Biological Microscope. Biological Microscope ECLIPSE E200



Similar documents
ISO9001 ISO Environmentally-friendly product All optical components in CX41 microscope use lead-free eco-glass.

Inverted Microscope. Inverted Microscope ECLIPSE TS100

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

MICROSCOPES & REFRACTOMETERS for laboratory, industry and food

How To Use An Asbestos Microscope

OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

The new standard in research microscopy

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

Care and Use of the Compound Microscope

EyeMag Medical Loupes from ZEISS Seeing is believing NEW! LED illumination

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10. Macro View. The first true macro fluorescence imaging system

euromex microscopen bv The Netherlands page1/16

Product Range Overview

Leica DM LS2 and DM LB2. Life Science System Microscopes with New Ergonomic Concept

POLARIZING MICROSCOPE BX51-P BX2 SERIES

SLIT LAMP BQ 900 Sophisticated microscopy

LABORATORY MICROSCOPEs

Olympus BX51 Microscope & DP70 Digital Camera System

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

Firearms & Tool Marks Comparison Microscope. Discovery. Leeds Forensic Systems. Your Forensic Imaging Source

SERIE SZR. Stereomicroscopi da laboratorio. 13

Leica DM500 & DM750. A New Generation s Choice of Innovative Educational Microscopes

Living up to Life. Leica LAS Live Image Builder Dynamic Software for Fast Widefield Imaging and Extended Depth of Focus

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Living up to Life. Leica KL300 LED. Compact, modular cold light source for routine stereomicroscopes

PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES

digital quality control fail pass at your fingertips Smart Metrology Solutions.

Compound microscope (Hund)

EXPERIMENT #1: MICROSCOPY

VICKERS HARDNESS TESTER. HBS HBW Kc

Bullets, documents, tools: Compare for yourself - with optimum precision

18-270mm F/ Di II VC PZD for Canon, Nikon (Model B008) mm F/ Di II PZD for Sony (Model B008)

microscope OP-Dent-5

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

THE COMPOUND MICROSCOPE

Powerful Upright Microscope Solutions for Life Science and Clinical Applications

Press Release. Superior bending

AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)

The Kaps SOM -Series. Stereo Examination Microscopes for ENT Specialists. The variable space-saving system for every ENT practice

MIRAX SCAN The new way of looking at pathology

Leica MZ125. Modular high-performance stereomicroscope with 12.5:1 zoom

Agilent Television Power Consumption Testing. Application Note

GLobAL Dental Microscopes. Dentists First Choice

TAGARNO AS Sandøvej Horsens Denmark Tel: Mail: mail@tagarno.com

TECHNO PACK T LED. Now with MULTIPOINT 3.0 measuring software! The Latest Generation of the TECHNO PACK Product Range

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

ProScan DC Linear Servo Stage Technology

TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Profile Projector PH-3500

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Application Example: Automotive Testing: Optical 3D Metrology improves Safety and Comfort

HISTOLOGY LABORATORY. Microscope Orientation and Blood Smear Lab

SP AF 17~50 mm F/2.8 XR Di-II LD Aspherical [IF] (Model A16)

22 (21.5 viewable) Smart Display, Full HD, Rockchip Quad-Core, Optical touch, Android KitKat. VSD224

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

Inspection and Illumination Systems for Visual Quality Assurance. Large selection Attractive prices Tailored solutions. optometron.

DIGITAL MICROSCOPE VHX-5000 QUICK GUIDE

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Melting Point Range. with BioCote antimicrobial protection

2D & 3D TelePresence

Lighting. Midmark Animal Health Products

Quick Start Guide. Digital Inverted Microscope. The Microscope Evolved.

Rauserv Steam Sterilizers, Laboratory and Hospital Equipment. Brewery Laboratory Equipment

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Magnifiers. 4.5X Fingerprint Classifier Magnifier. 5X Fingerprint Magnifier A B C D

How To Use The Dc350 Document Camera

PRODUCT NO.: PT-P1SD PRODUCT NAME: Digital SD Slide Projector

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Colour Measurement Solutions for the Food Industry. Trusted by Over 70% of the Top 100 Global Food and Drink Companies*

LEICA DNA digital levels Advantages that move you ahead. LEICA DNA digital levels

Microscopes 2014 Microscopes PB Microscopes 1

Overview Image Acquisition of Microscopic Slides via Web Camera

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

Leica DNA digital levels Advantages that move you ahead

Review: Amscope Metallurgical Trinocular Microscope. Michael Reese Much FRMS EMS Bethlehem, Pennsylvania USA

Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03

Optical laser beam scanner lens relay system

Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!

