SAFETY MANUAL SIL Switch Amplifier



Similar documents
SAFETY MANUAL SIL SWITCH AMPLIFIER

SAFETY MANUAL SIL RELAY MODULE

SAFETY MANUAL SIL SMART Transmitter Power Supply

Failure Modes, Effects and Diagnostic Analysis

FMEDA and Proven-in-use Assessment. Pepperl+Fuchs GmbH Mannheim Germany

SYSTEM DESCRIPTION Termination Boards

Hardware safety integrity Guideline

Safety Manual BT50(T) Safety relay / Expansion relay

Selecting Sensors for Safety Instrumented Systems per IEC (ISA )

SIL manual. Structure. Structure

Version: 1.0 Latest Edition: Guideline

PROCESS AUTOMATION MANUAL OVERSPEED/UNDERSPEED MONITOR KF**-DWB-(EX)1.D ISO9001

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Inductive sensor NI10-M18-Y1X-H1141

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Value Paper Author: Edgar C. Ramirez. Diverse redundancy used in SIS technology to achieve higher safety integrity

,g) rrrs {fd fi. f il'ltdä. Failure Modes, Effects and Diagnostic Analysis. ABB Automation Products GmbH Alzenau Germany

Effective Compliance. Selecting Solenoid Valves for Safety Systems. A White Paper From ASCO Valve, Inc. by David Park and George Wahlers

IEC Functional Safety Assessment. Project: K-TEK Corporation AT100, AT100S, AT200 Magnetostrictive Level Transmitter.

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relay CM-PFE

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

PROCESS AUTOMATION MANUAL. Universal Temperature Converter. KFD2-UT2-(Ex)*(-1) ISO9001

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Technical Data. Dimensions

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Basic Fundamentals Of Safety Instrumented Systems

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

FACTORY AUTOMATION MANUAL USB VIRTUAL COM PORT DRIVER INSTALLATION UNDER WINDOWS XP/WINDOWS 2000

GAE953 Electrical Alarm Unit 19" with Indicator

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Understanding Safety Integrity Levels (SIL) and its Effects for Field Instruments

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

MXa SIL Guidance and Certification

IEC Functional Safety Assessment. ASCO Numatics Scherpenzeel, The Netherlands

Final Element Architecture Comparison

CONFIGURABLE SAFETY RELAYS

A methodology For the achievement of Target SIL

CONFIGURABLE SAFETY RELAYS

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Machineontwerp volgens IEC 62061

FACTORY AUTOMATION MANUAL ID-NET SETUP PROCEDURE USING PROGRAMMING BARCODES

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Inductive slot sensor

FACTORY AUTOMATION. Manual. Speed Monitor KHU8-DW-1.D

Safety Requirements Specification Guideline

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Safety manual for Fisherr ED,ES,ET,EZ, HP, or HPA Valves with 657 / 667 Actuator

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

FUNCTIONAL SAFETY CERTIFICATE

Digital input modules

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

How To Use A Network Card With A Network Box (Ios) On A Microsoft Powerbook 2.5 (I2) (I3) (Io2) And I2 (Io) (Net) (Ipo) (

Pluggable interface relays CR-P Pcb relays

Technical Data. Dimensions

WORLDWIDE. GW400k SERIES MAINTENANCE MANUAL PROVEN PERIMETER PROTECTION

ABB industrial drives. Application guide ACS800-01/U1/04/04LC/04M/U4/11/U11/14/31/U31/104/104LC Safe torque off function (+Q967)

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Type testing

Instruction Manual Differential Pressure Transmitter

MINI MCR-SL-R-UI(-SP)

ABB Drives. User s Manual HTL Encoder Interface FEN-31

THEME Competence Matrix - Electrical Engineering/Electronics with Partial competences/ Learning outcomes

