Field Test to Demonstrate Real-Time In-Situ Detection of Volatile Organic Compounds Hazmat Spill Center, Nevada Test Site September 19-25, 2001



Similar documents
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Remediation of VOC Contaminated Groundwater

April 30, 2013 E M. Environmental Management. safety performance cleanup closure

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

1. PUBLIC HEALTH STATEMENT

Inventory of Performance Monitoring Tools for Subsurface Monitoring of Radionuclide Contamination

CHAPTER 13 LAND DISPOSAL

Utilizing an Innovative, Effective Site Assessment and Monitoring Tool

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Frequently Asked Questions FAQ (click to follow link) How Does The Thermal Well System Work? How Much Does It Cost?

DRY CLEANING PLANTS REQUIREMENTS FOR INSTALLATION AND OPERATION

6 H2O + 6 CO 2 (g) + energy

How To Use A Water Source Heat Pump

Presented by: Craig Puerta, PE, MBA December 12, 2012

PREVENTING GROUNDWATER POLLUTION: SECONDARY CONTAINMENT

A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas

CHEMICAL CLEANING UNIT Product number:

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Anode Rods, Cathodic Protection and the Porcelain (glass) Lining

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

ORGANIC SAMPLE PREPARATION

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Outages Happen 24/7 So Should Monitoring / SAFEGUARD YOUR HIGH VOLTAGE ASSETS WITH VAISALA ONLINE MONITORING

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

Fundamentals of Mass Flow Control

Morrison Bros. Co. General Product Specifications

High Performance PSA in Sheet Membrane in Water Protection

Ultrasonic support removal tank

Ultra HardTop P2. Ultra HardTop P4. Outdoor Secondary Containment Storage Systems Keep The Elements Out While Providing Convenient Access To Drums

STANDARD OPERATING PROCEDURE

TCE. The Use & Remediation of TCE at NASA. Keep reading. is developing innovative. NASA s pollution prevention efforts significantly reduced TCE use

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

Extraction Oil and Gas, LLC. Diamond Valley Central Oil Terminal Waste Management Plan

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

DISSOLVED OXYGEN PROBE

Trace Gas Exchange Measurements with Standard Infrared Analyzers

Reaction Engineering of Polymer Electrolyte Membrane Fuel Cells

Fire Event Electronic and Mechanical System Damage Mechanisms Is Acid Gas for Real?

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

SOLAR WATER PURIFICATION WITH THE HELP OF CSP TECHNOLOGY

Determination of the enthalpy of combustion using a bomb calorimeter TEC. Safety precautions

U. S. Army Corps of Engineers Ground Water Extraction System Subsurface Performance Checklist

The photoionization detector (PID) utilizes ultraviolet

Waste and Cost Reduction Techniques for Small Parts Cleaners

CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER

How To Use A Ds340 (Dsp)

HYDROCARBON SPILLS PROCEDURE SIG-ENV-PR003

Heating Cable. Construction

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Basics of Kraft Pulping & Recovery Process. Art J. Ragauskas Institute of Paper Science and Technology Georgia Institute of Technology

Soil Suction. Total Suction

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

Regulated Waste Storage

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

In-situ Bioremediation of oily sediments and soil

Fuel Oils. Public Health Statement for. June 1995

To measure the solubility of a salt in water over a range of temperatures and to construct a graph representing the salt solubility.

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

Container Management for Hazardous Waste Generators Technical Guidance Document HW-2005-G1

Moisture Management of Below-Grade Construction Basements

ETV JOINT VERIFICATION STATEMENT

How To Safely Handle A Spill

SenTix 950 SenTix 980

1.34 WASTE CONTAINMENT AND SITE REMEDIATION TECHNOLOGY TAKE-HOME FINAL EXAM DUE FRIDAY MAY 7, 2004 AT 9:30 AM

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

BLACK JACK ALL WEATHER ROOF COATING

Steel Spill Containment Pallets

7. Chemical Waste Disposal Procedures

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

COMBIMASS. Technical Data COMBIMASS eco-bio +

Activity: Clouds, Air Pressure and Temperature

BP WIND ENERGY POLICIES AND PROCEDURES

Leak detection technologies for the oil and gas industry. Chris Neidre Alex Robertson July 17, 2015