Encoders for Linear Motors in the Electronics Industry

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

The upright transmitted microscope is most suited to our purpose of observing samples of compost, soil and compost tea, etc.

FlexFlash Instruction Manual Models SB FLXFLSH400W, SB FLXFLSH200W, SB FLXFLSHE400W, SB FLXFLSHE200W

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN

MICROSCOPY MARKETING GUIDE

Bloomberg 17 Inch Flat Panel Display. 29 April 2005 Version: 1.1

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Leica StereoZoom line. Complete solutions for industry, laboratory and training

Rodenstock Photo Optics

OPERATING INSTRUCTIONS Nikon TiE Deconvolution Microscope CCRB 1-220G

9.7" Microscope Tablet Camera (REALPAD 5.5) Introduction. Feature

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

OLYMPUS STUDENT MICROSCOPES IINSTRUCTION MANUAL I CBA& CBB MODELS

S300. Big Screen Viewing. Bright projection 2800 ANSI Lumens. SVGA resolution, 15,000:1 contrast ratio. Low ownership costs - up to 6500 hrs lamp life

Transcription:

Biological Microscope Biological Microscope ECLIPSE E200

Features exceptionally bright and uniform LED illumination and Nikon s high-quality optics. Ergonomic and anti-mold design ensures years of comfortable and stable use. High-intensity LED Eco-illumination The newly developed Eco-illumination provides enough brightness for both phase contrast observation and simple polarizing observation. With a fly-eye lens in the illumination system, uniform brightness is provided in the entire field of view. LEDs are environmentally friendly, consume less power than halogen lamps, and last approximately 60,000 hours, reducing costs and the need for frequent lamp replacement. The color temperature does not change when magnification is changed. A halogen illumination model is also available. Fly-eye lens 2

This compact small-sized clinical and laboratory microscope uses newly developed high-intensity LED illumination. The long-life LED illuminator is environmentally friendly as it reduces the need for frequent lamp replacement. A halogen illumination model is also available. The ECLIPSE E200 uses Nikon s CFI60 optical system highly-acclaimed infinity corrected optics used in Nikon research microscopes. The result is stunningly sharp and clear images with less chromatic aberration. With the ECLIPSE E200, Nikon has designed a simple and easy-to-use system that reduces fatigue from use over long periods. With a robust structure and anti-mold design, the ECLIPSE E200 offers high quality and accuracy that can be retained for years even in hot and humid environments. The ECLIPSE E200 offers exceptional operability and durability, and high-quality images. It can be used for various purposes, such as educational, clinical laboratory use and basic research. ECLIPSE E200-F (model with field diaphragm) ECLIPSE E200 3

Superb infinity optics, plus ergonomic touches optical system The CFI60 optical system combines Nikon s renowned CF optical design with infinity optics to overcome the limitations of the traditional infinity design. CFI60 optics provide longer working distances and higher NA s. These optics deliver startlingly clear images at any magnification because chromatic aberrations and curvature of field are both corrected over the entire field of view when the field number is 20 mm. Nikon developed dedicated CFI E Plan Achromat objectives exclusively for the E200. Also, you can use other highergrade objectives available for the ECLIPSE series whenever your laboratory situation calls for it. Anti-mold design Mold is a formidable enemy of microscopes. Before you know it, it can begin growing on the interior optical surfaces of the microscope and ruin performance. Using anti-mold paint, plus anti-mold agent sealed at critical places inside the microscope, the ECLIPSE E200 is designed to resist mold growth. In tests, an anti-mold treated unit was able to resist the growth of mold for three consecutive years at an average temperature of 30 ºC (86 ºF) and 80 % humidity. Anti-mold paint and agent 4