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives

Modular I/O System Analog and Digital Interface Modules

Rosemount 333 HART Tri-Loop

ISpac isolators. the perfect system

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

ACS-30-EU-EMDR-10-MOD

Multi-Protocol decoder with Load regulation

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Contents. Document information

PROCESS AUTOMATION MANUAL. Temperature Converter with Trip Values. KF**-GUT-(Ex)1.D ISO9001

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

IEC Overview Report

Safety Relays ESM/ESM-F

GREISINGER electronic GmbH

Certification Report of the STT25S Temperature Transmitter

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

High Availability and Safety solutions for Critical Processes

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Application Technique. Safety Function: Magnetic Door Switch Monitoring

SAFETY LIFECYCLE WORKBOOK FOR THE PROCESS INDUSTRY SECTOR

Transcription:

PROCESS AUTOMATION SAFETY MANUAL SIL Switch Amplifier KCD2-SR-(Ex)*(.LB)(.SP), HiC282* ISO9001 2

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

Contents 1 Introduction... 4 1.1 General Information...4 1.2 Intended Use...4 1.3 Manufacturer Information...5 1.4 Relevant Standards and Directives...5 2 Planning... 6 2.1 System Structure...6 2.1.1 Low Demand Mode of Operation...6 2.1.2 High Demand or Continuous Mode of Operation...6 2.1.3 Safe Failure Fraction...6 2.2 Assumptions...7 2.3 Safety Function and Safe State...8 2.4 Characteristic Safety Values...9 3 Safety Recommendation... 10 3.1 Interfaces...10 3.2 Configuration...10 3.3 Useful Life Time...10 3.4 Installation and Commissioning...12 4 Proof Test... 13 4.1 Proof Test Procedure...13 5 Abbreviations... 16 3

Introduction 1 Introduction 1.1 General Information This manual contains information for application of the device in functional safety related loops. The corresponding data sheets, the operating instructions, the system description, the Declaration of Conformity, the EC-Type-Examination Certificate, the Functional Safety Assessment and applicable Certificates (see data sheet) are integral parts of this document. The documents mentioned are available from www.pepperl-fuchs.com or by contacting your local Pepperl+Fuchs representative. Mounting, installation, commissioning, operation, maintenance and disassembly of any devices may only be carried out by trained, qualified personnel. The instruction manual must be read and understood. When a fault is detected within the device, it must be taken out of service and action taken to protect against accidental use. Devices shall only be repaired directly by the manufacturer. De-activating or bypassing safety functions or failure to follow the advice given in this manual (causing disturbances or impairment of safety functions) may cause damage to property, environment or persons for which Pepperl+Fuchs GmbH will not be liable. The devices are developed, manufactured and tested according to the relevant safety standards. They must only be used for the applications described in the instructions and with specified environmental conditions, and only in connection with approved external devices. 1.2 Intended Use The devices are available as safe area version (KCD2-SR-*(.LB)(.SP)) where they can be used as a signal conditioner providing isolation for non-intrinsically safe applications. Also the devices are available as hazardous area version (KCD2-SR-Ex*(.LB)(.SP), HiC282*) allowing use as isolated barriers for intrinsic safety applications. The safe area versions transfer digital signals (NAMUR sensors/mechanical contacts) via a galvanic isolation. The hazardous area versions transfer these signals from a hazardous to a safe area. The proximity sensor or switch controls a normally open relay output for the safe area load. The device output changes state when the input signal changes state. The normal output state can be reversed via DIP switches. In the KCD2-SR-(Ex)1.LB(.SP) versions, output II can be switched to either follow output I or to detect faults on the input line (line break, short circuit). Line fault detection (LFD) can be selected or disabled via a DIP switch. During an error condition the outputs de-energize. 4