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Spill Prevention, Control and Countermeasure (SPCC) Rule

Subject: Technical Letter 22 April 1977 Removal of Water Supply Contaminants -- Copper and Zinc

Gas Chromatography Liner Selection Guide

Long-Term Hygrothermal Performance of Green Roofs

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

Method 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein

Typical commercial laboratory turn around - two days to two weeks In-house hexane/gravimetric several hours Results in the discharge of effluent

DOWEX Resins as Organic Solvent Desiccants

Electric Heat Tracing INSTALLATION PROCEDURES

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Heat Pipe Cooling of Concentrating Photovoltaic (CPV) Systems

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

A New Membrane System for Efficient Removal of Water from Gear Oil Road to Commercialization

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

Hazardous Materials & Spill Response

Mitos P-Pump. product datasheet

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

Onset Computer Corporation Inside this package: HOBO U20 Water Level Logger Calibration Certificate

Soil remediation you can trust In Situ Thermal Desorption. The real ISTD TERRATHERM R TECHNOLOGY. Technology

Best Practice in Boiler Water Treatment

Chapter 5: Spills Response

Transcription:

Field Test to Demonstrate Real-Time In-Situ Detection of Volatile Organic Compounds Hazmat Spill Center, Nevada Test Site September 19-2, 21 Clifford K. Ho Sandia National Laboratories Albuquerque, NM 8718 () 844-2384 ckho@sandia.gov Charles F. Lohrstorfer Bechtel Nevada Corporation Las Vegas, NV 89193 (72) 29-681 LohrstCF@nv.doe.gov Abstract Traditional methods for monitoring soils and groundwater that may be contaminated with toxic chemicals can be expensive, time consuming, and misrepresentative of in-situ conditions. This report presents a demonstration of a real-time in-situ monitoring system that can be used to detect volatile organic contaminants in soils and groundwater. A microchemical sensor that is packaged in a waterproof housing is used to detect trichloroethylene (TCE) in a sand-filled - gallon drum at the Hazmat Spill Center at the Nevada Test Site. Background and Objectives Tens of thousands of sites containing toxic chemical spills, leaking underground storage tanks, and chemical waste dumps require characterization and long-term monitoring to reduce health and environmental risks. Current methods are costly and time-intensive, and limitations in sampling and analytical techniques exist. For example, the Department of Energy (DOE) Savannah River Site requires manual collection of nearly 4, groundwater samples per year, which can cost between $1 to $1, per sample for off-site analysis. The integrity of off-site analyses can also be compromised during sample collection, transport, and storage. In addition, newly emerging threats of chemical contamination of our water supplies also requires more frequent (nearly continuous) monitoring that cannot be met by traditional methods. New technologies that provide real-time in-situ monitoring and characterization of volatile organic compounds (VOCs) that alleviate the need for manual sampling and off-site analysis may provide cheaper and more reliable information. One such technology is a chemical microsensor (chemiresistor) and monitoring package developed at Sandia National Laboratories that can provide real-time in-situ detection of volatile organic compounds. A demonstration was performed at the Hazmat Spill Center at the Nevada Test Site to test this sensor in a sand-filled -gallon drum containing trichloroethylene (TCE). Results are reported regarding the response of the sensor during the contaminant emplacement and remediation (air venting) of the sand. Microchemical Sensor and Packaging The microchemical sensor, or chemiresistor, used in the test consists of a chemically sensitive absorbent mixed with conductive particles that is deposited onto chip with wire-like electrodes. When chemical vapors come into contact with the absorbent, the chemicals absorb into the polymers, causing them to swell. The swelling changes the resistance of the electrode, which can be measured and recorded. The amount of swelling corresponds to the concentration of the 1

