Modbus Plus Adapter. EIG Model MP1, a Modbus Plus adapter for DMMS 300+ and Futura+ Monitors. User Manual and Reference Guide Version 1.



Similar documents
ASCENT TM Integrated Shipment Management

SM Interface modules

SM Series 3300 W DC POWER SUP PLIES

User Manual IC-485AI

Restoration Certificate No

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

ES Series 150 W DC POWER SUP PLIES

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

SM Se ries 6000 W DC POWER SUP PLIES DELTA ELEKTRONIKA B.V. Mod els Volt age range Cur rent range. Three phase input

TX2123 RS485 TO ETHERNET ADAPTOR

Appendix D: Guidelines for Collaborative Study Procedures To Validate Characteristics of a Method of Anal y sis

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

Modbus Server SAMSUNG Air Conditioners

User Manual. Humidity-Temperature Chart Recorder. Model RH520

INTRODUCTION FEATURES OF THE ICM

Table of Contents. Creating a VC1000 Network... 3

F2400 FOM II Series Fiber Optic Modem Technical Manual

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IntesisBox Modbus Server Fidelio IP

Keep it Simple Timing

LSNJ...justice for all

APPLICATION. Using the PB-100 to Make Calls and Announcements From a Database. Using the PB-100 for All-Call Dialing

Power Meter Series 700

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

IntesisBox Modbus Server SAMSUNG Air Conditioners

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

The Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual

Universal Serial Bus (USB) to DH-485 Interface Converter

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

New MINIMAG Magnetic Stripe Reader

Energy Communication Unit (ECU)

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface

M1000 Process Alarm Monitor

IntesisBox KNX Modbus RTU master

(12) Patent Application Publication (10) Pub. No.: US 2003/ A1 Wu et al. (43) Pub. Date: Feb. 20, 2003

Modbus RTU (RS-485) TCP/IP (Ethernet)

User's Guide. Integrating Sound Level Datalogger. Model Introduction

IntesisBox KNX Modbus TCP master

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

IRS-8B. In stal la tion and Pro gram ming Man ual. Soft ware Ver Man ual N Rev. -

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

KNX Panasonic Air Conditioners

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Mass Me dia Ex po sure among Ur ban Youth in Ne pal

Installation Guide Solar Connect-11

Nikon Capture 4 CMS The Color Management Tab (Windows) Change Display Profi le Advanced Add

CONSOLE REMOTE I /O AC 9V

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Real Life Online Seminars. HEART of Accounting. The. John W. Day, MBA. A 4-hour course for non-accountants!

Liebert IntelliSlot Web Cards

WEB log. Device connection plans

VOICE RECORDING SYSTEM ISDN PRI / BRI

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Communicate and view data from meters with one simple device

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox Modbus Server - Mitsubishi Electric G50

DMX USB PRO. User Manual.

Driver Pant 8 and antenna switcher Ant 8. User manual

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

USB Port Extender Kit

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Energy Communication Unit (ECU)

EDI Distributor Control Interface Wiring and Setup Instructions

Temperature & Humidity SMS Alert Controller

Video Splitter VS-104 / VS-108 User's Manual

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

with Electronic Assistant

Temperature & Humidity SMS Alert Controller

Installation Instructions For Controllers with MS/TP Automatic MAC Addressing. Patent Pending

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

Bluetooth to serial HC-06 wireless module

Modbus Communications for PanelView Terminals

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Technical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

MDI/MDIX) FEP-32008T-3

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Link Link sys E3000 sys RE1000

Testing PCI/ISA & PCMCIA Serial Cards

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Getting Started. Linksys RE1000 Wireless-N Extender

MULTILINK 8 IN PUTS 8 OUTPUTS INTERFACE/PERIPHERAL ML-8

PNSPO! Modbus Solution CP1H / CP1L / CJ1 / CJ2 / CS1. Version /18/2009

Transcription:

Modbus Plus Adapter EIG Model MP1, a Modbus Plus adapter for DMMS 300+ and Futura+ Monitors User Manual and Reference Guide Version 1.6