Introduction A fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output. The KC devices are available with screw terminals or spring terminals. The type code of the versions of the KC-devices with spring terminals has the extension ".SP". The KCD2-SR-(Ex)*(.LB)(.SP) is a single device for DIN rail mounting while the HiC282* is a plug-in device to be inserted into a specific Termination Board. 1.3 Manufacturer Information Pepperl+Fuchs GmbH Lilienthalstrasse 200, 68307 Mannheim, Germany KCD2-SR-1.LB(.SP) KCD2-SR-Ex1.LB(.SP) KCD2-SR-2(.SP) KCD2-SR-Ex2(.SP) HiC2821, HiC2822 Up to SIL2 1.4 Relevant Standards and Directives Device specific standards and directives Functional safety IEC 61508 part 1 2, edition 2000: Standard of functional safety of electrical/electronic/programmable electronic safety-related systems (product manufacturer) Electromagnetic compatibility: - EN 61326-1:2006 - NE 21:2006 System specific standards and directives Functional safety IEC 61511 part 1, edition 2003: Standard of functional safety: safety instrumented systems for the process industry sector (user) 5

Planning 2 Planning 2.1 System Structure 2.1.1 Low Demand Mode of Operation If there are two loops, one for the standard operation and another one for the functional safety, then usually the demand rate for the safety loop is assumed to be less than once per year. The relevant safety parameters to be verified are: the PFD avg value (average Probability of Failure on Demand) and the T proof value (proof test interval that has a direct impact on the PFD avg ) the SFF value (Safe Failure Fraction) the HFT architecture (Hardware Fault Tolerance) 2.1.2 High Demand or Continuous Mode of Operation If there is only one loop, which combines the standard operation and safety related operation, then usually the demand rate for this loop is assumed to be higher than once per year. The relevant safety parameters to be verified are: the PFH value (Probability of dangerous Failure per Hour) Fault reaction time of the safety system the SFF value (Safe Failure Fraction) the HFT architecture (Hardware Fault Tolerance architecture) 2.1.3 Safe Failure Fraction The safe failure fraction describes the ratio of all safe failures and dangerous detected failures to the total failure rate. SFF = ( s + dd ) / ( s + dd + du ) A safe failure fraction as defined in EN 61508 is only relevant for elements or (sub)systems in a complete safety loop. The device under consideration is always part of a safety loop but is not regarded as a complete element or subsystem. For calculating the SIL of a safety loop it is necessary to evaluate the safe failure fraction of elements, subsystems and the complete system, but not of a single device. Nevertheless the SFF of the device is given in this document for reference. 6

Planning 2.2 Assumptions The following assumptions have been made during the FMEDA analysis: Only one input and one output are part of the considered safety function (only 2-channel version). The device shall claim less than 10 % of the total failure budget for a SIL2 safety loop. For a SIL2 application operating in Low Demand Mode the total PFD avg value of the SIF (Safety Instrumented Function) should be smaller than 10-2, hence the maximum allowable PFD avg value would then be 10-3. For a SIL2 application operating in High Demand Mode of operation the total PFH value of the SIF should be smaller than 10-6 per hour, hence the maximum allowable PFH value would then be 10-7 per hour. Failure rate based on the Siemens SN29500 data base. Failure rates are constant, wear out mechanisms are not included. External power supply failure rates are not included. The safety-related device is considered to be of type A components with a Hardware Fault Tolerance of 0. Since the loop has a Hardware Fault Tolerance of 0 and it is a type A component, the SFF must be > 60 % according to table 2 of IEC 61508-2 for a SIL2 (sub)system. It is assumed that the device will be used under average industrial ambient conditions, which are comparable with the classification "stationary mounted" in MIL-HDBK-217F. Alternatively, the following ambient conditions are assumed: IEC 60654-1 Class C (sheltered location) with temperature limits in the range of the manufacturer's specifications and an average temperature of 40 ºC over a long period. A moisture level within the manufacturer's specifications is assumed. For a higher average temperature of 60 ºC, the failure rates must be multiplied by a factor of 2.5 based on empirical values. A similar multiplier must be used if frequent temperature fluctuations are expected. It is assumed that any safe failures that occur (e.g., output in safe condition) will be corrected within eight hours (e.g., correction of a sensor fault). While the device is being repaired, measures must be taken to maintain the safety function (e.g., by using a replacement device). The indication of a dangerous fault (via fault bus) is detected within 1 hour by the programmable logic controller (PLC). 7

