Software ECN # Change/Update Description Version 5.0.0.1 9/29/2008 - Continuation from 4.0.1.8 (XP) version - Added 1914 (14 zone) model - Overview screen resolution changed to 1024 by 768 - Updated SECS/GEM capability - Added Lot tracking via SECS/GEM feature - Added Monitoring temperature feature using 2nd HC2 controller (serial communication to main HC2 ctrl). Monitoring HC2 driver version 9.0.0.0. - Added feature for Blower RPM data read via SECS/GEM - Added Belt speed range auto switch digital output option - Added Custom digital switch option - Removed default labels from I/O selection; only I/O numbers are displayed 5.0.0.2 10/6/2008 - Added HellerSECSGEM version 1.0.10.0 compatibility - VID 30554 is usdated using UpdateU1VID, it was I4 type earlier 5.0.0.3 12/10/2008 Not released - Recipe shadowing to allow recipe upload/download/delete when it is running (Heller SECSGEM) - Update setup wizard XML file to add channel table. - Update HC2 drivers to allow Offset entry program to work on newer build HC2 (with rev2 of Cirrus logic processor) 5.0.0.4 Rev-A ECN080069-000 12-29-2008 - Fixed a crash with Edit mode - Update HC2 drivers to allow voltage style inputs on TDM for belt - Fixed a rare issue related to TDM channel type read. This is related to K-type or voltage style i/p. J-type T/C was never implemented. - Coupter control rail fix for 3 rail 2 conveyor belt configuration. 5.0.0.5 Jan-20-2009 - Added Smema9851 interface option which addresses smema upstream signal. Upstream stays ready when product entering the oven until board length + board spacing is achieved, then signal goes to not-ready for 0.5sec and comes back to ready state to accept next board. 5.0.0.6 Feb-04-2009 - Fixed an issue where Smema(II or 9851) options were not getting set to the HC2 controller. This issue was noticed on a Vista OS and 5.0.0.5 version. - Fixed a rare issue where hot job was not getting loaded from a cooldown mode. As soon as recipe loaded oven was going into cooldown.
5.0.0.7 Mar-16-2009 - Added Smema with Belt Stop option (Cure Oven SMEMA) - When Belt SP=0, light tower stays Yellow 5.0.0.8 Mar-25-2009 - Fixed issues noticed related to board spacing and SMEMA9851 with belt stop 5.0.0.9 Apr-15-2009 - Added settable belt stop delay for cure oven smema - Added option: new board delay for SMEMA 9851 - Added option: Entrance board Jam/Stop warning using predefined board length - Added option to disable board length from board drop calculation 5.0.0.10 Apr-24-2009 - Fixed an issue noticed on 5.0.0.9 for board drop not working under certain condition (while board is entering if exit sensor is blocked). - Board entrance and exit Stop are made independent of animation /brd count when predefined board length is selected. - Heat channel PB=15 as a new default value; old value was 25. - Added a function for KIC to check if oven is in Remote or Local control. 6.0.0.0 June-12-2009 - Continuation from 5.0.0.10 - Fixed: in 5.0.0.10 if SMEMA9851 is enabled without board animation, then entrance and exit part of smema did not work. - Oven Barcode Program compatibility - VIP mode option for Samsung. Create vip or vip.txt file in c:\oven folder and then run oven program to activate VIP mode - Feature added: Auto log down to operator level - Feature added: Auto acknowledge warning when click OK on pop up message 6.0.0.1 July-13-2009 - Bug fixed: auto log down to operate mode: once log down to operate mode, SP can still be changed - Bug fixed: - autopurge/standby option did not worked for closed loop Dansensor control. High flow o/p stayed on even after purge timeout. Without closed loop, once low flow is active, purge is not activated by sensor input. Note: For Autopurge/standby option, all entrance sensor inputs are always active even board/smema opotiona are not selected. - Bug fixed: 1913 model with cool zone1 heater setup, cool zone PV was grayed out. 1914 model: zone 14 PV were grayed out.
6.0.0.2 Sep-18-2009 - DY sensor capability - Hyperterminal read for Hygrometer - When program starts, allow time for HC2 to boot completely before generating communication error - Added SECSGEM events 1076-1083 for board entry and exit - Added feature to allow custome bitmap for N2 on/off and CBS up/down buttons. (N2ON.bmp, N2OFF.bmp, CBSUP.bmp, CBSDOWN.bmp). - Startup sequence delay for "Audible alarm on all warning" option is removed. 6.0.0.3 ECN 090037-000 Nov-19-2009 - When "Disable autoacknowledge warnings" selected, autoacknowledge warnings for heat-belt warning untill startup sequence is finished +2min. - Audible alarm on all warnings is not active during startup sequence +2min. - Bug fix: Calender issue with Japanese language - Bug fix: Unstable belt speed when exit sensor is blocked - HC2 driver version check during program start is updated to check for exact match. Previous versions were checking only for older version. 6.0.0.4 12-10-2009 - SMEMA operation tie-up with barcode program - improved barcode-smema operation on dual lane smema - Fixed: N2 button bitmap with password protection was not representing actual N2 on/off when clicked Cancel on password window. - Recipe name in Winkic when cooldown is loaded displays COOLDOWN now. 6.0.0.5 Jan-28-2010 - Added Features: - Blower RPM display on overview screen (Heat and cool zones) - Data logging for blower RPM - Message/Warning/Alarm for heat zones based on blower RPM - Added fix for ActiveX function calls (KIC, ECD). Issue was that user thread can request data before communication thread populates buffer data. - Fixed: single channel Dansensor communication message was not regenerating after acknowledged in alarm window. 6.0.0.5 patch Jan-28-2010 - Improved HC2 comm loss error mechanism. Allow 15sec to recover communication, (changed from 5sec). 6.0.0.6 Mar-08-2010 - ActiveX function change for rail width change (for Mydata Line Control software).
