TraceTek. Leak Detection and Location Systems FIND LEAKS BEFORE THEY FIND YOU



Similar documents
Industrial Strength Leak Detection

water leak detection

WATER LEAK DETECTION FIND LEAKS BEFORE THEY FIND YOU

Liebert COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPACES. Liebert Liqui-tect. M o n i t o r i n g S o l u t i o n s

A cure for water damage in real estate

ASX ITS Co-location Hosting Solution

How to Prevent Liquid Damage Property Losses

HVAC Processes. Lecture 7

Data Center Commissioning: What you need to know

InHome Water Leak Detection Package

Ammonia Detection System Codes and Design Specifications

later damage - Loss ControL

Oil and Coolant Circulating Heating System. Model - OCSM

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

KEMPER Leak Detection System

, User s Manual

MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

N4385A / N4386A Distributed Temperature System (DTS)

DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION

Executive Summary. Technical Description

COWENS RISK SOLUTIONS WATER DAMAGE PREVENTION

Best Practices for Wire-free Environmental Monitoring in the Data Center

Protecting Your Home From Water Damage

This section gives you some helpful information and tips on running your home and the equipment in it.

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

contractors, etc. and establish relationships with lease and rental companies.

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Distributed Temperature Sensing - DTS

Leak Detection System

Transformer Deluge Systems

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Choosing Close-Coupled IT Cooling Solutions

Utility Distribution Systems

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation

Mechanical, Plumbing, and Fire Protection Conditions

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Ceiling Mount Air Handler Manual

DATA CENTRE DATA CENTRE MAY 2015

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Response, Reliability and Results. for Managed Property

Plumbing Identification and Damage Assessment Guide

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

HIH-4000 Series Humidity Sensors

GenStore Archive Cabinet

Data Center Infrastructure & Managed Services Outline

ADVICE NOTE WATER LEAKS. How to prevent water leaks in your flat

Current as of 11/10/08 1 of 1

Enterprise Remote Monitoring

Predictive Maintenance in a Mission Critical Environment

APC APPLICATION NOTE #112

Basement Flooding: Preventing Future Damage

Facilities Maintenance Standards rev

Medium voltage arc flash eliminator units VAM 3ED,

Technical Specifications for West Campus Data Center HVAC System

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

WHAT IS INFRARED (IR) THERMOGRAPHY

in other campus buildings and at remote campus locations. This outage would include Internet access at the main campus.

MEDIAROOM. Products Hosting Infrastructure Documentation. Introduction. Hosting Facility Overview

NeuStar Ultra Services Physical Security Overview

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

Thermal Storage System Provides Emergency Data Center Cooling

Electric Water Heater

Planned and Emergency Utility Outage Guidelines

Prevention. Cause. Causes: Groundwater seepage through the basement walls. Prevention: OPEN 24 Hours. Surface runoff. Sanitary sewer backup

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Location. Central Business District. Ataturk Airport IFC. Sabiha Gökçen Airport

Planned, Limited Notice and Emergency Outage Guidelines


Session 14 Cable Support Systems

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

A COMPARISON OF WATER LEAK DETECTION AND SHUTOFF SYSTEMS

TELECOMMUNICATION SYSTEM HAZARD MITIGATION STRATEGIC PLANNING

Fighting Fire in Sprinklered Buildings. Student Guide

AT&T Internet Data Center Site Specification Chicago Area (Lisle, IL)

Underground Storage Tanks

bout your house before you start Renovating Your Bathroom

White Paper: Server Room Environmental Monitoring

Medical Air Systems: Scroll

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

IP Box Camera ACM Ver Hardware User s Manual

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Designed for multi-injector endurance testing, the

Presentation to Senate Select Committee on Government Facilities: Deferred Maintenance for State Supported Living Centers and State Hospitals

Network Design. Yiannos Mylonas

The following are general terms that we have found being used by tenants, landlords, IT Staff and consultants when discussing facility space.

DEALING WITH PLUMBING AND HEATING EMERGENCIES

Transcription:

TraceTek Leak Detection and Location Systems FIND LEAKS BEFORE THEY FIND YOU

tank room chiller plant room services riser executive office / board room services core vending areas IT facility network / server / equipment room toilets / washroom kitchen / canteen fan coil units archives perimeter heating / cooling LV / HV switch room lift pit plant room archives storage UPS room PABX / comms room generator room / oil storage cable entry chamber

