Connector and Cable Specifications



Similar documents
Connectors and Cables

Cable Specifications and Information

Cable Pinouts. SRP I/O Module

Module Connectors and Cable Specifications

Cable Specifications and Information

Connecting the Console Port to a PC

Connector and Cable Specifications

Encore Controller to Router Connections

Cable Specifications. T3 Trunk Cabling APPENDIX

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

RS-232 COMMUNICATIONS

RJ11 RS-232 Interface

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

Making a DB to RJ45 adapter.

Cabling Guide for Console and AUX Ports

Cable Specifications

Comtrol Cable User Guide

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

SFP Transceiver Specifications

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

Cable Connection Procedures for Cisco 1900 Series Routers

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

GEU Port Gigabit Switch

Configuring the Switch with the CLI-Based Setup Program

Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products

Route Processor. Route Processor Overview CHAPTER

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

XPort Universal Demo Board User Guide

Cabling Specifications

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Power, Cable, and Antenna Connection Procedures

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Plug & Play Gigabit Ethernet Media Conversion Module. Application Note

HP ProCurve High-Speed Transceivers Installation Guide

ISHIDA BC Scale to Scale Communications

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

Connecting Serial Interface Cards to a Network

LBNP RS-232/485/422 serial device server. User manual

Cisco 1603 R Ethernet/ISDN BRI Modular Router Cable Specifications

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

DEX28-VR3P Quick Installation Guide

Serial Cables & Adapters

Using a Fabric Extender with a Cisco Nexus 5000 Series Switch

FOM-5A, 6A. Asynchronous Fiber Optic Modem

N560 series H/W Installation Guide

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

CISCO 10GBASE X2 MODULES

Contents. Section A Networking Basics Learning the Basics Section B Wired Ethernet Networking... 17

CDI-S100 SERIAL INTERFACE CARD

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Hardware Installation and Configuration Guide

HIGH QUALITY FOR DATA CENTRES ACCESSORIES AND INFRASTRUCTURE. PRODUCT CATALOG 12/2014 PRO-ZETA a.s.

AS X 48-Port 10G Top-of-Rack Switch. Installation Guide.

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

NPort DE-311 Hardware Installation Guide

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

RS-232/422/485, Power over Ethernet

HARTING mcon 1000 Introduction and features

Quick Start Guide Series 1 RU Gen 2 Data Center Switches. Arista Networks. DCS-7150S-64 PDOC

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

2100 POS System User Guide

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

2 Setting Up the Hardware for a Wired Ethernet Network Setting Up the Software for an Ethernet Network... 21

Cables and Connectors

One Port Serial Server Users Manual Model ESP901, ESP901E

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Console Cables for GarrettCom Managed Products

connecdim Gateway G1 Ethernet TCP/IP to DALI

Cisco 3200 Series Wireless And Mobile Router Ordering Brochure

RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

Table of Contents. Page Number. PLC Connections 1 Cable Solutions for Omron PLCs 11 Cable Solutions for Multi-Vendor PLCs 15

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

Long Range Ethernet Extender

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Arista 40G Cabling and Transceivers: Q&A

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.

Getting Started Guide for the Catalyst 2960-X and 2960-XR Switches

Cisco 1700 Router Overview

RouterBOARD 435G. Copyright and Warranty Information

The ABC of Direct Attach Cables

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

10/100/1000 Base-T to Gigabit Fiber Media Converter

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

10GBASE-T SFP+ Transceiver Module: Get the most out of your Cat 6a Cabling

CREATING YOUR OWN RF SWITCHING SYSTEM

Professional USB to Serial Adapter Hub with COM Retention

Transcription:

APPENDIXB This chapter describes the connector and cable specifications. Connector Specifications, page B-1l Cable and Adapter Specifications, page B-5 Connector Specifications 10/100/1000 Ports, page B-1 10-Gigabit Ethernet CX1 (SFP+ Copper) Connectors, page B-2 SFP and SFP+ Modules, page B-2 10/100/1000 Ethernet Management Port, page B-3 Console Port, page B-4 10/100/1000 Ports The 10/100/1000 Ethernet ports on switches use RJ-45 connectors and Ethernet pinouts. Figure B-1 Pin 10/100/1000 Port Pinouts Label 12345678 1 2 3 4 5 6 7 8 TP0+ TP0- TP1+ TP2+ TP2- TP1- TP3+ TP3-60915 B-1

