OFFICE OF THE STATE FIRE MARSHAL DELAWARE



Similar documents
CODING QUESTIONS MANUAL

NFIRS 5.0 Coding Questions and Answers A Reference Guide

Federal Client Tool Data Entry Tool, NFIRS V594

NFIRS Incident Reporting. For ECFR Firehouse Web

Medical Facility Fires

In 1980, the National Fire Protection Association (NFPA)

Fire Safety Risk Assessment Checklist for Residential Care Premises

Fire Sprinkler Fact Sheet

FIRES IN HEALTH CARE FACILITIES

Get Alarmed, Tennessee! Smoke Alarm Program Saves

Vacant Residential Building Fires

FIRE SPRINKLER TALKING POINTS

Section 9 Major Urban Fire

National Fire Incident Reporting System (NFIRS 5.0) Configuration Tool User's Guide

ONBASE OUTLOOK CLIENT GUIDE for 2010 and 2013

6. GIVE FULL DETAILS OF TYPE OF WORK, OPERATIONS AND ATTACH BROCHURES IF APPLICABLE:

Contacting ACS FIREHOUSE Solutions: Sales: International

MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES

AiM User Guide Property Module

National Fire Incident Reporting System (NFIRS 5.0) NFIRS Data Entry/Validation Tool Users Guide

Professional Fire Software Control Center. Fire Training Module Training Manual

The terms hazard and risk are often used, which we define as the following:

Daycare Center Fires

How do I share a file with a friend or trusted associate?

Pinole Fire Department

ACHieve Access 4.3 User Guide for Corporate Customers

Hotel Fire Safety for staff

How To Build A Basement House

Smoke & Carbon Monoxide

Instructions for Completing the University of Saskatchewan Incident Report Form

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Fire Investigation I FST 205. COURSE SYLLABUS Fire Investigation I FST 205 [Semester] CRN 3 Credits

FIRE SAFETY ONLINE TRAINING

Table of Contents Introduction Page 3. Definitions Page 3. District Description Page 4. Legal existence of the fire district Page 4

Smoke Alarm Performance in Residential Structure Fires

Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems

Appendix A How to create a data-sharing lab

Performance Measures Overview Accessing Performance Measures Severity Circumstance Crash Type...174

Getting Started with Web Based Data Reporting. November, 2005

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

INSTRUCTIONS AND CONSUMER PROFILES DELAWARE ONLINE HEALTH INSURANCE RATE COMPARISON ISSUED APRIL 25, 2012

account multiple solutions

University of Alaska Statewide Financial Systems User Documentation. BANNER TRAVEL AND EXPENSE MANAGEMENT TEM (Quick)

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers

Contents INDEX...61 ECRM...1

eschoolplus Katy Independent School District Enrollment Online

Welcome to a whole new level of interactive home security

Business Objects Version 5 : Introduction

INSTRUCTIONS ON COMPLETING THE WORKERS COMPENSATION- FIRST REPORT OF INJURY REPORT

Configure SecureZIP for Windows for Entrust Entelligence Security Provider 7.x for Windows

National Fire Incident Reporting System (NFIRS 5.0) NFIRS Data Entry/Validation Tool Users Guide

Residential Fire Safety Policies

ManageMyHealth SMS Text Message Service User Guide. Medtech32. Version 20.0 (March 2012)

For use by landlords of small premises Premises Address

ASTP Online. Assisted School Travel Program. Student Rollover User Guide. NSW Department of Education

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition

Central Commissioning Facility Research Management Systems (RMS): User Guidance

BulkSMS Text Messenger Product Manual

Microsoft Access Rollup Procedure for Microsoft Office Click on Blank Database and name it something appropriate.

Update Instructions

Florida Market Assistance Plan Online Referral Agent Guide

Easy Grade Pro Progress Reports on the Web

ACT State Testing Online Services Tutorial

Banner Self-Service Direct Deposit Instructions Table of Contents

Spatial Database Support

1. Open the preferences screen by opening the Mail menu and selecting Preferences...

Fire Safety Risk Assessment

Highway Vehicle Fires

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

Online Appointments (Patients)

How to integrate Verax NMS & APM with Verax Service Desk

FIRE SERVICE PERFORMANCE MEASURES

Wellesley College Alumnae Association. Volunteer Instructions for Template

CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN

Information Server Documentation SIMATIC. Information Server V8.0 Update 1 Information Server Documentation. Introduction 1. Web application basics 2

CareAware Capacity Management - Patient Flow Patient List Gadget

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

University of Alaska Statewide Financial Systems User Documentation. BANNER TRAVEL AND EXPENSE MANAGEMENT TEM (Detail)

How to Add Users 1. 2.

