EXPERTS IN WATER COOLING SINCE 2001. aquastream ULTIMATE SUPER SILENT PUMP TECHNOLOGY. The ultimate pump system. www.aqua-computer.



Similar documents
User and installation manual

Series 6000 Torque measured metal bellow coupling

User Guide Reflow Toaster Oven Controller

SYSTEM 45. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design

FTDI VCP DRIVER (free) (WIN/MAC/LINUX)

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

UIM2901-5A MACH3 breakout board

RPLIDAR. Low Cost 360 degree 2D Laser Scanner (LIDAR) System Development Kit User Manual Rev.1

Series 7500 Torque Sensor

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

HXi High Performance Power Supply Series Corsair HX750i Power Supply

Fingerprint Based Biometric Attendance System

Combi B Alarm box. Mounting instructions

ENAiKOON ultrasonic fuel-level sensor

Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications

DCP Fan Controller. Version 01/2009. The engineer s choice

LIFT CONTROL SYSTEMS CATALOGUE 2007

Rapid Audio Prototyping

Lab Experiment 1: The LPC 2148 Education Board

How To Control Gimbal

Installation and instruction manual for Laing DDC pumps

EVAL-UFDC-1/UFDC-1M-16

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

EFC Frequency converters

AN2680 Application note

SPEED CONTROL SYSTEM

LIFT CONTROL SYSTEMS CATALOGUE 2007

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Design of an Insulin Pump. Purpose of an Insulin Pump:

Phase-Control Alternatives for Single-Phase AC Motors Offer Smart, Low-Cost, Solutions Abstract INTRODUCTION

MODEL 2202IQ (1991-MSRP $549.00)

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Bluetooth UART/RS232 Module

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Physical Specifications (Custom design available.)

Dyeing Programmer DP - 01

TMS TANK MANAGEMENT SYSTEM

Designed for multi-injector endurance testing, the

USER MANUAL V5.0 ST100

KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger

DRM compatible RF Tuner Unit DRT1

How to design an insulin pump

I STAR COMPUTER CO., LTD

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

SystemGuard. Brief Description. Benefits. SystemGuard Main Window

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Conductive Level Switch FK 2 Technical Data:

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Frequency Converter Fv

SMART SENSOR COLLECTION

If you are uncertain whether or not your ENERMAX NOISETAKER II PSU is defective, please contact your dealer/reseller for support!

Transmitter Interface Program

Technologies for Data Centres

Electric Coolant Pumps. Always at the Correct Temperature

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Nardalert S3 Non-Ionizing Radiation Monitor

... Electronic Softstarter...

400w/450w/550w/650w/750w

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

MAC-8. Technical Documentation AC Voltage Input Submodule. Please keep for further use!

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Design of Strong-motion Monitoring System for Dam-reservoir D s e i s gn of Stro r ng-mo m tion Monito t ri r ng Syst s em

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

MATRIX borehole logging system

API Marine. BMS Presentation. Ballast Measurement Systems

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA info@anaheimautomation.

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

The Heartbeat behind Portable Medical Devices: Ultra-Low-Power Mixed-Signal Microcontrollers

RET control-visc. The Magnetic Stirrer for Scientists. designed. Phil S. Baran Ph.D. Baran uses IKA equipment. to work perfectly

STERILIZERS, LABORATORY DRYING OVENS

Global Motion Technology Inc Web THCSA200. Capacitive sensor plasma & Oxy-fuel Torch Height Control

RAINCONTROL LCD Special

If you are uncertain whether or not your ENERMAX PSU is defective, please contact your dealer/reseller for support!

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

Current Monitoring Kit QUICK START GUIDE

DRV8312-C2-KIT How to Run Guide

NEW. EVEN MORE data acquisition and test stand automation

LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators

Energy Saving ECM Motors and Fans Ventilation Catalogue

Solar Cybertech: A Competition of Digitally Controlled Vehicles Poweredby Solar Panels

Series AMLDL-Z Up to 1000mA LED Driver

Current Monitoring Kit

DS1104 R&D Controller Board

LMS Test.Xpress Powering personal productivity

Vibration analysis and monitoring Compact. Powerful. Modern technology.

