Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series



Similar documents
Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Givare NC-SRS 280 och 880

Reaction Torque Sensor

Safety at a high level!

How To Use A Flowmeter

Series 6000 Torque measured metal bellow coupling

Inductive sensor NI10-M18-Y1X-H1141

TECHNICAL DATASHEET Incremental Encoder RI 58-H

Absolute Rotary Encoder E6CP

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Turbine Flow Sensor Series VTR

Description. Dimensions. Features. precision works better

Displacement encoders

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Sense it! Connect it! Bus it! Solve it! EncoderS

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

3-Component Measuring System

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

Knob Potentiometer with Switch

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Capacitive Prox E2K-X

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Low Frequency Velocity Sensor

1/2" (12.7 mm) Conductive Plastic and Cermet Potentiometer

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Electric Rotary Actuator - On/Off or programmable control actuator

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

ABSOLUTE ROTARY ENCODER ETHERNET/IP

RY2 miniature industrial relays

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Contents. Document information

Knob Potentiometer FEATURES. P16NP P16NM Panel Cutout. Thickness nut 2 mm washer 1.5 mm. Panel sealing ring 12 wrench Thread M10 x

How To Drive A Compact Serie 1

Trapezoidal-Connectors Series TMC

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

4 Posiflow Proportional Solenoid Valves

2.12. page Products for Explosion hazardous Environment

SOURIAU s discrete wire sealing

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Mini USB and USB 2.0-IP67 Connector System

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

Electro-Pneumatic Bus Door Control Mechanism

Relative and absolute pressure switch type 529

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

D.C. Motors. Products and specifications subject to change without notice.

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Selector Switch Type 08

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Differential Charge Amplifier

How To Read A Pipe From A Sensor

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Proximity Transmitters and Seismic Vibration Transmitters

Electronic Length Measuring Equipment

HERZ-Thermal Actuators

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

System 8. ü ( System 8

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Electronic Pressure Switch EDS 3000

Cables. Accessories. For Force, Torque and Strain Sensors

Series description: Wilo-Yonos MAXO-D

Encoder WDGI 58H.

Mounting Instructions. Torque Transducer. A en

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

2/2 and 3/2 Way Size 6 Seat Valves

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Electronic Pressure Switch EDS 300

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

and Accelerometers

Series 7500 Torque Sensor

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Centro-Matic Automatic Lubrication Systems System Controls

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Electro-pneumatic control valves

Pluggable interface relays CR-P Pcb relays

Transcription:

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN standard gauging end double bearing system on shaft insensitive to shock and vibration Repeatability to ±0.002 mm Position sensors employing conductive-plastic resistance and collector tracks provide direct means of measuring position or profile, without the need of a solid mechanical coupling. One important feature of the TR, TRS Series is the industry proven double-bearing systems on both actuator shaft and spring. This arrangement reduces side load errors that could occur in an application such as cam-following and is one of the design factors that enables the outstanding linearity of this series. The back end of the actuator shaft has a special collar that allows the attachment of an air cylinder of solenoid to automatically retract the actuator when required. Description Housing aluminum, anodized Actuating shaft stainless steel with anti-rotation device, inside thread M 2.5 x 6 Fixings adjustable clamps Gauging head stainless steel with external M 2.5 thread and hardened ball point Bearings both ends in DU plastic bearings Resistance element conductive plastic Wiper assembly precious metal multi-finger wiper, elastomer-damped Electrical connections type TR three conductor stress-relieved, shielded cable, 2 m type TRS plug connector

Type designations TR 10 TR 25 TR 50 TR 75 TR 100 with cable TRS 25 TRS 50 TRS 75 TRS 100 with plug Electrical Data Defined electrical range 10 25 50 75 100 mm Nominal resistance 1 1 5 5 5 kω Resistance tolerance 20 ±% Independent linearity 0.25 0.2 0.15 0.1 0.075 ±% Repeatability 0.002 mm Recommended operating wiper current 1 µa Max. wiper current in case of malfunction 10 m Max. permissible applied voltage 24 42 42 42 42 V Effective temperature coefficient of the output-to-applied voltage ratio typical 5 ppm/ K Insulation resistance (500 VDC, 1 bar, 2 s) 10 MΩ Dielectric strength (50 Hz, 2 s, 1 bar, 500 VAC ) 100 µa Mechanical Data Overall length (dimension A) 48 63 94.4 134.4 166 +1 mm Mechanical stroke (dimension B) 15 30 55 80 105 ±1.5 mm Dimension C (at TR) 7 12 12 12 12 mm Dimension D (at TR) 6 32 32 32 32 mm Weight with cable 80 120 150 180 200 g with plug 74 100 128 150 g Weight of the actuating shaft with coupling and wiper block 18 25 36 48 57 g Operating force (horizontal) 5 N Operating frequency max. 20 18 14 11 10 Hz (In critical applications mount the transducer with the gauging head upwards.) Maximum permitted torque for fixing screws 140 Ncm Included in delivery 2 fixing clamps Z 45 incl. 4 screws M4x10, 1 gauging head with hardened ball point Recommended accessories Plug type EEM 33-70, protection class IP 67 Plug type EEM 33-71, Plug type EEM 33-72, 1 roller head Z 50 Process-controlled indicators MAP... with display, Signal conditioner MUP.../MUK for standardized output signals Important All values given for this series including linearity, lifetime, microlinearity, resistance to external disturbances and temperature coefficient in voltage dividing mode are quoted for the device operating with the wiper voltage driving an operational amplifier working as a voltage follower where virtually no load is applied to the wiper (le 1 µa). Environmental Data Temp. range -30...+100 C Vibration 5...2000 Hz A max = 0.75 mm a max = 20 g Shock 50 g 11 ms Life > 100 x 10 6 movements Protection class IP 40 (DIN 400 50 / IEC 529) Order designations Type Art. no. TR 10 023260 TR 25 023261 TRS 25 023271 TR 50 023262 TRS 50 023272 TR 75 023263 TRS 75 023273 TR 100 023264 TRS 100 023274 Subject to changes February 2007 Novotechnik U.S., Inc. All rights reserved.

