DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015



Similar documents
Polyethylene Pressure Pipe

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

HDPE. High-Density Polyethylene Pipe Systems. Meeting the challenges of the 21 st century

HIGH DENSITY POLYETHYLENE

Appendix A: Acceptable pipe and fitting materials

Introduction to Pressure Pipe Rehabilitation with CIPP

Austin San Antonio Beaumont

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

PEX Pipes for Service Line Applications

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE POTABLE WATER DISTRIBUTION SYSTEM

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

PEX Pipes for Plumbing Applications

AMIPOX GRE Pipe systems. Glass Reinforced Epoxy Pipe Solutions for various Applications

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer


Table of Contents 2.1 INTRODUCTION MATERIALS IN USE...2-1

Module 3 : Sewer Material. Lecture 3 : Sewer Material

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

LIFELINE PIPELINE RESTORATION AND SEISMIC MITIGATION

Section 2100-Trenching and Tunneling

SECTION SANITARY SEWER PIPE

DIVISION 4300 STORM DRAINAGE

Installation of Large Diameter Buried Pipes

Module 3: Sewer Material Lecture 3: Sewer Material

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

STRONG FLEXIBLE. HyperPure PURE

INDEX. Sec. No. Items Page Nos.

Oil and Gas Pipeline Design, Maintenance and Repair

X Planning X Quality X Maintenance & Operations

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

SECTION STORM DRAINAGE SYSTEM

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

12/8/2014. Brought To You By: This webcast is sponsored by NASSCO with the support of IPBA.

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

SECTION 603 SANITARY SEWER FORCE MAINS

SASTT contact details:

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

TG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

Section 4: NiResist Iron

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD

OUTLINE. How PEX pipes are made Capabilities of PEX pipes, standards, testing PEX pipes for Plumbing and other applications

San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS

Before H 2 Town of South Windsor, CT Evaluates Large Diameter Concrete Pipe

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION STORM DRAINAGE TABLE OF CONTENTS

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

Royal Seal Gasketed Sewer Pipe

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

Culvert Repair, Materials, and Structural Design 4.4-1


MEMORANDUM: RECOMMENDATIONS FOR PIPE MATERIAL SELECTION

More inside :: Tackle even the toughest water treatment piping challenges with

CULVERT AND STORM SEWER PIPE MATERIAL POLICY ON FEDERALLY FUNDED LOCAL AGENCY PROJECTS UPDATED March 2013

Superior Pipe Restoration Solutions. Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

PLUMBING ROUGH IN INSPECTION

DRESSER TM PIPELINE SOLUTIONS

OAR52 A-1 (September, 1981)

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

ROOF DRAINS TABLE OF CONTENTS

Ultraviolet (UV) Light Cured Fiberglass Reinforced Cured-In-Place Pipe (CIPP) It is not just for sanitary sewer rehabilitation

Pipeline Replacement using Relining

SECTION STORM DRAIN SYSTEM

Flowtite Jacking Pipe

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

Water Damage & Repair

Standard Specifications For Private Sewer Laterals

TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING

Water Transmission & Sewer Force Main Renewal 16 through 60

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

8-11 Structural Analysis and Fill Height Tables Pipe Cover Shallow Cover Installation Fill Height Tables...

SECTION POLYVINYL CHLORIDE (PVC) PIPE

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Steam System Best Practices Condensate System Piping

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Ridgistorm-XL - the latest innovative

Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation

Repair or Replacement - Band-Aids vs. Surgery

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

PVC-Free Pipe Purchasers Report by Jamie Harvie with Tom Lent

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

PEX TUBING FAQ WHAT IS PEX?

Building Owners Guide to a Duro-Last System!

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Transcription:

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT Jim Riley, Texas A&M University February 10, 2015

Piping at Texas A&M 2 History of Distribution Piping at Texas A&M Concrete reinforced piping Concrete Ductile iron Galvanized Copper Clay tile Steel Stainless Steel HDPE is now used on all water systems

HDPE Piping Specifications PIPING High Density Polyethylene (HDPE) PE 4710 Dow 2499 resin (140 180 F) SDR 11 on all pressurized systems SDR 17 for sanitary sewer piping Corrugated SDR 17 for storm water piping INSULATION Mineral powder (GILSULATE 500) to meet insulative qualities, density and compaction requirements 3

HDPE Piping Benefits No corrosion Long joint free runs (20 to 50 feet) Limited impact by ground shearing forces Extremely flexible less joints Decreased friction improved flow characteristics Minimal internal material build up Longevity 100+ year pipe Wide range of operating conditions Does not deteriorate in sun light Easier installation and repair 4

HDPE Piping Techniques 5 Simple slip-lining Swaglining Fold and band pipe insertion Static pipe bursting Open trench Boring

Projects Chilled water lines with Gilsulate insulation 6

Projects Reroute of 12 domestic cold water line around Olsen ball park 7

Projects Chilled water supply and return to a dorm on campus 8

Projects Chilled water and heating hot water supply and return to a new rec facility dorm on campus 9

Projects East/West Utility Corridor 10

Projects West Campus Thermals West Campus Storm Drain 11

GILSULATE 500XR A standard in efficiency, sustainability and environmentally stable. Underground Controlled Density Insulating Fill & Corrosion Protection System 12

