LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

Similar documents
Hands on an infrared gas analyzer (IRGA) to measure photosynthesis

Online Infrared Flue Gas Analyzer Gasboard 3000

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

Effects of Temperature, Pressure and Water Vapor on Gas Phase Infrared Absorption by CO 2

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

The ultra compact photosynthesis system

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

High Power Programmable DC Power Supplies PVS Series

Instrumentation for the Plant & Soil Sciences Short Form Catalog

- 1 - BISC 367 Plant Physiology Laboratory SFU

How To Use A Ds340 (Dsp)

Typical Aluminum GFM Mass Flow Meter

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Gas sensors for greenhouse measurements

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Research RF Sputtering Packages

Fundamentals of Mass Flow Control

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Multi-Range Programmable DC Power Supplies 9115 Series

Vibration analysis and monitoring Compact. Powerful. Modern technology.

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Micro Motion 3098 Gas Specific Gravity Meter

How To Use An Irius Pid Detector

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

PIEZOMETER AIRFLOW MEASURING RING

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

CIRAS-2 Portable Photosynthesis System For Research

Wireless Data Logger Monitoring Systems

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Measuring Laser Power and Energy Output

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Residual Gas Analyzers

Physical Specifications (Custom design available.)

Perimeter Security System

INTREPID Perimeter Intrusion Detection System

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

1.44 kw Programmable DC Power Supplies XLN Series

PRODUCT PROFILE FEATURES

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

REAL-TIME DUST AND AEROSOL MONITORING

Impedance 50 (75 connectors via adapters)

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

How To Choose A Total Organic Carbon Analyzer

Air Pollution Control Division. Technical Services Program

Dew-Point Measurement Solutions

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Nederland België / Belgique

Highly efficient flue gas analyzer

One Port Network Analyzer

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Multi-Range Programmable DC Power Supplies 9115 Series

Rackmount Intelligent Pressure Scanners

O C M III. Open Channel Flow Monitor

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

RGC-IR Remote Gas Calibrator for IR400

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Current Monitoring Kit

EFC Frequency converters

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

The Sievers 900 Series TOC Analyzers

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Laser Diode Gas Sensors

The Ambient Air Monitoring System

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

CO 2 Gas Sensor. (Order Code CO2-BTA or CO2-DIN)

The testo 340 What makes it The Ultimate Combustion Tuner?

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Galvanic Parts Per Million Dissolved Oxygen Systems

Series DFMT Digital Paddlewheel Flowmeter

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Trace Gas Exchange Measurements with Standard Infrared Analyzers

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Battery Powered Digital Mass Flow Meters for Gases

AMTRON E-30 Compact heat and cooling meter

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

AC3200 INTELLIGENT BROADBAND AMPLIFIER

DCS Series 1 kw, 1.2 kw, & 3 kw

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Uninterruptible Power Supply

Contents. Document information

FREQUENCY RESPONSE ANALYZERS

XP Series Balances Operation Manual

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

WEATHER STATION FOR SOLAR FARM MONITORING

Nardalert S3 Non-Ionizing Radiation Monitor

Transcription:

LI-7000 CO /H O Analyzer 2 2 High Speed, High Precision Differential Analyzer

LI-7000 CO 2 /H 2 O Analyzer - Advantages... Page 1 The LI-7000 CO 2 /H 2 O Analyzer The LI-7000 is a high performance, dual cell, differential gas analyzer. It uses a dichroic beam splitter and two separate detectors to measure infrared absorption by CO 2 and H 2 O in the same gas stream. At the heart of the LI-7000 is an innovative optical bench that can be dismantled and cleaned by the user without the need for factory recalibration. The LI-7000 also features: Large diameter air inlet and outlet ports that virtually eliminate back pressure, even at flow rates of 10 l/min Direct connection of air fittings to the optical bench eliminates diffusive leaks Durable sapphire optical bench windows which are extremely hard and scratch resistant Built-in pressure sensor with 0.1% accuracy, for automatic compensation for pressure changes in the sample cell Built-in auxiliary pump can be used for either sample or reference cell Intelligent diagnostic indicators warn of potential problems before data are compromised Real-time charting The LI-7000 is ideal for a variety of high speed, high precision differential projects.

LI-7000 CO 2 /H 2 O Analyzer - Applications... Page 2 Applications Flexibility The LI-7000 is ideally suited for applications that demand high speed, high precision measurements in absolute and/or differential modes, including plant gas exchange using chamber-based methods, atmospheric-surface flux eddy covariance and Bowen ratio techniques, vertical profiling, and general atmospheric monitoring. The cleanable optics and software functions such as integration and peak detection operations are important features for applications such as the measurement of dissolved CO 2 (pco 2 ), and Total Organic Carbon (TOC) in aqueous samples. The LI-7000 s inherent stability and wide operating temperature range make it well suited for the rigorous demands of cross-sectional measurements of plumes from point sources such as volcanoes, geothermal degassing locations, or industrial sites. Atmospheric Monitoring Animal Respiration Industrial Monitoring Greenhouse Applications Insect Respiration Soil CO 2 Flux Measurements Growth Chamber Applications Photosynthesis and Transpiration Studies Plant Physiology Oceanographic Studies (pco 2 and TOC) For Eddy Covariance Analyzers, visit www.licor.com/ec-analyzers

