Nashville Electric Service



Similar documents
Kolorlux. GE Lighting DATA SHEET

Metal Halide Pulse Start vs. Probe Start. By Dick Erdmann GE Specification Engineer

SYLVANIA METALARC Pulse Start Metal Halide Lamps

St. Petersburg Retrofit Projects

DuroSite TM High Bay Lighting

Lumination LED Luminaires

Multi-Vapor Metal Halide Lamps

LED Tubular Lamp / Kit Guide

IPS HIGH-BAY / LOW-BAY LIGHTING

Session 15 Lighting Fundamentals

Rated Lumen [lm] Nominal. Volts [V] [lm]

Introduction GE LAMPS GE BALLAST ( ) Introduction/Overview to Lamps and Ballasts...A

induction lighting toll free: tel: fax:

Chris Kilpatrick Director of Rates

Petrol Station Canopies

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Applications. Architectural

Codes and Standards Enhancement (CASE) Initiative For PY2008: Title 20 Standards Development

Lumination LED Luminaires

GE Lighting. maximize. GE energy-efficient T5 linear fluorescent systems

LED Street Lighting Pilot Project Overview

`ÉàÉÜvçvÄxÅxàtÄAvÉÅ \ÇvA 5490 S.W. 42nd St. Davie, FL Toll free Local

Why Philips LEDtube? LED Lamps EMEA February February 2015_BG LS & E LEDlamps

LIGHTING and LIGHTING SYSTEMS

Special Specification 6111 LED Neighborhood Friendly High Mast (NFHM) Illumination Assemblies

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

Property Risk Management HIGH INTENSITY DISCHARGE ELECTRICAL LIGHTING

Frequently Asked Questions about Hazardous Waste Lamps (e.g., fluorescent or other lights containing mercury)

Downsize your downlighting costs with LED PLC. The first retrofit LED PLC lamp designed to increase efficiency and downsize your costs.

LicensedArchitect. $6.00 Volume 15, No. 3 Fall Association of Licensed Architects

Commercial LED Lighting Equipment

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

Solid State Lighting Definitions for Functional and Decorative Applications

Prescriptive Program Rebate Application

Invitation to Bid SCHOOL SIGN - MCE

Small Business Lighting

The Latest in LED Lighting Test Methods and Standards. Jianzhong Jiao, Ph.D. OSRAM Opto Semiconductors Inc.

High Pressure Mercury

Nightline A/B Wall and ceiling mount luminaires for discharge lamps

PPL Electric Utilities Energy Efficiency and Conservation Program

12 Volt Lighting Products

Lighting New Construction Incentive Application for Business Customers

In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).

Innovative. Lum. Flux** [lm]

ECOPTIMO T8. Version IRIS 2002,S.A. C/San Agustin, Madrid SPAIN T F

(Refer Slide Time: 00:01:43 min)

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Commercial Energy Savings Guide.

LED High Bay Light 100W

T5 LongLast. GE Lighting DATA SHEET

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

Product Safety Notice Evolution Floodlight

Recessed. EvoKit LED Retrofit Kits Gen 3

Electric Sign Energy Certification Service To California Energy Commission Title 24 Technical Requirements and Audit Instructions (ENVS) Header Title

High Bay Occupancy Sensor Selection Guide

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires

Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting

SECTION F HALOGEN LAMPHOLDERS HALOGEN LAMPHOLDERS Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: Fax:

Retrofit HID High Bay Fixtures to Long Life High Efficiency LED

Intelligent Light. Everywhere.

SECTION COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY

Business lighting guide

Introduction. Terms. LED Application Series: Outdoor Area Lighting

American National Standard for Electric Lamps Specifications for Performance of Self-ballasted Compact Fluorescent Lamps

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

V anguard. applications 5.1. vanguard vanguard. Assembly lines. Production areas. Gymnasia. Swimming pools. Clean areas. Food processing areas

Halogen Lamps. Lamp Construction

ENERGY EFFICIENT LIGHTING

Answers. T8 Fluorescent Lamps. ... Volume 1 Number 1 April Background. What does T8 mean?

ConstantColor CMH MR16

LED RETROFIT OPTIONS FOR LINEAR FLUORESCENT LUMINAIRES

Voltage 12050HZ 23050HZ 1

Technical Information. Lamp Data - Light tubes

Lighting Retrofit Incentive Application for Business Customers

Lumination LED Luminaires

LIGHT SOURCES JAN2016

Nightscape High performance floodlights and spotlights for discharge lamps

Dialight LED Lighting Fixture Catalog. for Industrial and Hazardous Locations

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

commercial HID lighting table of contents LIGHTING

GE ConstantColor CMH Precise MR16 20 & 35W

Why Philips LEDtube? Leander Bloot Product marketing LEDtubes LED Lamps EMEA January January 2014_BG LS & E LEDlamps

Leaders In Industrial LED Lighting Solutions. CleanLED Highbay/Lowbay. Energy Efficient LED Lighting Solutions For Industry

A-SERIES Small Aperture LED, Halogen and Metal Halide Recessed Luminaires

LED Life for General Lighting: Definition of Life

Transcription:

Nashville Electric Service Specification ESL-601-1 Description: High Intensity Discharge Lamps 1.0 Scope... 2 2.0 General Requirements... 2 3.0 Information to be Returned... 4 4.0 NES Policy... 4 5.0 Revision History... 5 6.0 Approval Signatures... 5 The Electric Power Board of the Metropolitan Government of Nashville and Davidson County