Reference Document. SedonaOnline Support

Sable Altura Fire Department

SIGN Surgical Database Training Manual

2015 Fire Calls (as of 12/23/15)

PeopleAdmin. Creating a Posting for HR Users

(Sample) Building Emergency Plan

New volunteers will need to create a new username and a password to log into the system. This login information will be how you can access online

Attic Fires in Residential Buildings

Strategy & Tactics FST 202. COURSE SYLLABUS Strategy & Tactics FST 202 [Semester] CRN 3 Credits

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Transcription:

OFFICE OF THE STATE FIRE MARSHAL DELAWARE Data Entry in NFIRS 5.0 Step by Step Instructions State NFIRS Program Manager Lily Medina Office of the State Fire Marshal Delaware Fire Service Center 1537 Chestnut Grove Road, Dover, DE 19904 9610 Phone (302) 739 5665 Fax (302) 739 3696

Data Entry in NFIRS 1

Table of Contents Introduction... 4 Logging into NFIRS... 6 Opening a new report... 7 Section A or Key Information... 8 Adding a module... 10 Basic module... 12 Fire Module... 16 Structure Fire Module... 20 Civilian Fire Module... 22 Fire Service Casualty Module... 24 Saving the Report... 26 Delaware Fire Department Identification Codes... 30 Incident Type Codes... 31 Action Taken Codes... 42 *Last updated 1/7/1009 Data Entry in NFIRS 2

Data Entry in NFIRS 3

Introduction These instructions mainly cover the process for completing a VALID incident report. Mandatory fields within a fire report will be identified and a brief description given. Please note that fields become mandatory depending on the incident type and along with other factors. This guide can also be used to reference third party software such as CAD and Fire Programs. The same rules apply and all data that is required on NFIRS 5.0 is required on other fire reporting software as well. Although third party software may close out a report as being complete, it will still be considered invalid on the federal side if the same data entry requirements are not met in NFIRS 5.0. For more information, please refer to the NFIRS 5.0 Reference Guide, which can be viewed at http://www.nfirs.fema.gov/documentation/reference/ To gain access to the National Fire Incident Reporting System (NFIRS), an account needs to be created by the state NFIRS program manager. Incident reports that are entered on line will be available in real time. Fire departments using third party software must submit reports to the state NFIRS program manager in order to be fully processed and compliant with state and grant requirements. Reports are due monthly before the 10 th of the following month. NFIRS has 11 modules: Basic, Fire, Structure Fire, Civilian Fire Casualty, Fire Service Casualty, EMS, Hazmat, Wildland, Apparatus, Personnel and Arson. Only the first 5 modules are mandatory and required to be completed. The Basic module is required for all incidents. Data Entry in NFIRS 4

Data Entry in NFIRS 5

Logging into NFIRS 1. Log in to NFIRS. Figure 1. NFIRS login screen. User Name Enter the username assigned to you by the NFIRS program manager User State Enter the 2 character state abbreviation (i.e. enter DE for Delaware). Password Enter the password assigned to you by the NFIRS program manager. You can change your password once you have logged in. 2. After clicking OK on the initial login screen, the following window will appear. Click OK to proceed. Figure 2. Federal System Warning screen. 3. The next window to appear is the main NFIRS screen. This screen allows you to navigate through NFIRS to perform various functions such as querying and data entry. Data Entry in NFIRS 6

Opening a new report Figure 3. Main NFIRS screen. There are 2 ways to open a new incident report. Click on the tab and a menu of reporting options will appear. Choose New Incident to get started on a new incident report. Another way to create a new report is by clicking on the button. The button is used to query reports. When you click this button, another window will open with a variety querying options. Data Entry in NFIRS 7

4. After selecting New Incident in the tab or the button, the following window will appear. This window is the Key Information section of the incident report. This is also known as Section A. Section A or Key Information Figure 4. Section A or Key Information window. FDID This field should automatically default to your station s FDID. If this field is blank, click on the tab to choose your station. Date Enter the date of the incident in this field. Dates automatically default to the current date. Incident Number Enter the incident number Exposure Exposure is defined as a FIRE resulting from another fire. If there is no exposure enter 000. If there are exposure fires you will create separate reports for each entity (building, vehicle, etc.) Note: Throughout the report, you will see fields highlighted in yellow. The fields are highlighted to indicate that an entry is required. Data Entry in NFIRS 8

