Highly efficient flue gas analyzer



Similar documents
Measuring Instruments for Flue Gas and Emissions

The testo 340 What makes it The Ultimate Combustion Tuner?

Measurement Solutions for Refrigeration Technology.

Multifunction HVAC and IAQ Meter

Measurement data monitoring system

Committing to the future. Everything under control: With testo Saveris TM, measurement data are under control everywhere.

Temperature measuring. instruments. Flue gas analysers. Pressure measuring. instruments. Gas detectors

Measuring Instruments For Temperature

Measurement Engineering for Air Conditioning and Ventilation

Engine test rig 4. SN: /008 Tuning AG Munich. Sports car 911. Cleanroom QS / m/s C hpa

Measurement data monitoring system testo Saveris.

Test equipment for temperature and its reduction

Portable digital microprocessor thermometers with interchangeable probes

Hand-held thermometer Model CTH7000

Measurement data monitoring system testo Saveris.

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

TurbiDirect TurbiCheck TurbiCheck WL

Online Infrared Flue Gas Analyzer Gasboard 3000

Compact ph Measuring Instruments

testo easyheat Configuration and Analysis software Instruction manual

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Emission Testers. for Diesel, Gasoline and Gas Engines. Model: MET 6.3 MET 6.1 MET 6.2 Export MDO2 LON MGT5 DITEST SPEED 2000 RPM VC2

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Take total control of your HVAC system with cost-saving flow and thermal energy meters

C/ F. m/s %RH. MPa CO 2

Dual Laser InfraRed (IR) Thermometer

Unmatched Metal Hardness Testing

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

OT 40L / 90L. Laboratory Steam Sterilizers

Instruction Manual Dräger MSI ALV

Material test chamber with mechanical convection

Milwaukee USER MANUAL

Printers and Barcode Scanners

Data Logging Solutions from Lascar Electronics

GREISINGER electronic GmbH

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Software Features of Auto Gas Gas Analyzer Features HC, CO, CO2, Lambda, Air Fuel, NOx. Has optional RPM and Oil Temp.

CORESTA RECOMMENDED METHOD Nº 81

DISSOLVED OXYGEN METER Model : DO-5509

CO Low CO High O 2 NO NO 2 NOx SO 2 H 2 S CxHy CO 2 LANCOM III

Instruction manual. testo easyheat Configuration and Analysis software

Battery Powered Thermal Mass Flow Meters for Gases

Melting Point Apparatus

Thermal Flow Sensor Die

PAT Tester Printers and Barcode Scanners

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Thermal environments. Tel

Battery Powered Digital Mass Flow Meters for Gases

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

E420 SHAFT ALIGNMENT. Entry level measurement and alignment system for rotating machines BUILT-IN WIRELESS UNITS LARGE COLOUR DISPLAY QUICK START

Incubator with mechanical convection

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

MESSKO MLog. The MESSKO MLog on a mission

Fire & Security DETECTORS

USB-500/600 Series Low-Cost Data Loggers and Accessories

Heating oven with mechanical control

Tools & Equipment Robinair

rigel 288 Electrical Medical Safety Analyser Key Features Applications

Temperature, hygrometry, CO and CO 2. probes for class 310 transmitters

AC Service Equipment ACE 21 EXPERT. Fully automatic service station. R-1234yf refrigerant. Made in Germany

BOD measurement. BOD measurements. Respiration. Biological Oxygen Demand. Depletion/Respiration

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

COMBIMASS. Technical Data COMBIMASS eco-bio +

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

TR Series Surface Roughness Tester for workshop and laboratory

Battery Powered Thermal Mass Flow Meters for Gases

DUST EMISSION MONITORING SYSTEM

GX-2009 Data Logger Management Program Operator s Manual

Portable Hardness Tester

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

This datalogger is ideal for the Food Industry where process profiling is crucial to production efficiency and energy use optimisation.