Planning 2.3 Safety Function and Safe State The safe state of each channel is "output de-energized", independent of the mode of operation. The safety function has two modes of operation: normal operation (output follows input) inverted operation (output inverts input) The one channel devices have two outputs where output II may be used in safety relevant applications if it is configured to follow output I. Therefore the DIP switch settings for all channels used in safety relevant applications are: DIP Switch Settings 1-channel Devices Function Mode KCD2-SR-(Ex)1.LB(.SP) HiC2821 Output I normal mode normal mode S1 position I S1 position II inverted mode S1 position II S1 position I Assignment output II follow output I S2 position I S3 position I LB/SC detection 1 S2 position II S3 position II Line fault detection ON S3 position I S2 position I OFF 2 S3 position II S2 position II 1 This mode may not be used if output II is used for safety relevant applications. 2 This switch setting may not be used if the device is used for safety relevant applications. Table 2.1 DIP Switch Settings 2-channel Devices Function Mode KCD2-SR-(Ex)2(.SP) HiC2822 Mode channel 1 normal mode S1 position I S1 position II inverted mode S1 position II S1 position I Mode channel 2 normal mode S2 position I S3 position II inverted mode S2 position II S3 position I Line fault detection channel 1 Line fault detection channel 2 ON S3 position I S2 position I OFF 1 S3 position II S2 position II ON S4 position I S4 position I OFF 1 S4 position II S4 position II 1 This switch setting may not be used if the channel is used for safety relevant applications. Table 2.2 LB/SC Diagnosis The input loop of all versions is supervised, if the line fault detection is active (mandatory, see data sheet). The related output goes to the safe state in case of line fault. 8

Planning Note! The failure outputs are not safety relevant. Reaction Time The reaction time for all safety functions is < 20 ms. 2.4 Characteristic Safety Values Parameters acc. to IEC 61508 Assessment type and documentation Values Full assessment Device type A Mode of operation Low Demand Mode or High Demand Mode HFT 0 SIL 2 Safety function One relay output of one channel Two relay outputs of a one channel device in series s 189 FIT 216 FIT dd 18 FIT 48 FIT du 47 FIT 45 FIT no effect 89 FIT 90 FIT total (safety function) 254 FIT 309 FIT not part 58 FIT 58 FIT SFF 81.55 % 85.4 % MTBF 1 365 years 311 years PFH 4.68 x 10-8 1/h 4.51 x 10-8 1/h PFD avg for T proof = 1 year 2.05 x 10-4 1.97 x 10-4 PFD avg for T proof = 2 years 4.10 x 10-4 3.95 x 10-4 PFD avg for T proof = 5 years 1.02 x 10-3 9.86 x 10-4 Reaction time 2 < 20 ms 1 acc. to SN29500. This value includes failures which are not part of the safety function. 2 Time between fault detection and fault reaction. Table 2.3 The characteristic safety values like PFD, SFF, HFT and T proof are taken from the SIL report/fmeda report. Please note, PFD and T proof are related to each other. The function of the devices has to be checked within the proof test interval (T proof ). 9

