HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 office@heddermanengineering.com



Similar documents
HEDDERMAN ENGINEERING, INC Carrie Cove Ct., Spring, TX , fax

PROFESSIONAL ENGINEERING INSPECTIONS, INC.

5006 Cherry Ridge Road Richmond, Texas LIMITATIONS AND DISCLAIMERS

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

National Home Builder - Name Wednesday, August 20, 2014 Regional Customer Care Manager 1234 Main Street Houston, Texas 77067

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

Lighthouse Engineering, L.L.C.

Lighthouse Engineering, L.L.C.

Lighthouse Engineering, L.L.C.

Simpson Engineering A state licensed engineering firm F-1607

A RESIDENTIAL PROPERTY LOCATED AT xxxxxxxxxxxxxx, PASADENA, TX 77505

October 30, Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

Pre-Drywall Inspection Report

Lighthouse Engineering, L.L.C.

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

HomeSpec REPORT SUMMARY

Estimated Cost of Repair

Structure Survey Findings:

Home Inspection Report

Self-Home Inspection Checklist

Inspection of the exterior found a tree in the back yard and a tree in the front yard within influential distance from the residence foundation.

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

SAMPLE REPORT. Convention regarding directions: Front faces the street, left and right are as seen from the street facing the house.

LIMITED ONE-YEAR WARRANTY SELLER S RESPONSIBILITY

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

Building Condition Assessment Report

PRE-PURCHASE INSPECTION REPORT

Exterior Elevated Elements Inspection Guidelines

PROPERTY INSPECTION REPORT

Property Inspection Report

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

What you need to know about concrete block basement construction.

Building Condition Assessment: West Lexington Street Baltimore, Maryland

BUILDING PERMIT SPECIFICATIONS

symptoms of a faulty foundation

D Sample Notices to Property Owners, Sample Affidavits, and Other Material

Chapter 3 Pre-Installation, Foundations and Piers

Structural Assessment Report

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

October 5, 2015 Dear Client,

Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm

All CDBG-DR Program Subrecipients. Texas General Land Office. Date: August 20, Damage Assessment Guidelines

Vision Home Inspection

How To Prevent Water Damage To A Home

STRUCTURAL ASSESSMENT

Inspecting to a higher standard.

Inspection Report. Mr. John Homebuyer. Property Address: 123 Main Street Houston TX Front View. EDP Consulting Engineers, PLLC

Home Warranty Inspection Report

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

PERMIT APPLICATION FORM SELECT ALL THAT APPLY: BUILDING DRIVEWAY ELECTRICAL PLUMBING HEATING DEMOLITION SIGN MOBILE HOME

I NI NP R Inspected Items

PROPERTY INSPECTION REPORT

CONDITION OF QUALITY ITEMS

10 Secrets of Home Inspections Every Home Buyer Should Know

Proposed Minimum Subterranean Termite Treatment Standards

December 24, SEDA Construction Attn: Ted Walker 2120 Corporate Square Boulevard Jacksonville, Florida 32216

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

Comment Form on Proposed Gut Rehabilitation Alternatives

Propery Inspection Report

Roof Inspection. Summary Report

14 September Sarah Zorn Planning and Economic Development 25 West Fourth Street, Ste St. Paul, MN 55102

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

C I T Y O F P E A R S A L L

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

Water Damage & Repair

SECTION 3 ONM & J STRUCTURAL ANALYSIS

Common Problems with Walls

Foundation Repair Fundamentals And how they relate to the Real Estate Industry in the DFW Area

Steve Brinkman Alain Pinel Realtors 167 S San Antonio Road Los Altos, CA RE: Foundation Inspection for 162 Del Monte Ave. Los Altos, CA 94022

FORENSIC INVESTIGATION QUESTIONNAIRE

HOME INSPECTION CHECKLIST

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

YOU VE BEEN HIRED AS A GENERAL CONTRACTOR

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Home Inspection Report

March 19, Ms. Jean McDonald CAP Management th Street, Suite 1010 Denver, Colorado 80202

PELHAM MEMORIAL HIGH SCHOOL STONE FAÇADE REPORT. November 2007

123 Frontage Rd. Fort Worth Inspected Address City Zip Code

Total Home Inspection Checklist

ARROWHEAD GENERAL INSURANCE AGENCY RESIDENTIAL EARTHQUAKE INSURANCE PROGRAM UNDERWRITING GUIDELINES & RATE MANUAL

ELIGIBLE REPAIR PROJECT PARAMETERS

GOOD NEWS BUT NOT ALWAYS

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

Prestige Home Inspection LLC

Does Wall Township require an inspection by the building department on resale of a home?