5. After clicking OK in Section A, the window will disappear and the main screen will be the only screen opened. Double click on to open the first module of the report. Figure 5. NFIRS main screen. Data Entry in NFIRS 9

Adding a module The Basic module is automatically created after completing Section A. Additional modules may be required depending on the incident type. For example a 111 Building Fire incident type with no aid given would require the completion of a Fire Module and Structure Fire module. Once the Basic module is complete, the software provides indicators to help users determine which additional modules are required. 1. To add a new module, go to the main screen and select the Add Module tab. A dropdown box will appear and the module required will be highlighted in red. After choosing the highlighted item, the module will automatically open. Data Entry in NFIRS 10

Data Entry in NFIRS 11

Basic module Figure 6. Basic module (Sections B E) Address type Select from a variety of address types such as street address, directions, intersection, and more, by clicking on to retrieve a drop down menu. Address fields Always separate each section of an address. Addresses are separated by number address, street prefix (North, South, etc.), street name, street type (street, road, court, etc.), and street suffix. Each section is separated for mapping purposes for example use with Geographic Information Systems (GIS) systems. City, State, and Zip These are all required fields. Please make sure the data is completed. Incident type Double click on this field to retrieve a menu of codes and descriptions. Always code the incident as the actual situation that is found on arrival. Incidents may not always be the same as what was originally dispatched. Aid Enter the type of aid for the incident. You can double click in this field to choose from the following choices: Aid received A fire department handles an incident within their jurisdiction and is assisted by another fire department. Aid Given A fire department responds to another fire department s jurisdiction. Other Aid Given A fire department covers and responds to another jurisdiction that has no fire department. No Aid Fire department handles incident within its jurisdiction without help from outside fire departments. Data Entry in NFIRS 12

*Aid can either be Mutual or Automatic. Mutual aid is when a fire station requests aid and automatic aid is when there is a pre arranged agreement. An example of mutual aid given is when a station goes out to an incident per another stations request. An example of an automatic aid given is when a fire station goes to incident anytime another fire station is called out due to a pre arranged agreement. Dates and times Enter all required dates and times. Click on the check boxes to the left to populate the date fields to match the alarm time. Control date and time is optional but is required when entering a report for fires. Figure 7. Basic module (Sections F J) Action taken Double click the field to retrieve a menu of actions taken. Common actions: 111 (11) Extinguish, (51) Ventilate,(12) Salvage and overhaul 611 (93) Canceled en route 745 (86) Investigate Resources Enter the resources used in the incident and number of personnel to each resource: Suppression Includes fire fighting resources EMS EMT resources Other Private vehicle, etc. Casualties Enter the amount of FIRE casualties only. Do not enter non fire injuries or deaths. Check if there were no casualties. Detector This field is mandatory when it is a fire incident. Avoid using Unknown. Property Use Double click in this field and a menu will pop up for you to select the options. Enter the Property type in this field. Data Entry in NFIRS 13

Section K1. Entering information in this section is optional but can but can be used to record the individual or company involved in the incident. Figure 8. Basic module (Section K1). Section K2. This section is optional as well but can be used to enter owner information should it be different from the information provided on Section K1. Figure 9. Basic module (Section K2). Data Entry in NFIRS 14

Section L allows you to write a narrative about the incident. Although not required, it is good practice to include a brief description of the incident when possible. Section M is where the Officer in Charge and the member making the report information is entered. Entering this information helps identify who entered the report. Figure 10. Basic module (Sections L M). *Once you are done completing the module. Click to close out the module. Note: Section A and Basic module are required on ALL incident reports. Data Entry in NFIRS 15

Fire Module The Fire module needs to be completed whenever there is a hostile fire. Fill out a Fire module whenever the incident type is 100 112, 120 143, or 160 173. The only time a Fire module is not required is when the fire is contained or it is an aid given incident. Figure 11. Fire module (Sections B D). Area of Fire Double click to open a menu of options. This field describes the area where the fire originated such as a bedroom, kitchen for a structure or an engine area or fuel tank for a vehicle. Heat Source Double click to open a menu of options. This field describes the heat source from the item that was first ignited such as a spark, electrical arcing, or cigarette. Item first ignited Double click to open a menu of options. This field identifies that first material that was ignited by the heat source such as a mattress, electrical wire, or cooking materials. Acres burned Natural vegetation fires such as grass or brush fires reports require you to enter the acres burned. If it is less than an acre you can check Data Entry in NFIRS 16