Connector Specifications Appendix B 10-Gigabit Ethernet CX1 (SFP+ Copper) Connectors The 10-Gigabit Ethernet electrical modules use CX1 copper connectors similar to the one shown in Figure B-2. Note When ordering or using CX1 cables, ensure that the version identifier is 2 or higher. The 10-Gigabit Ethernet optical modules use the connectors shown in Figure B-3 and Figure B-4. Figure B-2 10-Gigabit Ethernet CX1 Copper Connector (example) SFP and SFP+ Modules Figure B-3, Figure B-4, and Figure B-5 show the SFP module connectors. The switch supports the SFP module patch cable, a 0.5-meter, copper, passive cable with SFP module connectors at each end (Figure B-6). This cable can be used (only with 1-Gigabit Ethernet SFP ports) to connect two Catalyst 3650 switches in a cascaded configuration. Figure B-3 Duplex LC Cable Connector 58476 278541 B-2

Appendix B Connector Specifications Figure B-4 Simplex LC Cable Connector 57834 Figure B-5 Copper SFP Module RJ-45 Connector Pin Label 12345678 1 2 3 4 5 6 7 8 TP0+ TP0- TP1+ TP2+ TP2- TP1- TP3+ TP3-60915 Figure B-6 SFP Module Patch Cable 126809 10/100/1000 Ethernet Management Port The 10/100/1000 Ethernet management port uses RJ-45 connectors with Ethernet pinouts. Figure B-7 shows the pinouts. B-3

Connector Specifications Appendix B Figure B-7 Pin 10/100 Port Pinouts Label 12345678 1 2 3 4 5 6 7 8 RD+ RD- TD+ NC NC TD- NC NC H5318 Console Port The switch has two console ports: a USB 5-pin mini-type B port on the front panel (see Figure B-8) and an RJ-45 console port on the rear panel. Figure B-8 USB Mini-Type B Port The USB console port uses a USB Type A to 5-pin mini-type B cable, shown in Figure B-9. The USB Type A-to-USB mini-type B cable is not supplied. You can order an accessory kit (part number 800-33434) that contains this cable. Figure B-9 USB Type A-to-USB 5-Pin Mini-Type B Cable 345493 345492 B-4

Appendix B Cable and Adapter Specifications The RJ-45 console port uses an 8-pin RJ-45 connector (See Table B-2 and Table B-3.) The supplied RJ-45-to-DB-9 adapter cable is used to connect the console port of the switch to a console PC. You need to provide a RJ-45-to-DB-25 female DTE adapter if you want to connect the switch console port to a terminal. You can order a kit (part number ACS-DSBUASYN=) containing that adapter. For console port and adapter pinout information, see Table B-2 and Table B-3. Cable and Adapter Specifications StackWise Cables, page B-5 StackWise Adapters, page B-6 StackWise Adapter Blanks, page B-7 SFP and SFP+ Module Cable Specifications, page B-8 Four Twisted-Pair Cable Pinouts, page B-8 Two Twisted-Pair Cable Pinouts, page B-9 Identifying a Crossover Cable, page B-9 Console Port Adapter Pinouts, page B-9 StackWise Cables Figure B-10 shows a StackWise stacking cable. Figure B-10 StackWise Stacking Cable 347676 B-5

Cable and Adapter Specifications Appendix B You can order these StackWise cables (nonhalogen) from your Cisco sales representative: STACK-T2-50CM= (0.5-meter cable) STACK-T2-1M= (1-meter cable) STACK-T2-3M= (3-meter cable) StackWise Cables Minimum Bend Radius and Coiled Diameter Table B-1 specifies the minimum bend radius and coiled diameter for each StackWise cable. Table B-1 StackWise Cables Minimum Bend Radius and Coiled Diameter Cable Part Number Cable Length Minimum Bend Radius Minimum Coiled Diameter STACK-T2-50CM 1.64 ft (0.5 m) 2.60 in. (66 mm) 5.20 in. (132 mm) STACK-T2-1M 3.28 ft (1.0 m) 2.60 in. (66 mm) 5.20 in. (132 mm) STACK-T2-3M 9.84 ft (3.0 m) 3.58 in. (91 mm) 7.17 in. (182 mm) StackWise Adapters A StackWise adapter must be installed in the stacking port to enable stacking. The StackWise cable connects to the StackWise adapter in the stacking port. For switches ordered with stacking, the StackWise adapters are preinstalled. If the switches are not ordered with stacking, the adapters must be ordered separately and installed. You can order a StackWise adapter as part of a StackWise stacking upgrade kit (part number C3650-STACK-KIT=), that contains two adapters and a 0.5 m StackWise cable.. B-6

