NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Similar documents
Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

MNS is Switchgear System Technical Overview

The Intelligent AX1 Switchgear for Medium Voltage

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

UFES Active protection for switchgear

MEDIUM VOLTAGE SWITCHGEAR AND CONTROLGEAR MODEL MS-E. IEC /12 /15 kv 25, 31.5, 40 ka

SIVACON The Versatile Low-Voltage Switchboard

Safe and secure distribution of medium voltage with AX1

HMS Air-Insulated Medium-Voltage Metal-Clad Switchgear. Internal Arc Proof

Secondary Unit Substations

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Low Voltage Switchboards The Best Technical Solution for Your Ship

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

MEDIUM VOLTAGE SWITCHGEAR. DI-2, a modular concept combining all mediumvoltage

Unified requirements for systems with voltages above 1 kv up to 15 kv

SIVACON Low Voltage Switchboard

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Metal Enclosed Switchgears Metal Clad Switchgears Gas Insulated RMU's

FAQs-Main switchboard design criteria

Engineering Specification

Installation, Operation and Maintenance Instructions. Uniflex ABB PTMV

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

Choosing for tranquility

MEDIUM VOLTAGE SWITCHGEAR CATALOGUE. Code: P2490_xx

Medium Voltage Switchgear

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

Automation Products. Low Voltage Switchgear MNS System Overview

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

How To Choose A Transformer

TriLine ASSEMBLY System PowerModules

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

NATUS SOLUTIONS Turnkey Project Management Project Engineering and Industrial Installations. Electrotechnical Solutions at the Highest Level

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Chapter 1. Network Structures

Comparative study for cables and busbars

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

C I R E D 21 st International Conference on Electricity Distribution Frankfurt, 6-9 June 2011

The power distribution board that sets new standards

MNS Low Voltage Switchgear System Guide

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Advantages of Fixed Circuit Breaker Switchgear

Fusible Disconnect Switch

Switchgear and Metal-Enclosed Bus

The following components are common to most cubicles; this example is an ABB HK cubicle.

Nothing s BetterThan the Original MODAN Power Distribution Systems

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Switchboard system. NorLine 800

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Welcome IEEE Members and Guests Jan 20, 2014

8. Switchgear and switchgear installations for high voltage up to and including 52 kv (medium voltage)

Sample - No Commercial Use

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

CAS 36 Ring Main Unit

Technical catalogue TK 503/01 E. ZX0.2 Gas-insulated medium voltage switchgear

Medium voltage products. UniGear 500R 17.5 kv, arc-proof, air insulated switchgear for green applications

P System Cubicles. Certified for more safety

low voltage switchgear

Contents. Description. Product Selection Guide

How To Make A Power Supply From A Power Generator

The standards mentioned in this document

SWITCHBOARDS

Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical

Securing your electrical installations Prisma,

ZS1 Air-insulated medium voltage switchgear, 12 kv/17.5 kv Instruction manual BA 372/04 E

Session Four: Internal Arc Safety in New and Existing Switchgear

Modis 25/32. Modular Switchboard Solution

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

Metal-enclosed single busbar, Solid and Air-Insulated switchgear

Disconnectors and Earthing Switches 36 kv up to 800 kv

INDOOR MEDIUM VOLTAGE SWITCHGEAR UP TO 24kV

GE Power Controls. MiniFORM Switchboards

Portfolio of Solutions. High and Medium Voltage Switchgear

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

5SV Residual Current Protective Devices

Permissible ambient temperature Operation Storage, transport

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Medium Voltage technical guide. Basics for MV cubicle design

Transcription:

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements

NATUS switchgear systems your advantages minimal use of insulant volumes use of standard components with the highest quality easy operation utmost personal safety NATUS Medium Voltage Switchgears: utmost personal safety, optimal availability NATUS systems offer you high personal and operating safety, secure engineering, easy operation and high efficiency through low lifecycle costs. Take our word for it! Our engineers give you competent support and advice and see your project through from design all the way to commissioning. Application Power plants, transformer substations and distribution systems and industrial operations such as: mining industry iron and steel works automobile industry chemical works petrochemical plants paper plants cement industry waste disposal The switchgears NATUS switchgear systems are air-insulated, tested for resistance to internal arc faults and are metalenclosed with a fourfold compartment. NATUS switchgear systems are developed and manufactured in our factories in Trier and comply with the highest quality requirements. They are factory-assembled and type-tested in accordance with current standards and specifications. Upon request, we can also deliver different makes of switching devices as well as innovative technical solutions. NATUS switchgear systems stand apart because of their minimal use of insulant volumes, use of high-quality standard components, easy operation and utmost personal safety. NATUS switchgear systems have proven themselves thousandfold worldwide. The standards Construction of the switchgears as per IEC 62271-200 / VDE 0671 part 200. Tested for resistance to internal arc faults IAC AFLR as per IEC 62271-200 / VDE 0671 part 200 and IEC 60298 App. AA, criteria 1 6, earthquake testing in accordance with UBC 1997, zone 4. NATUS medium voltage switchgears are standardly performed in accordance to availability classes LSC2B as per IEC 62271-200. The partition class can either be PM or PI, depending on the design. 2

