Dyeing Programmer DP - 01



Similar documents
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Failure code manual. content

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

GSM HOME SECURITY SYSTEM

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Multi-Range Programmable DC Power Supplies 9115 Series

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

SECTION 8 Heater Burnout Detection

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Multi-Range Programmable DC Power Supplies 9115 Series

BB-18 Black Body High Vacuum System Technical Description

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

How to read this guide

DS1621 Digital Thermometer and Thermostat

revolution Contents: Introduction Power 28-pin Project Board with input/output cables

Descriptive Technical Documentation. DTD no

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Technical Information

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

GSM Voice Auto Dialer & SMS Sender JC-999

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

User Manual. Humidity-Temperature Chart Recorder. Model RH520

GSMPBX version 1.3 Datasheet

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Programmer/Controller

A/C-HEATER SYSTEM - AUTOMATIC

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Operating Instructions. Single Loop Controller EC48 & EC96

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction

EScribe. EScribe at a glance

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

Innovative Electronics for a Changing World INDEX

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

CHAPTER 11: Flip Flops

DS Wire Digital Thermometer and Thermostat

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

BA Touch. Operating Instructions. Operation and Display Unit for systemp Temperature Controllers and Hot Runner Control Cabinets

Online UPS. PowerWalker VFI 1000R/1U

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

HyperAccess Access Control System

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

1.44 kw Programmable DC Power Supplies XLN Series

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

MP-4000 Alarm List (Software version or later)

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Variable Air Volume - VAV

Thermo Top - Troubleshooting Tree

Kendrick Astro Instruments

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

+ A B V B NO NC V COM PV PV

i 70 Installation Manual V1.04 Contents Grade 2 Wireless Intruder Alarm System YOUR SECURITY IS OUR PRIORITY Installation Instructions 2

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

NortechCommander Software Operating Manual MAN R6

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

Application Engineering

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Delta Temperature Controller User Manual

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

DS1621 Digital Thermometer and Thermostat

Flow Monitoring System

Electronic Control Devices The European Product Catalogue 2007

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

Brushless DC Motor Controller Product Specification Assembly 025F0129

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Operational Overview and Controls Guide

SA-9600 Surface Area Software Manual

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Inwall Room Temperature Unit

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

GSM home alarm system s manual

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Energy Division

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Sierra S-Series Smart Interface Software User Manual

SERVICE MANUAL REFRIGERATION

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

User Guide Reflow Toaster Oven Controller

ASTRONOMICAL TIME SWITCH NFC Supported AR-02D-NFC (2 x 10A)

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Transcription:

Dyeing Programmer DP - 01 Display and Controls. 1) Display: 16/2 alphanumeric display 2) Temperature range: 0 to 150 degree. 3) Resolution: 1 degree. 4) Accuracy: +/- 1 degree. 5) Temperature control setting: 0 to 150 degree in step of 1degree. 6) Rate of heating / cooling is adjustable from: 0.5 to 9.5 degrees/per minutes in step of 0.5 degree. 7) Process hold time display: 1 to 99 minutes in steps of 1 minute. 8) Forward and reverse time display: 1 to 99 minutes in step of 1 minute. 9) Alarm time display: 1 to 180 seconds in steps of 1 second. 10) Power supply: Input range 160-260 VAC. 11) Size of the panel cutout: 92x92. 12) Program memory: Up to 50 programs can be stored in the internal memory of DP-01. 13) Memory bank no. 1: This memory bank contains 50 programs from program no.1 to 50. In each program the user can provide maximum 25 steps. The parameter of the program can be changed as per the requirement of the user. These programs are stored in the memory even when the power is switched OFF. They can also be altered as and when required. 14) Output relays: A) Heat In. B) Cool In. C) Forward direction D) Reverse direction. E) Air In. F) Air Out. G) Alarm. Page 1 of 8

15) Power Consumption : 7.5 W 16) Weight: 1.5 kg: 17) Operating ambient temperature: 0 to 60 degree. 18) Temperature sensing probe: PT 100: 19) Keys and It s Function: a) key: This key is used to increase the value of the parameter whenever required or to check the temperature and its PT100 input when the instrument is in idle mode. b) key: The function of this key is to decrease the value of the parameter whenever required and to check the serial number, logged data and last technical error when the instrument is in idle mode. CURSOR c) : key enables to make a new program and to change the position of the cursor while editing the parameter. CODE d) OPC : This key allows the user to enter the password while saving a program. OPC is used to set the operator call whenever required and to acknowledge the same during the process. e) : This key enables the user to read and edit the special setting no.1, read the program and to change the step while editing a program. ALARM f) ACK. : This key acknowledges the alarm and read & edit the special setting No.2 when the instrument is in idle mode. g) ENT : This key is used to select a program, acknowledge the password and operator call. DELETE h) INCH : This key is used to delete a stage during the process and cancel an executed program. INCH is used to move the direction of beaker in an appropriate position after the process. EXC. i) HOLD : It is used to start a new program or previous executed program and put on hold the program during the process. RESET j) It is used to cancel any mode and stop an executed program. Page 2 of 8

