ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG



Similar documents
Emerson Network Power Rack PDU Systems

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Distributing Power to Blade Servers

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

Power Commander Power Distribution Units from Wiremold/Legrand offer

Cabinets 101: Configuring A Network Or Server Cabinet

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview

QuickSpecs. HP 480/277 Volt Solutions. Overview

HP UPS R1500 Generation 3

QuickSpecs. HP Remote Monitored Power Distribution Units (mpdu) Overview

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Precisely distribute, monitor, analyze and manage power distribution in your facility to maximize processing capacity and promote power efficiency.

Rack Power Distribution. Worldwide

Bring power safely and conveniently to wherever

Eaton epdu Data Center Product Catalog

Rack Power Distribution

Server Technology Inc.

Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, REV A.6 DECEMBER 9,

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

DCF Optimized Rack System Selection Guide

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

How to Set Up Your NSM4000 Appliance

Efficiency and Other Benefits of 208 Volt Over 120 Volt Input for IT Equipment

Plug-In Outlet Center Units

R5000 Uninterruptible Power System (UPS) Overview

Installation. Basic Rack Power Distribution Unit for Blade Servers

R5000 Uninterruptible Power System (UPS) Overview

Alternating Phase Power Distribution at the Data Center Rack PDU

ED1259R5 Updated April 2011 For latest specs visit

HP R12000 and R18000 DirectFlow UPS User Guide

Remote Site Management Solutions

The Different Types of AC Power Connectors in North America

AC Power For Business-Critical Continuity. Liebert MPH. User Manual North American & European Applications

The Different Types of AC Power Connectors in North America

Rack Systems Solutions

PE8216/PE8324. Energy Intelligence Solutions

Intel Server System S7000FC4UR

Power Distribution Considerations for Data Center Racks

How To Install A Power Supply (Uplast) With A Battery Pack

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Rack Installation Instructions

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

Uninterruptible Power Supply

Three-Phase Electric Power Distribution for Computer Data Centers

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

Intersection Preassembled 19-inch Rack

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

APC Step-Down Transformer. User s Manual

Open Rack Hardware v1.0

PE6108/PE6208/PE8108/PE8208

The power module is Feature Number 8800-F2-901.

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Raritan LCD KVM Console (T1700/T1900)

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Model #: SMART2200CRMXL

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

High-Efficiency AC Power Distribution for Data Centers

BC Pro UPS System Standby UPS System

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Power Supply Guide Version 1.0 for D-Show

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Raritan LCD KVM Console (T1700/T1900)

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

APC 3Phase Power Distribution

TrueAlarm Fire Alarm Systems

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

DVI DA2 and DVI DA 4 User Guide

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

PX Intelligent Rack PDUs

Instruction Manual. 1T-VGA-412 and 1T-VGA-414 RGBHB/YPbPr Distribution Amplifier

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

HP NetServer LH 3000r Rack Cabling Reference Guide

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

16/32 Channel 1U Rack Mount CCTV Power Supply

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

MultiVOIP FX FXS-Only SIP Gateways

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

ASKING FOR ASSISTANCE

SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays

How To Power A Bladecenter H Servers

EKOS Cart. Instructions for Use

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

Rack Power Distribution Unit For Critical IT Equipment

Transcription:

ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG

Introduction The Zonit Data Center Power Distribution System (zpds ) offers an ultrareliable, turnkey power distribution system for modern high-availability missioncritical data centers. It simplifies the distribution, management and monitoring of power distribution between data center Power Distribution Units (PDUs) and enduser racks, cages and servers. It enables quick and easy deployment and redeployment of data center resources while eliminating the source of errors that result in downtime and unbalanced use of power phases. Through a system of customer rack-mounted power units, power strips, power adaptors, and reliable twist-lock connectors used for all main system connections, the vast majority of data center servers and rack configurations can be supported simply by selecting the power accessory appropriate for the equipment requirements. This catalog describes the components of the Zonit power distribution system, and gives numbers for ordering. Refer to the Zonit Power Distribution System Deployment Guide for the information needed to determine what components to order. Zonit System Catalog 2

THE ZONIT POWER SYSTEM Call your Zonit sales representative for pricing and delivery information. Sales and Technical assistance is available from Zonit at support@zonit.com, or by calling 720-266-0050. ZONIT BASE UNIT SUMMARY Agency Approval UL & c-ul Listed AC Voltage Input 208V WYE (3-Phase) AC Voltage Output 120V Current Input 30A Full Load W 21,600 W NEMA Outlets for Power Strips Four (4), L21-20R NEMA Convenience Outlets Six (6), 5-15/20 T-slot Rack Mount Options 19" and 23" Chassis Dimensions (2U) 3.33 H x 15.5 W x 13.963 D Rack Placement Options Front, Rear, Midpoint NEMA Plugs L21-30P (2 each) Cord Length 10' (2 each) (custom lengths available) Warranty 25 years ZONIT BASE UNIT ZPDU1 Zonit Power Distribution Unit ZPDU1 Zonit System Catalog 3

