified requirements for systems with voltages above 1 kv up to 15 kv

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

Electricity for the Entertainment Electrician Ef Technician

How To Test A Power Distribution Unit

EARTHING SYSTEM CALCULATION

Current Monitoring Kit

Corner-Grounded Delta (Grounded B Phase) Systems

Installation Instructions

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

Battery Backup for Grid-Tied PV Systems

How To Get A Power Line Extension

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

AC and DC Drive System Installation Information

SAMPLE OF THE STUDY MATERIAL PART OF CHAPTER 3. Symmetrical Components & Faults Calculations

Small Scale Renewable Energy Control Systems

ScottishPower Distribution Cables & Equipment. Metal Theft

User s Manual Before using the inverter, you need to read and save the safety instructions.

Application of Four-Pole Circuit Breakers within Data Centers

Chapter 7. DC Circuits

Understanding Delta Conversion Online "Power Regulation" - Part 2

Triplen Harmonics Mitigation 3 Phase Four-Wire Electrical Distribution System Using Wye- Zig-Zag Transformers

HM-W536 Install Guide

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

FW-X240 AUTO TRANSFORMER Installation Manual

Kirchhoff's Current Law (KCL)

I = V/r P = VI. I = P/V = 100 W / 6 V = amps. What would happen if you use a 12-volt battery and a 12-volt light bulb to get 100 watts of power?

Series and Parallel Resistive Circuits

Quick Connect. quick - simple - efficient.

Additional Solar System Information and Resources

EEL303: Power Engineering I - Tutorial 4

INSTRUCTION MANUAL MODEL PCD-88

Server Technology Inc.

The Basics of Solar Power for Producing Electricity An excellent place to start for those just beginning. The basics of solar power: 1000 W/m²

Refer installation of power supplies to qualified service personnel.

Beware; the Multiwire Branch Circuit

Measurement of Power in single and 3-Phase Circuits. by : N.K.Bhati

Transcription:

COMMON AC POWER DISTRIBUTION CONFIGURATIONS The input voltage needed to power electronic equipment is provided by the manufacture in the product specifications. Matching this requirement to the facility power available can often raise questions. This paper is intended to assist you in identifying the different power configurations that may be in your facility. SINGLE PHASE 120 Single Phase 120 often called house current is the AC power used in commercial buildings and houses to power lights and small appliances. The output voltage is 120Vac line to neutral (L-N). Line to neutral may also be called phase to neutral. There is both a 2 wire and a 3 wire configuration. The 2 wire configuration consists of and. This configuration is older and is being replaced by the 3 wire configuration which adds the earth ground connection. The grounded neutral conductor and ground provides a significant safety improvement. See Figure 1. Depending on the actual local power distribution standards, the single phase the voltage may be listed as 110Vac, 115Vac, 117vac or 120 Vac. Even with these stated nominal vales, variation do occur due to grid power demands, transformer losses, and voltage drops due to wiring impedances. Many low power Ametek power supplies can operate on single phase 120. 120 Vac L-N Figure 1 - Single Phase 120

Single Phase 120/240 Single phase 120/240 is commonly seen as the source for AC power to household cloths driers. It may also be called Split Phase 240. This configuration consists of 2 voltage legs that are 180 degrees apart. The voltage between the two legs (called phase to phase or line to line) is 240V and the phase to neutral voltage is 120V.The 120/240 notation identifies the phase to neutral voltage followed by the phase to phase voltage. Some list the phase to phase voltage first so it may also be called 240/120 single phase. See Figure 2. Medium power Ametek power supplies ( < 5 kw) will operate on this voltage configuration. 240Vac L-L Figure 2 Single Phase 120/240

3 onfigurations AC power is usually distributed in a facility in a 3-phase system consisting of 5 wires. Three of the wires are current carriers and are called phases. These 3 phases are 120 degrees out of phase from each other. The fourth wire is the neutral wire. The neutral wire will not have current flowing in it as long as the current in the three phases are matched. The 5th wire is. This system is commonly called a 3 phase wye because of the Y shape of the phases. A 3 phase Wye configuration is shown in Figure 3. Figure 3 - Typical 3 phase WYE Configuration