Ergonomic design equals comfortable operation Comfort is ensured allowing long hours of use, thanks to Nikon s thoughtful ergonomic design. This is the same design incorporated into Nikon s other laboratory and research-grade ECLIPSE series microscopes. For example, the focus knob and the stage handle are located equidistant from the operator, permitting one-handed operation in a natural posture without twisting the shoulders. Because these controls are low positioned, you can operate the microscope while resting your arms comfortably on the desk. Moreover, the low-profile stage makes exchange of specimen slides easy, while the low inclination angle tube provides comfortable viewing. E200 Conventional models Comparison of the positions of the stage handle and focus control knob Ergonomic binocular tube With this option, users can adjust not only the tube tilt angle, but the eyepiece length to suit their build, eliminating discomfort and strain during long hours of observation. A camera can be attached using the DSC port. *Use of this accessory in combination with other equipment may produce darker images around the periphery. *Must be attached directly to the main body. View angle is adjustable by 10º to 30º. Eyepiece length can be extended by up to 40 mm. E200 configured with an ergonomic binocular tube. Eye-level riser Up to two eye-level risers can be mounted to raise the height of the eyepoint 25 mm each for a total of 50 mm. Robust, vibration resistant construction One-piece construction from arm to base, a stage design where its up/down mechanism is located in the base, plus a wide footprint of 188.5 mm across the back all provide greater rigidity and resistance to vibrations, contributing to superior images. 5

Design ideas that ensure superb optical quality and incre CFI60 objectives Nikon s exclusive CFI60 objectives provide numerous benefits: longer working distances, high numerical apertures, flat images over the entire field of view with virtually no curvature of field when the field number is 20 mm. To match your laboratory requirements, the E200 provides a wide selection of objectives to choose from. These include the CFI E Plan Achromat objectives developed for the E200 or other higher-grade ECLIPSE series objectives. CFI E Plan Achromat objectives Tube The Siedentopf-type tube is inclined at 30º to ensure comfortable viewing in a natural posture. Designed for use by operators with different builds, this tube has a narrow minimum interpupillary distance of 47 mm, while the eyepoint height can be raised 34 mm when interpupillary distance is 64 mm by simply swinging the front part of the tube up 180º. For extremely tall users, eye-level risers are available to customize the microscope. Low position High position E2-TB Binocular Tube E2-TF Trinocular Tube *Eyepieces are optional. Eyepieces The E200 s eyepieces feature a wider field of view for a microscope of this class and are available in 10x (F.O.V. 20) and 15x (F.O.V. 12) types. These eyepieces also feature built-in diopter adjustment that allows the operator to adjust diopters separately for the right and left easily. In addition, these eyepieces accept measuring reticles that will always be in sharp focus with the specimen. Moreover, they can be locked preventing theft and eliminating the possibility of damage during transit. 6 F.O.V. 20 (E200) F.O.V. 18 (conventional model)

ased ease of use Refocusing stage Nikon has created a unique innovation. The Refocusing Stage eliminates the need to refocus the image manually, making specimen handling safer and easier. In this unique design, the stage can be instantly dropped by pushing it down to exchange specimens or oil the slide, then returns to the original position as soon as the hand is removed. The wide stage surface can accommodate two slide glasses at the same time. In addition, this stage has an array of features including: Wide stage surface with no rack sticking out of the stage Increased resistance to vibrations due to the design of the in-base focus mechanism Low-profile design that creates more space around the objective for increased freedom in specimen handling and easier operation A belt-drive mechanism to eliminate the projection of the rack at the edge of the stage for better ergonomics and smoother movement Removable specimen holder for fast hand scanning of slides Improved XY cross travel, providing the comfort and feel similar to Nikon s higher grade ECLIPSE series microscopes Upper limit stopper When using short-working-distance objectives such as 40x or greater, you can set the upper limit of the stage movement, so that the objective doesn t hit the specimen slide, protecting both from damage. Thanks to this feature, even novices or operators who need to change slides often can perform their job easily and quickly. The limit height can be set in two levels using a stopper bolt either at the standard position or 2 mm lower. This feature is very useful except when extraordinarily thick specimens are used. 2 mm Stage surface Cover glass Slide glass Upper limit (High) Upper limit (Low) Revolving nosepiece A reversed-type nosepiece creates more space at the front of the stage, making handling of specimen slides fast and easy. In addition, the CFI60 optical design eliminates extra optical elements in the nosepiece for enhanced image sharpness. Another advantage of CFI60 objectives is that their increased objective lengths and longer working distances provide more working space around the nosepiece. 7

Condenser Although the stage is low-positioned for comfort, there is ample space around the condenser for easy access. The condenser also features an aperture diaphragm that comes complete with position guide markings for respective E Plan objectives to make operation quick and easy. Safe and easy halogen lamp replacement Lamp replacement is now made even easier by simply opening the lens unit cover and replacing the lamp. Field diaphragm model available The E200-F has a built-in field diaphragm that allows the use of Koehler illumination. It features a field lens unit with a field diaphragm that has position guide markings for respective objectives to allow easy setting of optimal apertures. Field diaphragm with position guide markings E200-F 8

