Agilent 4339B/4349B High Resistance Meters



Similar documents
Agilent 4338B Milliohm Meter

Agilent 87421A/87422A Power Supply

The Next Generation in Automated Oscilloscope Test

Agilent P940xA/C Solid State PIN Diode Switches

Agilent E5063A ENA Series Network Analyzer

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent U2000 Series USB Power Sensors

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Agilent 8762/3/4A,B,C Coaxial Switches

1.5 GHz Active Probe TAP1500 Datasheet

Agilent Television Power Consumption Testing. Application Note

Agilent Automotive Power Window Regulator Testing. Application Note

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Handheld portable appliance testers

Agilent E6832A W-CDMA Calibration Application

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

W- Series. Features: WOB. Mechanical Data Case : Moulded plastic. Lead : Solder plated. Weight : 1.10 grams. Page <1> 15/07/08 V1.

High Voltage Power Supplies

PXI and AXIe Modular Instrumentation

Agilent U2000 Series USB Power Sensors

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Agilent U2000 Series USB Power Sensors

PXI and AXIe Modular Instrumentation

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

1.44 kw Programmable DC Power Supplies XLN Series

Agilent 4284A/4285A Precision LCR Meter Family

Physical Specifications (Custom design available.)

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Agilent E5100A Network Analyzer

PCI Express 1.0 (2.5 GT/s) Protocol Test

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

High Power Programmable DC Power Supplies PVS Series

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

802.11ac Power Measurement and Timing Analysis

TDA2822 DUAL POWER AMPLIFIER SUPPLY VOLTAGE DOWN TO 3 V LOW CROSSOVER DISTORSION LOW QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION

Diode, Schottky SMB/DO-214AA. Page <1> 24/04/08 V1.1. Dimensions Inches (Millimeters)

Agilent FieldFox Remote Viewer

Agilent Technologies 3000 Series Oscilloscopes

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Mobile Communications DC Sources W

Keysight Technologies How to Choose your MAC Lever. Technical Overview

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

TDA CHANNEL VOLUME CONTROLLER 1 FEATURES 2 DESCRIPTION. Figure 1. Package

HCF4056B BCD TO 7 SEGMENT DECODER /DRIVER WITH STROBED LATCH FUNCTION

HCF4001B QUAD 2-INPUT NOR GATE

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Accuracy counts! SENSORS WITH ANALOG OUTPUT

How To Build A Powerline Box Powerline Generator

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Make Better RMS Measurements with Your DMM

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series

PS25202 EPIC Ultra High Impedance ECG Sensor Advance Information

Cable Analysis and Fault Detection using the Bode 100

L293B L293E PUSH-PULL FOUR CHANNEL DRIVERS. OUTPUT CURRENT 1A PER CHANNEL PEAK OUTPUT CURRENT 2A PER CHANNEL (non repetitive) INHIBIT FACILITY

Agilent OSS access7 Signaling Meter

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

HCC4541B HCF4541B PROGRAMMABLE TIMER

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

STGW40NC60V N-CHANNEL 50A - 600V - TO-247 Very Fast PowerMESH IGBT

Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications

LF00AB/C SERIES VERY LOW DROP VOLTAGE REGULATORS WITH INHIBIT

DS 600. A contact free flux gate based current measurement sensor 600A rms

AN3353 Application note

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Research RF Sputtering Packages

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Application Note. Double click System tray icon after service started. Click start/continue button

Voltech DC1000. Precision DC Bias Current Source

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

LM337. Three-terminal adjustable negative voltage regulators. Features. Description

Agilent EEsof EDA.