6.0.0.7 Mar-26-2010 - Fixed: 1914 R-L model overview layout - Fixed: 1913 R-L with visible flux heater overview layout - Fixed: 1913 with non-visible flux heater chanel issue. Flux1 heater channel was hidden under top13 zone. 6.0.0.8 May-05-2010 Touch screen optimized version 6.0.0.9 May-21-2010 - Add Top and Bottom temperature zones graph view - Separate digital output for Audible Warning conditions - Production capacity display feature added - HC2 global high process alarm max limit changed from 650C to 1000C. - SECSGEM VID 1011, 1013 generated to match with manual. -1 is added for unused/disabled channels, same as VID1010. - ActiveX notification event correction for events 20,21,60,61 6.0.0.10 June-16-2010 - Added intelligent exhaust option - Added standby blower speed option - New ActiveX function to read Flux heater channel SP & PV 6.0.0.11 Aug-10-2010 - Predefined board animation length (CO60122) - Added "STANDBY MODE" label on overview when blower standby mode is active - ActiveX event 61 (board exit) correction - Setup wizard: allow independent sensor distance for Lane 1 and 2. - Data logging in decimal for PV and OP% - Fixed: CBS up/down button display when set to Classic mode - Fixed: CC Rail Jog mode overview display - Fixed: Red light and audible warning on board drop/stop option 6.0.0.12 Sep-13-2010 - Added idle mode energy saving feature; a standby recipe or cooldown mode can be loaded when no boards in oven for set time.
6.0.0.13 Nov-01-2010 - Fixed an issue where oven was not controlling to SP when recipe is loaded after autoclean job or by barcode program - Added option: Custom Warning/Alarm 3 - Added option: Board warning digital output per lane - Special (SEC) light tower on-off control - Added new event to log recipe name after midnight date roll over - Fixed an issue with KIC functionality for take/release control, set point transfer and saveas kicprofile recipe. (KIC2000 version 3001). - removed "Regain Control" sub menu under Utilities - Pop up messages for oven release/regain control are removed. Append title bar to display remote control when oven program released control to third party program like SECS/GEM - Improved rail exercise functionality - Fixed an issue when rail is switched from manual to computer mode during recipe load; wait for user responce before moving rail - Fixed an belt stop issue when Auto log down feature is enabled. This was noticed in 6.0.0.7. 6.0.0.14 Dec-27-2010 Rev-B ECN110001-013 6.0.0.14A Mar-25-2011 Rev-C ECN110018-013 - Max board count in oven with SMEMA option added - Fixed: an issue for warning message needs to click more than once - Fixed an issue with high CPU usage when oven program is in operate mode running recipe 6.0.0.14C May-31-2011 - Fixed a program crash related to closed loop Dansensor with Standby option 6.0.0.15 Feb-10-2011 - Dual light tower option added. Total two light towers, for Lane1 and Lane2 each. - Dual lane special barcode system (Micron XXxxxxxxx-XXX-XXX) - For flux heater channel setup, display all 32 channels as part of drop down box - 6.0.0.16 Feb-25-2011 - ActiveX function call correction for GetRailWidth - ActiveX function call possible for rail width setting while boards in oven for other lane - Fixed: belt speed going to 0 when SP change using activex
6.0.0.17 Mar-11-2011 - Imported heat zone cooling PID option from 6.5.0.8 version - Added heat zone cooling on/off control selection (default) - Option to allow heat zone cooing output to skip startup sequence - Option to allow heat zone cooling output to be active in cool-down mode - Previous version recipe compatibility when heat zone cooling option is enabled - Global high process alarm Min setting possible is 25C (previously 200C) 6.0.0.18 Mar-16-2011 - Option: Digital output on/off based on board count > set value - Custom warning/alarm option: Change delay time max limit to 9999 from 30sec. - Option to allow blower speed at 100%/High during recipe startup sequence 6.0.0.18A Mar-28-2011 - Fixed an issue with high CPU usage when oven program is in operate mode running recipe 6.0.0.19 Apr-11-2011 - Option added: Energy saving setup window - 6.0.0.20 Apr-20-2011 - Board count/processing issue related to exit cutout distyance setup 6.0.0.21 May-27-2011 - Added Custome light tower setup option - Update for multi-lane (smema) barcode system 6.0.0.22 Jul-26-2011 - Added Alarm scanner option (using monitoring HC2 ctrl.) 6.0.0.23 void 6.0.0.24 Jul-28-2011 - Bugfix: Micron barcode fix (XXxxxxxxx-XXX-XXX) - Improved communication - Note: 1913 model disabled 6.0.0.25 Aug-30-2011 - Fixed: 1913 RL model - Previous recipe load without rail move and count reset - Add light tower setup for Ready (products in oven) mode - Setup wizard issue when back from page7 6.0.0.26 - Ocx/ActiveX corrections/update - KICLDO communication file for custom 3rd party functionality 6.0.0.27 - Add [LDO_INFO] tag to LDOChange file for KICLDO option - HC2updater change to not display confirmation message for every file - Corrected issue for touch screen optimized option
