Appendix A: Acceptable pipe and fitting materials



Similar documents
TG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION

Module 3: Sewer Material Lecture 3: Sewer Material

Module 3 : Sewer Material. Lecture 3 : Sewer Material

Pipeline Replacement using Relining

NEW CONNECTION INDUSTRIAL PRODUCTS NC.10V NC.20V NC.30V. NC. SD.10 NC. SD.20 NC. F.Clamp

Pipe System Acronyms

WATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION

Pipes and Fittings for Gravity Sewer Mains. SewerMAX

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

Water Supply Code of Australia WSA

WATER SERVICES ASSOCIATION OF AUSTRALIA WATER SUPPLY CODE OF AUSTRALIA

Section 2. Planning, Material and Design

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

SECTION 3 SANITARY SEWER DESIGN

Couplings. Drain Couplings Standard Couplings Large Diameter Couplings Adaptor Couplings Flexible Saddles Bushes

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

INDEX. Sec. No. Items Page Nos.

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

AGENDA. Pipe Materials / Trends The Reason for Change Design / Standards Pipe Selection Installation Examples Conclusion

SEWERS FOR ADOPTION 6 PIPE MATERIALS TABLE AND CONDITIONS OF USE VERSION 4 March 09

WATER SERVICE 2

PART 5 : WASTEWATER DRAINAGE

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

Before H 2 Town of South Windsor, CT Evaluates Large Diameter Concrete Pipe

British Standard Underground Hydrant Range

Rehabilitation or Replacement? That Is The Question

District Cooling Best Practices Piping Systems

Standard Specifications For Private Sewer Laterals

Pipe bursting provides viable alternative for rehab work By Greg Key, U.S. Pipe

SECTION POLYVINYL CHLORIDE (PVC) PIPE

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

Pipe Bursting. Case Study at Zeeland, MI Collections Seminar September 6, Presentation Agenda. What is Pipe Bursting? What is Pipe Bursting?

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Polyethylene Pressure Pipe

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

Sewer Rehabilitation Design Requirements

Ridgistorm-XL - the latest innovative

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SECTION STORM DRAINAGE SYSTEM

EARTHQUAKE DAMAGE TO PIPELINES A CHRISTCHURCH PERSPECTIVE

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

Quality ISO Engineering Design and Installation Guidelines for Flowtite GRP Pressure and Non Pressure Pipes


SPR PE Steel Reinforced Liner

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

GLASS REINFORCED PLASTIC (GRP) IN THE DESIGN OF A BORE WATER TRANSFER SYSTEM

Earthquake damage in wastewater systems and postearthquake repair methods; limitation and practice

MY ACCOUNT. HOW IT WORKS FOR YOU.

A Discussion of Steel Pipe versus Ductile Iron Pipe

TECHNICAL SPECIFICATION

HISTORY OF PLASTICS PIPE SYSTEMS IN AUSTRALIA

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

Standard Specification for the Laying of Sewer Lines and Appurtenances in the Hurunui District

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

LIFELINE PIPELINE RESTORATION AND SEISMIC MITIGATION

Fittings and valves. Ductile cast iron valves. for water and gas supply

Flowtite Jacking Pipe

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Special Linings for unusual service conditions. Please contact ACIPCO.

Compliance Document for New Zealand Building Code Clause G13 Foul Water Second Edition

SECTION SANITARY SEWER PIPE

Royal Seal Gasketed Sewer Pipe

SANITARY SEWER SPECIFICATIONS

THE DESIGN OF BUILDING SERVICES FOR EARTHQUAKE RESISTANCE

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

Technical. Design Data. Advanced Solutions for Pipe Technology

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

ABOUT US ABOUT PE THE DEFINITION OF POLYETHYLENE

HDPE. High-Density Polyethylene Pipe Systems. Meeting the challenges of the 21 st century

GAS INSTALLERS MANUAL CINERGY AND SUBSIDIARY COMPANIES CUSTOMER PROCEDURE FOR INSTALLING 3", 4", 6", AND 8" IPS PLASTIC GAS SERVICE PIPING

Ductile Iron Pipe Couplings

Scepter PVC Molded Junction Boxes

SECTION STORM DRAIN SYSTEM

LS 2540 SEWER LATERALS AND INSPECTION TEES

IS THAT LINER THICK ENOUGH?