USB-500 Series Low-Cost Data Loggers and Accessories

ATL Fuel Level Sender Probes

How To Use A Flowmeter

RTD Temperature Probe for the Food/Pharmaceutical Industry

Car and commercial cial air conditioning service solutions

Typical Aluminum GFM Mass Flow Meter

WEATHER STATION FOR SOLAR FARM MONITORING

Dual Laser InfraRed (IR) Thermometer

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

for CS flow / dew point sensors

Hygro-Thermometer + InfraRed Thermometer Model RH101

User Manual. SenseAir Alarm. Portable carbon dioxide sensor and alarm unit for personal safety with Real Time Clock

Diagnostics Tools. for All Makes of agricultural machinery

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

Heating, air-conditioning, cooling

Heating oven with mechanical convection

Instruction Manual FL

The Ambient Air Monitoring System

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

How To Use A Ds340 (Dsp)

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Transcription:

Highly efficient flue gas analyzer testo 320 Just a few clicks away from a heating system diagnosis O 2 High-resolution colour graphic display Quick and easy menu structure Storage space for 500 measurement values Measurement of flue gas, draught, pressure, ambient CO, differential temperature and gas leak detection O 2 and CO sensor and flue gas probe with temperature probe TÜV-tested according to EN 50379, Parts 1-3 CO 2 CO HPA QA ETA C The new testo 320 is a high-quality measuring instrument for efficient flue gas analysis. Its wide measuring range makes it a reliable partner for eliminating malfunctions and emergencies, monitoring legal limit values or for daily routine work servicing heating systems. The numerous measurement menus of the testo 320 are clearly structured. Standarized menu procedures, which are stored in the instrument specifically for your country, simplify operation depending on which standards you are dealing with. The high-resolution display allows a detailed presentation of the measurement procedures and is easily legible even under the worst conditions. www.testo.com

Product properties High-resolution colour graphic display The measurement menus and measurement values are presented in detail and always easily legible. Sensor monitoring Integrated traffic light system which continuously monitors the sensor functionality. Fast sensor zeroing Automatic zeroing of the sensor in only 30 seconds after start-up, and which can be cancelled if not required. Sensors exchangeable by the user Easy exchange of sensors by the user no adjustment necessary. Memory Up to 500 measurement protocols can be saved and called up in the memory of the testo 320. Lithium battery Operation with a Lithium battery (1500mAh) no battery change necessary, up to eight hours running time, charging via USB connection possible. Attachment Integrated magnets for fast attachment to burner/boiler.

Stamp of approval The flue gas analyzer testo 320 is TÜV-tested according to EN 50379, Parts 1-3. Robust design Robust, durable instrument ideally suited even to rough surroundings. Condensate trap Integrated condensate trap very easily emptied. Efficient exchange of probes Fast and easy exchange of probes via the probe coupling. All gas paths are connected to the instrument at once with the bayonet connection. Probe filter Easy exchange of probe filter. Flexibility with modular probes A range of probe lengths and diameters ensure a high degree of flexibility for all applications. To exchange the probe shaft, it is simply placed on the probe handle and engages.