ADJUSTABLE VOLTAGE AND CURRENT REGULATOR

High-Speed Inter Connect (HSIC) Solution

L6234. Three phase motor driver. Features. Description

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

MagIC Installation Manual. Point of Sales Terminals TD06014B

Applications SS 26 V- R

Agilent 8753ET/8753ES Network Analyzers

Ground Resistance Clamp On Tester

Release Notes: PowerChute plus for Windows 95 and Windows 98

CLASS-D VERTICAL DEFLECTION AMPLIFIER FOR TV AND MONITOR APPLICATION OUT CFLY + CFLY - BOOT VREG FEEDCAP FREQ. July /8

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Transcription:

Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance Measurements For precision bench-top applications, the 1-channel 4339B is the premier solution for accurate high resistance and low current tests. For high resistance testing in manufacturing environments, the 4349B offers simultaneous 4-channel high resistance measurements for increased test throughput. Satisfy Your Needs for... High quality results High confidence testing with contact check function Remove parasitics with error correction Consistent data with 0.6% basic accuracy Compensation for handler contact chattering with trigger delay Versatile measurements Select from four test parameters Use a variety of test fixtures and accessories Perform a charge-measuredischarge sequence with the test sequence program function Save and recall up to ten measurement setups High test throughput: 4349B 9.5 ms measurements 4-channels for multiple DUTs 4-channel simultaneous testing Fast contact checking: 2 ms/ measurement GPIB and handler interfaces Ideal for high volume capacitor testing

Display: LCD with back-light. Displays measurement values, instrument states, and comparator results. Test sequence program: Controls a series of resistance measurements. (Charge-measure-discharge) Open: Compensates leakage current and capacitance in test fixtures and cables. Measurement parameter: Selects the right parameter for the measurement. Comparator: Selects values for high, in, and low testing. Save/Recall: Stores and retrieves up to 10 measurement states. Contact check: Verifies reliability of capacitor test connections. Agilent 4349B 4-channel high resistance meter Key parameters and specifications Agilent 4339B Agilent 4349B Test channels 1 2ch, Option 4349B-001 4ch, Option 4349B-700 Test voltage(vdc) 0.1 to 1000 Requires external power source 1 Measurement parameters R, I, pv, ps R, I Measurement range (Ω) 10 3 to 1.6x10 16 10 3 to 10 15 Basic accuracy 0.6% 2% Display resolution 3 / 4 / 5 digits 3 / 4 / 5 digits Measurement time 10 ms/30 ms/390 ms 9.5 ms/28 ms/98 ms/397 ms 2 1. External power source required for resistance measurements. Recommendation for external power source for measurement for 1 GΩ sample at 100 Vdc with accuracy = ±10%: Ripple: 1 mvrms (50/60 Hz) Wideband noise: 5 µvrms/hz (50 Hz) Switching noise: 50 mvrms (100 khz)

High quality measurements with flexible hardware Resolve data to 5 digits (3, 4, or 5 digits selectable) Make precise measurements with 0.6% basic accuracy Verify DUT performance at the exact voltage rating Reliable and safety measurements with Agilent 16339A component test fixture 4339B solutions for high voltage material testing Resistivity mathematics built-in: surface and volume Agilent 16008B resistivity cell for solid samples Easy measurements with test sequence program function (controls charge-measuredischarge sequence) Customize your fixture cabling with the Agilent 16117C test leads System features you need to be successful Maximize accuracy with error correction Test capacitor contact failure with contact check function Automate testing with GPIB interface Reduce ground-loops with isolated handler interface Pass/Fail testing with comparator function (high/in/low) Capacitor evaluation with the 4349B Optimize capacitor Vdc rating tests Increase throughput four times with 4-channels Improve reliability with contact check Get low noise results with Agilent 16117E test lead 3

