LESSONS LEARNED FROM 10 YEARS OF LEAK DETECTION SURVEYS ON GEOMEMBRANES



Similar documents
Design Algorithm for the Puncture Resistance of PVC Geomembranes for Heap Leach Pads

PVC Liner for Heap Leach Pad

CHAPTER 13 LAND DISPOSAL

Mechanically stabilized layers in road construction

High Performance PSA in Sheet Membrane in Water Protection

THE USE OF GEOSYNTHETIC CLAY LINERS IN HEAP LEACH PADS

Liner system design for tailings impoundments and heap leach pads

Secondary Containment: Regulations & BMPs. Beth Powell Vice-President and General Manager New Pig Energy bethp@newpigenergy.com

CONSTRUCTION QUALITY ASSURANCE (CQA) PLAN DOMINION CHESAPEAKE ENERGY CENTER INDUSTRIAL SOLID WASTE LANDFILL PERMIT #440 CHESAPEAKE, VIRGINIA

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Exposed Geomembrane Covers (EGCs) for Landfills

USE OF GEOSYNTHETICS FOR FILTRATION AND DRAINAGE

GRI Test Method GM19* Seam Strength and Related Properties of Thermally Bonded Polyolefin Geomembranes

Technical Note by G.L. Sivakumar Babu, H. Sporer, H. Zanzinger, and E. Gartung SELF-HEALING PROPERTIES OF GEOSYNTHETIC CLAY LINERS

Product Guide Specification

How To Model Soil On Gri

Well Site Spill Protection: Impacts, Trends and Technologies for Preventing Releases to Water Sources

2. Test Record - All records of analysis and tests shall be kept in suitable forms approved by the Bureau of Indian Standards.

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

Division 2 Section Section 02795

Geosynthetic Mining Solutions at Copper Tailings Dams: A Review of the State of Practice in Chile.

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Best Practices in Roof Design: Sustainable Energy Efficient Reroofing

Permeable Pavement Construction Guide

1.34 WASTE CONTAINMENT AND SITE REMEDIATION TECHNOLOGY TAKE-HOME FINAL EXAM DUE FRIDAY MAY 7, 2004 AT 9:30 AM

Secondary Containment Comparison ATI Ultra COAT vs HDPE

Safety containment systems for hydrocarbon tanks

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

NRC INSPECTION MANUAL

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Laboratory and Field Performance Assessment of Geocomposite Alternative to Gravel Drainage Overliner in Heap Leach Pads

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Product Information. Tel: x2426 or x2443 Fax:

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

EXPERIMENTAL EVALUATION OF THE BIOLOGICAL CLOGGING OF DRAINAGE GEOCOMPOSITE AT THE BOTOM OF LANDFILL

RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas

GSI. Geosynthetic Institute GRI. 475 Kedron Avenue Folsom, PA USA TEL (610) FAX (610) GII GAI GCI. GRI Test Method GM21

Oil and Gas Containment Systems

Section 2100-Trenching and Tunneling

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

Prefill and Water Balance Criteria. Division of Water Quality Municipal Wastewater Treatment

synthetic waterproofing systems

APPENDIX C MOISTURE GUIDELINES & MOISTURE TESTING

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

GRI-GT13(a) Specification Geotextile Separation for Roadways (ASTM Test Method Based)

GRI Standard Practice GT7 * Determination of the Long-Term Design Strength of Geotextiles

Non Invasive Roof Leak Detection Using Infrared Thermography

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)

Current opportunities of sprayed waterproofing membrane. Frank Clement Technical Manager Sprayable Membranes MEYCO Global Underground Construction

CONSTRUCTION MANAGER S WEEKLY PROGRESS REPORT

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

SECTION 311 PLACEMENT AND CONSTRUCTION OF CEMENT TREATED SUBGRADESOIL CEMENT BASE COURSE

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

Lightweight Partition Design for Residential and Commercial Buildings

Waterproofing Problems: A Simple Explanation, A Simple Solution

DEFECTS IN SHEET ROOFING THAT IMITATES ROOF TILES AS A RESULT OF THEIR ANCHORAGE

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

Drainage Solutions and Water Treatment / Single-wall corrugated drainage tubing is ideal for agricultural and. Durable Economical Wide range of sizes