DON T TAKE THE RISK ven small leaks in the wrong places cause downtime, disruption, and costly damage. And the aftermath ties up resources in clean-up and repair. Why suffer these costs when reliable, distributed leak Edetection is available? TraceTek technology lets you detect leaks at their source even pinpoint their location so you can stop damage before it starts. Thousands of facilities throughout the world rely on TraceTek leak detection systems to protect data and telecommunications centers, commercial buildings of all kinds, libraries and archives, and museums. DISTRIBUTED VS. POINT SENSING With the point sensing approach to leak detection, liquid must reach the location of a probe to trigger an alarm. Depending on the circumstances, a leak may grow or spread considerably before it reaches an individual probe. With distributed sensing, liquid is detected if it makes contact anywhere along the length of sensing cable that monitors an entire area. Routing the cable near likely sources of leaks and spills ensures early detection. A locating module even displays the distance to the leak, enabling quick and effective response. Point Sensing Distributed Sensing A TraceTek locating system detects the leak at its source, signals the alarm, and displays the exact position of the leak. By referring to a map of the system layout (supplied as part of the TraceTek system), you can quickly locate the leak source. TraceTek TTDM 1

UNDETECTED LEAKS EVEN SMALL ONES CAN BE DEVASTATING PROBLEM AREAS: Heating/cooling water flow and return piping Air conditioning fan coil units Condensate drains Fire sprinkler systems Toilets, drains, and related plumbing Basements Backflow preventors Roofs Servery and vending machines Overhead pipe runs and trays Generators and fuel systems POTENTIAL CONSEQUENCES: Business disruption hat happens if the plumbing above a building s network equipment springs a leak? Or a bathroom sink next to an order processing center backs up? WThe amount of business disruption that s possible is staggering particularly if the leak goes unnoticed for any length of time. CATCH IT EARLY, STOP IT FAST As soon as even a little water touches the sensor cable, the TraceTek system triggers an alarm. Because TraceTek cable senses water along its entire length not just at certain isolated points you can rely on early detection. In offi ce environments the TraceTek system helps avoid costly damage and disruption that can result from leaks. Service interruption and network outages Loss of telephone service Liability for damage to tenant s equipment Damage to furnishings Cleanup costs APPLICATION AREA: Raised floor computer facility ISP/co-location facilities Fiber optic switch sites Racked equipment Control rooms Trading rooms Archival storage Executive offices PBX rooms, server equipment rooms FLEXIBLE TO FIT ANY APPLICATION The design flexibility of the TraceTek system allows you to select the monitoring approach and layout you need no matter how simple or complex your requirements. TraceTek systems can be easily integrated into a building management system. NO DOWNTIME TraceTek water sensing cable is designed to dry almost instantly, making it easy to quickly get the system up and running again after an alarm. As soon as liquid is cleared away from the cable, you can restore the system to operation. Museums, historic buildings 2

HVAC equipment TraceTek cable monitors water-heated or cooled ventilation equipment. If a leak is detected, the system automatically shuts off a supply valve to prevent costly damage to offi ce equipment. Telephone switch gear TraceTek sensing cable monitors overhead piping to guard sensitive telecommunications hardware. The TraceTek module can instantly relay an alarm to your building management system or alarm panel. Mehchanical or electrical equipment areas TraceTek systems provide 24-hour leak detection on unmonitored basement and equipment floors. TraceTek fuel-sensing cable is available for backup diesel generators and other fueling applications. Building service columns Leaks in vertical service columns often propagate to several floors. TraceTek systems offer layout fl exibility to handle widely distributed areas with branches or zones. Sensing cable on each floor provides early and quick detection and the alarm and locating module pinpoints the location. 3

DOWNTIME SPELLS DISASTER PROBLEM AREAS: Chilled water piping Air conditioning units f you design or manage a computer network, a multi-tenant server facility, or telecommunications facility, you know the importance of keeping systems continually on-line. Service reliability is a key element of your value Iproposition. To avoid downtime and disruption, consider installing a system that Overhead piping Cracks in substructure Roofs Toilets, drains, and related plumbing POTENTIAL CONSEQUENCES: Placed in the subfloor of a computer room, the TraceTek system protects your computer equipment by detecting a leak early and even locating its source. Downtime Cleanup costs and disruption Loss of telephone network service Equipment damage can find a leak at its source, when it occurs and can pinpoint its location. LOCATE THE LEAK FAST For hidden or unmonitored areas, the TraceTek system not only provides early detection, but also a digital readout of the distance to the leak. The TraceTek system map (supplied as part of a TraceTek locating system) leads you to the leak, so you can locate the source, solve the problem, and keep your equipment up and running. MODULAR NETWORK, DISTRIBUTED SENSING As modern data and network facilities have grown in complexity, the TraceTek system has added design and integration flexibility. Single TraceTek alarm panels can now monitor up to 32 individual circuits or inexpensive Sensor Interface Modules can provide leak detection data directly to Building Management Systems. Network equipment Network servers and routers are sometimes housed in rooms not specifi cally designed for their protection. TraceTek cable can be installed to monitor hazards wherever they occur. For example, cable is placed at the perimeter of subfl oors and in trays below overhead piping. 4