Resistance RM (Ω) Current IM (A) Resistance measurement Accuracy Current measurement Accuracy Test voltage setting Vs (V) V o = 0.1 V @ V s 200 V = 0.5 V @ V s > 200 Figure1. Conversion diagram Table 1. Agilent 4339B measurement accuracy (±% of reading) Specifications Measurement Accuracy Agilent 4339B test conditions*: 1. Warm up time: 30 minutes 2. Ambient temperature: 23 C ± 5 C 3. Test cable length: 1.5 meters 4. Open error correction performed 5. Long measurement time setting 6. Contact check: off Accuracy parameters: Rm: Measured resistance value in W Im: Measured current value in amperes Vs: Source voltage in volts Vo: 0.1 V@Vs 200 V, 0.5 V@Vs > 200 V Accuracy example: To determine the accuracy of a measurement use Figure 1, Conversion diagram. For example: determine the accuracy of a 5 MΩ (= 5 x 10 6 Ω) measurement at 50 Vdc. Rm = 5 x 10 6 Ω Vs = 50 V The intersection of Rm running parallel to the 10 6 Ω diagonal line intersects the vertical Vs line at the second row from the bottom of the diagram. Moving horizontally across to Table 1, the following equation is found: 100 Vo + (2.5 x 10-7 x Rm) 0.5 + Vs Entering the values for Rm, Vo, and Vs yields an accuracy of ±0.725%. 4

Resistance RM (Ω) Current IM (A) Resistance measurement accuracy Current measurement accuracy Test voltage setting Vs (V) Figure 2. Conversion diagram Table 2. Agilent 4349B measurement accuracy (±% of reading) Agilent 4349B test conditions 1 : 1. Warm up time: 30 minutes 2. Ambient temperature: 23 C ± 5 C 3. Test cable length: 1.5 meters 4. Open error correction performed 5. 30 ms measurement time setting Accuracy parameters: Rm: Measured resistance value in ohms Im: Measured current value in amperes External power supply parameters: Vs: Source voltage in volts Vo: Source offset voltage in Volts Av: Voltage accuracy 1. Other test condition data available in the operation manual. 5

Other Specifications Measurement parameters/ranges Parameter Agilent 4339B Range R (dc resistance) 10 3 Ω to 1.6 x 10 16 Ω I (dc current) 60 fa to 100 µa ps (surface Refer to operation resistivity) manual pv (volume Refer to operation resistivity) manual Agilent 4349B R (dc resistance) 10 3 Ω to 10 15 Ω I (dc current) 1 pa to 100 µa Measurement conditions and functions DC test voltage (4339B): 0 V to 1000 V, 0.1 V steps @ V 200V, 1.0 V steps @ V > 200 V DC test voltage (Agilent 4349B): None supplied, use external power supplies and voltage data entry for resistance measurements. Maximum of 5000 V input and 5 digit numerical entry. Max current (Agilent 4339B): 10 ma @ 100 V, 5 ma @ 250 V, 2 ma @ 500 V, 1 ma @ 1 kv Number of test channels: 4339B: 1 channel, 4349B: Option 4349B-700:4 ch Option 4349B-001:2 ch Ranging: Auto and hold Trigger: Internal, manual, and external Delay time (trigger): 0 ms to 9999 ms in 1 ms steps Test cable lengths: 2 meters maximum Measurement time (typical): 4339B: 10 ms / 30 ms / 390 ms 4349B: 9.5 ms / 28 ms / 98 ms / 397 ms Other instrument functions Error correction: Open (removes errors due to parasitics). Comparator: High, in, and low for each of the test parameters. Save/Recall: 10 instrument states from non-volatile memory. Contact check: Detects contact failure for capacitive devices (2 ms). GPIB: Agilent s implementation of IEEE 488 for control and data. Handler interface: Negative logic and isolated. Signals are high/in/low, no contact, EOM, index, alarm, keylock, ext. trigger. Physical characteristics Power: 90 132 Vac or 198 264 Vac. 47 Hz 66 Hz. 45 VA (typical) Operating temperature/humidity: 0 45 C/ 95% RH @ 40 C. Dimensions: 320(W) x 100(H) x 450(D) mm. Weight: 6.5 kg (typical). 6