SWITCH GEARS SERVICES AUTOMATION Demanding customers across the world have put their faith in NATUS switchgear systems, and thus also in the quality and safety of our solutions. SOLUTIONS Draw out Type Medium Voltage Switchgears NES / NES-H Compact, type-tested switchgears for indoor installation in accordance with IEC 62271-200 / VDE 0671 part 200 four individually metal-clad compartments for: the main busbar, the switching device, the cable connection and low voltage devices arc safe different panel widths: 1000 mm, 800 mm, 650 mm, 500 mm pressure is released upward in all compartments optional: delivery with a tested pressure release duct High personal and operating safety all electrical and mechanical operating procedures take place when the enclosure is closed maximized operating safety owing to serial production, complete mechanical interlocking system shutters automatically protect the isolating contacts when the unit is withdrawn high availability resulting from the quick exchange of the withdrawable units by means of the universal trolley make-proof earthing switch optional: motor operated withdrawable unit and earthing switch Durable and geared for the future panels are air-insulated and use a minimum amount of insulant volumes ideal assembly is possible due to technical and economical factors assembly of state-of-the-art, low maintenance vacuum- or SF6- switching devices by renowned, leading manufacturers one can obtain spare parts easily by virtue of the use of standard insulators, standard instrument transformers, standard switching devices and standard copper sections Highest quality requirements state-of-the-art manufacturing techniques thanks to a high precision laser cutting system which guarantees perfect dimensional accuracy distortion resistant cubicle frame made of top quality galvalumed sheet steel that is bolted together internal arc resistant double sheet steel partitions between panels busbar partitioning from panel to panel electrostatic powder coating of the front door and side panels engineering and manufacturing in accordance with the quality management system EN ISO 9001 Type of protection as per IEC 60259 / VDE 0470 part 1 standard make of the enclosure: IP3XD further values upon request Operating conditions The standard make of our switchgears are designed for the following: ambient temperature: maximum temperature + 40 C 24-hour mean + 35 C minimum temperature 5 C installation altitude maximum 1000 m above sea level humidity 24-hour mean 95 % NATUS Industrial Solution Systems 3

NATUS switchgear systems safe and versatile type, arc fault and earthquake tested metal-enclosed and air-insulated draw-out type single and double busbar system Medium Voltage Switchgear NES: The switchgear for multifunctional use draw-out type switchgears for the indoor installation, type-tested, factoryassembled, air-insulated, metal-enclosed with a fourfold compartment compact panel for contactor feeder that is 500 mm wide application as a single bus system or as a duplex system optional: motor operated withdrawable units and earthing switches The following variations are possible for the conduction of hot gases that result from arc faults: - deflector plate - arc absorber - pressure release duct Technical data: NES Rated values rated voltage rated power-frequency withstand voltage rated lightning impulse withstand voltage rated busbar current rated short-time withstand current rated peak withstand current rated short-circuit duration internal arc fault test 1 s** up to 12 kv 28 kv 75 kv 2,500 A 40 ka 100 ka 3 s 40 ka L2 L3 L1 Dimensions rated branch current up to: 2,500 2,000 1,100 350 A cubicle width 1,000 800 650 500 mm cubicle depth* 1,300 1,300 1,300 1,300 mm cubicle height 2,300 up to 2,500 mm incl. control compartment H = 600 up to 800 mm * plus 92mm for front door and back wall ** tested contactor panel 40 ka / 0.1s Further values upon request 4

NATUS switchgear systems best customer services our engineers advise you competently they assist you and your project from design right through to commissioning Medium Voltage Switchgear NES-H: The high-performance switchgear that meets the highest requirements draw-out type switchgear system for the indoor installation, type-tested, factoryassembled, air-insulated, metal-enclosed with a fourfold compartment application as a single bus system or as a duplex system optional: motor operated withdrawable units and earthing switches The following variations are possible for the conduction of hot gases that result from arc faults: - deflector plate - pressure release duct Technical data: NES-H Rated values up to up to rated voltage 12 24 kv rated power-frequency withstand voltage 28 50 kv rated lightning impulse withstand voltage 75 125 kv rated busbar current 4,000 2,500 A rated short-time withstand current 50 31.5 ka rated peak withstand current 125 80 ka rated short-circuit duration 3 3 s internal arc fault test 1 s 50 31.5 ka L1 L2 L3 Dimensions rated voltage 24 12 12 12 kv rated branch current up to: (natural / air cooled) 2,000 2,900 2,500 350 A rated branch current up to: (forced ventilation) 3,800 3,300 A cubicle width** 1,000 1,000 800 2x500 mm cubicle depth* 1,700 1,700 1,700 1,700 mm cubicle height 2,300 up to 2,500 mm incl. control compartment H = 600 up to 800 mm * plus 77mm for front door and back wall ** 2x500mm = contactor panel with a maximum of 2 outgoing feeders Further values upon request NATUS Industrial Solution Systems 5

