Two-Tank Alarm Management



Similar documents
Level Control with DeltaV

Level control with DeltaV

PT-100 Temperature Measurement

Temperature Control of Air Heater with DeltaV

Temperature Control with DeltaV

Create!form Folder Monitor. Technical Note April 1, 2008

CREATING EXCEL PIVOT TABLES AND PIVOT CHARTS FOR LIBRARY QUESTIONNAIRE RESULTS

BackupBuddy. Installation. Page 1 of 8

Working with SQL Server Integration Services

Open a PDF document using Adobe Reader, then click on the Tools menu on the upper left hand corner.

Lesson 3 - Processing a Multi-Layer Yield History. Exercise 3-4

Intellect Platform - Tables and Templates Basic Document Management System - A101

Virtual Office Remote Installation Guide

Getting Started Guide: Transaction Download for QuickBooks 2014 Windows

Application Note. Example of user log on Magelis HMI with XB5S5B2L2 biometric switch. Advanced Technical Support - Brazil. Version: 1.

Health Science Center AirWatch Installation and Enrollment Instructions For Apple ios 8 Devices

Beckhoff TwinCAT. Configuring the TwinCAT I/O System

Introduction to Microsoft Access 2013

Appointment Scheduler

Quick Start Guide. Highly customizable automated trading Automate your trades according to rules and models you create.

Upgrading from MSDE to SQL Server 2005 Express Edition with Advanced Services SP2

This guide provides step by step instructions for using the IMF elibrary Data - My Data area. In this guide, you ll learn how to:

REMOTE DESKTOP IN WINDOWS XP

Check out our website!

Installing the Software... 1 Using the System Tray Icon... 5 Restoring the System Tray Icon... 6

Real Time Monitor. A Real-Time Windows Operator Interface. DDE Compliant. (for remote data display)

Decision Support AITS University Administration. Web Intelligence Rich Client 4.1 User Guide

C-more Remote Access, Data Log, FTP File Transfer, and Tutorial

INSTRUCTION BOOKLET. AQtivate Pro. Substation Management Software

Excel Templates. & Quote/Invoice Maker for ACT! Another efficient and affordable ACT! Add-On by V

Race 07 Car Skinning Tutorial

Using Remote Web Workplace Version 1.01

Connecting to a Soundweb TM. London Network

Instructions for Importing (migrating) Data

Maximizing the Use of Slide Masters to Make Global Changes in PowerPoint

Do-It-Yourself Templates

Introduction to Microsoft Access 2010

WebSphere Business Monitor V6.2 Business space dashboards

ICP Data Entry Module Training document. HHC Data Entry Module Training Document

Pacific Premier Bank s Business e- Banking Getting Started Guide with QuickBooks for Windows

How to Configure Windows 8.1 to run ereports on IE11

Troubleshooting steps for Oracle Financials and Markview. Jan 2015

Almyta Control System Advanced Reference Contents

SKYWARD. Data Mining. Quick Reference Guide

Check current version of Remote Desktop Connection for Mac.. Page 2. Remove Old Version Remote Desktop Connection..Page 8

OLAP Cube Manual deployment and Error resolution with limited licenses and Config keys

Microsoft Access 2010 handout

Microsoft Access Introduction

How to Add Users 1. 2.

Microsoft Outlook Setup With Exchange Server. Outlook

How to recover IE Client

Adding Links to Resources

VERIPATROL Mobile User Guide

COGNOS KARATE BELT SESSION III CREATING SLOTS

Unified Monitoring Portal Online Help Account Admin

Windows XP Chinese Character Support Installation Instruction

User Manual. Updated for igrill and ios 7

Procedure for updating Firmware of EZ4 W or ICC50 W

ATTENTION: End users should take note that Main Line Health has not verified within a Citrix

Database Program Instructions

Intellect Platform - The Workflow Engine Basic HelpDesk Troubleticket System - A102

(GXFDWLRQ Backpack Manual 2007 LearningStation. All rights reserved. 9/21/2007

Setting up a Virtual Private Network (VPN) connection Windows 8

The Dashboard. Change ActivInspire's Look And Feel. ActivInspire Primary. ActivInspire Studio. <- Primary. Studio -> page 1

TABLE OF CONTENTS SURUDESIGNER YEARBOOK TUTORIAL. IMPORTANT: How to search this Tutorial for the exact topic you need.