1.0 SCOPE 1.1 The purpose of this specification is to insure the furnishing of a high intensity discharge lamp of high quality, manufactured in accordance with current applicable Electrical Industry Codes, American National Standards Institute and Underwriters Laboratory requirements. 1.2 It is intended that this specification shall serve as a guide to the supplier to prepare a quote. This specification is not intended to be a detailed a specification. The supplier will furnish complete descriptive information including the specifications for the lamp being quoted. 2.0 GENERAL REQUIREMENTS 2.1 The lamp shall be designed and constructed to the most current recommended practices of the IES, ANSI, and NEMA. The lamp operating voltage and ANSI ballast codes shall be as follows: Lamp Watts/Approx. Init. Lumens Lamp Type 100/9,500 Metal Halide (MH)/Pulse Start- ED 17/Med 175/13,500 MH-ED 28/Mogul 175/16,000 MH-Pulse Start-ED28/Mogul 250/20,500 250/20,000 MH-ED 28/Mogul MH-Pulse Start-ED28/Mogul 320/30,000 MH-Pulse Start-ED 28/Mogul 400/36,000 MH-ED 37/Mogul 400/42,600 MH-Pulse Start-BT-28/Mogul Approx. Initial Lamp Rated Voltage ANSI Ballast Code 100 M90 132 132 133 133 M57 M152 M58 M153 132 M132 135 135 M59 M155 1000/110,000 MH-BT 56/Mogul 263 M47 70/6,500 High Pressure Sodium (HPS)- ED 17/Med 52 S62 100/9,400 HPS-ED 23.5/Mogul 55 S54 150/15,800 HPS-ED 23.5/Mogul 55 S55 250/27,000 HPS-ED 18/Mogul 100 S50 400/50,000 HPS-ED 18/Mogul 100 S51 1000/140,000 HPS-ED 25/Mogul 250 S52 2.2 The lamp shall be of the high intensity discharge type, universal operating position, clear, mogul base ANSI type E39 (or medium base, ANSI type E26, where required by request for quotation) and specifications as otherwise described in the request for quotation. 2

2.3 The screw shell base of the lamp shall be constructed of brass or nickelplated brass. 2.4 The lamp shall include a date code etched into the base of the lamp to indicate manufacturing date of the lamp. The base shall also include a code for the installer to indicate the installation date of the lamp. 2.5 The lamp shall be constructed of hard glass which shall be designed for an operating temperature up to 400 C. or as otherwise required by ANSI standards for the lamp being furnished. 2.6 The lamp base shall be designed for an operating temperature up to 210 C. or as otherwise required by ANSI standards for the lamp being furnished. 2.7 Lamps meeting current US Environmental Protection Agency s guidelines of Toxicity Characteristic Leaching Procedure (TCLP) for non-hazardous waste (or State of Tennessee requirements of the same guidelines, if more stringent) will be acceptable but are not required. 2.8 The lamp warranty shall be based on 12 hours per start per day operating cycle. 2.9 The high pressure sodium lamp shall be consist of a single arc tube unless specified otherwise in the request for proposal. 2.10 The high pressure sodium lamps shall have arc tube manufactured of PCA (polycrystalline alumina) tubing. 2.11 The color rendering index of high pressure sodium lamps shall be a minimum of 21 unless otherwise required by the request for proposal. 2.12 High color rendering index high pressure sodium lamps shall have a minimum CRI of 65. 2.13 Dual arc tube high pressure sodium lamps shall be of the same size and operate on the same ballast with the same lumen output as the single arc tube lamp. The dual arc lamp shall have instant re-strike capabilities for the first 24,000 hours of average life. The lamp shall be of the monolithic arc tube design. The two monolithic arc tube shall be mounted in parallel and provide 40,000 average hours of life. Dual arc tube lamps of other designs may be acceptable if the bid contains endorsements by other electric utilities and pre-qualification requirements have been met. 2.14 The metal halide lamp shall be of the universal burning position. 2.15 The color rendering index of metal halide lamps shall be a minimum of 65. 2.16 The metal halide lamp shall be designed to operate in an enclosed type luminaire. However, lamps designed to operate in an open type fixture will be acceptable. 2.17 Lamps which convert high pressure sodium to metal halide shall operate on existing high pressure sodium systems with an external ignitor requiring no modifications to the luminaire. The CRI shall be a minimum of 65. 3

3.0 INFORMATION TO BE RETURNED 3.1 The supplier s quotation shall include the information listed below. 3.2 Shipping date from the supplier s facility. 3.3 List exceptions to this specification (or notations on drawings or catalog cuts of exceptions to this specification). 3.4 At a minimum, the manufacturer s warranty shall provide for proportionately credited lamps which fail to operate according to the following interval based on the manufacturer s date code on the base of the lamp: Operating Intervals Upon receipt First Year Second Year Third Year Credit d on 4500 Hours/Year Operation Fully Credited Two (2) lamps for every failure One (1) lamp for every failure One (1) lamp for every two (2) failures 3.5 To pre-qualify for a NES request for quotation, the manufacturer must present technical information indicating that the lamp meets the requirements specified here-in, three lamp samples, and recommendations from three utilities purchasing the lamps, on more than one occasion. The utility recommendations must include the name and phone numbers of the utility representatives. 4.0 NES POLICY 4.1 NES reserves the right to reject any or all quotations. 4