Specification. Indoor Air Quality Management



Similar documents
IEQ Management Plan. Denver Museum of Nature and Science ECF Addition

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

Toward Better Buildings. Resources for Managing IAQ during Construction

Radford University. Indoor Air Quality Management Plan

WATER DAMAGE INVESTIGATION. Massachusetts Gaming Commission 101 Federal Street Boston, Massachusetts

WATER DAMAGE INVESTIGATION. Massachusetts Department of Public Utilities 1 South Station Boston, Massachusetts

LEED PRESENTATION OUTLINE

FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING

KEY ELEMENTS IN PREVENTING AND MITIGATING MOLD CLAIMS

CONSTRUCTION IAQ MANAGEMENT PLAN During Construction

NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS

Mold Response and Remediation Plan

MOLD RESPONSE AND REMEDIATION PLAN

ASBESTOS MANAGEMENT PROGRAM

The Finnish Classification of Indoor Environment and Material Emissions

NORMI Professional Guidance for DIY Projects

Mold Management Plan Operations & Maintenance

INDOOR AIR QUALITY POST-OCCUPANCY ASSESSMENT. Massachusetts Department of Revenue 100 TradeCenter, Suite 760 Woburn, MA

SECTION HVAC AIR-DISTRIBUTION SYSTEM CLEANING

DuPont Surfaces. Suitable for both horizontal and vertical applications, Corian solid surfaces and Zodiaq

Innovation #9/12. of all Formaldehyde for up to

ASBESTOS SCIENCE TECHNOLOGIES, INC.

INDOOR AIR QUALITY ASSESSMENT MOLD INVESTIGATION. Department Of Children and Family 810 Memorial Drive Cambridge, Massachusetts

APPENDIX B. EPA s Investigating, Evaluating, and Remediating Moisture and Mold Problems (see EPA website for complete details)

Building and Grounds Maintenance Checklist

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

How To Prevent And Manage A Flood And Mold

Mold and Mildew Mold and mildew can be detected by sight, smell and touch.

Indoor Air Quality Issues for Hotels

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

Public Employees Occupational Safety and Health Program

Staff shall ensure that airflow is not obstructed by the blocking of ventilators with posters, furniture, books, or other obstacles.

School Renovation and Construction: What you Need to Know to Protect Child and Adult Environmental Health

INDOOR AIR QUALITY REASSESSMENT. Sgt. William H. Carney Memorial Academy 247 Elm Street New Bedford, Massachusetts

Controlling Condensation On CWP Insulation BY ED LIGHT, MEMBER ASHRAE; JAMES BAILEY, P.E., MEMBER ASHRAE; AND ROGER GAY

MOLD REMEDIATION KEY STEPS

1. Certification: Employ an ASCS certified by NADCA on a full-time basis. 2. Supervisor Qualifications: Certified as an ASCS by NADCA.

INDOOR AIR QUALITY INTRODUCTION WHAT ARE THE SYMPTOMS OF SICK BUILDING SYNDROME? WHEN DID POOR INDOOR AIR QUALITY BECOME A PROBLEM?

MOLD REMEDIATION PROCEDURES

March Get The Mold Out: Mold Clean-Up Guidance for Residences. Introduction

Old Dominion University Mold Management Plan

Guidelines for Mold Remediation (Removal)

FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING

Restoring your Property: How to be prepared for Rapid Response to Flood Damage

IEQ-15 Air Distribution System

ASBESTOS MANAGEMENT PROGRAM

DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program

THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM

North Carolina State University. Asbestos Management Plan

Material Safety Data Sheet

Lead Exposure Management Plan

Fans That Sense & Extract Volatile Organic Compounds and Humidity

University of Vermont

MOLD ASSESSMENT. Charles A. Bernazzani Elementary School 701 Furnace Brook Parkway Quincy, Massachusetts

Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project

Risk Bulletin. Mold Prevention and Control for Mechanical and HVAC Contractors. XL Group Insurance

Fungal Assessment. Smith Recreation Community Centre 1019 Hwy 2A, Smith, Alberta

34% 81% 84% 19% GOLD PROJECT HIGHLIGHTS. LEED Facts. Stubbs Laboratory

Get The Mold Out: Mold Clean-Up Guidance for Residences. Introduction

POMONA COLLEGE Sustainability Integration Office Facilities and Campus Services

MOISTURE MANAGEMENT DURING THE CONSTRUCTION PROCESS

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

Mold Basics. Why is mold growing in my home?

