Y-200 Multi-Stage Sequencer



Similar documents
Commercial Boiler Systems and Controls

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

Variable Air Volume - VAV

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

CGC s Hybrid System Loop Control

R&D Electronics 8440 N. Waukegan Rd., Morton Grove, IL (847) Issue 12/08/06 om_207f.doc --

Model: DC-A2IO Advanced HVAC Controller

SECTION DETECTION AND ALARM

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Cast-Iron Performance Meeting today s commercial demands with effi ciency, strength and intelligent controls.

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Service Manual Models: 502, 752, 1002, 1302,

Contents. Introduction

Electronic Control Devices The European Product Catalogue 2007

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

TC 1818a. Operating Guide. Control Module SWM-015.5

INSTALLATION OPERATING & MAINTENANCE MANUAL

GaiaMoto Programmable Differential Temperature Controller

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

IntesisBox Modbus Server SAMSUNG Air Conditioners

Centro-Matic Automatic Lubrication Systems System Controls

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Controller Automation, Model II+

FX07 Field Controller

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Electronic Control Devices The European Product Catalogue 2007

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Integrated Building Management and Security System. Building Automation & Security.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

HCE80/HCC80/HCE80R/HCC80R

REMOTE CONTROL MANUAL

Ammonia Detection System Codes and Design Specifications

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Service Manual Models:

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

HVAC and Lighting Control Products for Open Building Automation Systems

HEAVY DUTY STORAGE GAS

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

APC APPLICATION NOTE #112

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Overview - Danfoss Link and living software versions

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Automatic Transfer Switch Controller

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS

PART 11: START-UP PROCEDURES FOR THE INSTALLER

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Commissioning - Construction Documents (Page 1 of 6)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Luna 3 Comfort Troubleshooting Guide June 2008

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Inwall Room Temperature Unit

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Better Boilers.

Service Manual Models:

TANKLESS DURABILITY Tankless Product Guide

TrueAlarm Fire Alarm Systems

Integrated Building Management and Security System. Building Automation & Security.

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

GSM HOME SECURITY SYSTEM

Dyeing Programmer DP - 01

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units

Mixing Valves. ARGUS Application Note: Mixing Valves

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Developer s Guide to Submetering Submetering Specifications for Multi-Housing Construction

Internet Office 500VA Tower Standby 120V UPS with USB port

T-100-R Installation Guide

Controller board and power supply for vivimat III systems

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

SMM. Installation Operation Maintenance

COMPTROL 5000 INDEX 52. Issue 5.99 AIR CONDITIONING MICROPROCESSOR OPERATING INSTRUCTIONS. STULZ GmbH, Hamburg

Hydro MPC Integrated Pump Systems and HVAC Applications GRUNDFOS HYDRO MPC

Natural geothermal energy.

HEAT HEAT COOL HEAT PUMP COOL

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

RESIDENTIAL THERMOSTATS CLIMATEMASTER

BC Pro UPS System Standby UPS System

Technical Support Bulletin Nr. 20 Special AC Functions

Contact ID Event Definition Codes

Transcription:

Y-200 Multi-Stage Sequencer Designed for use with single or multiple space heating or hot water supply systems, the Y-200 is offered in 4- and 8-stage configurations and is available loose or factory-mounted on Hi Delta or Raytherm boilers, and loose on MVB boilers. It is expandable up to 40 stages using an 8-stage master control with up to four 8-stage slave controls. It monitors and displays supply temperature on all applications including outdoor temperature when the appropriate reset mode is selected. In addition, Y-200 offers state-of-the-art PID logic and selectable lead-lag, manual override and outdoor reset. Options include a build-in modem, remote set point and LonWorks module that controls multiple boilers with one LonWorks control interface. Housed in a NEMA 3R enclosure, the Y-200 is suitable for outdoor installations. 4 or 8 boilers/stages, expandable to 40 Selectable P or PID logic LCD display NEMA 3R enclosure System water and outdoor air sensors 365-day time clock Auto/manual lead-lag and enable/disable functions Manual override Password protection 120 VAC, 60 Hz, 0.5A supply power requirement Relay Ratings - 10A @ 250 VAC Lockable enclosure UL and cul approved Options Remote setpoint (2-10 VDC or 4-20 ma) Modem Auxiliary contacts Alarm bell LonWorksT module ly multi-boiler sequencer LonMarkT certified for LonWorks protocol interoperability. Proper order for Standard Network Variable Types (SNVT_) tags ensures smooth implementation. No external gateway required. Adjustable outdoor reset ratio (0.01:1 to 20:1) Min. system water temperature (40 F) Max. system water temperature (235 F) Automatic/manual lead-lag (0 to 100 hrs.) Control band (0.5 to 10 F) Initial setpoint (40 to 235 F) Outdoor cutoff (32 to 200 F) Outdoor cutoff deadband (1 to 10 F) Morning boost Alternate setpoint Night setback Adjustable PID Boiler-on delay (0 to 5 min.) Stage-on delay (0 to 60 sec.) System pump-off delay (0 to 10 min.) Temperature measurement ( F or C) Ordering Information Y-241 Y-281 4-stages 8-stages