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL Pre-Insulated Piping

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Moisture and Resilient Floor Covering

Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation by Tunnelling

Operations and Maintenance Guidelines for Coal Ash Landfills Coal Ash Landfills are NOT the Same as Subtitle D Solid Waste Landfills

Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles

Leakage Management & Control

Acceptance Codes APPENDIX - A. Acceptance Criteria

rhuesker HUESKER HUESKER HUESKER HUESKER HUESKERr HUESKER HUESKER HUESKER HUESKERHUES Product- Portfolio HUESKER Engineering with Geosynthetics

Waterproofing of Tunnels under Water Pressure

AdMaS centre Structure of the centre: Development of Advanced Building Materials Development of Advanced Structures and Technologies

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

GRI Test Method GM13* Test Methods, Test Properties and Testing Frequency for High Density Polyethylene (HDPE) Smooth and Textured Geomembranes

Attachment G-1: Pit Latrine Diagram. Fig E.1a: Pit Latrine. Fig E.1b: Plan View of Twin Pits

GEOTEXTILES IN ROAD CON- STRUCTION, MAINTENANCE AND EROSION CONTROL

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

The following are just a few of the advantages that Techno-Solis offers you as a solar contractor: Contact Us!

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

The Most Advanced Name in Drainage Systems. Geotextile Products

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS

Thermo-Flo Basement Waterproofing System. B-Dry System, Inc. 455 South 4th Street, Suite 350 Louisville, KY 40202

TECHNICAL REVIEW OF SECONDARY CONTAINMENT SYSTEM TECHNOLOGY FOR ALASKA

Jon E. Zufelt, PhD, PE ERDC-CRREL Anchorage, Alaska

MaxCell Technical Manual Design Parameters

PRESENT ISSUES FOR CENTRE DE LA MANCHE DISPOSAL FACILITY

Technical Specifications BIO-BLOK 80 HD G

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

DESIGN GUIDELINES FOR EARTH RETENTION

BRO: the Dutch Key Register of the Subsurface

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

Transcription:

LESSONS LEARNED FROM 10 YEARS OF LEAK DETECTION SURVEYS ON GEOMEMBRANES B. FORGET, A.L. ROLLIN and T. JACQUELIN SOLMERS INC., 1471 Lionel-Boulet Boulevard, Suite 22, Varennes J3X 1P7, Quebec, Canada SUMMARY Statistics obtained from geoelectric leak detection surveys performed on more than 89 projects totalling 2 652 000 m 2 are presented. Although many papers have been previously published on this topic, few authors have gone as far as to identify leak densities on geomembranes (exposed and covered) with respect to their thicknesses, the application or absence of a Construction Quality Assurance (CQA) program and water puddle leak detection survey on exposed geomembrane prior to the placement of a covering material. Results obtained within this investigation show that the average leak density on exposed geomembranes (many types and thicknesses) that were installed under a rigorous CQA program is approximately 4 leaks per hectare. Conversely, the statistics show a sharp climb, to 22 leaks per hectare, in the absence of such a CQA program. The situation was found to be similar with covered geomembranes: a negligible leak density (0.5 leaks/ha) found on geomembranes installed under a strict CQA program and a prior water puddle leak detection survey on the exposed geomembrane, climbing sharply to a density of 16 leaks/ha in the absence of both a CQA program and the water puddle leak detection survey. 1. INTRODUCTION Leak detection surveys performed on exposed geomembranes (totalling 2 291 000 m 2 ) and covered geomembranes (totalling 361 000 m 2 ) during a 10 year period, applied to 89 projects located in 8 different countries have been analyzed in order to complement recently published data and to stress the importance of the implementation of rigorous Construction Quality Assurance (CQA) programs during geomembrane installation. The data collected was used to calculate the number of leaks per hectare (leak density) for each project, and to register the types and size of located leaks. The surveyed sites were lined with HDPE, PVC, or bituminous geomembranes. Two different leak detection techniques used to verify the integrity of a geomembrane are presented: the water puddle technique as used on exposed geomembranes either during or after their installation and the dipole technique as applied on geomembranes covered with a soil layer.