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Guide to the (Non-Residential) California Green Building Standards Code. Including changes effective July 1, 2012

STANDARD OPERATING PROCEDURES FOR MOLD REMEDIATION

Mould Mould A Basic Guide

University of Nevada, Reno Facilities Services Department STANDARD OPERATING PROCEDURE. Facilities Maintenance Services

SMACNA s IAQ for Occupied Buildings Under Construction

Mold. Guidelines for New Jersey Residents. Understanding Mold Investigations & Remediation

CENTER FOR ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program

Asbestos Inspection Project Procedure

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

INDOOR AIR QUALITY ASSESSMENT. Dennett Elementary School 80 Crescent Street Plympton, Massachusetts

Exposure and Control of Ten High Priority MSHA Contaminants in Metal Mines. Presented by: Shannon E. Newton, MPH, CIH

Water should be removed as soon as possible once the safety of the structure has been verified.

BUREAU OF ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

Indoor Air Quality- What You Need to Know

Now that Your Building Experienced Water Damage What Must You and Your Water Damage Restoration Contractor Agree On?

How To Test For Residual Dust

Indoor Environmental Quality Management Plan

Why is my air conditioner dripping on my customers?

Carson Dorn, Inc. December 18, Patrick Holmes Associate Manager Juneau I, LLC 645 G Street, Suite Anchorage, AK Dear Mr.

Draft Healthy Home Environmental Assessment Principles

ASBESTOS IN ROOFING SYSTEMS WORK PRACTICES AND DISPOSAL IN ASSOCIATION WITH ROOFING PROJECTS

PEOSH. Indoor Air Quality Training for Asthma-Friendly Schools Part I PEOSH Indoor Air Quality Standard Overview. Eric Weren, MSIH

Transcription:

GREENGUARD Environmental Institute 2211 Newmarket Parkway, Suite 110 Marietta, GA 30067 1.800.427.9681 Specification Indoor Air Quality Management This Master Specification section is intended for use in preparation of a project specification covering indoor air quality requirements. The specification includes the requirements of LEED-NC, LEED-EB and includes specifications for construction products, construction site management, construction sequencing, HVAC operation during construction, product installation, building flush-out and IAQ testing. Indoor Air Quality Management 01 3546-1 GREENGUARD Environmental Institute

SECTION 01 3546 INDOOR AIR QUALITY MANAGEMENT This section includes editing notes to assist the user in editing the section to suit project requirements. These notes are included as hidden text, and can be revealed or hidden by one of the following methods: Microsoft Word: From the pull-down menus select TOOLS, then OPTIONS. Under the tab labeled VIEW, select or deselect the HIDDEN TEXT option. Corel WordPerfect: From the pull-down menus select VIEW, then select or deselect the HIDDEN TEXT option. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Product requirements for indoor construction and finishing materials. 2. Final Construction Products List. 3. Construction site management. 4. Indoor Environmental Consultant qualifications. 5. Scheduling and product installation sequencing. 6. Operation of HVAC systems during construction. 7. Product installation. 8. Building flush out. 9. Indoor air quality testing. 10. Documentation and reporting. 1.2 REFERENCES A. American Conference of Government Industrial Hygienists (ACGIH). B. American National Standards Institute/American Society of Heating, Refrigeration, and Air- Conditioning Engineers (ANSI/ASHRAE): 1. 52.2 Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size. 2. 55 Thermal Environmental Conditions for Human Occupancy. 3. 62.1 Ventilation for Acceptable Indoor Air Quality. 4. 62.2 Ventilation and Acceptable Indoor Air Quality for Low-Rise Residential Buildings. Indoor Air Quality Management 01 3546-2 GREENGUARD Environmental Institute