Safety Recommendation 3 Safety Recommendation 3.1 Interfaces The device has the following interfaces. For corresponding terminals see data sheet. 3.2 Configuration Safety relevant interfaces: KCD2-SR-(Ex)1.LB(.SP), HiC2821: input I, output I, output II KCD2-SR-(Ex)2(.SP), HiC2822: input I, input II, output I, output II Non-safety relevant interfaces: output ERR The device must be configured through the user accessible DIP switches for the required output function before the start-up. During the functionality any change of the operating function (DIP switch modification) can invalidate the safety function behavior and must be avoided. The KCD2 devices provide a suitable cover to protect against accidental changes while on the HiC devices the access to the DIP switch is permitted only through a small window on the side and by a small screw driver. 3.3 Useful Life Time Although a constant failure rate is assumed by the probabilistic estimation this only applies provided that the useful life time of components is not exceeded. Beyond this useful life time, the result of the probabilistic calculation is meaningless as the probability of failure significantly increases with time. The useful life time is highly dependent on the component itself and its operating conditions temperature in particular (for example, the electrolytic capacitors can be very sensitive to the working temperature). This assumption of a constant failure rate is based on the bathtub curve, which shows the typical behavior for electronic components. Therefore it is obvious that failure calculation is only valid for components that have this constant domain and that the validity of the calculation is limited to the useful life time of each component. It is assumed that early failures are detected to a huge percentage during the installation period and therefore the assumption of a constant failure rate during the useful life time is valid. However, according to IEC 61508-2, a useful life time, based on experience, should be assumed. Experience has shown that the useful life time often lies within a range period of about 8... 12 years. As noted in DIN EN 61508-2:2011 note NA4, appropriate measures taken by the manufacturer and operator can extend the useful lifetime. 10

Safety Recommendation Our experience has shown that the useful life time of a Pepperl+Fuchs product can be higher if there are no components with reduced life time in the safety path (like electrolytic capacitors, relays, flash memory, opto coupler) which can produce dangerous undetected failures and if the ambient temperature is significantly below 60 C. Please note that the useful life time refers to the (constant) failure rate of the device. Maximum Switching Power of Output Contacts The useful life time is limited by the maximum number of switching cycles under load conditions. The maximum number of switching cycles is depending on the electrical load and may be higher when reduced currents and voltages are applied. You can see the relationship between the maximum switching power and the load conditions in the diagrams below. I (A) 1 Resistive load DC 0.5 Electrical life max. 1 x 10 5 switching cycles 0.3 Electrical life max. 2.5 x 10 5 switching cycles 30 50 100 U (V) Figure 3.1 Maximum switching power of HiC282* I (A) 4 Resistive load DC Resistive load AC 2 1 0.5 0.4 Electrical life max. 1 x 10 5 switching cycles 0.15 20 30 50 100 200 40 115 253 U (V) Figure 3.2 Maximum switching power of KCD2-SR-(Ex)*(.LB)(.SP) 11

Safety Recommendation 3.4 Installation and Commissioning During installation all aspects regarding the SIL level of the loop must be considered. The safety function must be tested to ensure the expected outputs are given. When replacing a device, the loop must be shut down. In all cases, devices must be replaced by the same type. 12

Proof Test 4 Proof Test 4.1 Proof Test Procedure According to IEC 61508-2 a recurring proof test shall be undertaken to reveal potential dangerous fails that are otherwise not detected by diagnostic test. The functionality of the subsystem must be verified at periodic intervals depending on the applied PFD avg in accordance with the data provided in this manual. See chapter 2.4. It is under the responsibility of the operator to define the type of proof test and the interval time period. The ancillary equipment required: Digital multimeter with an accuracy better than 0.1 % For the proof test of the intrinsic safety side of the devices, a special digital multimeter for intrinsically safe circuits must be used. Intrinsically safe circuits that were operated with non-intrinsically safe circuits may not be used as intrinsically safe circuits afterwards. Power supply set at nominal voltage of 24 V DC The settings have to be verified after the configuration by means of suitable tests. Procedure: Sensor state must be simulated by a potentiometer of 4.7 k (threshold for normal operation), by a resistor of 220 (short circuit detection) and by a resistor of 150 k (lead breakage detection). The input test needs to be done for each input channel individually. The threshold must be between 1.4 ma and 1.9 ma, the hysteresis must be between 170 µa and 250 µa. For normal mode of operation the relay must be activated (yellow LED on), if the input current is above the threshold. For inverse mode of operation the relay must be activated (yellow LED on), if the input current is below the threshold. If the resistor R SC (220 ) or the resistor R LB (150 k ) is connected to the input, the unit must detect an external error. The red LED shall be flashing and the relay of the corresponding channel shall de-activate. Both relay outputs need to be tested with a certain current, i. e. 100 ma. To avoid any electrical shock problems, we recommend to use 24 V DC for this test. For the philosophy of Functional Safety it is important to test, that the relay contacts are definitely open, if the relay is de-activated. After the test the unit needs to be set back to the original settings for the current application. Further the switches for the settings need to be saved against undeliberate changes. This can be achieved by means of a (translucent) adhesive label, for HiC units across the hole where the switches are underneath, for KCD2 devices by fixing the label flap. 13