Statistics indicating a global decrease in the number of leaks found on sites where a rigorous construction quality assurance program is implemented are then discussed. In the context of this article, a rigorous CQA program is defined as a constant surveillance by an expert who possesses recognized expertise in geomembrane installation during all of the liner installation phases, including subgrade preparation, liner installation, seaming procedures and covering of the geomembrane. 2. GEOELECTRIC LEAK DETECTION TECHNIQUES Geoelectric leak detection techniques used on geomembranes have been described in many publications, such as Peggs (1989, 1990, 1993), Darilek et al. (1988, 1989), Laine et al. (1989, 1991, 1993) and Rollin et al. (1999, 2002, 2004), and in standards such as ASTM D6747 (Standard Guide for Selection of Techniques for Electrical Detection of Potential Leak Paths in Geomembranes), ASTM D7002 (Standard Practice for Leak Location on Exposed Geomembrane Using the Water Puddle System) and ASTM D7007 (Standard Practices for Electrical Methods for Locating Leaks in Geomembranes Covered with Water or Earth Materials). The water puddle method consists in the creation of a potential difference between a soil under an exposed geomembrane and a puddle of water projected from a diffuser onto the surface. Most geomembranes are highly resistant electrical insulators and inhibit electrical currents. As soon as water percolates through a perforation and reaches the supporting soil, a bridge is created between these two potentials which generates an electrical current. A detector signals the presence of an infiltration to the operator (via acoustical and visual signals). This technique permits the detection of leaks with dimensions of 1 mm 2 or greater (ASTM D7002). On-site preparation is minimal and generally permits the survey to proceed during the geomembrane installation. The prospecting rate is approximately 5000 m 2 /day/operator, depending on site conditions. To achieve this survey rate, a continuous water supply of approximately 4 m 3 /day/operator is necessary. This water supply may be provided from a tanker or a direct connection to a municipal network. If a water supply proves difficult, the use of a closed circuit with a low point is also possible. Figure 1 provides a general schema of the water puddle method. Figure 1. Water puddle technique on exposed geomembranes.

In the dipole leak detection technique, an electrical potential is applied between the covering material above the geomembrane and the soil below it. Since most synthetic geomembranes are effective electrical insulators, the presence of a leak creates a localized passage of current, which perturbs the potential field in a characteristic way. Leaks are located by recording potential readings with the dipole at predetermined grid densities. Under moderate climatic conditions, on-site preparation is minimal. Spraying water on the covering soil surface might be necessary to insure good contact with the dipole under very dry conditions. The detection limit is variable but generally allows detection of holes with dimensions of 6 mm 2 or greater (ASTM D7007). Figure 2 provides a general schema of the dipole method. Figure 2. Dipole technique on covered geomembranes. 3. LEAK DENSITIES - DIFFERENT TYPES AND THICKNESSES OF GEOMEMBRANES The results obtained from 57 geoelectric leak detection surveys performed on exposed geomembranes (HDPE, PVC and bituminous) of different thicknesses are presented in Figure 3. The leak densities used in this investigation were calculated using data collected from the leak detection surveys. The majority (80%) of the projects where the liner installation was performed using a rigorous CQA program had very low leak densities, ranging from 0 to 7 leaks per hectare, with an average of 4 leaks per hectare. The remaining 20% of projects, which included a CQA program, had leak densities greater than 7. On the other hand, an average leak density of 22 leaks per hectare was calculated for projects without a rigorous CQA program. An analysis of eight ( 8 ) projects performed using a rigorous CQA program that had leak densities greater than 7 leaks per hectare indicated the following: In one project, the geomembrane installed in the proximity of a rock wall was not properly protected from falling rocks puncturing the geomembrane; In another project, seaming problems were encountered during the installation caused by the inexperience of the installer; In a third project, extensive extrusion welding caused half of the leaks detected;