Electronic Temperature Controllers Engineered for Raypak W Boilers & Water Heaters Leading-Edge Controllers For over 60 years, Raypak s low-mass, high-recovery designs have set the standard for hot water space heating/supply boilers. To optimize performance and take full advantage of its boilers many benefits, Raypak developed its own specialized controllers whenever standard commercial versions were not adequate. In the 1950s, Raypak led the way in load-tracking modulation, utilizing the ModuSnap controller with its Raytherm boilers. In the early 1980s, Raypak introduced the B-6000, the first true electronic central boiler/bms system for modulating boilers. Today, Raypak s array of temperature controllers offers such state-of-the-art features as: sequence-control of up to 40 boilers; PID technology (see below); optimized approach to outdoor reset; LonWorks or Building Management System interfacing; modulation or stage-firing control; and other energy-saving functions. Unlike off-the-shelf controllers, Raypak s five controller models have been specially designed to maximize the performance of its leading-edge boiler systems. The Right Boiler for the Right Application RaythermT series Rugged, outdoor proven even in the toughest environments, offers exceptional value while being the simplest unit to commission and maintain. With its atmospheric-burner, horizontal water-tube design and standard Category I (B-vent) venting for indoor applications, installation is familiar and trouble free. Using PID Technology to Maximize Performance and Efficiency Hi DeltaT series Also with a horizontal water-tube design, the unit features 100% fan-assisted combustion in on-off or multistage configurations. With multiple venting options and efficiencies that range from 84% to 87%, Raypak has you covered. Full onboard diagnostics in real English. Low NOx compliant in all 50 states. MVBT series A vertical-tube boiler with a modulating (4:1), fanassisted burner offers the smallest (5.4 square feet) installed footprint of its kind and efficiencies of 84% (Cat I) or 87%(Cat IV). Full onboard diagnostics in real English, storing up to 16 reported faults. Low NOx compliant in all 50 states. Lowest required minimum inlet temp 120 F. Fits through a 30 door. XThermEand XFyreEseries XThermE vertical condensing boiler and XFyreE mod-con style boilers offer efficiencies up to 99% as well as PVC venting options. CSA outdoor and indoor rated. True modulation 4:1 XTherm and 5:1 XFyre. Low NOx compliant in all 50 states. XFyre has built-in cascade control for up to 8 units. Full onboard diagnostics in real English Controller Applications & Boiler Compatibility At-A-Glance: Applications Raypak controllers feature state-of-the-art PID technology, an application of Proportional, Integral and Derivative functions in varying algorithms to optimize system performance. Other controllers on the market either do not utilize PID technology or use only the Proportional (P) function (the component that controls output in proportion to how far the monitored point is from the target temperature). Raypak s controller series also makes use of the Integral (I) function which factors in the time it takes to reach the target temperature and enhances the proportional response accordingly. Add to this the Derivative (D) function which monitors how quickly the monitored point is approaching or drifting away from the target temperature. With all three functions, a properly designed PID-based control achieves set point quickly and levels off at the target temperature with minimal over- or under-shooting. The result is maximum system efficiency and performance. Boilers/Water Heaters Controller Space Heating Hot Water Supply MVB Hi Delta Raytherm XTherm TempTracker v v v v TempTracker Mod v v v v v TempTracker Mod+ Hybrid v v v v v v Y-200 v v v v v v RayTemp v v v v v

TempTracker Multi-Stage Controller TempTracker Mod Modulating Boiler Controller TempTracker stage-controllers are designed to sequence multiple boilers up to four total stages, whether it s one to four on/off boilers, two two-stage boilers, or one boiler with up to four stages. They are available factory-mounted or loose on Hi Delta boilers, and loose on Raytherm boilers. TempTracker Mod is a single-boiler modulating control that is integral to the MVB and XTherm, optional on Raytherm. Both controls can be used for space heating and hot water supply with eight application-specific modes to meet various applications, including outdoor reset for heating systems. The controls monitor and display inlet and outlet temperatures on all applications as well as monitor outdoor temperature when an outdoor reset mode is selected. TempTracker - 1-4 boilers/stages TempTracker Mod - 1 MVB (modulating) boiler, XTherm and Raytherm Selectable P or PID logic LCD display NEMA 1 enclosure Boiler inlet and outlet water sensors System water sensor Outdoor air sensor optional Alarm ready (pilot duty) CSA approved 24 VAC, 60 Hz, 3 VA supply power requirement Relay Ratings Stage 1: 5A @ 120 VAC Stages 2 to 4: 3A @ 120 VAC Limp-Along Feature- Ability to operate with as few as 1 of the 3 water sensors. Provides service indication when a sensor fails. BMS 0-10VDC setpoint control BMS 0-10VDC firing rate control Fully Adjustable Outdoor Reset Slope Raypak s custom software allows for complete adjustment of the outdoor reset slope start and end points. At right: TempTracker, Target Temperature View Pump 185 F Ending Water Temperature -10 F Air Temperature 105 F Starting Water Temperature 70 F Air Temperature Above: Temptracker Mod, % Output View % Output (Firing Rate) Burner Pump Burner Firing Stages 8 programming modes for TempTracker and TempTracker Mod Adjustable outdoor reset ratio Min. system water temperature (70 F) Max. system water temperature Heating: 220 F DHW: 190 F Temperature differential (2 to 42 F) Boiler target (70 to 220 F) Outdoor cutoff (35 to 85 F) Boiler mass (low, med, high) Stage-on delay (P mode) (10 sec. to 8 min.) System pump-off delay (0 to 20 min.) Stage Control only Temperature measurement ( F or C) Boiler pump off delay (0 to 20 min.) Mod Control Current Target Temperature Ordering Information (TempTracker) B-26 2-stage setpoint B-27 2-stage outdoor reset B-21 4-stage setpoint B-23 4-stage outdoor reset B-40 Raytherm Mod B-41 Raytherm Mod outdoor reset