NATUS switchgear systems well proven worldwide well engineered technology high profitability low life-cycle costs Medium Voltage Switchgear NES-H18: The switchgear that meets high-current requirements draw-out type switchgear system for the indoor installation, type-tested, factoryassembled, air-insulated, metal-enclosed with a fourfold compartment circuit-breaker in truck types starting at 3.150 A application as a single bus system or as a duplex system optional: motor operated withdrawable units and earthing switches The following variations are possible for the conduction of hot gases that result from arc faults: - deflector plate - pressure release duct Technical data: NES-H18 Rated values up to up to rated voltage 12 17.5 kv rated power-frequency withstand voltage 28 38 kv rated lightning impulse withstand voltage 75 95 kv rated busbar current 4,000 4,000 A rated short-time withstand current 55 50 ka rated peak withstand current 137.5 125 ka rated short-circuit duration 3 3 s internal arc fault test 1 s 50 50 ka L1 L2 L3 Dimensions rated voltage 17.5 17.5 17.5 kv rated voltage switchgear 3,150 4,000 - A rated branch current up to: (natural- / air cooled) 3,150 3,400 2,500 A rated branch current up to: (forced ventilation) 4,000 4,200 3,300 A cubicle width 1,000 1,000 800 mm cubicle depth* 1,800 1,800 1,800 mm cubicle height 2,300 up to 2,500 mm Incl. control compartment H = 600 up to 800 mm * plus 77mm for front door and back wall Further values upon request 6

Arc-fault tested pressure release ducts fulfil the highest safety requirements The compartments in accordance with the standard availability class LSC2B A Busbar compartment The busbars are made of standard flat copper with rounded edges. The main busbars are screwed together panel-for-panel and are segregated by cast-resin bushings panel-for-panel. The electric strength of the main busbar is guaranteed without additional insulation. B Circuit breaker compartment The withdrawable units can be equipped with a diverse amount of customer specific switching devices (vacuum, SF6). The operation of the withdrawble unit can only be done behind closed doors. Mechanical interlocks prevent maloperation. When removing the withdrawable unit, all live parts are automatically protected by metal shutters. C Cable terminal compartment The generously sized cable terminal compartment is easily accessible through its explosion proof front door. The panel s entire depth can be used for the installation of instrument transformers, earthing switches, surge arresters and cable looms for single-core cables up to 5 x 500 mm 2 (NES) or 7 x 500 mm 2 (NES-H). D Low voltage compartment The low voltage compartment provides adequate space for all the necessary secondary technical components and can be delivered D A B C with the following heights: 600 mm, 700 mm, 800mm. The withdrawable unit s position switch, for example, is installed here for easy accessibility. This means that one can access it without coming in contact with the high voltage sections. The distortion resistant door is adequate for the protective relays, measuring instruments, controllers and signalling units. Pressure relief Pressure is generally released upward in our switchgear panels and not in the cable basement. We recommend that you use a pressure release duct for the targeted release in the switchgear building because of its utmost personal safety. The hot gases that result from arc faults can be conducted out of the switchgear building through the duct. Depending on the type of switchgear panel, you can alternatively use an arc absorber or a deflector plate to release the pressure. NATUS Industrial Solution Systems 7

Electrotechnical Solutions under one Roof NATUS products and services SWITCHGEARS For decades we have been setting standards in innovation, safety and quality in our core business of switchgear systems. SERVICES Our comprehensive service package leaves no wish unanswered we do everything from assembly to maintenance and a 24-hour emergency service, right through to a comprehensive spare parts service. SERVICES SWITCH GEARS AUTOMATION AUTOMATION We are constantly developing reliable solutions that are specifically tailored to customers needs in the field of automation and control systems. SOLUTIONS We combine the products of selected partners with NATUS services and a comprehensive project management to come up with professional solutions. SOLUTIONS NATUS GmbH & Co.KG Industriegelände Nord Loebstraße 12, 54292 Trier, Germany Postfach 2960, 54219 Trier, Germany Tel.: +49 (0)651-1449-0, Fax: +49 (0)651-21600 E-Mail: office@natus.de, www.natus.de