Proof Test KCD2-SR-Ex1.LB R SC R LB 1+ 2-5 6 240 R / 2.5 W 24 V DC 7 8 240 R / 2.5 W 24 V DC Zone 0, 1, 2 Div. 1, 2 Supply 9+ 10- I supply 24 V DC Power supply Zone 2 Div. 2 Figure 4.1 Proof test set-up for KCD2-SR-(Ex)1.LB(.SP) Usage in Zone 0, 1, 2/Div. 1, 2 only for KCD2-SR-Ex1.LB(.SP). KCD2-SR-Ex2 R SC R LB 1+ 2-5 6 240 R / 2.5 W 24 V DC R SC R LB 3+ 4-7 8 240 R / 2.5 W 24 V DC Zone 0, 1, 2 Div. 1, 2 Supply 9+ 10- I supply 24 V DC Power supply Zone 2 Div. 2 Figure 4.2 Proof test set-up for KCD2-SR-(Ex)2(.SP) Usage in Zone 0, 1, 2/Div. 1, 2 only for KCD2-SR-Ex2(.SP). 14

Proof Test Termination Board ( ma ) HiC2822 R SC R LB 1+ 4-11 14 240 R / 2.5 W 24 V DC ( ma ) R SC R LB 2+ 5-12 15 240 R / 2.5 W 24 V DC ( ma ) Zone 0, 1, 2 Div. 1, 2 Supply Bus Supply + Supply - I supply 24 V DC Power supply Zone 2 Div. 2 Figure 4.3 Channel 2 only for HiC2822. Proof test set-up for HiC2821, HiC2822 Tip Normally the easiest way to test H-System modules is by using a stand-alone HiCTB08-UNI-SC-SC Termination Board. The tester then has no need to disconnect wires in the existing application, so subsequent miswiring of the module is prevented. 15

Abbreviations 5 Abbreviations DCS ESD Distributed Control System Emergency Shutdown FIT Failure In Time in 10-9 1/h FMEDA s dd du no effect not part total (safety function) HFT MTBF MTTR PFD avg PFH PTC SFF SIF SIL SIS T proof Failure Mode, Effects and Diagnostics Analysis Probability of safe failure Probability of dangerous detected failure Probability of dangerous undetected failure Probability of failures of components in the safety path that have no effect on the safety function Probability of failure of components that are not in the safety path Safety function Hardware Fault Tolerance Mean Time Between Failures Mean Time To Repair Average Probability of Failure on Demand Probability of dangerous Failure per Hour Proof Test Coverage Safe Failure Fraction Safety Instrumented Function Safety Integrity Level Safety Instrumented System Proof Test Interval ERR LB LFD SC Error Lead Breakage Line Fault Detection Short Circuit 16

Notes 17

Notes 18

Notes 19

PROCESS AUTOMATION PROTECTING YOUR PROCESS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com For the Pepperl+Fuchs representative closest to you check www.pepperl-fuchs.com/contact www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany DOCT-1595H 09/2014