Computer rooms In a raised-fl oor computer room, the TraceTek system provides distributed coverage that fi nds a leak before it becomes a problem. Cable is laid out at the perimeter of a room, near drains, water piping, and air conditioning. Telephone equipment rooms The TraceTek system protects you from loss of telephone service by providing monitoring directly below water piping and at a room s perimeter. Leaks can be detected early and stopped before disruption occurs. 5

ONE LEAK CAN RUIN YOUR COLLECTION PROBLEM AREAS: Aged water supply piping Basements Fire sprinkler systems Janitorial maintenance areas Heating and cooling water, flow and return Toilets, drains, and related plumbing POTENTIAL CONSEQUENCES: Loss of irreplaceables: artwork n a museum, archive, library, or storage setting, any undetected leak is truly a disaster. Sources include roof leaks, basement seepage, and in most buildings a disconcerting variety of plumbing: overhead sprinklers, water Isupply piping, even bathrooms and water fountains. The flexibility of the TraceTek system allows you to design the monitoring and cable layout required no matter how simple or complex. You can install leak detection systems ranging from 1 meter to 48 kilometers of sensor. Whether you require a simple alarm system for a single room or a multiple circuit sensor network for a large facility, there is a TraceTek system to fit your needs. historic archives business records Costs of restoration Facility closures In areas where irreplaceable valuables are stored, the TraceTek system provides continuous monitoring and leak detection. Archives with sprinkler systems TraceTek sensing cable is installed in a tray below sprinkler system piping. By directly monitoring the sprinkler system and water supply piping, leaks are detected early, before they can do a lot of damage. 6

Washrooms and service areas Whatever the risk to your valuables, the TraceTek system offers the flexibility to install a simple alarm system or a complex, multibranch locating system. Basement storage TraceTek cable provides constant monitoring of unmanned locations such as basement storage areas, where overhead water pipes and seepage or flooding present risks. Early warning can help prevent disaster. 7

SIMPLE. RELIABLE. FLEXIBLE. Unique sensing cable Distributed sensing: by sensing liquid along its entire length, TraceTek cable makes it possible to detect leaks at their source Durable construction: small but rugged cable is extremely resistant to corrosion and abrasion Dries and clears quickly: cable construction leaves no place to trap moisture continuity wire Simple and sure detection circuit that can also locate Continual check of system integrity: TraceTek cable uses a four-wire construction. Monitoring the two circuit loops provides a continual and positive verification of system integrity. Simple and sure detection: liquid creates a circuit between the sensing wires to trigger an alarm no moving parts, no calibration. Accurate location: a TraceTek locating system pinpoints (0.1% precision) where liquid contacts the sensing cable. The locating module measures the current and the voltage drop in the second sensing loop and simply applies Ohm s law (R=V/I) Clear indication: LEDs clearly indicate system status monitoring, leak, or fault. signal wire sensing wire jacketed with conductive polymer (no exposed metal to corrode) end termination connects wires to make two circuit loops Modular for ease of design and installation Standard lengths of TraceTek cable quickly plug together so you don t need special tools to install the system. The modular design also means that you can easily add to the system in the future. Flexible with a choice of systems and interfaces to meet your needs There s a TraceTek system to meet your needs, whether you re looking for a simple detection system (for a small, isolated area) or for a complex, multi-branched locating system. All TraceTek modules have relays to signal detection of an alarm condition (for example, to a building management system). Our locating system also displays the distance to the leak. Our microprocessor-based alarm and locating module continues to monitor after a leak and realarms if any major change occurs. It keeps a log of events and has built-in systemwide diagnostic functions. In addition to alarm relays, its interfaces include a 4-20 ma current transmitter and an RS-232/RS-485 communications port. 8

Distributed By: ISO 9 0 01 Flow Control Tyco Thermal Controls Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification. Worldwide Headquarters Tyco Thermal Controls 300 Constitution Drive Menlo Park, CA 94025-1164 USA Tel 800-545-6258 Fax 650-474-7517 Fax-on-Demand 800-329-4494 info@tycothermal.com www.tracetek.com TraceTek and Raychem are trademarks of Tyco Thermal Controls LLC. Asia Tyco Thermal Controls 9th floor, Yeul-chon Building 24-1, Yeoido-Dong Youngdeungpo-ku 150-010, Seoul, Korea Tel 82 2-2129-7731 Fax 82 2-785-4700 Europe Tyco Thermal Controls Diestsesteenweg 692 B-3010 Kessel-lo Belgium Tel 32 16-351-231 Fax 32 16-558-5765 2002 Tyco Thermal Controls LLC H55474uk 04/02