LI-7000 CO 2 /H 2 O Analyzer - Technology... Page 3 User accessible module allows for cleaning of gas measurement cells Long life, tungsten filament source Chopping shutter disk for increased sensitivity Nickel-plated optical cells Internal chemicals are easily replaced Built-in pressure sensor Detectors measure CO 2 and H 2 O vapor in the same air stream Technology Design features that contribute to the LI-7000 performance are: A long life (>5 years), vacuum sealed tungsten filament source. This source has low power consumption, and is highly stable. Nickel-plated optical cells to minimize water sorption. The optical cells can be removed and cleaned with compressed air or water, and reassembled without requiring factory recalibration. CO 2 and H 2 O detectors simultaneously measure CO 2 and H 2 O vapor in the same air stream. Digital Signal Processing immediately digitizes the signal from the detectors. All further signal processing is in the digital domain to avoid analog component drifts. A spinning chopper shutter disk allows for radiation to alternately pass through each gas sampling cell. The rotation of the disk is precisely controlled at a high chopping frequency, which reduces sensitivity of the detector to low frequency vibrations. This results in lower analyzer noise, fast response, and increased sensitivity. Modular components in user accessible areas of the analyzer provide a simple method of cleaning the gas sampling cells and changing internal chemicals to minimize the need for factory service. Two auxiliary input channels (10 Hz band width) which can be used to input an analog signal from an external sensor. CO 2 and H 2 O references may be input through these channels. Four fully configurable digital-to-analog converters (DACs) which are updated at 600 Hz provide output signals that are directly proportional to gas concentration or other meaningful units. Both USB and RS-232 interfaces are provided for data output at rates of up to 50 Hz.

LI-7000 CO 2 /H 2 O Analyzer - Technology... Page 4 AC or DC Power Built-in air pump for scrubbng the reference cell Serial data output at rates up to 50 Hz Large diameter inlet ports allow high flow rates and eliminate diffusive leaks USB data output rate up to 50 Hz Auxiliary input and analog output channels connect to detachable terminal strips Operational Overview The LI-7000 is a differential analyzer, in which a gas of known concentration (which can be zero) is put in the reference cell (A), and an unknown gas is put in the sample cell (B). The instrument software provides continuous output of the absolute concentration in the sample cell as well as the differential concentration. The infrared source provides radiation through both optical paths, which is directed to CO 2 and H 2 O detectors. Internal chemicals keep the detector and chopper housings free of CO 2 and H 2 O vapor. H 2 O Filter H2O Detector CO 2 Detector CO 2 Filter Dichroic Beam Splitter Soda Lime/Desiccant Bottles Cell A or B Chopper Motor Housing Chopping Shutter Aperture Mirror Source Lens Window Window Lens

LI-7000 CO 2 /H 2 O Analyzer - Software... Page 5 Software Windows Interface Simple PC-compatible software for Windows provides easy access to all instrument functions, including calibration, data output options, and the display of output variables. The main window allows for viewing real-time data in text or graphical form. Any software communications program capable of sending command strings and receiving ASCII data can be used to communicate with the LI-7000. All instrument functions can also be accessed at the LI-7000 front panel. Custom displays with up to 8 variables, updated in real time, are available on the LCD. Screen Display Output variables are presented in real-time text or graphical forms with a simple Windows interface. The LI-7000 has a 40 character x 8 line backlit LCD that displays real-time measured values. The variables to be displayed are chosen from a list, and as many as 8 can be viewed on a single display screen. Different screens can be programmed and accessed quickly by pressing a single numeric key on the keypad. More than 50 different measured and diagnostic variables, including CO 2 and H 2 O measurements as mole fraction, partial pressure, dew point (H 2 O), or raw absorptance values are available for display. Measured variables can be automatically integrated using built-in integration functions. The display can be quickly toggled between text and graphics modes, where measured or computed variables can be viewed in real time. Up to 3 sets of plots can be defined and stored, with as many as 3 plots per graph set. The LCD display has adjustable backlighting and contrast settings.