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS

Application/Connection Examples

Product Information Sheet UH36 Hi Pot Tester

The Universal DAQ Device. Connect and measure immediately!

BIG SAVINGS FOR A LOT MORE APPLICATIONS

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

PowerGem Pro Uninterruptible Power Supply

Electronic Pressure Switch EDS 300

AN588 ENERGY HARVESTING REFERENCE DESIGN USER S GUIDE. 1. Kit Contents. 2. Introduction. Figure 1. Energy Harvesting Sensor Node

How To Use The Dc350 Document Camera

Sense it! Connect it! Bus it! Solve it! EncoderS

Transcription:

The ultimate pump system www.aqua-computer.de

AQUASTREAM Since its market introduction in 2003, the name stands for reliable and durable water cooling pump technology - made in Germany. We have bundled all our experience and in addition we have added many wishes of our customers to form a masterpiece of german engineering. Our focus during development of this new pump was to achieve maximum quality. Driven by this desire, nearly every part of this pump is produced in Germany and has been precisely selected for maximum durability. With the introduction of the new, we have raised the technological level in the water cooling pump market to a new level. There is no other pump in this market like the. For the next years, we will still keep on developing the software to make it even better. PUMP DRIVE The pump is the heart of any water cooling system. If the pump fails, the complete system fails. For the we are using a bearing system made from highest quality ceramics with an life expectancy of more than 10 years of permanent use. To reduce vibrations, the bearing system is decoupled in rubber bearings. The ample length of the bearing system results in smooth operation of the pump drive. Every material that is used has been selected for high strength and lifetime. The motor parameters are monitored 20,000 times a second. Based on this data, the motor control of the pump is optimized to reduce vibrations and to achieve a nearly noiseless operation. Our new digital motor control system provides some great functions. For example, the motor controller can now find the maximum motor speed in real time without pump restarts. ELECTRONICS The control system of the is based on a 32-bit microcontroller with integrated DSP that provides an even higher performance than the aquaero 6 MCU! A multi-layer PCB with very small structures enables us to integrate all components in the small pump housing. A native USB 2.0 interface connects the to your PC. With our aquasuite software all functions of the pump can be controlled and monitored. In addition, software updates can be performed using the aquasuite software. Nearly every function of the pump can also be controlled directly at the unit by using the well structured menu on the 128x64 pixels OLED display. The menu is very smart and shows you a preview of the selected value at the bottom line in many cases. The aquabus interface connects the pump to the powerful aquaero control system (aquaero 5 and higher). An integrated buzzer can be enabled for customized alarm levels (water temperature etc.). Gelliehäuser Str. 1-37130 Benniehausen

SENSORS The features an integrated water temperature sensor. In addition, an external temperature sensor can be connected to the pump. If an Aqua Computer flow sensor is connected to the unit, it is possible to monitor the flow rate of the system. An extended alarm management with acoustic and optical alarms is integrated in the. It also provides two options to shut down a PC in case of an emergency: The first is the generation of a virtual fan tacho signal. The signal can be disabled in case of an alarm and the connected mother board can shut down the PC. The second solution is to connect the to your power switch with an optional cable. In this case, the power switch can be controlled by the pump. But there are many more sensors in the : The current load and voltage of the pump motor is measured and the power consumption is calculated. The same is applicable for connected fans. The torque of the fan is calculated as well. CONTROLLER Providing more features than any other pump in the market, the can additionally control a group of fans with a total current load of max. 1 A (a peak current of up to 1.5 A at start-up is allowed). The device is able to control PWM (4-pin) and voltage controlled (3-pin) fans. The fan amplifier circuit is an advancement of the aquaero 6 amplifier design and provides an even higher efficiency. We have added many functions to improve the reliability of the fan controller: It provides short circuit, over current, over temperature and over voltage protection. In interaction with the integrated water temperature sensor, the fan controller is able to adjust the fans without any additional components. After setting a target value for the water temperature, the will do everything that is necessary to maintain this value. The RPM signal of the fans can be monitored by the. THE ENSEMBLE In the end the ensemble counts: The combines a pump, advanced sensor technology and a great controller to a wonderful product. If you use this product, you will notice how seamlessly all functions will interact with each other. After adding an aquainlet reservoir, you will only need to buy a radiator and water blocks to complete your system. As if by magic, the pump motor and the fans will be controlled by the current load of your system. Flow, temperatures, fan rpm - everything can be monitored and can raise optical or acoustic alarms. Your PC is protected against damages and in an ermergency, the can shut down your PC for protection. Just enjoy this ultimate solution! Gelliehäuser Str. 1-37130 Benniehausen