20) Special setting No.1. Special setting can be edited by pressing the key. The following items can be set with the help of the same. a) FORWARD TIME: 0-99 minutes. Forward Time 03 Minutes (0-99) b) REVERSE TIME: 0-99 minutes: Reverse Time 03 Minutes (0-99) c) MOTOR OFF TIME: 0-99 seconds. Motor OFF Time 10 Seconds (0-99) These three parameters control the direction of the motor such as forward, reverse and pause time in between the directions. It is also possible to run the motor in a single direction if the parameter of the opposite direction is set at zero. d) AIR PRESSURE: 30-130 degree. Air Pressure 080 Deg. (30-130) This set parameter opens the air pressure valve when this parameter matches with the current temperature. Page 3 of 8

e) RESTART TIME: 0-180 Seconds. Restart Time 0-10 Secs. (0-180) This setting enables the automatic restart of the program in case of power failure. If the setting is kept at zero then the program has to be restarted manually during a power failure. f) Duration of the Alarm: 0-180 seconds. Alarm Time 010 Secs. (0-180) This setting controls the duration of the alarm when the programs advance to the next stage. The duration of the alarm for the operator call and the end of the program is fixed at 30 seconds. ALARM 21) Special Setting No. 2. With help of ACK. key. a) Over shoot control: (ON / OFF). Over Shoot Ctrl OFF (ON/OFF) b) Over shoot Offset: 0-10 Over Shoot Offset 05 (0-10) Degrees. This facility enables to control the temperature by switching ON the Cool In valve whenever overshoot takes place during the hold time. First select the overshoot control setting ON / OFF by pressing key and then select the offset of the same which is the set parameter of the Cool In valve to be operated. For example if the over shoot control is ON and the offset is set at five then whenever the temperature overshoots the set point by 5 degree during the hold time, the Cool In valve is set ON and brings down the temperature. Page 4 of 8

c) Proportional Band: 0-20 degree Proportional Band 00 (0-20) Degrees. d) Proportional Time : 5-30 Seconds Proportional Time 10 Seconds (5-30) This proportionate controller decreases the average power supplied to the heater as the temperature approaches set point. This ensures that it will not overshoot the set point and therefore will maintain a stable temperature. For example, if the PB is set at 5 degrees and PT is fixed for 20 seconds and target temperature is 100 degrees, the PB & PT will activate at 95 degrees. At this point, the ON time of the heating is 60% of PT and OFF time is 40%. This means an ON period of 12 seconds and off time of 8 seconds. When the temperature reaches 99 degrees, the ON time of the heating will be 40% and off time 60%. e) RS 485 address: 1-32. RS485 Address 01 (1-32) This facility is used for the RS 485 communication with PC. This is an address code for the computer. 32 instruments can be connected to one computer. For example, if this parameter is set at five then the computer easily communicates with this instrument by selecting the same value set in the computer. Page 5 of 8

22) Log Parameter Log parameter can be read by pressing key. a) Digital serial no: Each instrument has separate 16 digital serial numbers. b) Total executions started: It indicates the total number of programs executed so far. c) Total executions finished: It indicates the total number of programs finished. d) Total exec.time: It indicates the total execution time of the programs. e) Current ON time: This shows the ON time after currently switching ON this instrument. f) Total ON time: This indicates the total ON time of the instrument. g) Chip temperature: This enables to check the temperature inside the microcontroller. h) Chip DC voltage: This enables to check the input DC voltage of the microcontroller. i) Last program ended at: This indicates total time taken by the last executed program. j) Last error: This indicates the last technical error during the program such as power failure, PT100 open and short. k) Firmware: This shows the version number and the date of the same. l) Total power fail: It displays the total number of power failures during the process. 23) How To Make A New Program Whenever a new program is to be fed, the 01 0.0 00 000 CURSOR key is to be pressed. Wherever the cursor key is positioned that particular parameter is changeable. Edit the parameter by CURSOR pressing, / key. 01 0.0 05 060 After completing the first step press key to go to the next step. Change the parameter as mentioned at the first step.complete the entire steps as per your program and press SELECT PROGRAM & ENTER : 01 ENT key to save. Page 6 of 8

CODE OPC Select the program no. through / key in between 1to 25 and press C key. ENTER PASSWORD 996 Password of this instrument is 999 and selects the same value through / key and press ENT key to save. PROGRAM [01] SAVED 24) How To Read A Program Press ENT key and select the desired program through / key SELECT PROGRAM & ENTER : 05 After selecting the program No. press 05 01 1.5 05 080 ENT key again. Read the parameter by pressing key one by one. 25) How To Read A Program Press ENT key and select the desired program through / key SELECT PROGRAM & ENTER : 05 After selecting the program No. press 05 01 1.5 05 080 ENT key again. Read the parameter by pressing key one by one. 26) How To Start A New Program Press the ENT key and select the program through / key. SELECT PROGRAM & ENTER : 05 Page 7 of 8

After selecting the program No. press the 05 01 1.5 05 080 ENT key. The display will be as shown below. Then press pressing the EXC. HOLD EXC. HOLD key to start the program. It is also possible to start the previously executed program by key when instrument is in idle mode. 26) How To Cancel An Executed Program Press the RESET key. The display will be as follows. PROGRAM [05] WAS HALTED AT 00:00 Press the DELETE INCH key to cancel the program A.P.U ENTERPRISES MODEL DP-02 27) Wiring Diagram: SIX PINS CONNECTOR: 1) PHASE 2) NEUTRAL 3) EARTH 4) NIL 5) SENSOR S1 6) SENSOR S2 EIGHT PINS CONNECTOR: 1) HEAT IN 2) COOL IN 3) FORWARD 4) REVERSE 5) AIR IN 6) AIR OUT 7) ALARM 8) RELAY PHASE FUSE: 1 AMP. Page 8 of 8