Test Fixtures/Accessories Agilent 16339A component test fixture For manual high voltage testing of discrete components. For 4339B only. Option 16117B-003 Agilent 16117C low noise test leads Interlock, voltage source, and current sensing cables. Terminations are threaded triaxial, standard BNC, and bare interlock pair. Female BNC and triaxial connectors are included. For 4339B only. Agilent 16008B resistivity cell For resistivity measurements of dry sheet samples. Upper electrode is spring loaded to apply pressure. Surface and volume measurements. Installed with 50 mm diameter electrode. Option 16008B-001 adds 26 mm/76 mm diameter electrodes. Option 16008B-002 adds 26 mm diameter electrode. For 4339B only. Maximum applied voltage: 1000 Vdc. Sheet thickness range: 10 µm to 100 mm. Option 16117B-001 Option 16117B-002 Agilent 16117B low noise test leads Wide jaw clip leads for 4339B. 1 meter cable. Applicable measurement range: 1 x 10 11 Ω (typical). For 4339B only. Option 16117B-001 adds a pair of pin-type probes. Option 16117B-002 adds a pair of socket adapters for connecting to a custom made fixture. Option 16117B-003 adds a pair of alligator clips. Agilent 16118A tweezer test fixture Tweezer test fixture for easy testing for chip components. Maximum applied voltage: 100 Vdc. Applicable measurement range: 1 x 10 11 Ω (typical). For 4339B only. Agilent 16117E low noise test lead Male-triaxial to male-triaxial connectors. One meter cable. One femaletriaxial connector included. For 4349B only. 7

Ordering Information = Choose ONE and ONLY one q = Choose any combination Agilent 4339B High Resistance Meter 1 Furnished accessories: shunt connector Documentation options 2 q Option 4339B-ABA q Option 4339B-ABJ q Option 4339B-0BW Certification option q Option 4339B-1A7 Add specified quantities of English manual Add specified quantities of Japanese manual Add service documentation, assembly level ISO 17025 compliant calibration Agilent 4339B test fixtures and accessories Agilent 16008B Resistivity cell (50 mm diameter electrode) q Option 16008B-001 Add 26 mm and 76 mm diameter electrodes q Option 16008B-002 Add 26 mm diameter electrode Agilent 16117B Low noise test leads q Option 16117B-001 Add pin probes q Option 16117B-002 Add soldering sockets q Option 16117B-003 Add alligator clips 3 Agilent 16117C Agilent 16118A Agilent 16339A Low noise test leads Tweezer test fixture Component test fixture Agilent 4349B High Resistance Meter 4 Test channel options 5 Option 4349B-700 4-channels Option 4349B-001 2-channels Agilent 4349B high resistance meter 6 Documentation options q Option 4349B-ABA Add specified quantities of English manual q Option 4349B-ABJ Add specified quantities of Japanese manual q Option 4349B-0BW Add service documentation, assembly level Cabinet options 7 q Option 4349B-1CM Rack mount kit q Option 4349B-1CN Front handle kit Certification option q Option 4349B-1A7 ISO 17025 compliant calibration Agilent 4349B Test Fixtures and Accessories Agilent 16117E Low noise test lead Web Resource www.agilent.com/find/lcmeters Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.agilent.com For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894-4414 Latin America 305 269 7500 United States (800) 829-4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 0820 87 44 11 Belgium 32 (0)2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0)10 855 2100 France 0825 010 700* *0.125 /minute Germany 01805 24 6333** **0.14 /minute Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0)20 547 2111 Spain 34 (91)631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0)118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: March 27, 2008 Product specifications and descriptions in this document subject to change without notice. 1. Test fixture is not furnished with the 4339B. 2. Manual is not furnished with the 4339B. 3. The alligator clips are not furnished as standard. 4. External power source required for resistance measurements. 5. 2-channels to 4-channels upgrade not available. 6. Manual is not furnished as standard. 7. Rack flange and handle kit are not compatible. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Technologies, Inc. 1996, 2000, 2002, 2003, 2004, 2008 Printed in USA, April 15, 2008 5964-6182E