New FHA Appraisal Reporting Requirements By TJ McCarthy, SRA, IFA

StuccoSpec Moisture Testing Inspection

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

941 Key Street HPO File No CERTIFICATE OF APPROPRIATENESS

MINE SUBSIDENCE CLAIM INVESTIGATION PROCESS

Roof Inspection. Summary Report

GreenGuard Housewrap Installation Guide

Transcription:

HEDDERMAN ENGINEERING, INC. www.heddermanengineering.com Office 281-355-9911, Fax 281-355-9903 office@heddermanengineering.com, 2011 TO: Mr. REF: CONDITION OF PROPERTY SURVEY Dear Mr. : At your request, a visual survey of the foundation of the house located at, Houston, Texas was made by Mr. Tim Hedderman. Transmitted herewith is the inspection report stating my professional opinion on whether the foundation is performing its intended function, or is in need of repair. Thank you for asking HEDDERMAN ENGINEERING, INC. to perform this important inspection work for you. If you have any questions after reviewing this report, please feel free to call me at my office. Sincerely, HEDDERMAN ENGINEERING, INC. Tim Hedderman, President

Address PURPOSE INTRODUCTION The purpose of the inspection was to view the evidences of differential movement of the foundation, and give our professional opinion on whether or not the foundation was performing its intended function at the time of the inspection, or was in need of repair. It is pointed out that, due to the subjective nature of interpretation of the evidences of foundation movement, it is possible for other professionals to have a differing opinion. This report is provided for the use of the person to whom this report is addressed, and is in no way intended to be used by a third party, who may have different requirements. It is our purpose to provide information on the condition of the foundation on the day of the inspection, and not to provide discussions or recommendations concerning the future maintenance of the foundation. It is our purpose to provide information on the condition of the house on the day of the inspection, and not to provide discussions or recommendations concerning the future Page 2

maintenance of any part of the house, or to verify the adequacy and/or design of any component of the house. It is pointed out that other engineers/inspectors may have contrasting opinions to those given in this report. SCOPE The scope of the inspection included limited, visual observations at the interior and exterior of the structure. Only those items readily visible and accessible at the time of the inspection were viewed, and any items causing visual obstruction, including, but not limited to, furniture, furnishings, floor or wall coverings, foliage, soil, appliances, insulation, etc., were not moved. Also excluded from the scope of this inspection is any discussion of or condition relating to geological faults and/or subsidence. The basis of our opinions will be the apparent performance of that portion of the house readily visible at the time of the inspection. Disassembly or removal of any portion of the structure is beyond the scope of this inspection. We make no representation regarding the condition of this property other than as contained in this written report. Any verbal discussions concerning this property that were made at the time of the inspection, and not contained in this written report, are not to be relied upon. There is no warranty or guarantee, either expressed or implied, regarding the habitability, future performance, life, insurability, merchantability, workmanship, and/or need for repair of any item inspected. DESCRIPTION OF HOUSE The house was a 4-5 bedroom, 4 2-1/2 bath, two story wood frame dwelling with stucco veneer, a composition shingle roof, and was supported on a monolithic slab on grade concrete foundation. The house had a two car attached garage. The house was occupied at the time of the inspection, and the age of the house is estimated to be approximately four years. FOR THE PURPOSES OF THIS INSPECTION, NORTH WILL BE ASSUMED TO BE FROM THE FRONT OF THE HOUSE TOWARDS THE REAR. Page 3