Modbus Plus Adapter User Manual and Reference Guide Version 1.6 Pub lished by: Elec tro In dus tries/gaugetech 1800 Shames Drive West bury, NY 11590 All rights re served. No part of this pub li ca tion may be re pro duced or trans mit ted in any form or by any means, electronic or me chani cal, in clud ing pho to copy ing, re cord ing, or in for ma tion stor age or re trieval sys tems or any fu ture forms of du pli - ca tion, for any pur pose other than the pur chas er s use, with out the ex pressed writ ten per mis sion of Elec tro Industries/GaugeTech. 1998 Elec tro In dus tries/gaugetech Released November 1998 Printed in the United States of America Modbus and Modbus Plus are registered trademarks of Schneider Automation, Inc.

Cus tomer Serv ice and Sup port Cus tomer sup port is avail able 9:00 a.m. to 4:30 p.m., east ern stan dard time, Mon day through Fri day. Please have the model, se rial number and a de tailed prob lem de scrip tion avail able. If the prob lem con cerns a par ticu lar read ing, please have all me ter read ings avail - able. When re turn ing any mer chan dise to EIG, a re turn authori za tion number is re quired. For cus tomer or tech ni cal as sis tance, re pair or cali bra tion, phone 516-334-0870 or fax 516-338-4741. Prod uct Warranty Elec tro In dus tries/gaugetech war rants all prod ucts to be free of de fects in ma te rial and work man ship for one year from the date of ship ment. Dur ing the war ranty pe riod, we will, at our op tion, re pair or re place any prod uct that proves to be de fec tive. To ex er cise this war ranty, fax or call our customer- service de part ment. You will re ceive prompt as sis tance. Send the in stru ment, trans por ta tion pre paid, to Elec tro In dus tries/ GaugeTech at 1800 Shames Drive, West bury, NY 11590. Re pairs will be made and the instrument will be re turned. Limitation of Warranty This war ranty does not ap ply to de fects re sult ing from un au thor ized modi fi ca tion, mis use, or use for any rea son other than elec tri cal power moni tor ing. OUR PRODUCTS ARE NOT TO BE USED FOR PRIMARY OVER-CURRENT PRO- TECTION. ANY PROTECTION FEATURES IN OUR PRODUCTS ARE TO BE USED FOR ALARM OR SECONDARY PROTECTION ONLY. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ELECTRO INDUSTRIES/GAUGETECH SHALL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING FROM ANY AUTHORIZED OR UNAUTHORIZED USE OF ANY ELECTRO INDUSTRIES/GAUGETECH PRODUCT. LIABILITY SHALL BE LIMITED TO THE ORIGINAL COST OF THE PRODUCT. State ment of Cali bration Our in stru ments are in spected and tested in ac cor dance with speci fi ca tions pub lished by Electro In dus tries/gaugetech. The ac cu racy and cali bra tion of our in stru ments are trace able to the Na tional Bu reau of Stan dards through equip ment that is cali brated at planned in ter vals by com pari son to cer ti fied stan dards. Disclaimer The in for ma tion pre sented in this pub li ca tion has been care fully checked for re li abil ity; how - ever, no re spon si bil ity is as sumed for in ac cu ra cies. The in for ma tion con tained in this docu - ment is sub ject to change with out no tice. Elec tro In dus tries/gaugetech i.

ii. Elec tro In dus tries/gaugetech

Electro Industries/ GaugeTech Elec tro In dus tries/gaugetech was founded in 1973 by en gi neer and in ven tor Sam uel Ka gan. Dr. Ka gan s first in no va tion, which revo lu tion ized the power- monitoring field, was the de vel op ment of an af ford able, easy- to- use AC power me ter. In the 1980s, Dr. Ka gan and his team at EIG de vel oped a digi tal mul ti func tion moni tor. This moni tor, with its abil ity to meas ure every as pect of power, trans formed AC power me ter ing and power dis tri bu tion. Un der Dr. Ka gan s lead er ship, EIG again de vel oped a prod uct that sur passed everything else on the mar ket: the Fu tura+ de vice. It sup plied all the func tion al ity of a fault re corder, an event re corder and a data log ger in the con figu ra tion of a sin gle me ter. To day, as a leader in the de vel op ment and pro duc tion of power- monitoring prod ucts, EIG aspires to at tain zero- defect manu fac tur ing. Elec tro In dus tries/gaugetech iii.