ZONIT POWER STRIP SUMMARY Vertical 120V Model Vertical 208V Model Agency Approval UL Listed UL Listed AC Voltage Input 208V (3-Phase) 208V (3-Phase) AC Voltage Output 120V Single Phase 208V Single Phase Current Input 20A 3-phase 20A 3-phase Full Load W 7200W 7200 W NEMA Receptacles Twenty (20), 5-15/20T Twenty (20), 6-15/20T Rack Mount Options Vertical Vertical Chassis Dimensions 66.25 L x 1.85 W x 1.3 D Same as 120V Rack Placement Options One each corner, 4 post racks, custom One each corner, 4 post racks, custom NEMA Plug L21-20P L21-20P Cord Length Standard 10', optional Standard 10', optional Warranty 25 years 25 years ZONIT POWER STRIPS Zonit 120V w/ 20 NEMA 5-15/20 T-slot receptacles Zonit 120V w/ 40 NEMA 5-15/20 T-slot receptacles Zonit 208V w/ 20 NEMA 6-15/20 T-slot receptacles VPS1-5T20 VPS1-5T40 VPS1-6T20 * Zonit Power Strips ship with a Universal 66 mounting bracket. Optional brackets are available. Zonit System Catalog 4

ZONIT MOUNTING BRACKETS Zonit Vertical Power Strip 4 Mounting Bracket Zonit Vertical Power Strip 7 Mounting Bracket Zonit Vertical Power Strip 2 Offset Mounting Bracket Zonit Vertical Power Strip 7 Offset Mounting Bracket VBKT1-4 VBKT1-7 VBKT1-OFF2 VBKT1-OFF7 VBKT1-4 VBKT1-7 VBKT1-OFF2 VBKT1-OFF7 Zonit System Catalog 5

ZONIT ADAPTOR SUMMARY Agency Approval NEC Compliant, Others Pending AC Voltage Input 208V WYE (3-Phase) (20A or 30A) AC Voltage Output As Specified Current Input 20 or 30A depending on model NEMA or MilSpec Plugs As specified Cord Length 1 foot standard, (custom lengths to 20 ) Warranty 25 years ZONIT PLUG ADAPTORS (1) Zonit L21-20P to (3) NEMA 5T-20R, 120V adaptor PA1-3x5T20-length (1) Zonit L21-20P to (3) IEC-C19-20R, 208V adaptor PA1-3xC19-length (1) Zonit L21-20P to (1) NEMA 6-20R, 208V adaptor PA1-620-length (1) Zonit L21-20P to (1) NEMA L5-20R, 120V adaptor PA1-L520-length (1) Zonit L21-30P to (1) NEMA L5-30R, 120V adaptor * PA1-L530-length (1) Zonit L21-20P to (1) NEMA L6-20R, 208V adaptor PA1-L620-length (1) Zonit L21-30P to (1) NEMA L6-30R, 208V adaptor * PA1-L630-length (1) Zonit L21-20P to (1) NEMA L14-20R, 120/208V adaptor PA1-L1420-length (1) Zonit L21-30P to (1) NEMA L14-30R, 120/208V adaptor * PA1-L1430-length (1) Zonit L21-20P to (1) NEMA L15-20R, 208V adaptor PA1-L1520-length (1) Zonit L21-30P to (1) NEMA L15-30R, 208V adaptor * PA1-L1530-length (1) Zonit L21-20P to (1) NEMA L21-20R, 120/208V adaptor PA1-L2120-length (1) Zonit L21-30P to (1) NEMA L21-30R, 120/208V adaptor * PA1-L2130-length * 30A adaptors connect directly to the Zonit uniform power whip grip Zonit adaptors are available to connect to most standard plug types, not all listed above. Adapters are available to supply equipment-specific plugs of any standard configuration with 20A from Zonit units in single phase or three-phase configurations, in either 120V or 208V. Contact your sales representative for details. Zonit System Catalog 6

Info@Zonit.Com 720-266-0050 www.zonit.com Copyright 2007-2010, Zonit Structured Solutions LLC, All rights reserved. Revision Date: September 2010