LI-7000 CO 2 /H 2 O Analyzer - Ordering Information... Page 6 Ordering Information LI-7000 CO 2 /H 2 O Gas Analyzer Includes external battery leads, scrubber tube, AC power cord, RS-232 serial cable, USB cable, Windows Interface Software and factory calibration. LI-7000DP Special pricing package, includes the LI-7000 CO 2 /H 2 O Gas Analyzer and the LI-610 Dew Point Generator, which can be used to calibrate the water channel of the LI-7000. LI-610 Portable Dew Point Generator Includes 610-01 AC Module and 610-04 BNC to mv Recorder Leads. Eddy Covariance Analyzers LI-COR offers additional high speed, high precision analyzers which are ideal for measuring ecosystem gas exchange. For more information on these analyzers, visit: www.licor.com/ec-analyzers LI-7500A Open Path CO 2 /H 2 0 Analyzer The LI-7500A is an open path, high speed, high precision, non-dispersive infrared gas analyzer that accurately measures densities of carbon dioxide and water vapor in situ. With the eddy covariance technique, these data are used in conjunction with sonic anemometer wind speed to determine the fluxes of CO 2 and H 2 O into and out of ecosystems. The LI-7500A and LI-7200 (below) accept analog data from a sonic anemometer and log complete data sets to a removable USB storage device. LI-7200 Enclosed CO 2 /H 2 O Analyzer The LI-7200 is a compact, enclosed CO 2 /H 2 O analyzer that combines the benefits of open and closed path gas analyzers. It is an integrated system designed to provide continuous measurements in harsh weather conditions and environments, with very low power consumption. LI-7700 Open Path CH 4 Analyzer: The open path design of the LI-7700 provides solutions to many of the challenges of measuring atmospheric CH 4 flux over various ecosystems, while providing excellent cospectra. No external pumps or tubing are required, and low power requirements for the entire system enable the LI-7700 to be powered with solar panels in remote locations (~ 8W during normal operation). Self-cleaning optics provide low maintenance requirements and more robust data.

LI-7000 Specifications Type: Differential, non-dispersive infrared gas analyzer. Detectors: Two solid state detectors; one each for CO 2 and H 2 O, filtered with center wavelengths at 4.255 and 2.595 microns, respectively. Chopping Frequency: 600 Hz. Source: Single source, lifetime > 5 years. Optical Bench: One optical bench. Sample cell size: 9.53 mm Dia. 152.4 mm L (3/8" 6"). Volume: 10.86 cm 3. Warm-up Time: Approximately 2 minutes to operation. Gas Pressure: Maximum allowable pressure is 115 kpa (17 psi) with pressure sensor connected. 200 kpa (29 psi) max. w/o pressure sensor connected. Maximum Flow through Analyzer: >50 liters/min. Internal Pump Max Flow Rate: Approximately 1 liter/minute. Display: 40 character 8 line backlit LCD. Back Panel Connections: Analog: 4 user-scalable DAC's, 600 Hz update frequency (±5V maximum, 14-bit). RS-232: 9600 to 115,200 baud. USB: Data output rate up to 50 Hz. USB 2.0 compliant. Auxiliary Input Channels: 2, -2.5 to +2.5V. Common mode input voltage range ±2.5V. Power Requirements: 100-240 VAC, 50-60 Hz, or 10.5-16 VDC, 4 amp max. Power Consumption: 15-40 Watts DC (dependent on temperature and pump usage). Temperature Range: 0-50 C ambient, 0-55 C bench. Size: 5" H 9.875" D 14.5" L (12.7 25 36.8 cm). Weight: 19.4 lbs. (8.8 kg). CO 2 Analyzer Specifications Range: 0-3000 μmol/mol. Accuracy: 1% nominal. Zero Drift (with temperature): <0.1 μmol/mol/ C. Span Drift: <0.2% of reading/ C. Water Sensitivity: <0.1 μmol/mol CO 2 /mmol/mol H 2 O (Software algorithm corrects for band broadening effects). Calibration: Factory linearization over 0-3000 μmol/mol range using NIST-traceable standard gases. Pressure Range: 0 to 115 kpa absolute. Display Resolution:.01 μmol/mol. Signal Noise: See table below. H 2 O Analyzer Specifications Range: 0-60 mmol/mol. Optical bench and interconnecting hoses must be maintained above the dewpoint temperature by the user. Accuracy: 1%. Zero Drift: <0.1 mmol/mol/ C. Span Drift: <0.4% of reading/ C. Signal Noise: See table below. Calibration: LI-610 Dew Point Generator Noise Specifications (Typical) CO 2 (370 μmol/mol) H 2 O (10 mmol/mol) Average Time (s) Bandwidth (Hz) RMS Noise (ppb) Peak-to-Peak (ppb) RMS Noise (ppm) Peak-to-Peak (ppm) 20 0.025 6 39 0.4 3 1 0.5 25 173 2 12 0.5 1 35 245 2 17 0 20 157 1096 11 75 LI-COR Biosciences 4647 Superior Street P.O. Box 4425 Lincoln, Nebraska 68504 North America: 800-447-3576 International: 402-467-3576 FAX: 402-467-2819 envsales@licor.com envsupport@licor.com www.licor.com In Germany LI-COR GmbH: +49 (0) 6172 17 17 771 envsales-gmbh@licor.com envsupport-gmbh@licor.com In UK, Ireland, and Scandinavia LI-COR Biosciences UK Ltd.: +44 (0) 1223 422102 envsales-uk@licor.com envsupport-uk@licor.com 6/2011 980-07980 The LI-COR board of directors would like to take this opportunity to return thanks to God for His merciful providence in allowing LI-COR to develop and commercialize products, through the collective effort of dedicated employees, that enable the examination of the wonders of His works. Trust in the LORD with all your heart and do not lean on your own understanding. In all your ways acknowledge Him, and He will make your paths straight. Proverbs 3:5,6