Products All of EIG s prod ucts are de signed, manu fac tured, tested and cali brated at our fa cil ity in West bury, New York. EIG manu fac tures the most so phis ti cated digi tal power moni tors avail able. Our prod ucts han dle such things as: Mul ti func tion power moni tor ing Power- quality moni tor ing On board data log ging for trending power usage and quality Dis tur bance analy sis EIG manu fac tures both sin gle and mul ti func tion digi tal power moni tors. These utility- grade de vices are highly re li able and so phis ti cated. Futura+ Se ries As the ul ti mate power- quality moni tor, the Fu tura+ is widely used at auto mated sub sta tions. In addition to having nearly all of the capabilities of DM meters, it also handles: Power- quality moni tor ing High- accuracy AC me ter ing On board data log ging On board fault and voltage re cord ing Ten channels of analog outputs DM Se ries DM meters are the sub sta tion stan dard for many utili ties and large in dus tri al companies. These three-phase multifunction monitors meas ure every as pect of power. Watt age, voltage, amperage, var, VA, power factor, frequency and harmonics (%THD) P rotocols: Mod bus, Modbus Plus, DNP 3.0 and Ethernet A na log outputs (0-1 and 4-20mA) iv. Elec tro In dus tries/gaugetech

Single- Function Me ters AC volt age and am per age DC volt age and am per age AC watt age Single- phase moni tor ing with maxi mum and mini mum de mands Trans ducer read outs Portable Analyzers Power-quality analysis Energy analysis Elec tro In dus tries/gaugetech v.

vi. Elec tro In dus tries/gaugetech

Table of Contents Overview Introduction............................. 1 Installation.............................. 2 MP1 Installation......................... 2 Meter Installation........................ 2 Operation Operating Modes........................... 3 Normal Mode.......................... 3 Program Mode.......................... 3 Programming the MP1......................... 4 Program-Mode Commands....................... 5 Baud Rate........................... 5 Boot Software Version....................... 5 Echo.............................. 5 Global Registers......................... 6 Meter Address.......................... 6 Product Code.......................... 7 Resetting the MP1........................ 7 Appendices Appendix 1: Command Summary.................... 8 Appendix 2: Specifications....................... 10 Appendix 3: Mounting Information.................... 11 Appendix 4: Programming Connections.................. 12 Appendix 5: Standard Connections.................... 13 Elec tro In dus tries/gaugetech vii.

viii. Elec tro In dus tries/gaugetech

Overview Introduction The Modbus Plus Adapter (MP1) is handy gadget that allows a Futura+ or DMMS 300+ monitor to communicate over a Modbus Plus network. The monitor becomes just another node on the network: It can take full advantage of the speed of the Modbus Plus architecture. A monitor equipped with an MP1 can be polled by other nodes on the same network, or by nodes on adjacent bridged networks. The MP1 can be configured to globally broadcast any 32 registers of information. This rugged device is opto isolated and features an upgradable flash RAM. Use the MP1 to: Con vert Mod bus to Mod bus Plus. Poll me ters for Mod bus Plus global vari ables and pres ent them to a Mod bus Plus network. Program: The meter address. The meter baud rate. The global variables to poll. Read the meter s Modbus Plus address (which is set with its top switches). To program the MP1, all you need is the MP Cable and an RS485 two-wire terminal interface operating at 19.2 kilobaud. Just connect the MP1 between the monitor and the network, and you re off and running. Elec tro In dus tries/gaugetech 1.