In the remaining five projects, the lined areas were very small (between 600 and 5310 m 2 ) which rendered the leak density analyses biased. 30% Comparison of Projects Completed With and Without Construction Quality Assurance Exposed Geomembrane (57 Projects, 2 291 000 m 2 total) % of projects 25% 20% 15% 10% With CQA - 43 projects Without CQA - 14 projects 5% 0% 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 leaks / hectare Figure 3. Leak Densities With and Without a Rigorous CQA Program (Exposed Geomembranes). For leak detection surveys performed on covered geomembranes, where both a rigorous CQA program and a water puddle leak detection survey on exposed geomembrane during installation were implemented (corresponding to approximately 80% of the projects), the calculated leak density was found to be almost negligible, approximately 0.5 leaks per hectare. Conversely, an average leak density of 16 leaks per hectare was found for projects that did not implement a strict CQA program. 4. LEAK DENSITIES - HDPE GEOMEMBRANES The data obtained for different HDPE geomembrane thicknesses was gathered to determine the influence on the quantity of perforations during installation. The survey results have been grouped as exposed and covered geomembranes. Columns 1 and 2 of Table 1 present the results of the leak densities for exposed geomembranes with and without CQA implemented during installation. The results obtained for covered geomembranes are presented in columns 3 and 4. The surveys on projects with deficiencies at the design level, and projects with a total surveyed area of less than 10 000 m 2, were discarded in order to permit an objective comparison of the influence of CQA programs and leak detection surveys.

Table 1 - Leak Density Comparison (HDPE Geomembranes). Exposed HDPE Geomembranes (Water Puddle) Covered HDPE Geomembranes (Dipole) Column 1 Column 2 Column 3 Column 4 Geomembrane Thickness With CQA Without CQA With CQA and geoelectrical leak survey (water puddle) before covering Number of leaks per hectare (prospected area m 2 ) Without CQA and no geoelectrical leak survey (water puddle) before covering 2.0 mm 3.2 (362 460) N/A (0) 0.2 (170 190) 15.6 (50 600) 1.5 mm 5.1 (66 880) N/A (2 760) N/A (0). 24.7 (10 500) 1.0 mm 20.5 (17 070) 31.5 (313 770) N/A (1110) N/A (0) N/A: Data nonexistent or insufficient to enable a good representation. As intuitively expected, leak density was found to decrease as the thicknesses of the HDPE geomembranes increased. However, it was not found to be inversely proportional to the thickness of membranes installed where a rigorous CQA program was implemented: leak densities of 20.5, 5.1, and 3.2 leaks per hectare, respectively for 1 mm, 1.5 mm, and 2 mm thick exposed geomembrane were found. As shown in Table 1, the leak densities obtained from projects without a rigorous CQA program correspond well with the data presented by Rollin et al. (EUROGEO 2004), Nosko et al. (2000), and Phaneuf et al. (2001). More important is the fact that the calculated leak densities for applications where a rigorous CQA program was implemented are greatly reduced and correspond better with the densities forecasted by Giroud (1989). Another essential observation arises from efforts to determine the number of perforations resulting from the installation of a covering material on top of a geomembrane. A comparison of the data for exposed and covered 2 mm thick HDPE geomembranes in projects where a CQA program was implemented (columns 1 and 3 in Table 1), indicating respective densities of 3.2 and 0.2 leaks/ha, leads to the conclusion that only 6% of the perforations were caused during the covering material installation. In a 1996 survey reported by Nosko et al., and one in 2001 by Phaneuf et al., the results obtained in landfills indicated that 73% of damage occurs when the soil layers are placed on top of the geomembranes, 24% occurs during geomembrane installation, and 2% occurs during the post construction phase. They concluded that, contrary to the general perception, most damage detected in landfills occurs during covering layer installation and is not caused by improper seaming. This conclusion is probably valid only in cases where no rigorous CQA program has been implemented.