C. GREENGUARD Environmental Institute (GREENGUARD) - Indoor Air Quality Certification Program. D. U.S. Green Building Council (USGBC) - Leadership in Energy and Environmental Design (LEED) 2009 for New Construction and Major Renovations. D. U.S. Green Building Council (USGBC) - Leadership in Energy and Environmental Design (LEED) 2009 for Commercial Interiors. E. Sheet Metal and Air Conditioning Manufacturer s Association International (SMACNA) F. United States Environmental Protection Agency (EPA): 1. Compendium of Methods for the Determination of Air Pollutants in Indoor Air. 2. National Ambient Air Quality Standard, Code of Federal Regulations, Title 40, Part 50. 1.3 DEFINITIONS A. Dry Products: Products used in a solid state, including gypsum board, carpet, acoustical panels and tiles, and textiles. B. MERV: Minimum Efficiency Reporting Value. C. Priority Products: Products known to be high chemical emitters, long term emitters, and those expected to present emissions in high amounts (high surface area). D. Threshold Limit Value (TLV): Industrial Work Place Standard as defined by ACGIH. E. Wet Products: Products used in a liquid or semi-liquid state, including adhesives, joint sealers, paints, and coatings. 1.4 SUBMITTALS A. Final Construction Products List: 1. Submit list of proposed indoor construction and finishing products. 2. Include strategies for minimizing use of wet products. 3. Obtain approval by [Architect] [Interior Designer] [Commissioning Agent] [ ] prior to installation of products. B. Indoor Air Quality Test Report: 1. Provide copies of Indoor Air Quality Test Report from Indoor Environmental Consultant. 2. Include in report: a. Study design including methodology for determination of air sampling locations and duration of sampling. b. Summary of sampling and analytical methods employed. c. Copy of field sampling logs. Indoor Air Quality Management 01 3546-3 GREENGUARD Environmental Institute

1.5 QUALITY ASSURANCE d. Summary of methods and results used to determine that ventilation system was started at normal daily start time and operated at minimum outside airflow rates for occupied mode for duration of air testing. e. Laboratory analytical data for each contaminant and summary table showing compliance with specified criteria. A. Provide written notification of product requirements to subcontractors and suppliers of interior construction and finishing products. B. Indoor Environmental Consultant Qualifications: 1. [Owner will] [Contractor shall] employ and pay for an Indoor Environmental Consultant to perform specified indoor air quality testing. 2. Minimum 5 years experience in conducting indoor environmental quality evaluations of non-industrial buildings. 3. Retain Certified Industrial Hygienist (CIH) on staff to review and sign test reports. 1.6 DELIVERY, STORAGE AND HANDLING A. Storage Area: 1. Designate secure storage area to facilitate protection of stored absorptive products. 2. Clearly identify storage area. Keep dry, clean, and orderly; prevent contamination of products. 3. Monitor storage areas for contamination; correct problems and implement preventative measures. B. Products: 1. Protect absorptive products from moisture damage before, during, and after installation. 2. Immediately remove products exhibiting stains, mold, mildew, or other evidence of water or moisture damage from site. PART 2 - PRODUCTS 2.1 GENERAL A. Interior Construction and Finishing Products; in purchasing products, give preference to: 1. Products designed and manufactured in manner to produce least harmful and irritating effects. 2. Products certified by GREENGUARD Environmental Institute as Low Emitting. For products that are not GREENGUARD Certified, provide a test, which at maximum is performed one year prior to installation, to ensure conformance to GREENGUARD standard emission values. 3. Products providing lowest practical yet technologically achievable emissions of particulates and chemical vapors, as defined in following paragraphs. B. Maximum Chemical emission Values for Products In Commercial or Retail Buildings: Indoor Air Quality Management 01 3546-4 GREENGUARD Environmental Institute