OBSERVATIONS AND CONCLUSIONS FOUNDATION Description The foundation was a concrete slab on grade, and appeared to be reinforced with steel reinforcing rods (rebar). Observations Evidences and consequences of differential movement of the foundation observed during the inspection include: * Normally horizontal surfaces, such as floors, door tops, counters, window sills, etc., were observed to be sloping generally from the rear of the house towards a low area at the front wall of the house at the study. The floors were checked with an electronic level, and the difference in elevation between the high point and low point was 1.8 inches on the first floor and 2.2 inches on the second floor. See our field sketch showing the elevation readings at the end of this report. Note that the R on the sketch is our randomly chosen starting reference point, where the elevation is 0, and all other elevation readings are taken relative to the reference point, and are measured in inches to the nearest 1/10 inch. Note also that elevation readings taken at the garage area are relatively large numbers relative to the reference point due to the step down into the garage area. We typically point out that foundations are rarely constructed perfectly level, so most houses have some unlevelness (typically ¾ to 1-1/2 inches) built into the foundation as part of original construction. We have no knowledge as to how much unlevelness was built into this house foundation. (Information) * Cracks and/or patches were observed in the exterior stucco veneer at all four sides of the house, as seen in the photos below. The cracks in the stucco were in accordance with movement of the foundation as seen in the elevation survey at the end of the report. Page 4

Page 5

Page 6

* Sheetrock cracks, patches, or compression ridges were observed several locations as seen in the photos below. The location and direction of the cracking is in agreement with the sloping of the floors to indicate settlement of the foundation towards the low area of the house at the front wall of the study. Note that the following is only some, not all, of the cracks observed in the house. Page 7

Page 8

Page 9

Concrete Cracks * The foundation concrete was observed to be cracked at throughout the downstairs area and the garage, where the concrete was visible. Page 10

The corner of the foundation was observed to be chipped. This is condition that is caused by differences in thermal expansion between the brick veneer, and the concrete foundation. Also, this condition can be caused by a lack of reinforcement in the corner of the foundation during original construction. In our opinion, this condition does not affect the structural integrity of the foundation. Page 11

Separations of Materials * Some separations and differential movement of materials due to differential foundation movement were observed, including the following: - A separation was visible at the bottom of the door trim at the kitchen pantry and wine room area. - A door was sticking at the upstairs west center bathroom. Page 12

- The floor tiles at the upstairs west center bathroom were separated from the edge of the tub. Other Observations Trees and/or foliage were observed in the vicinity of the house, which can contribute significantly to differential movement of the house foundation. Care should be taken to prevent the trees and foliage from removing an excessive amount of water from near the foundation of the house. Consideration should also be given to cutting the tree roots that extend under the foundation, and installing a root barrier to prevent any further moisture from being removed from under the interior of the house. Conclusions Most of the structures previously inspected by this firm have experienced some degree of differential foundation movement, and this structure was no exception. After careful examination, it is our opinion that the degree of the foundation movement is more than what is acceptable. Due to the more than acceptable amount of movement of the foundation of this structure, it is our opinion that releveling of the foundation is needed at this time. It is recommended that at least three foundation repair contractors be contacted in order that they may make their own assessment of the scope and cost of the work needed to bring this foundation back to an acceptable degree of levelness. Obtain Cost Estimate Perimeter Grading/Drainage This inspection does not include determining if the property is in the 100 year flood plain. For further information regarding elevation of this lot check with your survey and/or an appraiser. The perimeter drainage around the property appeared to generally be adequate. It was Page 13

not raining at the time of the inspection and, therefore, it could not be determined with certainty if water would pool at any localized low areas around the property. UNDERGROUND DRAIN The underground drainage system at the rear of the house was checked by running water into the drain for approximately 15 minutes, and the system was observed to be draining properly to the street. CLOSE Opinions and comments stated in this report are based on the apparent performance of the foundation on the day of the inspection. Performance standards are based on the knowledge gained through the experience and professional studies of the inspector. There is no warranty or guarantee, either expressed or implied, regarding the habitability, future performance, life, merchantability, and/or need for repair of the foundation. Sincerely, Tim Hedderman Registered Professional Engineer #51501 Texas Firm Number: 7942 The seal appearing on this document was authorized by Tim Hedderman, P.E. 51501. Alteration of a sealed document without proper notification to the responsible engineer is a violation under the Texas Engineering Practice Act. Page 14

Page 15

Page 16