TempTracker Mod+ Hybrid Multi-Boiler Modulating Controller The TempTracker MOD+ Hybrid is available as a loose option and controls up to four MVB, XTherm, XFyre and Raytherm boilers for precise load tracking of space heating and hot water supply systems. Expand the control to 16 boilers by adding up to two six-boiler expansion modules. TempTracker Mod+ monitors and displays supply water temperatures on all applications including outdoor temperature when outdoor reset mode is selected. As an added feature, this model offers PID logic as well as automatic or manually selectable lead-lag boiler operation. During boiler servicing or in the event of a controller problem, a manual override feature can be activated to bypass programmed operation. Outdoor Temperature System Temperature 1-4 boilers, expandable to 16 with optional expansion modules Selectable P or PID logic LCD display NEMA 1 enclosure System water and outdoor air sensors 365-day time clock Auto/manual lead-lag and enable/disable functions Manual override DHW override Lockable enclosure UL and cul approved 120 VAC, 60 Hz, 12 VA supply power requirement Relay ratings - 1A inductive; 6A @ 120 VAC 15A total for all circuits Remote Setpoint (4-20 ma) Raypak has highly customized the TempTracker Mod+Hybrid to maximize the overall system efficiency when used with our boilers and water heaters. Hybrid control function for multi boiler installations using condensing and non-condensing boilers. At right: TempTracker Mod+, Standard View Boiler Firing Rate Lead Boiler (Indicated by parenthesis) Selectable modulating outputs (4-20 ma, or 0-10 VDC) Adjustable outdoor reset ratio (1:4 to 4:1) Min. system water temperature (70 to 180 F) Max. system water temperature (90 to 240 F) Automatic/manual lead-lag (1 to 1440 hrs.) Initial setpoint (70 to 240 F) Outdoor cutoff (20 to 100 F) Morning boost (30 min.) Night setback (0 to 75 F) DHW override (with or without priority) System sensor gain (-5 to +5 F) Outdoor sensor offset adjustment (-5 to +5 F) Boiler gain (-10 to +10 F) Boiler-on delay (0 to 60 min) System pump-off delay (0 to 360 min) Standby boiler delay (1 to 60 min) Temperature measurement ( F or C) Hybrid system using 2-MVB s and 1-XTherm Ordering Information B-36 4 boilers B-37 10 boilers B-38 16 boilers B-39 Remote setpoint module

RayTempE Demand-Based DHW Controller RayTemp is a demand-based stage set point reset controller for use with single or multiple Raytherm, Hi Delta and MVB hot water supply heaters and is available factory-mounted and -wired in Hi Delta units or loose for remote-mounting in single or multiple Hi Delta, MVB or Raytherm systems. RayTemp adjusts water temperature based on system demand to minimize energy consumption during off-peak times. It monitors daily and weekly hot water usage, modifying supply water temperature based upon the most recent history. As a result, unnecessary standby losses, the biggest contributor to energy waste, are eliminated. RayTemp also provides data logging capability for viewing and the ability to download up to 12 months of performance history. Consult your local utility for possible rebates applicable to demand-based controllers, such as RayTemp. 2 or 4 heaters/stages PID logic LCD display NEMA 1 enclosure Tank and building return sensors Demand profile memory Data logging and downloads Password protection Lockable enclosure Supply power requirements Heater-mounted: 24 VAC, 50/60 Hz, 0.8 A Wall-mounted: 120 VAC, 50/60 Hz, 0.17 A Relay ratings - 1.5A @ 24 VAC All RayTemp models are eligible for the maximum California Energy Rebates. Up to 4 stages of control Lead/Lag Morning boost and night setback 7-day learning cycle Ordering Information B-24 B-25 2-stages 4-stages Options Modem for remote monitoring and fault notification 4-Stage model only (B-25) Raypak, Inc. 2151 Eastman Avenue Oxnard, CA 93030 (805) 278-5300 phone (805) 872-9725 fax www.raypak.com Cat. No. 5100.22D Effective 06-15-10 Replaces: 12-01-09