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION DUCTILE IRON PIPE AND FITTINGS

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

TABLE OF CONTENTS 2.0 RELATED DOCUMENTS

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

GPD Rubber Press Seals

Reticulation sewers in basements Technical guidelines

Integrated Manhole Ladder System

HIGH DENSITY POLYETHYLENE

Uniclass L L2123 EPIC J3413. CI/SfB (52.5) Heavy duty channel drainage system ACO S Range

Transcription:

Watercare Services Limited Water and Code of Practice Content from the NZS 4404:2010 Land development and subdivision infrastructure has been reproduced for use in the Infrastructure Design s Manual for Local Networks with permission from s New Zealand under Licence 000805 Appendix A: Acceptable pipe and fitting materials Table A1 and table A2 on the following pages provides general information on acceptable pipe and fitting materials. Some of the information is sourced with permission from the Water Services Association of Australia, which is modified and supplemented by material from Watercare. Refer to Watercare for specifications on specific material type These tables are to be used as a guide only. December 2014 This is a controlled electronic document and is uncontrolled on printing Page 1 of 8

Content from the NZS 4404:2010 Land development and subdivision infrastructure Local Networks with permission from s New Zealand under Licence 000805 Table A1 Acceptable pipe materials and s PVC-U AS/NZS 1260 (Solid wall Class SN 16 or as PVC-O AS/NZS 4441 (Series 1 or Series 2, as PVC-U AS/NZS 1477 (PN 12 or PN 16, as December 2014 This is a controlled electronic document and is uncontrolled on printing Page 2 of 8 Gravity applications only. Well established methods of repair. Can be used for trenchless installations with suitable load resistant joints Improved fracture toughness compared to PVC-U. Improved fatigue resistance compared to PVC-U and PVC- M. NOTE Use only DI fittings in pumped mains to achieve full fatigue resistance. Has increased hydraulic capacity compared with PVC-U and PVC-M. Suitable for aggressive groundwater, anaerobic conditions and tidal pressure applications. Well established methods of repair. Alternative installation techniques possible, e.g. slip lining. Suitable for aggressive groundwater, anaerobic conditions and tidal Can be used for trenchless installation with suitable end load resisting joints. pressure applications.

Table A1 Acceptable pipe materials and s (continued) Content from the NZS 4404:2010 Land development and subdivision infrastructure Local Networks with permission from s New Zealand under Licence 000805 PVC-M AS/NZS 4765 (Class SN as Watercare PE AS/NZS 4130 AS/NZS 4131 (PE 80B SDR 11 or PE 100 SDR 13.6 or as NOTE: All PE pipes 63 mm OD are to be PE 80B. December 2014 This is a controlled electronic document and is uncontrolled on printing Page 3 of 8 Improved fracture toughness compared to PVC-U. Has increased hydraulic capacity compared with PVC-U. Inferior fatigue resistance compared to PVC-U and PVC-O. pressure applications. Generally for pressure applications. Can be easily curved to eliminate the need for bends. Alternative installation techniques, e.g. pipe cracking, directional drilling and slip lining. Can be welded to form an end load resistant system. Compression couplings and end load resistant fittings are available in smaller diameters. Pipe longitudinal flexibility accommodates large differential ground settlement. Fusion jointing requires skilled installers and special equipment. Retrospective installation of fittings / repair complicated. pressure sewer applications. DN 125 are available in long coiled lengths for fewer joints. Suitable for ground with high subsidence potential, e.g. fill or mining areas.

Table A1 Acceptable pipe materials and s (continued) Content from the NZS 4404:2010 Land development and subdivision infrastructure Local Networks with permission from s New Zealand under Licence 000805 PE AS/NZS 5065 (Stiffness Class SN 16, SDR 17, or as PP AS/NZS 5065 (Stiffness Class SN 16, as - GRP AS 3571.1 - December 2014 This is a controlled electronic document and is uncontrolled on printing Page 4 of 8 Only for gravity applications. Can be easily curved. Alternative installation techniques possible, e.g. pipe cracking and slip lining. Can be welded to form an end load resistant system. Fusion jointing requires skilled installers and special equipment. Retrospective installation of fittings / repair complicated. Smaller diameters available in long coiled lengths for fewer joints. Only for gravity applications. Alternative installation techniques possible, e.g. slip lining. UV resistant (special product). Custom made fittings can be manufactured. Suitable for use without additional corrosion protection in areas where stray electrical currents occur. Low impact resistance and ease of damage to thermosetting resin makes GRP susceptible to damage during transportation and installation in above ground installations, from vandalism or when damaged as a consequence of nearby excavation.