Microsoft Access 2007 Introduction

Version 4.1 USER S MANUAL Technical Support (800)

Virto Pivot View for Microsoft SharePoint Release User and Installation Guide

Dreamweaver and Fireworks MX Integration Brian Hogan

How to Mimic the PanelMate Readout Template with Vijeo Designer

VERIPATROL Client User Guide

Connecticut Hazardous Waste Manifests Database

2010 Outlook Web App Client Overview

Detecting and Removing Spyware From Your Home Computer

Online Bill Payment & Presentment User Guide

Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0

Moodle Administrator s Manual Table of Contents

Bulk ing With gravitymail

SFTP Server User Login Instructions. Open Internet explorer and enter the following url:

Installing Windows Server Update Services (WSUS) on Windows Server 2012 R2 Essentials

Module 2 Using the Database

AUTO ARCHIVING. December, 6 th 2005

Guide to using Cumulus software (a.k.a., the Cumulus "client")

Installing Microsoft Visual C SP1 Redistributable Package

User Guide for TASKE Desktop

Pharmacy Affairs Branch. Website Database Downloads PUBLIC ACCESS GUIDE

How to Use JCWHosting Reseller Cloud Storage Solution

An Informational User Guide for: Web Conferencing

Book Builder Training Materials Using Book Builder September 2014

Webmail Instruction Guide

BroadTouch Business Communicator/Unified Communications

Setup Guide. network support pc repairs web design graphic design Internet services spam filtering hosting sales programming

Microsoft PowerPoint 2010 Computer Jeopardy Tutorial

Updating Proximity Watch Firmware from V2.0 to v2.5 with Proximity App v2.5

emarketing Manual- Creating a New

Transcription:

Fakultet for teknologiske fag Bachelor i ingeniørfag Two-Tank Alarm Management Fakultet for teknologiske fag Adresse: Kjølnes ring 56, 3918 Porsgrunn, telefon 35 02 62 00, www.hit.no Bachelorutdanning - Masterutdanning Ph.D. utdanning

TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS... 3 1 Introduction... 4 2 Alarm management... 5 2.1 Step 1: Configure Level Alarms... 5 2.2 Step 2: Configure Level Switches... 6 2.3 Step 3: Creating an Interlock... 9 2.4 Step 4: Download... 10 3 HMI... 12 3.1 Step 1: Draw Level Switches... 12 3.2 Step 2: Animate Level Switches... 12 4 Operate... 15 3

1 Introduction 1 INTRODUCTION In this task you will learn how to program alarms, and handle alarms in HMI to the two-tank system with DeltaV. Figure 1-1 shows the two-tank system. For this task to make any sense it is important that you do the task about creating a program to the two-tank model, this task is called Two-Tank Control. Figure 1-1 The Two-tank system 4

2 Alarm management 2 ALARM MANAGEMENT In this chapter we will learn how to create alarms to the two-tank system. 2.1 Step 1: Configure Level Alarms In a lot of cases it is important and crucial with alarms. We will now configure alarms to the level of the tank. There are four capacitive level switches on the tanks that we will configure the alarms to, two on each tank. Let s start with the level to tank1 Go to Exploring DeltaV and open your area 2-TANK. Right click on the PID_LOOP_1 and open with control studio. There are already alarms inactive in the PID block, at the bottom of the window you can find them. Double click on HI_ALM and sett Limit value to 75 and press Enable, and then press ok, as shown in Figure 2-1. Figure 2-1 Alarm Properties high alarm Now double click on LO_ALM and set Limit value to 35 and press enable, and then press ok, as shown in Figure 2-2. 5

2 Alarm management Figure 2-2 Alarm Properties low alarm Now download the program by pressing the button. Press OK and yes until you can download. We now have a high and low alarm on the level of tank1. 2.2 Step 2: Configure Level Switches Now we need to apply alarms to the level switches on both the tanks. We have one capacitive level watch on high and low level. Choose 2-TANK2 and right click on IO and open it with Control Studio. Press the alarm button to add a new alarm, see Figure 2-3. 6

2 Alarm management Figure 2-3 Insert alarm Set alarm type: High High Alarm, Priority: Critical and Functional classification: Safety and press browse and choose HA1, OUT_D and press OK as shown in Figure 2-4. Figure 2-4 Alarm Properties high high alarm 7