Appendix B Cable and Adapter Specifications Locating the StackWise Adapter Serial Number If you contact Cisco Technical Assistance regarding a StackWise adapter, you need to know the serial number. See Figure B-11 to find the serial number. Figure B-11 Location of the Serial Number on the StackWise Adapter 347806, 781-00796-01 SN: AAANNNNXXXX StackWise Adapter Blanks A StackWise adapter blank is installed in the stacking port if stacking is not specified at the time of ordering the switch. The StackWise adapter blank is screwed into the stacking port and must be removed and replaced by a StackWise adapter if the port is to be used for stacking. Figure B-12 shows a StackWise adapter blank. Figure B-12 StackWise Adapter Blank 1 2 3 347816 1 StackWise adapter blank 3 Cisco label 2 Assembly screw B-7

Cable and Adapter Specifications Appendix B SFP and SFP+ Module Cable Specifications Each port must match the wave-length specifications on each end of the cable, and the cable must not exceed the stipulated cable length. Copper 1000BASE-T SFP module transceivers use standard four twisted-pair, Category 5 cable at lengths up to 328 feet (100 meters). For cabling specifications, refer to the Cisco Transceiver Modules data sheet at: http://www.cisco.com/en/us/products/hw/modules/ps5455/products_data_sheets_list.html Four Twisted-Pair Cable Pinouts Figure B-13 1 TPO+ 2 TPO- 3 TP1+ 6 TP1- Four Twisted-Pair Straight-Through Cable Schematic Router or PC 1 TP1+ 2 TP1-3 TPO+ 6 TPO- 4 TP2+ 5 TP2-7 TP3+ 8 TP3-4 TP3+ 5 TP3-7 TP2+ 8 TP2-65272 Figure B-14 1 TP0+ 2 TP0-3 TP1+ 6 TP1- Four Twisted-Pair Crossover Cable Schematic 1 TP0+ 2 TP0-3 TP1+ 6 TP1-4 TP2+ 5 TP2-7 TP3+ 8 TP3-4 TP2+ 5 TP2-7 TP3+ 8 TP3-65274 B-8

Appendix B Cable and Adapter Specifications Two Twisted-Pair Cable Pinouts Figure B-15 3 TD+ 6 TD Two Twisted-Pair Straight-Through Cable Schematic Router or PC 3 RD+ 6 RD 1 RD+ 2 RD 1 TD+ 2 TD H5578 Figure B-16 3 TD+ 6 TD Two Twisted-Pair Crossover Cable Schematic 3 TD+ 6 TD 1 RD+ 2 RD 1 RD+ 2 RD H5579 Identifying a Crossover Cable To identify a crossover cable, hold the cable ends side-by-side, with the tab at the back. The wire connected to the pin on the outside of the left plug should be the same color as the wire connected to the pin on the outside of the right plug. (See Figure B-17.) Figure B-17 Identifying a Crossover Cable Pin 1 on one connector and pin 8 on the other connector should be the same color. Pin 1 Pin 8 H10632 Console Port Adapter Pinouts The console port uses an 8-pin RJ-45 connector, which is described in Table B-2 and Table B-3. If you did not order a console cable, you need to provide an RJ-45-to-DB-9 adapter cable to connect the switch console port to a PC console port. You need to provide an RF-45-to-DB-25 female DTE adapter if you B-9

Cable and Adapter Specifications Appendix B want to connect the switch console port to a terminal. You can order a kit with an adapter (part number ACS-DSBUASYN=). For console port and adapter pinout information, see Table B-2 and Table B-3. Table B-2 lists the pinouts for the console port, the RF-45-to-DB-9 adapter cable, and the console device. Table B-2 Console Port Signaling Using a DB-9 Adapter Console Port (DTE) RJ-45-to-DB-9 Terminal Adapter Console Device Signal DB-9 Pin Signal RTS 8 CTS DTR 6 DSR TxD 2 RxD GND 5 GND GND 5 GND RxD 3 TxD DSR 4 DTR CTS 7 RTS Table B-3 lists the pinouts for the console port, RJ-45-to-DB-25 female DTE adapter, and the console device. Note The RJ-45-to-DB-25 female DTE adapter is not supplied with the switch. You can order a kit with the adapter (part number ACS-DSBUASYN=) from Cisco. Table B-3 Console Port Signaling Using a DB-25 Adapter Console Port (DTE) RJ-45-to-DB-25 Terminal Adapter Console Device Signal DB-25 Pin Signal RTS 5 CTS DTR 6 DSR TxD 3 RxD GND 7 GND GND 7 GND RxD 2 TxD DSR 20 DTR CTS 4 RTS B-10