A wealth of accessories to broaden the range of microscopic applications Brightfield microscopy A dedicated Abbe condenser is available for brightfield observation. A blue filter enabling natural color observation can be attached to the condenser. E2 Abbe Condenser Phase contrast microscopy/darkfield microscopy Phase contrast observation at 10x, 20x and 40x is possible with a single phase annulus slider. The aperture diaphragm automatically opens when the slider is inserted into the condenser. A phase contrast slider for 100x observation is also available. Darkfield observation up to 40x is possible with the E2 Phase Condenser. GIF Filter Centering Telescope E2 Phase Condenser Phase Contrast Slider 10x-40x Phase Contrast Slider 100x Darkfield Slider CFI Achromat DL objectives for phase contrast Epi-fluorescence microscopy The E200-dedicated epi-fluorescence attachment is available for users who want to begin fluorescence observation. Although affordably priced, this attachment allows comprehensive epi-fluorescence as well as UV excitation observations. Epi-fluorescence accessories Simple polarizing microscopy This method is ideal for observing amyloid and crystals. To set up, install the polarizer over the field lens and the analyzer. Simple Polarizing Set C 9

Teaching heads Face-to-face* and side-by-side teaching heads are available. *Not recommended for use in conjunction with a photomicrographic system, because it makes the microscope top-heavy. Digital Sight series camera system When the trinocular tube is used, a digital camera can be attached.* The DS-Fi2-L3, a color camera head combined with a standalone control unit, enables focusing and viewing of images on the built-in 8.4-inch LCD monitor without the need for a PC. The optimum imaging conditions that match the observation technique in use can be automatically set by selecting the appropriate scene mode icon on the touch panel. Storing optimal images is easy. *With a 4x objective, the image may show uneven illumination depending on the camera used. Drawing tube Allows accurate sketching of the image being observed Plastic storage case The rugged, lightweight storage case is handy for transporting and storing the E200. Object marker Allows the point of interest within a specimen to be marked with ink ND filter for objectives (ND3) When this filter is used in combination with a 4x or 10x objective, image brightness can be adjusted to nearly equal to that of a 40x objective. 10

System diagram Digital Sight Series Camera Tubes Digital Sight Series Camera Eyepieces F CFI E 10x C-0.7x DXM Relay Lens C-mount TV Adapter A C-mount Adapter 0.55x E2-TB Binocular Tube H E2-TF Trinocular Tube H C-TE2 Ergonomic Binocular Tube H C-TEP2 DSC Port for Ergonomic Tube H CFI E 15x Y-TV TV Tube Y-TV 0.55x TV Tube A Intermediate Module Intermediate Module A A C-SHG Mercury Illuminator 50W E2-FM Epi-Fl Attachment Y-IER Eye-level Riser D B Intermediate Modules Y-THPL LED Pointer Unit A A A Y-IDT Drawing Tube Y-THS Teaching Unit B (Side-by-Side) Y-THPS Teaching Head Support Y-THF Teaching Unit (Face-to-Face)** C **Not recommended for use in conjunction with a photomicrographic system, because it makes the microscope top-heavy. D C B A E2 Simple Analyzer D C B A E2 Simple Analyzer Condensers E ND Filter for Objectives ND Filter for Objectives Blue Filter CFI60 Objectives CFI60 Objectives E2 Phase Condenser E2 Abbe Condenser E Dia. Polarizer E Dia. Polarizer Phase Contrast Slider 10x 40x Phase Contrast Slider 100x Darkfield Slider (model with field diaphragm) Both LED illumination and halogen illumination models are available. 11

