Technical Overview CM-16 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk



Similar documents
Technical Overview CM-2 Climate Monitor. Get yours direct at:

Product Guide CM-Relay

Instruction Manual Environmental Monitoring Unit. Watchdog 1000 Series Firmware Version 3

Instruction Manual Environmental Monitoring Unit. RSMINI-P, RSMICRO, RSMINI163 Firmware Version 3

Instruction Manual Environmental Monitoring Unit. Watchdog 1200 Series Firmware Version 3

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

Computer Cabinet Environment Monitor

Panduit PViQ Switched POU User Manual

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

PE6108/PE6208/PE8108/PE8208

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

securityprobe 5E Standard

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

3.5 EXTERNAL NETWORK HDD. User s Manual

Dominion PX. General Questions. What is Dominion PX (PX)?

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

HWg-STE HWg-STE PoE MANUAL

Olson Electronics Remote Power Monitoring Meter

NMS300 Network Management System

Power Supply SNMP Interface User Manual for SRL versions

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

Sensatronics Senturion Environmental Monitor Operations Manual

Emerson Smart Firewall

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

Zertico Rack Monitoring Unit

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

Environmental Management System

Instruction Manual Rack Power Distribution Unit. RCX, RCM-O and RCU-O Series Firmware Version 3

M O N I T O R I N G S O L U T I O N S INFRASTRUCTURE MANAGEMENT SOLUTIONS. Varicontrol-P. The Integrated Rack Management System

securityprobe5es -X20

1 Serial RS232 to Ethernet Adapter Installation Guide

The complete environmental monitoring system for your data center.

ROOM GUARD VT300. Environmental Infrastructure monitoring

SNMP Web Management. User s Manual For SNMP Web Card/Box

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

Chapter 3 Management. Remote Management

Chapter 4 Management. Viewing the Activity Log

Aolynk DR814Q ADSL2+ Broadband Router Quick Start

ECB1220R. Wireless SOHO Router/Client Bridge

PN5212/PN5320/PN7212/PN7320

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

Light Level. Sensor. Accessory Device Connector. Serial Connector. Lamps. Temperature and Air Flow. Humidity. Sensor I/O Ports (terminals) Sensor

CoreNVR 16. Network Video Recorder. Recording live monitoring and playback without additional PC. Control

Network Management Card. User Manual

Firewall VPN Router. Quick Installation Guide M73-APO09-380

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Innovative Electronics for a Changing World INDEX

801.11n Wireless Broadband Router

Gigabyte Content Management System Console User s Guide. Version: 0.1

BROADBAND INTERNET ROUTER USER S MANUAL. Version Page 1 of 13 -

How to Log On Main Screen Control Console Menus How to Log On Summary Page Navigation Menu... 29

USER S GUIDE Switched Rack PDU

CoreNVR 9. 9-Channel Network Video Recorder with HDMI. Recording live monitoring and playback without additional PC

Web. Anti- Spam. Disk. Mail DNS. Server. Backup

WiFi Edition

AP-GSS3000 TM 512Ch GSM SIM Server

AVTECH Software Inc.

Site Power Monitor Installation/Operation Manual Model: SPM-200

Quick Installation Guide For Sensors with Cacti

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

Poseidon MANUAL

Tk20 Network Infrastructure

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

4-CH Hybrid Digital Video Recorder

802.11n Wireless Broadband Router WNRT-625

Alarm Messages Clearing the Hardware Alarms How to Log On Summary Page Navigation Menu... 24

Meraki MX50 Hardware Installation Guide

NeoGate TA Series Quick Installation Guide

* Rev A* PN Rev A 1

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Internet Telephony PBX system IPX-1980

RC2000 Web Server User s Manual RCI P/N: FP-SER-ETH-SERVR1

Intelligent Power Distribution

Securely manage data center and network equipment from anywhere in the world.

Chapter 6 Using Network Monitoring Tools

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

SENSAPHONE 901 Tryens Road Aston, PA PH:

Advanced Business IP Phone IP652 Highlights:

Gigabit Multi-Homing VPN Security Router

Network Power Manager. User Manual

OUTDOOR IR NETWORK CAMERA Series

Hardening Guide. Installation Guide

User Manual. EtherUSB

Management, Logging and Troubleshooting

Cisco Small Business Managed Switches

SNMP Management of KIV-19s using the. TELEGRID KIV-19 Remote SNMP Proxy (KRSP TM )

Barracuda Link Balancer Administrator s Guide

Expert Power Control NET 4x 8212 / 8213

Turn on all of your network devices and then check to see if the LEDs on the Access Point display normally as the diagram below describes.