chemical vapor in contact with the absorbent, and the process is reversible. Two unique features exist regarding the chemiresistors being developed. First, the chips developed at Sandia can house an array of chemiresistors, a temperature sensor, and heater (Figure 1). The array of differing sensors can be used to identify different VOCs by comparing the resulting chemical signatures with calibration (or training) sets. The chemiresistor array has been shown to detect a variety of VOCs including aromatic hydrocarbons (e.g., benzene), chlorinated solvents (e.g., TCE), and aliphatic hydrocarbons (e.g., iso-octane). The temperature sensor and heater can be used to provide temperature control (although this feature was not used in the test). A second unique feature is that a rugged package has been designed and fabricated to house the chemiresistor array (Figure 2). This package is small (< 3 cm diameter) and is constructed of stainless steel. The package is waterproof, but allows vapors to diffuse through a GORE-TEX membrane. Therefore, if chemicals are dissolved in water, the aqueous-phase contaminants can partition across the membrane and into the gas phase where they can be detected by the chemiresistors. The chemiresistors are situated on a 16-pin dual in-line package that is connected to a weatherproof cable, which can be connected to any data logger. Experimental Setup ~ 2 mm Figure 1. Chemiresistor array developed at Sandia National Laboratories with four different conductive polymer films deposited on different electrodes. A platinum temperature sensor is located in the middle. Figure 2. Weatherproof chemiresistor package that can be emplaced in a monitoring well or cone penetrometer. The experiment consisted of a -gallon drum that was filled with sand. 1 A slotted PVC tube was placed vertically in the center of the drum to act as a contaminant reservoir. A slotted and screened 3-inch-diameter steel tube was placed 2 cm away from the reservoir to simulate a well (see Figure 3). The sensor package was suspended midway down the steel tube (~36 cm), and the cable was threaded through a port in the drum to an Agilent 3497A data-acquisition unit in a nearby trailer. The data-acquisition unit was connected to a laptop that used the Agilent Benchlink Data Logger software (v. 1.4). Figure 3. Top view of -gallon drum filled with sand. The contaminant reservoir is in the middle of the drum, and the sensor well is towards the outside. 1 Measured sand properties: grain density=2.3 g/ml; porosity=.39; saturation=.18; variable grain size 2

The experiment consisted of three phases: (1) a period of ambient background data logging for nearly four days to observe the impacts of diurnal temperature variations on the system; (2) emplacement of TCE into the contaminant reservoir; and (3) remediation using compressed air to vent the sand for a brief period. During the ambient logging, the drum was completely sealed (Figure 4). Then, the lid was removed and approximately 6 ml of TCE was emplaced in the contaminant reservoir. Approximately 3 ml was absorbed onto a wick that was placed in the reservoir, and 2 ml was poured into and around the reservoir (see Figure ). During the simulated remediation process, a compressed air tank was used to blow air (~1 ml/min) through four equally spaced ports around the bottom perimeter of the drum (see Figure 6). The air flowed through the contaminated sand and through the open top of the drum. During all phases, a tarp was draped around the drum to shade the drum from direct sunlight. Figure 4. View of the sealed -gallon drum. Results and Discussion Figure 7 shows the logged data from the sensor during the ambient data-logging period. Only the temperatures from the temperature sensor and the resistances from chemiresistor 3 are shown in Figure 7 (the response of the other three chemiresistors on the chip were similar to chemiresistor 3, so they were not reported to keep the plots clear). Figure. Emplacement of a TCE-soaked wick into the reservoir. The temperature sensor on the chip indicated that the temperatures oscillated between approximately 2 o C to 3 o C because of the diurnal heating and cooling. The chemiresistor also showed a response that closely resembled the temperature variations. As the temperature increased, the polymers swelled due to thermal expansion, which increased the measured resistance by breaking some of the conductive carbon-particle pathways in the polymer matrix. As the system cooled overnight, the polymers shrunk, and the measured resistances of the chemiresistors decreased as the carbon particles that were separated were brought into contact again. These temperature variations and its affect on the baseline chemiresistor resistance pose an issue for calibrations at low chemical concentrations, but at higher concentrations, the magnitude of the increased resistance overwhelms Figure 6. Air-ventilation system connected to the drum. the variations caused by temperature. 3