5. LEAK TYPES - HDPE GEOMEMBRANES An analysis was performed to determine the breakdown of the four types of perforations generally found on geomembranes and identified as faulty welds, tears, cuts, and punctures. Perforations can be caused during the welding process and include separation due to poor double fusion welds, perforations during the fusion process, insufficient water tightness or perforations as a result of faulty extrusion welds. Tears are generally caused by difficulties in handling the geomembranes during installation or by heavy equipment traffic used during the covering phase. The installer is most likely to be responsible for damage due to cuts. Finally, punctures arise from contact with static objects (such as sharp edged stones and gravel) left on or under the geomembranes. Figure 4 presents a breakdown of the different causes of perforations. The first graph considers the data obtained from exposed 2 mm HDPE geomembranes installed using a rigorous CQA program, and the second presents the results from exposed 1 mm HDPE geomembranes in the absence of a CQA program. It must be noted that this comparison deals with 2 variables due to the complete lack of data concerning 2 mm geomembranes installed without a rigorous CQA program. Breakdown of leak types on exposed HDPE geomembrane 1 mm thick geomembrane - without CQA 31.5 leaks/hectare (313 770 m 2 ) Breakdown of leak types on exposed HDPE geomembrane 2 mm thick geomembrane - With CQA 3.2 leaks/hectare (362 460 m 2 ) Welds : 18% 5.7 leaks/ha Punctures : 33% 1.1 leaks/ha Welds : 28% 0.9 leaks/ha Tears : 6% 1.9 leaks/ha Punctures : 74% 23.6 leaks/ha Cuts : 2% 0.6 leaks/ha Cuts : 29% 0.9 leaks/ha Tear : 10% 0.3 leaks/ha Figure 4. Breakdown of Leak Types (Exposed HDPE Geomembranes). The analysis of the leak types, as presented in Tables 1 and 2, permits the measurement of the impact of the thickness and of CQA implementation on the leak densities. A comparison of Tables 1 and 2 permits the following conclusions: Confirming what has been previously published on this topic, approximately 30% of leaks are found at seam edges, and 70% are found on the panels; There is no correlation between the geomembrane thickness and the implementation of a CQA in regard to the number of knife cuts; The number of tears found is six (6) times greater for the 1 mm geomembrane without a CQA program than with implementation of a CQA program (1.9 vs. 0.3 leaks/ha); The number of faulty seams is six (6) times greater for the 1 mm geomembrane without a CQA program than with implementation of a CQA program (5.7 vs. 0.9 leaks/ha);

The number of punctures is twenty one (21) times greater for the 1 mm geomembrane without a CQA program than with implementation of a CQA program (23.6 vs. 1.1 leaks/ha). 6. LEAK DIMENSIONS - HDPE GEOMEMBRANES Even though the leak densities on 2mm thick HDPE covered geomembranes are very low after the application of a rigorous CQA program (0.2 leaks/ha), it is important to mention that the vast majority of these perforations are caused by the heavy equipment traffic used during the installation of the covering materials. Consequently, the sizes of these perforations were found to be relatively large. This is corroborated by Nosko and Touze Foltz (2000) that characterised the dimensions of the perforations as a function of their type. Table 2 presents their results for covered and exposed geomembranes, while not taking into account the thickness or the presence or absence of a rigorous CQA program. It is interesting to note that the perforations caused by heavy machinery represent 75% of the tears greater than 10 cm 2. Table 2. Perforation Sizes and Types (Nosko and Touze Foltz, 2000). Diam. Size (cm 2 ) Stones (%) Heavy equipment (%) Seams (%) Cuts (%) Installer directly (%) Total < 0.5 332 11.1 - - 115 43.4 5 8.5 - - 452 0.5 2.0 1720 57.6 41 6.3 105 39.6 36 61.0 195 84.4 2097 2.0 10 843 28.2 117 17.9 30 11.3 18 30.5 36 15.6 1044 > 10 90 3.0 496 75.8 15 5.7 - - - - 6701 Amount 2985 654 265 59 231 4194 Total 71.17% 15.59% 6.32% 1.41% 5.51% Figure 5 shows a typical geomembrane perforation originating from heavy equipment traffic on the covering material located at the cell bottom.

