ELECTRODE BOILERS VAPOR POWER INTERNATIONAL



Similar documents
Originators of the Flexible Water Tube design

Energy Saving Solutions. Bob Montgomery Technical Solutions Specialist Waterloo Manufacturing

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Commercial Boiler Systems and Controls

I. STEAM GENERATION, BOILER TYPES

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Some Criteria for Choosing a Steam Boiler for a Microbrewery

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

SIOUX HYBRID WATER HEATER

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

Routine and Emergency Boiler Operation

Guidelines for Preparing for a Temporary Steam Plant

FLASH TANK ECONOMIZER PRODUCT GUIDE

ASME Packaged Indirect Fired Water Heater

A Primer on Protecting Idle Boilers By Howard Benisvy, Member ASHRAE

Boiler Preparation, Start-Up and Shutdown

steam centre of excellence Steam Boiler System Optimization

Steam System Efficiency. Bill Lumsden Leidos Engineering

The soot and scale problems

HC900 for Boiler Control Applications

BOILER FEED AND CONDENSATE RECOVERY SYSTEMS Extend the life and efficiency of your boiler system

Chicago Stationary Engineer Licensure Examination Information

Rules for construction of heating boilers, Boiler and Pressure Vessel Code, Section IV-2007

Recover Heat from Boiler Blowdown Water

Energy Efficiency in Steam Systems

Energy Efficient Operations and Maintenance Strategies for Boilers

IVISIONS STEAM PLANT DIVISIONS TOTAL TURNKEY SOLUTIONS. INDUSTRIAL BOILER & MECHANICAL

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Commercial Semi-Instantaneous Water Heaters

Description of Thermal Oxidizers

Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng

Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Presentation Outline. Background

1 DESCRIPTION OF THE APPLIANCE

GUIDELINES FOR LOGBOOKS COMPLIANCE TO BOILER REGULATIONS N.J.A.C. 12:90

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

University of Iowa Power Plant

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23

Boiler Efficiency. Charles Stark Department of Poultry Science.

INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Boiler NOx Emissions and Energy Efficiency

Boiler and Burner Cleaning and Servicing Specifications

Energy Saving Fact Sheet Boilers

Commercial Gas Water Heaters

Why use Tigerloop in fuel heating systems?

CEILING CASSETTE FAN COIL UNIT

MOSS WOOD BOILER SYSTEMS

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Fossil fuel heating equipment

IGEMA BOILER LEVEL & TDS CONTROLS

Tips for burner modulation, air/fuel cross-limiting, excess-air regulation, oxygen trim and total heat control

FLUID CIRCULATION PUMP PRESSURE

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

Integrated Solar Radiant Systems

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

This will also provide you with the knowledge to insure long life for your Investment

OPTIONS. for. Replacing Boiler Plant. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

HC900 Boiler Control. Background. Solution. Application Brief Industry: Manufacturing

MC (Multi-Circulation) f o r S A G D a n d I n d u s t r i a l A p p l i c a t i o n s

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Glossary of Heating, Ventilation and Air Conditioning Terms

Investigating the Impact of Boiler Aging In Replacement Decisions

HUMIDIFICATION DESIGN CHECKLIST: GETTING IT RIGHT THE FIRST TIME.

Factory owners must ensure the boiler is:

RESIDUAL FUEL OIL AS A SU.PPLEMENTARY FUEL

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Action Plan Template HVAC Page 1

Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

How To Clean Up A Reactor Water Cleanup

Commercial Gas Water Heater

BOILER ROOM GUIDE. Reference Guide

Committed to make a better world

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

Oil and Coolant Circulating Heating System. Model - OCSM

Natural Gas Conversions of Existing Coal-Fired Boilers

Screw Plug Immersion Heaters

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Safe management of industrial steam and hot water boilers A guide for owners, managers and supervisors of boilers, boiler houses and boiler plant

Commercial Gas Furnace Upflow

Model CFC ClearFire Condensing Boiler

Condensing Boiler Efficiency

Engineered Solutions

G234X-55 Conventional Gas Boiler

TECHNICAL ADVISORY BULLETIN

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

Department of Veterans Affairs VHA DIRECTIVE Veterans Health Administration Washington, DC October 15, 2008 BOILER PLANT OPERATIONS

OROT RABIN POWER STATION UNITS x 350 MW

Boiler & Pressure Vessel Inspection discrepancies and failures

GAS HEATING IN COMMERCIAL PREMISES

Transcription:

ELECTRODE BOILERS WITH JET-FLO Technology VAPOR POWER INTERNATIONAL

ELECTRODE boilers The Electrode Steam Boiler with Jet-Flo technology consists of an insulated pressure vessel and is fully enclosed in 18 gauge enameled steel panels. There is no heat transfer through tube walls and there will never be tube failures from excessive wall temperature, poor water treatment, or fireside corrosion, since there are no tubes to fail! Heat transfer takes place directly in the water in the steam chamber, thus producing high quality steam of 99.95% purity throughout the operating range. Electrode Steam Boilers Steam from: 3000 kw to 34,000 kw (10,000 to 113,000 PPH) Pressure from: 100 500 PSIG Voltages from: 4160 14,400 Volts Hot Water Boilers with similar capacities are also available ADVANTAGES High efficiency Greater than 99% High turndown & QUICK RESPONSE TO LOAD CHANGES Safely operate as low as 1% of output Reliable source of steam For areas affected by oil and/or gas shortages, or where coal is either low grade or not available No moving parts Eliminates downtime due to packing leaks around the hydraulically-operated shield positioning system that is present on other designs. No risk of failure of internal mechanical shields. No hydraulic system required. LOW INSTALLATION COST Eliminates need for special boiler room, fuel handling and storage equipment, air handling equipment, preheaters and/or economizers, stacks, flues and emission control equipment, ash handling and disposal facilities, combustion safety systems, noise abatement equipment, plus space and installation costs associated with aforementioned equipment. No Emissions Makes for an easy installation because no air permits are required A Vapor Power electrode steam boiler offers a great hybrid boiler room solution, taking advantage of off peak power rates. Fossil fuel fired boilers and the electrode boiler are automatically rotated based on real time power costs, maximizing steam plant efficiency. Electrode steam boilers are available in sizes from 3,000 to 34,000KW, 10,000 to 113,000 PPH, supply voltage of 4,160 to 14,400 volts, and offer efficiencies greater than 99%. LABOR SAVINGS Electric boilers in most states are classified as unfired steam generators and as such do not require full operator attendance No dielectric barriers needed No special water treatment Industrial Grade components Applications Brewery & Distillation Container & Paper Processing Healthcare Facilities Power Plant Process Steam & Heat University & Institutional Facilities 2 3

electrode boilers Controls The Vapor Power electrode boiler creates operating advantages from its unique design which results in a high efficiency, high quality steam boiler. Using electricity as a clean, efficient and easily controlled fuel, all the energy input to the boiler is converted to steam with 99% efficiency. Vapor Power s electrode boiler output is controllable from 0-100%, with neither the limited turndown ratios nor the increasing inefficiency at low output conditions characteristic of fossil-fired boilers. There are no stacks to purchase and there are zero pollutant emissions. AVAILABLE POWER: With the electric boiler set at a slightly higher pressure than parallel fossil fueled boilers, sensing plant demand, and limited to a maximum plant demand set point, competitively priced available power can be consumed to effect a flat demand curve. The electrode boiler is locally managed by a PLCbased system that controls every aspect of the boiler which includes control of water level, steam pressure and KW limit. All safety devices will also be monitored by the PLC. Interface to the PLC by an operator is accomplished through an HMI device that communicates directly with the boiler PLC. Remote data acquisition and control is available via ModBus, Ethernet, Bacnet, or other communication protocol. Built to Meet Standards The simplicity of electrode controls and engineered boiler design results in significantly reduced maintenance. With no moving parts within the boiler, there is less maintenance associated with our units. Even under the conditions of feedwater loss, for example, the electrode boiler is fail-safe as low water in itself affects boiler shutdown, precluding catastrophic failure. There is no heat transfer through tube walls and there will never be tube failures from excessive wall temperature, poor water treatment, or fireside corrosion, since there are no tubes to fail. Heat transfer takes place directly in the water in the steam chamber, thus producing high quality steam of 99.95% purity throughout the operating range. By using a 2-element control system, the electric boiler would either generate as much steam as allowed by the demand control system or, when steam demand is below what the electric boiler is allowed to generate, be limited by the steam pressure control to a preset steam pressure. Using electricity as a clean, efficient and easily controlled fuel, all the energy input to the boiler is converted to steam with 99% efficiency Every unit is built to ASME Standards, Hartford inspected and National Board registered. Other approvals are also available upon request. Hot Water Option To generate hot water, Vapor Power offers a steam-to-water heat exchanger attached directly to the boiler. Outputs available range up to 170,000 MBTU/Hr. The advantage of this system is that the condensate from the heat exchanger flows by gravity back to the boiler eliminating the need for a condensate return or deaerator system, which also improves the system efficiency. 4 5