Installation The Modbus Plus Adapter supports a single meter in register polling and global variables. Use a terminal interface to program the global variables, meter address and baud rate. MP1 Installation Set the MP1 s address to 1 (1,0). Slide the MP1 s PROG/NORM switch to NORM. Plug the 5-pin meter connector cable (MP Cable) into both the meter and the MP1. Attach the DB9-female connector to the Modbus Plus network. Meter Installation Most meters can be used right out of the box, because the required settings are the default values. If necessary: Set the meter address to 1. Set the baud rate to 9600. Set the protocol to Modbus RTU. 2. Elec tro In dus tries/gaugetech

Operation Operating Modes Normal Mode In Normal mode, the MP1 transfers data between its meter side and its Modbus Plus side. No commands can be executed in Normal mode. Program Mode Program mode is used with a computer to read, set and erase parameters, or check the MP1 s status or boot software version. The functions available in this mode are described below. (See Appendix 1: Command Summary.) In Program mode, you can read, program or erase: The meter s baud rate. The meter s address. The global registers. In Program mode, you can read: The MP1 s product code. The boot software version. Elec tro In dus tries/gaugetech 3.

Programming the MP1 To program the MP1: Use the MP Cable to connect the computer s RS232 port to the Modbus Plus Adapter, via a Unicom 2500 (or another RS485-to-RS232 converter). Set the DCE/DTE switch on the Unicom 2500 (or equivalent) to DCE. Turn the RS232 BAUD dial on the MP1 (or Unicom) to 19.2. Connect the 2-wire RS485 cable from the MP1 (or Unicom) and external power to the 5-wire connector (MP Cable) on the Modbus Plus Adapter, as shown in Appendix 4: Programming Connections. Set the baud rate in the terminal program to 19.2 kilobaud. To enter Program mode: Slide the NORM/PROG switch to PROG. Unplug the 9V AC adapter and wait five seconds. Plug in the 9V AC adapter. Use Windows 95 HyperTerminal or another communications program to select local mode and a baud rate of 19.2 kilobaud. Once you ve finished programming, to reenter Normal mode: Slide the NORM/PROG switch to NORM. Replace the MP Cable (see Appendix 4: Programming Connections) with the 5-wire cable (see Appendix 5: Standard Connections). 4. Elec tro In dus tries/gaugetech

Program-Mode Commands Baud Rate Use the following commands to read, program or erase the baud rate in the meter s flash. Erase Baud Rate Type: BE[Enter] B0 will be returned, indicating that the baud rate has been erased. Program Baud Rate Type: BPrate[Enter], where rate is the baud rate (of up to five digits). B0<CR> will be returned, indicating that the baud rate has been programmed. Read Baud Rate Type: BR[Enter] BRrate<CR> will be returned if a baud rate is in the flash, where rate is the baud rate (of up to five digits). NA<CR> will be returned if the flash was not programmed with a baud rate. Boot Software Version Type: Q[Enter] Qn<CR> will be returned, where n is the three-digit version number of the boot software. Echo The echo command is used to determine whether the Modbus Plus Adapter is responding correctly. Type: A[Enter] A<CR> will be returned if the Modbus Plus Adapter is responding correctly. Elec tro In dus tries/gaugetech 5.

Global Registers Use the following commands to read, program or erase the global registers in the meter s flash. Erase Global Registers Type: GE[Enter] G0<CR> will be returned, indicating that the data has been erased. Program Global Registers Type: GP02data[Enter], where data is a maximum of 162 characters, delimited by commas in groups of four. For example: GP02,1111,2222[Enter]. G0<CR> will be returned, indicating that the data has been programmed. Read Global Registers Type: GR[Enter] GRrate<CR>data<CR> will be returned if flash has been programmed with global registers, where rate is the baud rate and data is the programmed data, delimited by commas in groups of four. For example: GR02<CR>1111,2222<CR>. NA<CR> will be returned if the flash was not programmed with data. Meter Address Use the following commands to read, program or erase the meter address in the meter s flash. Erase Meter Address Type: ME[Enter] M0<CR> will be returned, indicating that the meter address has been erased. Program Meter Address Type: MPaddress[Enter], where address is a maximum of three digits. M0<CR> will be returned, indicating that the meter address has been programmed. 6. Elec tro In dus tries/gaugetech