1. Emission rate calculations: Assume 32 cubic meters as volume for determination of product loading. 2. Product emission rates and modeling for predicted exposure concentrations: As measured in milligrams/square meter per hour (mg/m 2 hr) at anticipated loading (square meter/cubic meter [m 2 /m 3 ] within building. Predicted indoor concentrations shall be based on building modeling parameters of 0.72 air changes per hour (ACH). The product shall produce indoor air concentration levels less than the amounts specified for each substance within seven (7) days of installation. 3. Total VOC emission rate: Maximum total volatile organic compounds (VOC) of 0.05 milligrams/cubic meter (mg/m 3 ). 4. Total aldehydes: Maximum 0.1 parts per million (ppm). 5. Formaldehyde: Maximum 0.05 parts per million (ppm). 6. 4-Phenylcyclohexene (4-PC): Maximum 0.0065 milligrams/cubic meter (mg/m 3 ) or 0.1 parts per billion (ppb). 7. Styrene: Maximum 0.07 milligrams/cubic meter (mg/m 3 ). 8. For individual Volatile Organic Compounds (VOCs) not listed above: Shall produce an air concentration level less than 1/10th of the Threshold Limit Value (TLV) at the anticipated product loading in the building within seven (7) days of installation. 9. Regulated pollutants: Maximum air concentration as promulgated by National Ambient Air Quality Standard for primary and secondary outdoor air pollutants. 10. Identified carcinogens and reproductive toxins: Below levels of no significant risk according to evaluation protocols established by EPA or approved State and public health organizations. B. Maximum Chemical and Particle emission Values for Products In Educational, Daycare, Healthcare, or Otherwise Sensitive Environments: 11. Emission rate calculations: Assume 231 cubic meters as volume for determination of product loading. 12. Product emission rates and modeling for predicted exposure concentrations: As measured in milligrams/square meter per hour (mg/m 2 hr) at anticipated loading (square meter/cubic meter [m 2 /m 3 ] within building. Predicted indoor concentrations shall be based on building modeling parameters of 0.9 air changes per hour (ACH) and a 0.9 ventilated volume fraction. The product shall produce indoor air concentration levels less than the amounts specified for each substance within seven (7) days of installation except for formaldehyde. Formaldehyde criteria are established so that emission levels reach 0.014 ppm (13.5 ppb) within 14 days of installation (meeting CA 1350 requirements). 13. Total VOC emission rate: Maximum total volatile organic compounds (VOC) of 0.022 milligrams/cubic meter (mg/m 3 ). 14. Total aldehydes: Maximum 0.043 parts per million (ppm). 15. Formaldehyde: Maximum 0.0135 parts per million (ppm) within 14 days of installation. 16. Total Phthalates: Maximum 0.01 milligrams/cubic meter (mg/m 3 ). Total phthalates are defined as the total response of a specific target list of phthalates including dibutyl (DBP), diethylhexyl (DEHD), diethyl (DEP), butylbenzyl(bbp), di-octyl (DOP), and dimethyl (DMP) phthalates (conducted using a modified phthalate specific analytical method, OSHA 104). 17. Total Particles: Maximum 0.02 milligrams/cubic meter (mg/m 3 ). This is applicable only to fibrous, particle-releasing products with exposed surface area in air streams (determined using a forced air test with specific test method). 18. For individual Volatile Organic Compounds (VOCs) not listed above: Shall produce an air concentration level less than 1/100 of the Threshold Limit Value (TLV) and less than ½ of the California Chronic REL at the anticipated product loading in the building within seven (7) days of installation. Indoor Air Quality Management 01 3546-5 GREENGUARD Environmental Institute

PART 3 - EXECUTION 3.1 CONSTRUCTION SITE MANAGEMENT A. If weather or plumbing leaks result in interior of building becoming wet: 1. Ensure that building is properly dried out prior to installation of any additional materials into the space. 2. Inspect installed materials for mold and mildew. 3. Affected materials less than 10 square feet in area: Remediate materials according to accepted industry practices. 4. Affected materials 10 square feet or more in area: Employ certified remediation firm to remove materials from site. B. For projects incorporating new construction in an existing space, follow the procedures outlined in the Sheet Metal and Air Conditioning National Contractors Association (SMACNA) IAQ Guidelines for Occupied Buildings Under Construction, Chapter 3, also see section 3.3 below. 3.2 SCHEDULING AND PRODUCT INSTALLATION SEQUENCING A. Schedule shipment and delivery of products based on actual construction progress to minimize time products are stored on site. B. Prepare and staff building site for delivery of products. C. Inspect products upon delivery for conformance to Final Construction Materials List and to ensure that they are free from water and moisture damage and properly stored. D. Use the least practical amount of wet materials. E. Do not install dry materials until wet materials have been installed and allowed to dry to greatest extent practical. F. Choose drying times so that specified pollutant emission rates are achieved prior to installation of dry materials. G. Install solvent containing materials during periods during which building is unoccupied. Schedule installation as early as possible during construction to allow for maximum offgassing prior to building occupancy or re-occupancy. H. Install high-voc emitting products prior to installation of porous and fibrous products, or protect with polyethylene sheeting, properly sealed. I. Complete installation of interior finishing materials two to four weeks prior to building occupancy. Continuously flush out building with fresh air for two to four weeks. J. Provide temporary ventilation during touch-up operations; extend building flush-out for minimum of four days after touch-up is complete. 3.3 OPERATION OF HVAC SYSTEMS DURING CONSTRUCTION IN OCCUPIED BUILDINGS A. Depressurize construction area at rate at least 10 percent greater than rate of supply or pressurize existing spaces, whichever is more feasible. B. Erect supplemental containment barriers if pressurization is not adequate to control construction dust and odors in occupied areas. Indoor Air Quality Management 01 3546-6 GREENGUARD Environmental Institute