INTERNAL EXTERNAL PUMP PUMP BOILERS internal PUMP BOILERS 1. Circulation Pump 2. Pump Motor w/ VFD 3. Water Column 4. Standby Heater 5. Steam Outlet 6. Manhole 7. Safety Valves (2) 8. Conductivity Cell 9. Sight Gauge 10. Pressure Controls & Gauge 11. I/O Junction Box 12. High Voltage Entrance 13. Header Removal Clearance 14 Manway 1. Blowdown Valves 2. Pump Removal Clearance 3. Circulation Pump w/ VFD 4. Check Valve (for 2-pump boilers only) 4. Conductivity Cell 6. Sheet Metal Lagging 7. Insulation 8. Safety Valves (2) 9. Electrode Terminal Enclosure 10. Conduit Entrance Panel 11. Header Removal Clearance 12. Conductor Rod 13. High Voltage Insulators 14. Back Pressure Regulator 15. Steam Outlet 16. Non-Return Valve 17. Insulator Shields 18. Electrode / Strike Plate 19. Nozzle Header 20. Counter Electrode 21 Pressure Manifold & Pressure Gauge 22. Water Column & Sight Gauge 23. Surface Blowoff 24. Standby Heater 25. Feedwater Regulator 26. Manhole 27. Top Cover PARTIAL TOP VIEW Model Number Nominal Rating*** (KW) Nominal Rating*** (PPH) Dimensions (inches) Weight (Lbs)**** Number of @ 13.2KV 4160V 6.9KV 13.2KV 4160V 6.9KV 13.2KV Electrodes Dia H H1 H2 Ship Operate Flooded BBJ-300 800 1700 3000 2700 5700 10000 3 60 152 6 30 8500 1300 19700 Model Number Nominal Rating** (KW) Nominal Rating** (PPH) Dimensions (inches) Weight (Lbs)*** Number of @ 13.2KV 4160V 6.9KV 13.2KV 4160V 6.9KV 13.2KV Electrodes Dia H H1 H2 Ship Operate Flooded BBJ-450 1300 2500 4500 4300 8300 15000 3 60 172 16 30 9700 13000 22400 BBJ-600L** 1700 3400 6000 5700 11300 20000 3 60 168 24 66 10300 13600 23400 BBJ-600 1700 3400 6000 5700 11300 20000 3 60 186 24 30 10800 14300 24100 BBJ-750L** 2100 4200 7500 7000 14000 25000 3 60 186 32 84 11300 14800 25500 BBJ-750 2100 4200 7500 7000 14000 25000 3 60 200 32 36 11700 15400 26100 BBJ-840L** 2400 4700 8400 8000 15700 28000 3 60 194 38 84 11900 15800 27300 BBJ-840 2400 4700 8400 8000 15700 28000 3 60 210 38 36 12400 16500 28000 BBJ-1050L** 3000 5900 10500 10000 19600 35000 6 66 180 20 84 12300 15800 28100 BBJ-1050 3000 5900 10500 10000 19600 35000 6 66 196 20 36 12700 18200 30600 BBJ-1200L** 3400 6700 12000 11300 22300 40000 6 66 186 24 84 12700 16600 28900 * All of these models utilize external ANSI stardard circulation pumps ** Low headroom application, at a premium price - two circ. pumps provided side by side *** Ratings are for operation at 150 psi with 220 Degrees Farenheight Feedwater **** Weights are for 175psi design pressure BBJ-1200 3400 6700 12000 11300 22300 40000 6 72 218 194 24 15500 21400 34600 BBJ-1500 4200 8500 15000 14000 28300 50000 6 72 232 208 32 16500 23800 36700 BBJ-1650 4700 9200 16500 15700 30600 55000 6 72 242 218 38 17500 25400 39500 BBJ-1800 5100 10100 18000 17000 33600 60000 9 84 237 210 21 20000 32000 50000 BBJ-2150 6100 12000 24500 20300 40000 72000 9 84 253 226 29 21000 34000 54000 BBJ-2550* 7200 14300 25000 24000 47600 85000 9 84 245 218 35 23000 33000 53000 BBJ-2400* 6800 13400 24000 22600 44600 80000 12 96 236 206 18 24500 40000 67000 BBJ-3000* 8500 16800 30000 28300 55900 100000 12 96 252 222 26 26500 43500 72000 BBJ-3400* 9600 19000 34000 32000 63300 113000 12 102 264 234 32 30000 51500 85000 * These models utilize 2 internal pumps ** Ratings are for operation at 150 psi with 220 Degrees Farenheight Feedwater *** Weights are for 175psi design pressure 6 7

VAPOR POWER INTERNATIONAL 551 S. County Line Rd. Franklin Park, IL 60131 P: 630.694.5500 F: 630.694.2230 VaporPower.com