OPTIONEN VIRTUAL FLOW During the development of the, we put a lot of effort in a wonderful new function: The virtual flow sensor. We provide this function as a software extension that can bought separately. After purchase of this option, the is able to calculate the flow rate from complex calculations based on the real-time monitoring of pump parameters. The virtual flow sensor can be used to ensure that a sufficient flow rate is maintained in the water cooling system. In case of a failure, an alarm can be triggered. Limitations of the virtual flow sensor: The accuracy of this function is not equivalent to a real flow sensor and it can only be used if the is the only pump in the circuit. If more than one pump is installed, a real flow sensor has to be used. CONTROLLERS Another great upgrade we can offer is the advanced controller package. If you purchase this option, additional controllers will be unlocked. In addition to the target value controller, the fans can be controlled by a curve controller or a two-point controller. The curve controller allows the user to set up a relation between temperature value and target fan power in a simple graphical curve. The two-point controller allows to switch the fan output at user definable temperature values. Another controller included in this package enables the to control the pump speed in relation to a temperature value. It enables the pump to automatically speed up the pump motor at rising water temperature and thereby increasing the flow in the system. The last component of the package is an option to directly control the flow of your system. Simply set a target value for the flow and the will control the pump speed to match the value. This function can also be used with the virtual flow sensor option! UPGRADE Longevity and reliability - that is our goal. In times of many environmental problems, we would like to go ahead with good practice. This is why our very first CPU water block cuplex (released in 2001) can still be converted to the latest CPU sockets and we are providing all necessary spare parts to do it: A long-lasting product is the best way to protect the environment. In order to do so, we remain true to this idea: Any pump shipped since 2003 can easily be upgraded. In case of the XT series, only the controller of the XT has to be exchanged with the controller to perform this upgrade. We have added userfriendly clamp contacts to the new controller, so the exchange can be performed without soldering and is generally done in less than 2 minutes. In many cases the upgrade can be performed without draining the cooling loop. Gelliehäuser Str. 1-37130 Benniehausen

COMPARISON CHART Feature Manual pump speed control Automatic pump speed adjustment USB and aquabus interface Deaeration mode Rotation detection Configurable speed signal output Adjustable fan output Internal water temperature sensor External temperature sensor connector Temperature controlled fan output Connector for optional flow sensor Real-time pump speed adaption Graphic OLED display, 128x64 pixels User Interface with smart menu High power, high efficiency 1 A fan output Automatic power consumption reduction Standard Advanced Ultra Gelliehäuser Str. 1-37130 Benniehausen

DIMENSIONS Dimensions are given in mm. TECHNICAL DATA SUPPLY VOLTAGE 12 V DC FLUID recommended: DP Ultra water, max. 30 % glycol POWER CONSUMPTION 3-25 W FAN OUTPUT CURRENT max. 1 A MAXIMUM PRESSURE WATER TEMPERATURE 445 mbar 0-50 C DISPLAY white OLED display 128x64 pixels Gelliehäuser Str. 1-37130 Benniehausen