In the USA the most common configuration is 208Y/120. This indicates that line to line (L-L) voltage is 208Vac in a WYE configuration and the line to neutral (L-N) voltage is 120Vac. It is also sometimes designated 120/208Vac, 120/208WYE, 208/120 WYE, 4 wire WYE or 120/208Y. See Figure 4. Most Ametek supplies > 5 kw will operate on this configuration. Figure 4-208Y/120 Configuration For higher power capabilities another configuration in the USA is 480Y/277. In this case the line to line voltage is 480Vac in a WYE configuration and the line to neutral voltage is 277Vac. See Figure 5. This configuration is often an optional voltage for most AMETEK supplies 5 kw and larger. 480Vac L-L 277Vac L-N 277Vac L-N 480Vac L-L 480Vac L-L 277Vac L-N Figure 5 480Y/277 Configuration

Since each phase in a 3 phase wye configuration is 120 degrees from each other, the L-L voltage is not the algebraic sum of the L-N voltages but a vector addition. A quick method that can be used if the phase angles are 120 degrees apart is to use the L-N voltage multiplied by 3. V L-N 3 = V L-L (i.e. 120Vac 1.7333 = 208 Vac) V L-L 1.7333 = V L-N (i.e. 480Vac 1.7333 = 277 Vac) Another variation of the 4 wire WYE configuration is the 5 wire wye configuration that adds an wire which is usually connected to neutral at the circuit breaker panel. See Figure 6. Figure 6 208Y/120 5 wire configuration

3 Phase Delta Configuration Although the WYE configuration is the most common configuration there also is the Delta configuration. See Figure 7. In this configuration, there is no neutral. So the voltage is always a line to line measurement. V line = V phase (i.e. 208Vac = 208Vac) I line =?3? I phase (If the phase current is 50 Amps the line current is 1.733? 50 Amps = 86.6 Amps) One advantage of a Delta configuration is that it does not have a neutral and therefore if a phase winding should fail the phase voltage at the load will remain constant. 208VacL-L 208VacL-L 208VacL-L Figure 7 3 and 4 wire Delta Configuration

Open Wye Configuration There are other distributions that are not common but may be encountered. The first is the 3 phase open wye. See Figure 8. This configuration can be used to allow power to be maintained if a phase fails or is in need of maintenance. This would require using a standard 3 phase wye configuration made from 3 single phase transformers. If one of the phases needs to be taken off line for repair the remaining two transformers can be set up in an open wye configuration and continue to operate. When the third phase transformer is available again the three transformers can be reconfigured in a standard wye configuration. The open phase voltage equals the line voltage/2 and the phase current equals the line current. Power is half that of a 3 phase wye configuration. V phase = V line / 2 I phase = I line Vac P Vac L-L Figure 8 3-Phase Open Wye

3 Phase Open Delta Configuration The 3 phase Open Delta configuration would serve the same purpose as the open Wye configuration discussed above and like the open wye would also require using single phase transformers. In this configuration the phase voltage equals the line voltage and the load current equals the phase A and the phase B current. The power available from this configuration is 2/3 of a 3 phase Delta configuration. This configuration is sometimes called V configurations. V phase = V line I phase A = I phase B = I load B I L-N = 1.73 * I Vac L-L Vac L-N Figure 9 3 Phase Open Delta

240V Split Phase Delta The 240V Split Phase Delta or High Leg Delta is a modified 240Volt 4 wire Delta with one phase center taped to provide two phases with 120Vac and a High leg which provides 208Vac in addition to 240 Vac. With this configuration a single system can provide different voltages for a facility that supports offices and factory machinery. This configuration is also known as dog leg or stinger leg. See Figure 10. High Leg 120Vac 120Vac 208Vac 240Vac 240Vac 240Vac Figure 10-240V Split Phase Delta