2 Alarm management The alarm is now created, you can find it at the bottom of the page. Right click the alarm and choose rename. Rename the alarm to HA_1 like in Figure 2-5, this is the HIGH HIGH alarm for Tank1. Figure 2-5 Alarm renaming Press the alarm button to make another alarm. Another HIGH HIGH alarm for Tank2. Exactly the same procedure. Set alarm type: High High Alarm, Priority: Critical and Functional classification: Safety and press browse and choose HA2, OUT_D and press OK. Rename the alarm to HA_2 Press the alarm button to make another alarm. We will now make a Low low alarm for Tank1. Set alarm type: Low Low Alarm, Priority: Warning and Functional classification: Safety, like Figure 2-6. Check the box for inverted and press browse and choose LA1, OUT_D and press OK. Rename the alarm to LA_1 Figure 2-6 Alarm Properties low low alarm Press the alarm button to make another alarm. We will now make a Low low alarm for Tank2. Set alarm type: Low Low Alarm, Priority: Warning and Functional classification: Safety, check 8

2 Alarm management the box for inverted and press browse and choose LA2, OUT_D and press OK. Rename the alarm to LA_2 2.3 Step 3: Creating an Interlock If the level of the tank gets too high, we would like an interlock that makes sure the solenoid valves will open, and the level will decrease. Place the blocks as shown on Figure 2-7. Press OUT_D on HA1 and connect it to LV1. Do the same with HA2 and connect it to LV2 Figure 2-7 Interlock connection Mark LV1, a properties box will appear in lower left corner. Double click on MODE, that s found under Operating. Set Normal mode and Target mode to Cascade. As shown in Figure 2-8. Do exactly the same with LV2. 9

2 Alarm management Figure 2-8 MODE Properties The level switches on high level will now activate the valves. 2.4 Step 4: Download We have now created and configured alarms for all the level switches. Press Download, and choose OK and yes until you can download. Go back to Exploring DeltaV. Right click physical network and choose download physical network as shown in Figure 2-9. 10

2 Alarm management. Figure 2-9 Download Physical Network The Program is now complete. Let s head over to control studio and make some alarm functions. 11

3 HMI 3 HMI The alarms we created in our program will appear with text and sound when they are activated. We would also like some visual alarms on our four level switches that we have to create in our HMI. 3.1 Step 1: Draw Level Switches Go to Control Studio and find the picture you made for the Two-tank. In the Toolbox we can find a rectangle. Place this rectangle close to Tank1, right click on the rectangle and choose Color, and Foreground. Change color to grey. Copy the rectangle so you get four of them. Press the «A» in the toolbox and write HH in two of the rectangles and LL in the last two. Place the rectangles as shown in Figure 3-1. Figure 3-1 Alarm placement 3.2 Step 2: Animate Level Switches Double click on HH next to Tank1, Figure 3-2 will popup, check the Foreground box under Color. 12

3 HMI Figure 3-2 Foreground color Mark Exact Match, delete all the rows and make a new row with value = 1 and color = red. Like Figure 3-3 shows you. The letters HH will now be red when the high alarm is active. Figure 3-3 Foreground color assignment Press the button, Browse DeltaV Control Parameters, 2-TANK2, HA1,OUT_D, mark CV, as shown in Figure 3-4 and press OK until you are back to you picture. 13

3 HMI Figure 3-4 Browse DeltaV Control parameters Select CV The same procedure with the other level switches, but choose value = 0 on the LL alarms, and value = 1 on the HH alarms. LL TANK1=LA1 HH TANK2=HA2 LL TANK2 = LA2 Our HMI is now upgraded with visual effects when the different alarms are active. It is best to run the HMI from DeltaV Operat Run. To be able to do that, you need to save your picture under pictures. Do this go to File Save as, and save the picture in the Pic-folde with yourname1. 14

4 Operate 4 OPERATE In this chapter we will learn how to manage the alarms used in the Two-tank system. Our HMI is now ready to be run. Double click on DeltaV Operate Run located on the desktop. Press Open and choose the picture you just created, yourname1, and press enter. See Figure 4-1. Figure 4-1 Open the picture you created. On the bottom of the picture a lot of alarms will appear, most of these alarms are system alarms that we don t have to worry about. To get rid of these alarms you need to press Area Filter, like Figure 4-2. 15

4 Operate Figure 4-2 Area Filter Uncheck AREA_A like Figure 4-3 is showing. Figure 4-3 Uncheck AREA_A Now run the system in manual and make sure the alarms gets activated at their right value. The alarms will show up on the faceplate and you can press Acknowledge there, or by pressing Ack All in the lower right corner of the faceplate. See Figure 4-4. 16

4 Operate Figure 4-4 Ack All 17