Specifications Main body Optical system Illumination Eyepieces (F.O.V.) Focusing Tubes CFI60 Infinity Optical System, Parfocal distance: 60 mm High luminescent white LED illuminator (Eco-illumination) 6V20W/6V30W halogen lamp, Compliant multi-voltage (100 V-240 V) CFI E 10x (20 mm) CFI E 15x (12 mm) Coaxial coarse/fine focusing, Right: fine, Left: coarse/fine, Focusing stroke: 26.5 mm, Coarse: 37.7 mm/rotation, Fine: 0.2 mm/rotation, Coarse motion torque adjustable, Refocusing function E2-TB Binocular Tube E2-TF Trinocular Tube, Eyepiece/Port: 100/0, 0/100, 360º rotatable C-TE2 Ergonomic Binocular Tube, Inclination: 10 30 degrees, Extension: up to 40 mm Quadruple nosepiece (within main body) Rectangular stage (within main body), with specimen holder, Cross travel: 78 (X) x 54 (Y) mm Nosepieces Stages Objectives (NA / W.D., mm) CFI E Plan Achromat 4x (0.10 / 30) CFI E Plan Achromat 10x (0.25 / 7.0) CFI E Plan Achromat 40x (0.65 / 0.65) CFI E Plan Achromat 100x oil (1.25 / 0.23) Condensers Observation methods* Intermediate attachment** CFI Achromat DL and other higher-grade CFI60 objectives can be used. E2 Abbe Condenser NA 1.25, Aperture diaphragm with position guide markings for respective CFI E Plan objectives E2 Phase Condenser NA 1.25, Aperture diaphragm with position guide markings for respective CFI Achromat DL objectives Brightfield, Epi-fluorescence, Darkfield, Phase contrast, Simple polarizing E2-FM Epi-fluorescence Attachment, 2 filter cubes mountable Y-THS Teaching Unit B (Side-by-Side) Y-THF Teaching Unit (Face-to-Face) Y-IDT Drawing Tube Y-IER Eye-level Riser Power consumption (max.) Normal value: 3 W (LED model), 41 W (halogen model) Weight (approx.) 7.3 kg (Binocular standard set) *Observations except brightfield require optional accessories. **Maximum intermediate space 50 mm Dimensional diagram 206.4 101.5 Unit: mm 191.3 414.6 (When PD is 64 mm) 407.4 (Minimum microscope height) 315 411.4 (Eyepoint height when PD is 64 mm) 381.7 (When PD is 64 mm) 105 188.5 247.7 226.8 Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. December 2013 2000-13 NIKON CORPORATION WARNING TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT. Monitor images are simulated. Company names and product names appearing in this brochure are their registered trademarks or trademarks. N.B. Export of the products* in this brochure is controlled under the Japanese Foreign Exchange and Foreign Trade Law. Appropriate export procedure shall be required in case of export from Japan. *Products: Hardware and its technical information (including software) NIKON CORPORATION Shinagawa Intercity Tower C, 2-15-3, Konan, Minato-ku, Tokyo 108-6290, Japan phone: +81-3-6433-3705 fax: +81-3-6433-3785 http://www.nikon.com/instruments/ NIKON INSTRUMENTS INC. 1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A. phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A. only) fax: +1-631-547-0306 http://www.nikoninstruments.com/ NIKON INSTRUMENTS EUROPE B.V. Tripolis 100, Burgerweeshuispad 101, 1076 ER Amsterdam, The Netherlands phone: +31-20-7099-000 fax: +31-20-7099-298 http://www.nikoninstruments.eu/ NIKON INSTRUMENTS (SHANGHAI) CO., LTD. CHINA phone: +86-21-6841-2050 fax: +86-21-6841-2060 (Beijing branch) phone: +86-10-5831-2028 fax: +86-10-5831-2026 (Guangzhou branch) phone: +86-20-3882-0552 fax: +86-20-3882-0580 NIKON SINGAPORE PTE LTD SINGAPORE phone: +65-6559-3651 fax: +65-6559-3668 NIKON INSTRUMENTS KOREA CO., LTD. KOREA phone: +82-2-2186-8400 fax: +82-2-555-4415 NIKON CANADA INC. CANADA phone: +1-905-602-9676 fax: +1-905-602-9953 NIKON FRANCE S.A.S. FRANCE phone: +33-1-4516-45-16 fax: +33-1-4516-45-55 NIKON GMBH GERMANY phone: +49-211-941-42-20 fax: +49-211-941-43-22 NIKON INSTRUMENTS S.p.A. ITALY phone: +39-55-300-96-01 fax: +39-55-30-09-93 NIKON AG SWITZERLAND phone: +41-43-277-28-67 fax: +41-43-277-28-61 NIKON UK LTD. UNITED KINGDOM phone: +44-208-247-1717 fax: +44-208-541-4584 NIKON GMBH AUSTRIA AUSTRIA phone: +43-1-972-6111-00 fax: +43-1-972-6111-40 NIKON BELUX BELGIUM phone: +32-2-705-56-65 fax: +32-2-726-66-45 Printed in Japan (1312-05)T Code No. 2CE-MQZH-4 This brochure is printed on recycled paper made from 40% used material. En