Table A1 Acceptable pipe materials and s (continued) Content from the NZS 4404:2010 Land development and subdivision infrastructure Local Networks with permission from s New Zealand under Licence 000805 GRP AS 3571.2 - - VC BS EN 295 - RRJRC (Rubber ring jointed reinforced concrete) AS/NZS 4058 December 2014 This is a controlled electronic document and is uncontrolled on printing Page 5 of 8 Alternative installation techniques possible, e.g. slip lining. UV resistant (special product). Custom made fittings can be manufactured. Suitable for use without additional corrosion protection in areas where stray electrical currents occur. Low impact resistance and ease of damage to thermosetting resin makes GRP susceptible to damage during transportation and installation in above ground installations, from vandalism or when damaged as a consequence of nearby excavation. Gravity applications only Has benefits for particularly aggressive industrial wastes. Not recommended for active seismic (earthquake) zones or unstable ground. Requires protection from hydrogen sulphide attack in sewer applications by plastic lining or selection of appropriate cement additives.

Table A1 Acceptable pipe materials and s (continued) Content from the NZS 4404:2010 Land development and subdivision infrastructure Local Networks with permission from s New Zealand under Licence 000805 CLS (SCL) NZS 4442 AS 1579 (Cement mortar lined welded steel, minimum thickness 4.8 mm) December 2014 This is a controlled electronic document and is uncontrolled on printing Page 6 of 8 Cement mortar lined, PE coating below ground or heavy duty coating above ground. High mechanical strength and toughness. Available in long lengths. RRJ welded joints are available. Custom made, specially configured steel fittings can be made to order. Can be welded to form a system that will resist end load and joint permeation. UV resistant / vandal proof / impact resistant (where PE coated). Cathodic protection (CP) can be applied to electrically continuous pipelines to provide enhanced corrosion protection. PE lined and coated RRJ. As above for CLS (SCL). Suitable for conveying soft water. Corrosion resistant under all conditions. General notes: Portland cement is not resistant to H 2S attack at any high points or discharge points in the main. High alumina cement has improved resistance. Welded joints require skilled installers and special equipment. Welded joints require reinstatement of protection system on site. Special design required for welded installations parallel and adjacent to high voltage ( 66kV) transmission lines. Cathodic protection requires regular monitoring and maintenance. Seal coating may be required over cement mortar linings when conveying soft water or in low flow extremities of reticulation mains, to prevent potentially high ph. Suitable for high load applications, such as railway crossings and major roads. Large diameters are available. Suitable for aerial or suspended pipeline applications.

Table A1 Acceptable pipe materials and s (continued) Content from the NZS 4404:2010 Land development and subdivision infrastructure Local Networks with permission from s New Zealand under Licence 000805 DI AS/NZS 2280 ABS PVC-U AS 3681 (Ductile iron pipe K9 or PN 35) AS/NZS 3518 AS/NZS 3690 AS/NZS 3879 AS/NZS 1260 December 2014 This is a controlled electronic document and is uncontrolled on printing Page 7 of 8 Fatigue analysis not normally required (pressure sewer application). High mechanical strength and toughness. Ease of jointing. UV resistant / vandal proof / impact resistant. Well established methods of repair. Suitable for high pressure and above ground pipelines. Restrained joint systems available. Sufficient ring stiffness not to rely on side support for structural adequacy for the usual water supply installation depths. Elevated ph may occur when conveying soft water or in low flow extremities of reticulation mains. PE sleeving is required and must be carefully applied and repaired when damaged. Portland cement mortar is not resistant to H 2S attack at any high points or discharge points in the main. High alumina cement has improved resistance. Not suitable for aggressive ground water, anaerobic conditions or tidal pressure sewer applications. Gravity applications only.

Table A2 Acceptable fitting materials and s Content from the NZS 4404:2010 Land development and subdivision infrastructure Local Networks with permission from s New Zealand under Licence 000805 Fitting materials PE AS/NZS 4129 Access covers and grates AS 3996 Ductile iron AS/NZS 2280 Ductile iron unrestrained mechanical couplings AS/NZS 4998 Metallic tapping bands AS/NZS 4793 (No plastic bands accepted) Fire hydrants NZS 4522 - - Resilient seated gate AS 2638.2 valves PE AS/NZS 5065 (Stiffness Class SN16, or as PP AS/NZS 5065 (Stiffness Class SN16, or as December 2014 This is a controlled electronic document and is uncontrolled on printing Page 8 of 8 PE pressure fittings, including mechanical compression, butt fusion or electrofusion, as approved by Watercare. Generally for pressure applications. Shall be coated with a polymeric coating, applied in accordance with AS/NZS 4158. Generally for pressure applications. Shall be coated with a polymeric coating, applied in accordance with AS/NZS 4158. Generally for pressure applications. Tapping bands used on flexible pipes shall be AS/NZS 4793 Type F that is full circle design. LG2 gunmetal tapping bands preferred for all applications. Ductile iron tapping bands shall be coated with polymeric coating, applied in accordance with AS/NZS 4158. Generally pressure applications. Gravity application only. Gravity applications only.