Position Transducers with restoring spring 10, 25,50,75, 100 mm Series TR, TRS Position sensors employing conductive-plastic resistance and collector tracks provide direct means of measuring position or profile, without the need of any form of solid mechanical coupling. Special features long life - 100 x 10 6 movements outstanding linearity - up to 0.075 % choice of plug or cable connection DIN standard gauging end double bearing system on shaft insensitive to shock and vibration An important and special feature of these particular units is their robust, industry-proven design. Of particular significance is the double bearing arrangement which really comes into its own when side forces (such as would be experienced in a cam-following application) are met. The rear end of the actuator shaft has a special collar, which can be very easily employed where automatic retraction by means of air cylinders or solenoid is required. Description Housing aluminium, anodized Actuating shaft stainless steel with anti-rotation device, inside thread M 2.5 x 6 Fixings Gauging head Bearings Resistance element Wiper assembly adjustable clamps stainless steel with external M 2.5 thread and hardened ball point both ends in DU plastic bearings conductive plastic precious metal multi-finger wiper, elastomer-damped Electrical connections type TR type TRS 3core stress-relieved, shielded cable, 2 m plug connector

Type designations TR 10 TR 25 TR 50 TR 75 TR 100 with cable TRS 25 TRS 50 TRS 75 TRS 100 with plug Electrical Data Defined electrical range 10 25 50 75 100 mm Nominal resistance 1 1 5 5 5 kω Resistance tolerance 20 ±% Independent linearity 0.25 0.2 0.15 0.1 0.075 ± % Repeatability 0.002 mm Recommended operating wiper current 1 µa Max. wiper current in case of malfunction 10 m Max. permissible applied voltage 24 42 42 42 42 V Effective temperature coefficient of the output-to-applied voltage ratio typical 5 ppm/ K Insulation resistance (500 VDC, 1 bar, 2 s) 10 MΩ Dielectric strength (50 Hz, 2 s, 1 bar, 500 VAC ) 100 µa Mechanical Data Overall length (dimension A) 48 63 94.4 134.4 166 +1mm Mechanical stroke (dimension B) 15 30 55 80 105 ±1.5 mm Dimension C (at TR) 7 12 12 12 12 mm Dimension D (at TR) 6 32 32 32 32 mm Weight with cable 80 120 150 180 200 g with plug 74 100 128 150 g Weight of the actuating shaft with coupling and wiper block 18 25 36 48 57 g Operating force (horizontal) 5 N Operating frequency max. 20 18 14 11 10 Hz (In critical applications mount the transducer with the gauging head upwards.) Maximum permitted torque for fixing screws 140 Ncm Environmental Data Temperature range -30...+100 C Vibration 5...2000 Hz A max = 0.75 mm a max = 20 g Shock 50 g 11 ms Life > 100 x 10 6 movem. Protection class IP 40 (DIN 400 50 / IEC 529)

Order designations Type Art.no. TR 10 023260 TR 25 023261 TRS 25 023271 TR 50 023262 TRS 50 023272 TR 75 023263 TRS 75 023273 TR 100 023264 TRS 100 023274 Included in delivery 2 fixing clamps Z-45 incl. 4 screws M4x10, 1 gauging head with hardened ball point Recommended accessories Plug type EEM 33-70, protection class IP 67 Plug type EEM 33-71, Plug type EEM 33-72, 1 roller head Z 50 Process-controlled indicators MAP... with display, Signal conditioner MUP.../ MUK for standardized output signals Important All the values given in this data sheet for linearity, lifetime and temperature coefficient in the voltage dividing mode are quoted for the device operating with the wiper voltage driving on operational amplifier working as a voltage follower, where virtually no load is applied to the wiper (l e 1 µa). Änderungen vorbehalten