Online Help StruxureWare Data Center Expert

CenterMind G+ Smart and Proactive Environment Monitoring

ENC Enterprise Network Center. Intuitive, Real-time Monitoring and Management of Distributed Devices. Benefits. Access anytime, anywhere

Network Monitoring User Guide Pulse Appliance

EAP350. Long Range Ceiling Mount Access Point PRODUCT OVERVIEW

EAP300. Long Range Ceiling Mount Access Point PRODUCT OVERVIEW

Site Power Monitor Installation/Operation Manual Model: SPM-200

Chapter 6 Using Network Monitoring Tools

Quick Start Guide. RV0xx Series Routers

Transcription:

Technical Overview CM-16 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk

Need a lot of remote sensors in a rack mount? The CM-16 has web access, graphing, and alarm alerts sent by email, SNMP or (optional) SMS. Connect up to sixteen remote digital sensors, no splitters required. Supports three analogue sensors and has an internal temperature sensor. The CM-16 uses the same web engine as the CM-2 climate monitors. Accessible through a web browser Built-in temperature sensor 3 analogue inputs for 0-5VDC sensors 16 digital sensor ports Multi-level alarms with escalation Alarm notifications sent by email, SNMP or (optional) SMS With sixteen digital sensor ports, the CM-16 is ideal for applications that require a low-cost climate monitor and a large number of remote sensors.

OVERVIEW The Climate CM-16 is a 16 port hub, perfect for multi-cabinet monitoring applications and all within a 1U rack space. Providing Web-based remote surveillance with logging and graphing of connected sensors, it comes equipped with 16 digital sensor ports and 3 analogue sensor ports. Additional analogue sensors can be added with our CCAT analogue to digital converter. Add remote temperature, humidity and air flow sensors to the digital ports, whilst the three analogue ports can be used for door and water sensors, amongst others. Great value for money, the CM-16 and additional sensors are a cost-effective way of protecting a full row of IT hardware cabinets. It even comes with its own on-board website, giving you access to a detailed history of sensor readings and charts showing information that is appropriate to your rack room.

The UK s no.1 professional monitor EXPANDABILITY Temperature Up to 16 external sensors can also be added to provide monitoring of external conditions. Sensors available include: Temperature Sensor Light Sound Temperature, Humidity & Dew Point Sensor Airflow Point Water Sensor Smoke Sensor Humidity Current Transformer Camera Door Sensor SOFTWARE PROTOCOLS SUPPORTED The following software protocols are supported as standard: Power loss Water Web (HTTP) Console Software SMTP/POP SNMP (full MIB) Generic Monitor FTP (firmware upgrades) Graphing Port Switching XML Number of Ports Network Connection Power Input Digital Sensor Ports Analogue Data Ports

WEB INTERFACE The web management interface is the primary way to interact with the CM-16. This interface allows a user to remotely check the status of the environment, view graphs of logged data and see web cam images. Configuration and administration of the unit is done through the web interface where multiple thresholds and alarms can be set. The firmware running on the Climate CM-16 is updated through the web interface.

OTHER ACCESS METHODS Besides web access, there are a variety of methods that can also be used for obtaining sensor data from the unit. Meta-tagged data system info is available in XML. Logged data can be downloaded as a CSV file. The device also supports SNMP (v1,v2, v3). INSTALLATION No client software or other support software is needed. Installation is simple using an intuitive web interface. Use DHCP or assign a static IP address. All connections are made through the front panel. No client software or installation CD is required. The user connects an Ethernet cable, sets the IP address and begins using the unit.

SPECIFICATIONS On-board Sensors: Temperature: -30 to 85 C (-22 to 185 F), +/- 0.5 C Remote Sensor Support Digital Sensor: 16 ports (up to 180m total cable length) Analogue Sensor: 3 inputs (contact closure, 0-5 VDC) Physical: 19 L x 1.75 H x 3 W (rack mount, 1U space) Power: 6VDC (supplied wall transformer) Ethernet: 10 Mbps, RJ-45 receptacle Real Time Clock (RTC) with power backup Reset IP push-button: restores factory defaults Software Features HTTP / HTTPS: web access Alarms: high/low values, multiple thresholds per sensor ESMTP / POP3: email alerts, ESMTP / POP3 auth SNMP (v1, v2c, v3): Gets, Trap and Clear alerts, MIB XML: meta-tagged sensor values, alarms, config Syslog: send debug messages to Syslog server Access-control: 3 access levels (view, control, admin) Web Cams (optional): Up to four can be displayed Compatible with Aggregator Console V3 software

CLIMATE SALES Climate monitor products and supporting components are available directly via our website or you can contact us using the details below. The Original Climate Badger Banks Harpsden Henley-on-Thames Oxfordshire RG9 4HL tel: 01491 410913 web: www.theclimate.co.uk