6.0.0.28 - Add capability for recipe name to include '.' - Fix: a blank string for S7F19 SECSGEM (list of recipe names) when oven program is in cooldown mode - Change language INI file entry IDSA_HIGH_H2O_TEMP=High water temp./low water flow alarm, Cooldown Loaded! - INI file spelling corrections: Exhuast to Exhaust - Added a log entry for recipe Save As to include recipe name - Fixed: Board stop warning did not worked in previous version - Fixed: Recipe name update in barcode program when loaded via calender - Added: Pegatron board entry barcode data logging option - Changed event log text file open behaviour: instead of open-close at each event, open when program starts and close when program close 6.0.0.29 Aug-10-2012 - Added: Harman MES option - Added new languages: Portugese, Vietnamese - Removed option to exit without HC2 shutdown - Correction: Pegatron board entry barcode data log option per customer feedback - Fixed: Calender event countdown bar was not working, noticed during 6.0.0.28 tests, - Added new oven models: 1910(10 zones), 1911(11 zones) - Fixed: an issue of heat channel color staying red when recipe is reloaded using previous recipe load button - Added: S7F25 (SECS/GEM formatted recipe upload) support - Fixed: Energy saving option correction for certain config 6.0.0.30 - Fixed: Belt speed issue when encoder input is on TDM(Voltage type) - Fixed: Green light tower if Dansensor warning is acknowledged individually in alarm screen and warning is still present - 6.0.0.31 Nov-08-2012 - GMT time for Barcode data log option - Improved PC to HC2 communication, single socket communication - Fixed: Issue of light tower not green when manual hardware rail option is active - Fixed: issue of rail move message does appear when oven program runs for the first time and manual rail input is active - Fixed: issue of OvenCPK Z13T PV value error, always showing Z6T PV
6.0.0.32 Nov-20-2012 - Fixed: HC2 reboot after 1024 board entry or after board count reset - Fixed: Animation for board#512 and 1024 was not displayed - 6.0.0.33 Dec-13-2012 - Added option: Blowers to run at 100% during recipe startup - Fixed: when KIC2000 sends a belt SP to oven program, it was getting converted to inch/min - Update barcode data log (Fuji/Pegatron) option to have intermediate TMP folder - Fixed: Board count reset button for multi-lane setup - Changed default to "Single" blower control for group A, B, C. D and E are already single. - Fixed: issue of oven program icons are not grayed out when program is in external or released control - Fixed: profile port 4, 5 were not reported (ActiveX) to KIC program - Fixed: barcode data log file will not create for 1st board if entrance and exit sensor is blocked at the same time - Fixed: board count, animation did not worked when cut-out distance was set to 0 - Fixed: setup wizard last page, High limit values were not able to change - Fixed: SECS/GEM related issues - - recipe START command was failing - - list of recipe command (s7f19) was not responding - - recipe delete s7f17, recipe upload s7f5, recipe download s7f3 was not responding - Fixed: Energy saving option setup issue: Standby mode-1 timer setting change did not get applied 6.0.0.34 Jan-04-2013 - Fixed: Audible alarm silence button is not working in 6.0.0.33 - Fixed: Board animation was not accurate when units are in inches with closed loop belt setup. Animation was slower than belt speed. - Fixed: Oven program crash when custom alarm 3 was enabled - Fixed: Dansensor warnings were active even if main N2 switch is OFF position - Applied belt speed slowdown issue correction. Issue was observed on ovens where lots of boards are processed at faster rate.
6.0.0.35 Jan-15-2013 Rev-D ECN130001-003 - Fixed: Program crash when heat zone cooling option is selected - Fixed: Barcode data log option was not working occasionally after program is restarted (specific after two two restarts or if program closed abnormally) - Fixed: board detection period window at exit end was broken in version 6.0.0.34 - In setup wizard, below options are now checked ON by default -- Warning on rise rate -- Blowers at 100% during recipe startup (Note: for HC2s with older than 6.0.0.31 driver version, drivers needs to get updated manually before program start) 6.0.0.36 Feb-26-2013 Rev-E ECN-130003-013 - Fixed: Barcode audible warning was not generated in previous version - Fixed: Autoclean recipe (Gen5-Recipe) option did not worked in previous version, Autoclean confirmation message did not worked. - Warning on rise rate option is unchecked by default now - Fixed: ActiveX notification events 20, 21 were not generating in previous version