Ordering data / Accessories testo 320 set for chimneysweeps 0632 3220 testo 320 with H2-compensated CO sensor and Bluetooth 0554 1105 USB mains unit 0600 9761 Flue gas probe modular (length 300 mm, Ø 8 mm) 0600 9787 Combustion air probe (length 190 mm) testo 320 set for heating constructors 0632 3220 testo 320 with H 2 -compensated CO sensor 0554 1105 USB mains unit 0516 3300 System case (height: 130 mm) 0554 0549 Testo fast printer IRDA 0600 9741 Compact flue gas probe (length 300 mm, Ø 6 mm) 0600 9787 Combustion air probe (length 190 mm) Measuring instrument with options testo 320 flue gas analyzer, incl. O 2 sensor, calibration protocol, graphic display 0632 3220 Option CO sensor without H 2 -compensation Option H 2 -compensated CO sensor Option CO low sensor Bluetooth option Spare gas sensors Spare sensor O 2 for testo 320 Spare CO sensor (without H 2 -compensation) for testo 320 Spare CO sensor H 2 -compensated for testo 320 Spare CO low sensor for testo 320 0393 0005 0393 0053 0393 0105 0393 0103 Smoke tester with oil and soot sheet, for measuring soot in flue gas, excl. cone (part no. 0554 9010) Testo Bluetooth /IRDA printer incl. 1 roll of printer paper, rechargeable battery and mains unit Testo fast printer IrDA with wireless infrared interface; 1 roll thermal paper; 4 AA batteries Spare thermal paper for printer, permanent ink PC analysis software easyheat, for presenting measurement procedures as diagrams, tables and for managing customer data USB mains unit incl. cable Spare battery Instrument case (height: 130 mm) for instrument, probes and accessories Instrument case with double base (height: 180 mm) for instrument, probes and accessories ISO calibration certificate/flue gas 0554 0307 0554 0620 0554 0549 0554 0568 0554 3332 0554 1105 0515 0046 0516 3300 0516 3301 0520 0003

Probes Compact basic flue gas probes Flue gas probe compact; length 180 mm; Ø 6 mm; Tmax. 500 C; probe stop; NiCr-Ni thermocouple, 2.2 m hose and particle filter included Flue gas probe compact; length 300 mm; Ø 6 mm; Tmax. 500 C; probe stop; NiCr-Ni thermocouple, 2.2 m hose and particle filter included 0600 9740 0600 9741 Modular flue gas probes Flue gas probe modular, incl. cone for attachment; thermocouple NiCr-Ni; hose 2.2 m; particle filter; length 180 mm; Ø 8 mm; Tmax. 500 C; TÜV-tested Flue gas probe; length 300 mm; Ø 8 mm; Tmax. 500 C; TÜV approval; probe stop; NiCr-Ni thermocouple; 2.2 m hose and particle filter included Flue gas probe; length 180 mm; Ø 6 mm; Tmax. 500 C; probe stop; NiCr-Ni thermocouple; 2.2 m hose and particle filter included Flue gas probe; length 300 mm; Ø 6 mm; Tmax. 500 C; probe stop; NiCr-Ni thermocouple; 2.2 m hose and particle filter included Flue gas probe flexible; thermocouple NiCr-Ni; hose 2.2. m; dirt filter; length 330 mm; Ø 9 mm; Tmax. 180 C; short-term 200 C; ideal for measuring at inaccessible points 0600 9760 0600 9761 0600 9762 0600 9763 0600 9770 Probe accessories Probe shaft; length 180 mm; 8 mm; Tmax. 500 C Probe shaft; length 300 mm; Ø 8 mm; Tmax. 500 C Probe shaft flexible; length 330 mm; Ø 9 mm; Tmax. 180 C Probe shaft multi-hole; length 300 mm; Ø 8 mm; for mean CO calculation Probe shaft multi-hole; length 180 mm; Ø 8 mm; for mean CO calculation Hose extension; 2.8 m; extension cable for probe Hose connection set with adapter for separate gas pressure measurement Spare dirt filter, modular probe; 10 off Spare particle filter, compact probe; 10 off 0554 9760 0554 9761 0554 9770 0554 5762 0554 5763 0554 1202 0554 1203 0554 3385 0554 0040

Probes Additional probes Dual wall clearance probe for O 2 supply air measurement Gas leak detection probe; 0 to 10000 ppm CH 4 /C 3 H 8 Ambient CO probe, for detecting CO in buildings and rooms; 0 to +500 ppm Ambient CO 2 probe, Plug-in head, connection cable 0430 0143 or 0430 0145 required Differential temperature set; consisting of 2 Velcro probes and temperature adapter Fine pressure probe: highly accurate probe for the measurement of differential pressure and temperature, as well as Pitot tube measurement of flow velocities (see technical data) Capillary hose set for 4 Pa measurement 0632 1260 0632 3330 0632 3331 0632 1240 0554 1208 0638 0330 0554 1215 Combustion air temperature probes Combustion air temperature probe, immersion depth 300 mm Combustion air temperature probe, immersion depth 190 mm Combustion air temperature probe, immersion depth 60 mm 0600 9791 0600 9787 0600 9797 Additional temperature probes Mini ambient air probe; for separate ambient air temperature measurement; 0 to +80 C Very fast reaction surface probe Connection cable 0600 3692 0604 0194 0430 0143