C. Ensure that construction equipment and staging areas are away from air intakes for existing construction. D. Temporarily seal intake dampers for existing space when high-emitting construction activities are performed near outdoor air intakes for existing construction. E. During demolition or construction in existing spaces: 1. Do not operate building HVAC systems in affected areas. 2. Temporarily seal supply and return openings with plastic sheeting. 3. If system must be operational during demolition or construction, install temporary MERV 8 filters in return openings in accordance with LEED Guidelines; maintain in clean condition. 3.4 BUILDING FLUSH-OUT A. If building meets Clearance Criteria immediately following construction, building flush-out is not required. B. Following completion of interior finishes and installation of new furnishings, flush building with 100 percent clean outdoor air for two to four weeks prior to occupancy. If time does not permit a two to four week flush-out period, the design and construction team shall designate whatever time is available for building flush (even if it is as minimal as 24 hours). C. Install new MERV 13 filtration media prior to beginning the flush-out procedure. D. After flush-out, install new MERV 13 filtration media, except for those filters processing only outdoor air. 3.5 INDOOR AIR QUALITY TESTING A. Perform testing after completion of construction and installation of new furnishings, but before Owner occupancy, using protocols established by reputable standard setting or method development organizations such as state and federal agencies and reputable nongovernmental organizations such as the GREENGUARD Environmental Institute or ASTM. B. Conduct testing prior to Owner occupancy but during normally occupied hours. C. Operate building HVAC system at normal daily start and stop times at minimum outside airflow for occupied mode for duration of testing. D. Number of Air Sampling Locations: Minimum of one per 25,000 square feet or for each contiguous floor area, whichever is greater. Include areas with least ventilation and greatest presumed source strength. E. At each location, collect samples at to 6 feet above floor over minimum 4 hour period. F. Demonstrate that contaminant concentrations do not exceed following maximum concentration limits: Contaminant Maximum Concentration Limit Carbon Dioxide * 10,300/ventilation rate Indoor Air Quality Management 01 3546-7 GREENGUARD Environmental Institute

Contaminant Maximum Concentration Limit Carbon Monoxide Total Volatile Organic Compounds (TVOC) Formaldehyde 4-Phenylcyclohexene (4-PCH) Other Individual VOC s Total Aldehydes Total Particles (PM 10) 9 ppm and maximum 2 ppm above outdoor levels Maximum 500 micrograms/cubic meter Maximum 27 parts per billion Maximum 6.5 micrograms/cubic meter Below odor and/or sensory irritation threshold and maximum 1/10 TLV Maximum 100 parts per billion Maximum 50 micrograms/cubic meter * Carbon dioxide monitoring is required only if building is occupied during testing. Ventilation rate is outdoor air requirement per person. Carbon dioxide measurement is differential between indoor and outdoor conditions, based on occupancy type as defined by ANSI/ASHRAE 62.1 and 62.2. G. For each sampling location where maximum concentration limit is exceeded, conduct additional flush-out with outside air and retest specific contaminant until maximum concentration limit is achieved. Collect samples for retesting from original sampling location. END OF SECTION Indoor Air Quality Management 01 3546-8 GREENGUARD Environmental Institute