1 4 9 8 7 6 4 3 2 1 9/2/21 : 9/2/21 12: 9/21/21 : 9/21/21 12: 9/22/21 : 9/22/21 12: 9/23/21 : 9/23/21 12: 9/24/21 : Resistance (ohms) Sensor 3 Temperature 3 3 2 2 1 1 Temperature (C) Figure 7. Plot of chemiresistor temperature and resistance during the ambient data-logging period. Another interesting observation during the ambient period was that significant amounts of water condensed in the drum as the system cooled overnight. The liquid water was observed in large amounts on the lid, along the walls of the steel well (which showed evidence of rusting), and on the sensor package and cable. However, after unscrewing the sensor package, we observed that the chip and chemiresistors inside were dry and did not appear to show any signs of corrosion or mineral precipitation. Figure 8 shows a plot of the logged data during the TCE emplacement and venting periods. The chemiresistor shows a drastic increase in resistance only a few minutes after the TCE was emplaced. The resistances increased to greater than 1 MΩ, which was the maximum limit on the data acquisition unit. We expected that the response would take longer because the sensor was placed 2 cm away from the contaminant reservoir, and TCE vapors would have to diffuse through the sand. The sooner-than-expected response time may be due to the open headspace between the lid and the top of the sand. TCE could short-circuit the sand by diffusing through the open air in the headspace above the reservoir and then down the well to the sensor. After about four hours, the lid was removed and air was vented through the sand for about 4 minutes. Figure 8 shows that the resistances dropped significantly because of the purging of clean air through the system. After closing the lid and stopping the venting, the resistances began to increase again due to exposure to TCE vapors. It should be noted that the format of the raw data reported (resistances) can be converted to TCE concentrations using calibration curves, but because temperature variations also caused changes to the chemiresistor resistances, we decided to keep the data in its original form. 4

1.E+8 4 3 Temperature 3 1.E+7 1.E+6 1.E+ 9/23/21 : 9/23/21 4:48 9/23/21 9:36 9/23/21 14:24 9/23/21 19:12 9/24/21 : 9/24/21 4:48 9/24/21 9:36 9/24/21 14:24 9/24/21 19:12 9/2/21 : Resistance (ohms) Sensor 3 Venting 2 2 1 1 Temperature (C) Added TCE Figure 8. Plot of chemiresistor temperature and resistance during TCE emplacement and venting periods. Conclusions The -gallon-drum test conducted at the Hazmat Spill Center at the Nevada Test Site provided an opportunity to test the in-situ chemiresistor sensor package in harsh environments that included large temperature variations, significant moisture, and large TCE concentrations. The sensor was shown to provide a real-time, continuous response when exposed to TCE emplaced in the sand, and it also recorded a decrease in the TCE vapor concentration as clean air was vented through the system. In addition, the rugged sensor package was shown to prevent condensed liquid water from entering the package. Temperature variations were shown to impact the baseline chemiresistor resistances, but at high TCE concentrations, the temperature-induced resistance variations were overwhelmed by the increase in resistance due to TCE exposure. Future studies using this apparatus and other in-situ configurations are recommended to be performed to test the chemiresistor sensor package and other sensors for use in long-term monitoring applications. Objectives for future tests include maintaining a constant elevated temperature of the chemiresistors via the heater and temperature sensor on the chip. This will aid in providing more accurate calculations of concentration from calibrations, and it will prevent condensation of liquid on the chip. In addition, the integration of the real-time in-situ sensor with an air-venting remediation system can be tested. Finally, remote telemetry-based data transmission methods can be added to the existing in-situ monitoring system.