Technical data Measuring range Accuracy ±1 digit Resolution Temperature -40 to +1200 C ±0.5 C (0 to +100.0 C) ±0.5 % of m.v. (remaining range) Draught measurement Pressure measurement -9.99 to +40 hpa ±0.02 hpa or ±5% of m.v. (-0.50 to +0.60 hpa) ±0.03 hpa (+0.61 to +3.00 hpa) ±1.5% of m.v. (+3.01 to +40.00 hpa) 0 to +300 hpa ±0.5 hpa (0.0 to 50.0 hpa) ±1% of m.v. (50.1 to 100.0 hpa) ±1.5 % of m.v. (remaining range) 0.1 C (-40 to +999,9 C) 1 C (> +1000 C) 0.01 hpa with fine draught option 0.001 hpa 0.1 hpa with fine draught option 0.01 hpa O 2 measurement 0 to 21 Vol. % ±0.2 Vol. % 0.1 Vol. % 20 s Adjustment time t 90 CO measurement (without H 2 -compensation) CO measurement (H 2 -compensated) Determination of degree of effectivity (Eta) 0 to 4000 ppm ±20 ppm (0 to 400 ppm) ±5% of m.v. (401 to 2000 ppm) ±10% of m.v. (2001 to 4000 ppm) 1 ppm 60 s 0 to 8000 ppm ±10 ppm or ±10% of m.v. (0 to 200 ppm) 1 ppm 40 s ±20 ppm or ±5% of m.v. (201 to 2000 ppm) ±10% of m.v. (2001 to 8000 ppm) 0 to 120% 0.1% Flue gas loss 0 to 99.9% 0.1% ±0.2 Vol. % 0.1 Vol. % CO 2 determination Display range 40 s digital calculation from O 2 0 to CO 2 max Option CO low measurement (H 2 -compensated) 0 to 500 ppm ±2 ppm (0 to 39.9 ppm) ±5% of m.v. (remaining range) 0.1 ppm 40 s Ambient CO measurement (with CO probe) Gas leak measurement for flammable gases (with gas leak detection probe) Ambient CO 2 measurement (with ambient CO 2 probe) 0 to 500 ppm ±5 ppm (0 to 100 ppm) ±5% of m.v. (> 100 ppm) Display range 0 to 10.000 ppm CH 4 / C 3 H 8 0 to 1 Vol. % 0 to 10.000 ppm Signal optical display (LED) audible signal via buzzer ±50 ppm or ±2% of m.v. (0 to 5000 ppm) ±100 ppm or ±3% of m.v. (5001 to 10000 ppm) 1 ppm 2 s Differential pressure, flow velocity and temperature via fine pressure probe ±10.000 Pa 0.15 to 3 m/s max. -40 to +1,200 C (dependent on probe) ±0.3 Pa (0 to 9.99 Pa) plus ±1 Digit ±3% of m.v. (10 to 10.000 Pa) plus ±1 Digit ±0.5 C (-40 to 100 C) ±0.5 % of m.v. (rem. measuring range) plus probe accuracy 0.1 m/s 0.1 C General technical data Storage temperature -20 to +50 C Operating temperature -5 to +45 C Display Weight Colour graphic display 240 x 320 pixels 573 g Power supply Memory Battery: 3.7 V / 2,400 mah Mains unit: 6 V / 1.2 A 500 measurement values Dimensions Warranty 240 x 85 x 65 mm Instrument/probe/gas sensors: 24 months Battery: 12 months

Subject to change without notice. 0981 2884/msp/A/05.2015 www.testo.com