Insulating your underground distribution system with a highly efficient and reliable system can provide a return on your investment many times over. Benefits include: ROI: Proven quick payback, savings are compounded over the life of the system. Minimize maintenance: Maintenance is eliminated. Maximize Equipment Life: Highly efficient insulation extends your equipment life. Reduce Greenhouse Gas: Emitting less gases because the system burns less fuel. Use LESS Existing Available Energy: Promote creating less new energy. Prevent Corrosion: One products insulates and protects your metallic piping system. Gilsulate The Trade Name with 70 Years of Research, System Design and Testing 13

Gilsulate 500XR is patented as an underground insulation, providing corrosion protection and excellent load bearing properties Exceeds UFGS 33.61.13 (2.4) including Manufacturer, ASTM Code & Standard requirements Meets ASTM C177 04 Installed Meets ASTM D 1895 Method A & C installed Works in Multiple Temperature Zones: Temperature range of 35 F 800 F. Fits any size pipe, type of pipe, or configuration of pipes out of the bag. High Load Bearing Material Will support the weight of the pipe, backfill & roadway. High Electrical Resistivity Prevents Corrosion Prevents water intrusion to the piping system For Underground Distribution Systems Chilled Water, Hot Water, Steam, Condensate 14

HDPE AND PP RCT PIPING SYSTEMS IDEA Campus Energy Denver, CO 10 February 2015 15

HDPE and PP-RCT Indoor vs. Outdoor Indoor PP-RCT Outdoor - HDPE 16

HDPE WHY CHOOSE HDPE Benefits of HDPE Pipe Systems Homogeneous, monolithic thermal fusion joint Zero Leakage Fully Restrained No Thrust Blocks Allows Installation Under Tension (HDD, Pipe Bursting, and slip lining) Butt fused joint is as strong as pipe 17

HDPE - MATERIALS Features and Benefits, Cont. Hydraulically efficient Smooth non wetting bore Maintains Hazen Williams C Factor (C = 150) Long Term Corrosion, abrasion & chemical resistant Does not rust, rot, corrode, or tuberculate Resistant to acids, bases & salts Requires no lining, no coating, or cathodic protection 18

HDPE THOSE POOR PUMPS Benefits of HDPE Pipe Systems Ductile Iron Pipe Tuberculation in 10 Years HDPE Pipe Tuberculation Free Lifetime WHAT IS SUPPLYING YOUR EQUIPMENT? ISCO HDPE is completely corrosion resistant, offering the best quality supply for your equipment and bottom line. 19

HDPE - MATERIALS Features and Benefits, Cont. Life span of 50 100 years Available in sizes 12mm (1/2 ) to 2000mm (78 ) Pressure Rated up to 60 C (140 F) * Drainage 82 C (180 F) Pressure/temperature matrix basis at 22 C/73 F 20

HDPE Always Improving NEW FORUMLA RESIN 2499 - HHW lines Life span of 50 100 years UV Inhibited for above ground use Available in sizes 50mm (2 ) to 1625mm (65 ) Pressure Rated up to 82.2 C (180 F) 21

HDPE - SPECIFICATIONS Grade Designation AS/ZNS, ISO, ASTM AS/NZS AS/NZS 4131 Resin AS/NZS 4130 Pipe AS/NZS 4129 Fittings Resin: PE100 ISO ISO 4427 1 General ISO 4427 2 Pipe ISO 4427 3 Fittings ISO 4427 5 Fit for Purpose Resin: PE100 ASTM ASTM F714 Pipe ASTM F2206 Fittings ASTM F2620 Fusion Resin: PE3608/PE4710 22

QUALITY ASME & ISCO s Commitment to Quality HDPE used in Commercial and Safety Related piping systems Factory Mutual (FM) Approved ASME Code Cases N 755 & N 808 ISCO is first ASME HDPE Piping System Certificate of Authorization Holder ISO 9001:2008 Program N 3822 N 3680 23

24 PP-RCT: Replacing theses systems near you

PP-RCT For your inside job HIGH TEMPERATURE HOT (POTABLE) WATER, COMPRESSED AIR HVAC/HYDRONIC, CHEMICAL TRANSPORT COMPRESSED AIR COLD (POTABLE) WATER 25

PP-RCT The CT Difference System Design = 180 F @ 100PSI PP RCT= DR11 P R= DR6 1.) Less material = quicker fusion time = lower cost 2.) Larger Inside Diameter (I.D.) = greater flow 3.) Lighter to handle and install 26

PP-RCT The CT Difference System Design = 203 F PP RCT DR 7.4 = 120PSI PP R DR7.4 = 60PSI At elevated temperatures, PP RCT can handle twice the pressure compared to standard PP R 27

PP-RCT: Reliability A permanent homogeneous, leak free connection The most reliable connection Does not require glue, O rings, solder or gaskets to form a connection Heat Fusion Trusted by the AGA for more than 30 years, this method makes our joints the strongest part of the system 28

29 PP-RCT: Pipes are like veins

PP-RCT REDUCED INSULATION Better natural R Value compared to metallic piping systems 30

PP-RCT: Quick Test Socket Fusion: ½ -4 Butt Fusion 2 24 Both can be Air Tested 31

Environmentally Friendly PP-RCT ECO-FRIENDLY PIPING SOLUTIONS PP RCT does not emit any toxins, or carcinogens when burned. 100% Recyclable 32