Read Meter Address Type: MR[Enter] MRaddress<CR>will be returned if a meter address is in the flash, where address is the meter address (of up to three digits). NA<CR> will be returned if the flash was not programmed with a meter address. Product Code This command returns the product code assigned to the Modbus Plus Adapter. Type: E[Enter] Product code<cr> will be returned, where product code is the Modbus Plus Adapter s product code, Modbus Plus Adapter. Resetting the MP1 The Modbus Plus Adapter will automatically reset after five to ten minutes if no serial interrupt has occurred. To manually reset the MP1: Type: K[Enter] K<CR> will be returned, indicating that the Modbus Plus Adapter has been reset. Elec tro In dus tries/gaugetech 7.

8. Elec tro In dus tries/gaugetech

Appendix 1: Command Summary Description Input Output Baud BE[Enter] B0<CR> Rate: verifies that the baud rate has Erase been erased Baud BPrate[Enter] B0<CR> Rate: rate= the baud rate verifies that the baud rate has Program (of up to five digits) been programmed Baud BR[Enter] BRrate<CR> Rate: rate=the programmed baud rate Read (of up to five digits) NA<CR> indicates no baud rate was programmed Boot Q[Enter] Qn<CR> Software n=the three-digit version number Version of the MP1 s boot software Echo A[Enter] A<CR> verifies that the MP1 is responding properly Global GE[Enter] G0<CR> Registers: verifies that the data has been erased Erase Global GP02data[Enter] G0<CR> Registers: data=up to 162 verifies that the data has been Program characters of data programmed Global GR[Enter] GRrate<CR>data<CR> Registers: rate=the programmed baud rate Read data=the programmed data NA<CR> indicates no data was programmed Elec tro In dus tries/gaugetech 9.

Description Input Output Meter ME[Enter] M0<CR> Address: verifies that the meter address has Erase been erased Meter MPaddress[Enter] M0<CR> Address: address=meter address verifies that the meter address has Program (of up to three digits) been programmed Meter MR[Enter] MR[address]<CR> Address: address=the programmed meter address Read (of up to three digits) NA<CR> indicates no meter address was programmed Product E[Enter] product code<cr> Code: product code=the MP1 s factory- Read assigned product code Reset K[Enter] K<CR> verifies that the MP1 has been reset 10. Elec tro In dus tries/gaugetech

Appendix 2: Specifications Power Voltage Requirements Maximum Power Consumption Isolation Voltage Input Data Rate LED Indicators Switches Ports and Connectors Enclosure Dimensions Mounting Operating Temperature None (supplied by meter) 3VA 2500V RMS (RS485 to Modbus Plus) 300-57,600 baud POWER ERR (error) TX (transmit) CNTRL (control) RX (receive) ACTIVE (Modbus Plus) Modbus Plus Address (two dials) PROG/NORM (program/normal selection) Modbus Plus (DB9 female) Power (RS485, 2-wire detachable terminal block) Rugged aluminum, resistant to electromagnetic interference Length: 6 13 16 (169mm) Width: 4 5 8 (117mm) Height: 1 (27mm) Stand alone or wall mount (mounting plate supplied) 20 to +70 C Elec tro In dus tries/gaugetech 11.

Appendix 3: Mounting Information 12. Elec tro In dus tries/gaugetech

Appendix 4: Programming Connections MP1 Modbus Plus Adapter 9V AC RS485- to-rs232 Converter Power 9V AC DCE DB9 male serial cable DTE DB9 female 9V AC Computer MP Cables Elec tro In dus tries/gaugetech 13.

Appendix 5: Standard Connections To Modbus Plus Network MP1 Modbus Plus Adapter 5-Wire Connection (end view of MP1 and monitor) 1 5 1 2 3 4 5 5-Wire Cable 1 5 Modbus Plus Interface Futura+ or DMMS 300+ 14. Elec tro In dus tries/gaugetech

Elec tro In dus tries/gaugetech 15.