Circuit Protection. Copper Cable Limiters (600Vac) Copper/Aluminum Cable Limiters (250Vac)

Similar documents
BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

High Speed Fuses. High Speed Fuses

Alternate Methods to Short Circuit Breaker Coordination

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

Sentron Series Circuit Breakers

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

British BS 88 Fuses. Introduction

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers

LCP Coordination Panel Operations & Maintenance Manual Table of Contents

Cable Limiters. Increase System Reliability Decrease Downtime PRODUCT GUIDE

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Short Circuit Current Calculations

Packaging: MOQ: NIT, NET, TIA and TIS 20 per pack TCP and TFP 10 per pack Packaging 100% recyclable. Technical Data:

Commercial/Industrial Electricity

CHAPTER 2 EXAMPLES AND TABLES

TAP into NAU. TAP is a single tool. How it works. Transfer Academic Plan nau.edu/tap

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Photovoltaic System Overcurrent Protection

Current Limiting Protector For Systems rated kV and continuous currents through 5000A.

Mission Critical Data Center Systems

Bolted contact switches. Pringle switches

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

BB800 Off-Grid Solar System

Tmax MCCBs. Molded case circuit breakers. Tmax

Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings

Catalog January. Heavy industrial power applications Motor contactors and starters

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Motor Protection Voltage Unbalance and Single-Phasing

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Solar Circuit Protection Application Guide. Complete and reliable solar circuit protection

ICON Server box installation manual Rev. 1.1

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Solar circuit protection application guide. Complete and reliable solar circuit protection

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Tips for connecting 24-volt power

CONDUCTOR SHORT-CIRCUIT PROTECTION

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

misconceptions about arc-flash hazard assessments

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers

Distribution Dry Type Transformers

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

YSmart Technology Co.,Ltd

Data Bulletin. Circuit Breaker Characteristic Trip Curves and Coordination Class 0600 TRIP CURVES AND COORDINATION CIRCUIT BREAKER TRIP CURVES

Secondary Unit Substations

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

ALUMINUM ELECTRICAL WIRING

GE Protection and Control Business Department. Page 1 Date 5/11/99

08. SEK IDC CONNECTORS

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Westinghouse AB DE-ION Current Limiting Circuit Breakers

Overcurrent Protection

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Bypass switches. Type B-1 and type B-2. Answers for energy.

Bulletin 1489 Circuit Breakers. Selection Guide

Arc Terminator Active Arc-Resistant Switchgear

Copper wire figures. AWG Table

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Power System Selectivity: The Basics of Protective Coordination

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Cable/Conduit Conversion

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Power Supplies 3. SDN-P DIN Rail Series

Choosing the Best Solution for Reducing Arc Energy

Power Distribution Considerations for Data Center Racks

Specification Requirements DBL 700MX and 1000MX Series UPS

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

Electrical Design Training Class Ampacity WSDOT Winter 2008 BZA

Using Murrelektronik MICO Modules to Create Low Voltage Limited Energy Circuits in Industrial Control Panels according to UL508A.

UMEC International Corporation

STANDARDS AND RATINGS FOR THE APPLICATION OF MOLDED CASE, INSULATED CASE, AND POWER CIRCUIT BREAKERS

Power Quality for Information Technology System

Bill Conkling July 2012

High-Efficiency AC Power Distribution for Data Centers

Buck - Boost Transformers

Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety

Transfer switch BTPC open, closed or delayed transition

MCR1900 Media Converter 19-Slot Chassis

FORENSIC ENGINEERING ANALYSIS OF ELECTRICAL FIRES DUE TO ARCING

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

Rule Fast Track Analysis for National Life Insurance Co.

Evolve LED Area Light

ASCO SERIES 185 Power Transfer Switches

Low voltage circuit breakers. Working with trip characteristic curves

FEATURES. Catalog C-031 Rev. H

Transcription:

Catalog Number UCL (25XX 75XX) 600Vac or Less Catalog Number UCLA 250Vac or Less Catalog AC Volts Number* Rating Cable Size Cable Terminals Available UCL25XX (1) 600 250MCM T = crimp tube UCL35XX (1) 600 350MCM O = Bolt-on blade offset from center UCL50XX (1) 600 500MCM B = Bolt-on blade, centered UCL75XX (1) 600 750MCM UCLA 250 2/0 or 3/0 (2) Bolt-on blade, one end offset from center *Contact Edison Customer Satisfaction for availability, limiters not shown, latest data or information. (1) Choose terminals from "Cable Terminals Available" column to complete catalog number, EXAMPLE: "UCL-25TO" is rated for a "25" 250MCM copper cable and has a "T" tube for crimping and an "O" bolt-on blade, offset from center. Any combination of the three terminals may be selected. (2) A 4/0 aluminum cable may be used with a copper blade-to-aluminum cable connector. Benefits: Cable limiters help to a maintain electrical service by minimizing cable damage due to short circuit currents. Isolates faulted cable(s) in multiple cables per phase installations. Several cable termination types available. s: Residential: 250Vac limiters can be used to protect individual service cables tapped from a single transformer. Non-Residential: 600Vac cable limiters should be specified to protect parallel service cables in 120/208Vac, 277/480Vac etc. systems. Cable Limiter Specifications Voltage Rating: Cable Ratings: Interrupting Rating: Agency Approvals: Self-certified to UL requirements. UCL25XX 75XX, 600Vac UCLA, 250Vac 250MCM to 750MCM Cu - 600Vac 2/0 or 3/0 Cu - 250Vac 4/0 Al - 250Vac (Cu/Al terminal required) 600V - 200,000 Amps RMS 250V - 100,000 Amps RMS 49

Cable Limiters (600Vac) of Cable Limiters: By industry definition, cable limiters do not provide overload protection. Class J and Class L fuses for three or more cables-per-phase applications should be considered if overload protection is a concern. This may also be a desirable consideration for aluminum cable using suitable connectors. Cable limiters applied in utility networks and building power system main parallel service cables are primarily intended to isolate faults in multiple-cables-per-phase installations. This prevents total power outages until maintenance of faulted cable(s) can be scheduled. During the process of opening under fault conditions to isolate faulted cable(s), limiters current limiting action reduces potential for excess heat damage to unfaulted cables. Dimensions - inches Cable Limiters 250 Volts or Less AC For applications having three or more parallel cablesper-phase, cable limiters are installed at each end of each cable. For nonparallel or multiple radial cables, limiters may successfully be applied at the source end of each cable for fault isolation. When analyzing cable limiter potential applications, it is not unusual to forget that normal and abnormal current through cable limiters is divided just as it is between cables. Selectivity with upstream overcurrent protection devices is seldom of concern. When designing for cable limiter fault isolation to prevent a burn down or unscheduled blackout by one faulted cable, it is desirable to determine the continuous rating load (3 hours or more) that the remaining cables must handle without overheating. Cat. No. UCLA 50

Cable Limiters 600 Volts or Less AC Dimensions are shown in inches.* Tube-Offset Blade (TO)** Number Size* A B C D E F G H J UCL25TO 250 MCM 1-7/8 1-7/16 3/4 19/32 31/32 1-1/8 UCL35TO 350 MCM 2 3-5/8 3-3/8 1-5/8 7/8 45/64 1-1/16 1/4 UCL50TO 500 MCM 2-7/8 1-7/8 1-1/16 53/64 1-3/16 1-5/8 UCL75TO 750 MCM 3-1/2 3-3/4 3-1/2 2-1/2 1-5/16 1-1/16 1-1/2 2 Center Blade-Offset Blade (BO)** Number Size* A B C D E F G UCL25BO 250 MCM 1-7/16 31/32 1-1/8 1-1/8 UCL35BO 350 MCM 3-3/8 3-5/8 1-5/8 1-1/16 1/4 UCL50BO 500 MCM 1-7/8 1-1/2 1-5/8 1-3/16 UCL75BO 750 MCM 3-1/2 3-3/4 2-1/2 2 2 1-1/2 Tube-Tube (TT) E C D A B A Number Size* A B C D E UCL25TT 250 MCM 1-7/8 1-7/16 3/4 19/32 UCL35TT 350 MCM 2 3-5/8 1-5/8 7/8 45/64 UCL50TT 500 MCM 2-7/8 1-7/8 1-1/16 53/64 UCL75TT 750 MCM 3-1/2 2-7/8 2-1/2 1-5/16 1-1/16 *Limiter terminals are silver plated copper. **Dimensions of "TT", "OO", "TB", etc., terminals are determined by matching appropriate dimensions shown. 51

Cable Limiters (600Vac) Average Time-Current Curve Cat. No. UCL-(XXXX)-600Vac 52

Average Time-Current Curve TIME IN SECONDS 100 10 1.1 UCLC AND UCLA AMP RATING Peak Let-Through Current Curve Cat. No. UCLA and 250V INSTANTANEOUS PEAK LET-THRU CURRENTIN AMPS 100,000 80,000 60,000 40,000 30,000 20,000 8,000 6,000 4,000 3,000 A 2,000 2,000 3.000 4,000 6,000 8,000 20,000 30,000 40,000 60,000 80,000 100,000 RMS SYMMETRICAL CURRENTS IN AMPS A B=ASYMMETRICAL AVAILABLE PEAK (2.3 x SYMM RMS AMPS) B 200,000.01 10 100 RMS SYMMETRICAL CURRENT IN AMPS 53