Figure 5. A one meter tear discovered using the dipole method, caused by heavy equipment during covering material placement. 7. CONCLUSION The water puddle and dipole techniques used in geoelectric leak detection surveys are standardized methods (ASTM) that enable a control of the global integrity of the geomembranes during the installation and covering phases. The vast majority of leaks discovered after the geomembrane installation (exposed geomembranes) are found in the panels (up to 70 %), not at the seams. It is therefore mandatory to check the total lined area to ensure the geomembrane integrity and not only to implement destructive and non-destructive seams testing. The relationship between the leak density and the presence or absence of a rigorous CQA program and geomembrane thickness has been found to be crucial. It was found that most perforations are caused during geomembrane installation and not during its covering phase whenever a rigorous CQA program is implemented. However, larger tears and holes are usually encountered during the geomembrane covering phase. For landfills, a rigorous CQA program combined with leak detection surveys on exposed and covered geomembranes is recommended. Even though designers use high factors of security to reduce the possibility of perforations in many projects, leak detection surveys are an alternative that significantly reduce these factors, resulting in a reduction of the thickness of the covering material layers, the protective geotextiles and the geomembranes themselves. In certain cases substantial economic savings would result. A leak detection survey is a useful tool in assuring the integrity of a containment project using geomembranes. REFERENCES ASTM D6747 Standard Guide for Selection of Techniques for Electrical Detection of Potential Leak Paths in Geomembranes. ASTM D7002 Standard Practice for Leak Location on Exposed Geomembrane Using the Water Puddle System.

ASTM D7007 Standard Practices for Electrical Methods for Locating Leaks in Geomembranes Covered with Water or Earth Materials. Darilek G.T. & Parra J.O. (1988). The Electrical Leak Location Method for Geomembrane Liners, USEPA/600/S2-88/035, Sept. Darilek G.T., Laine D. & Parra J.O. (1989). The Electrical Leak Location Method for Geomembrane Liners, Proceeding of Geosynthetics 89, IFAI, pp 456-462, San Diego. Giroud J.P. & Bonaparte R. (1989). Leakage through Liners Constructed with Geomembranes, II: Composite Liners, Geotextiles and Geomembranes, vol 8, no 2, pp 71-112. Laine D.L. & Miklas M.P. (1989). Detection and Location of Leaks in Geomembrane Liners Using an Electrical Method, Proceed. 10 th Nat. Conf., Superfund 89, Washington, Nov. Laine D.L. (1991), Analysis of Pinhole Seam Leaks Located in Geomembrane Liners Using the Electrical Leak Location Method, Proceed. Geosynthetics 91, Atlanta, pp 239-253. Laine D.L. & Darilek G.T. (1993). Locating Leaks in Geomembrane Liners of Landfills Covered with a Protective Soil, Proceed. Geosynthetics 93, vol 3, pp 1403-1412, April. Nosko V., Andrezal T., Gregor T. & Garnier P. (1996). Sensor Damage Detection System The Unique Geomembrane Testing Method, Proceed. EuroGeo, Netherlands pp 743-748. Phaneuf R. & Peggs I.D. (2001). Landfill Construction Quality: Lessons Learned from Electrical Resistivity Testing of Geomembrane Liners, Geotechnical Fabrics Report, vol 19, no 3, April pp 28-35. Peggs I.D. & Pearson D.L. (1989). Leak Detection and Location in Geomembrane Lining Systems, ASCE Annual meeting, Fort Lauderdale, September. Peggs I. (1990). Detection and Investigation of Leaks in Geomembrane Liners, Geosynthetics World, vol 1, issue 2., winter, pp 7-14. Peggs I.D. (1993)a. Practical Geoelectric Leak Surveys with Hand-Held, Remote and Water Lance Probes, Proceedings of Geosynthetics 93, IFAI, pp 1523-1532, Vancouver. Peggs I.D. (1993)b. Advances and New Thinking in Landfill Liner Construction Quality Assurance Practices, Proceedings of Sardinia 93, CISA Cagliari, pp 121-128. Rollin A.L., Marcotte M., Jacquelin T. and Chaput L., (1999). Leak Location in Exposed Geomembrane Liners Using an Electrical Leak Detection Technique, Proceedings of Geosynthetics 99, Boston, pp 615-626. Rollin A.L., Marcotte M., Chaput L., Caquel F. (2002). Lessons Learned from Geo-electrical Leaks Surveys, Proceedings Geosynthetics 2002, Nice pp 527-530. Rollin A.L., Jacquelin T., B. Forget, Saunier P. (2004). A Guide to Detect Leaks on Installed Geomembranes, Proceedings EuroGEo, Munich, pp 235-240.