Figure 12. Fire module (Sections E F). Cause of Ignition Double click to open a menu of options. This field defines the cause of ignition. Choose from the following option: 1 Intentional 2 Unintentional 3 Failure of heat source, including mechanical problems 4 Act of nature such as weather related 5 Cause under investigation 0 Cause, other U Cause undetermined after investigation Contributing factors Double click to open a menu of options. This field defines the factors that caused the fire such as discarded materials, arcing, or natural condition. Human factors Double click to open a menu of options. This section defines human factors that may have contributed to the fire. Choose from the following options: 1 Asleep 2 Possibly impaired by alcohol or drugs 3 Unattended or unsupervised person such as a very young minor or elderly person 4 Possibly mentally disabled, excluding alcohol impairments 5 Physically disabled 6 Multiple persons involved such as gang activity 7 Age was a factor N None Data Entry in NFIRS 17

Section G describes the factors for fire suppression that may have caused the spread or suppression of fires such as a delayed detection of fire. Double click on this field to retrieve a list of code descriptions. Section H must be entered whenever a vehicle fire is involved. Make sure the vehicle make and type are recorded or the report will be invalid and considered incomplete. Figure 13. Fire module (Sections G H). *Once you are done completing the module. Click to close out the module. Note: A Fire module is not required for contained fires such as cooking or trash fires and incidents where aid is given. Data Entry in NFIRS 18

Data Entry in NFIRS 19

Structure Fire Module The structure fire module is necessary for all structure fires. A structure is defined as an assembly of materials forming a construction for occupancy or used to serve a specific purpose. Examples of structures are buildings, open platforms, bridges, roof assemblies over open storage or process areas, tents, air supported structures, and grandstands. Figure 14. Structure fire module (Sections I K). Structure type Double click this field and choose the option that best describes the structure type such as an enclosed building or connective structure (fence, pole). Structure Status Double click this field and choose the structure status such as under construction or occupied and operating. Stories at or above grade Enter the number of stories from the ground and up. Stories below grade Enter the number of stories that are below ground level. Main floor size Although this field is not highlighted in yellow. This information is required. Either complete the total square feet field or enter the length and width of the structure. Fire Origin Double click this field to choose options that identify what floor the fire originated in. Enter negative numbers for a floor that started below grade level. A basement would be 1, while the second floor would be 2. Fire Spread Double click this field to choose the option that best describes the extent of the fire spread such as confined to object of origin, confined to floor of origin, or beyond building of origin. Data Entry in NFIRS 20

Figure 15. Structure Fire module (Sections L M). Sections L M are very important to complete. These sections help to keep track of the presence of smoke detectors in order to evaluate the effectiveness of smoke detector presence and local and state sponsored smoke detector programs. Presence of Detectors Double click on this field to report the presence of detectors. Choose from Present, None present, and Undetermined. Detector type Double click on this field to select the detector type such as smoke, heat, sprinkler or undetermined. Detector Power Supply Double click on this field to choose the type detector power supply such as hardwire or battery. Detector Operation Double click on this field to choose the option that best fits the detector operation. If the option Detector failed to operate was chosen, then you must complete section L6 to define the reason for the failure. Presence of AES Double click on this field to determine the presence of an automatic extinguishing system (AES). *Once you are done completing the module. Click to close out the module. Data Entry in NFIRS 21

Civilian Fire Module The Civilian Fire module should be completed whenever there are FIRE civilian casualties. A fire casualty is defined as a person who is injured or killed as a result of fire, including injuries or deaths from natural or accidental causes sustained while involved in the activities of fire control, attempting to rescue, or escaping from dangers of fires. Non fire related injuries or deaths can be reported in the EMS module. Figure 16. Structure Fire module (Sections B J). Gender Doube click on this field to choose the injured person s gender. Age or Date of Birth Enter the age or date of birth of the injured person. Severity Double click on this field so identify the severity of the injury such as minor, moderate, or severe. Data Entry in NFIRS 22

Sections K P. This section allows you to enter more detailed information about the person s injury. Double click through the fields to retrieve a menu of options to choose from. Figure 17. Civilian Fire Casualty module (Sections K P). *Once you are done completing the module. Click to close out the module. Data Entry in NFIRS 23

Fire Service Casualty Module The Fire Service Casualty module is used to report all injuries, deaths, or exposures to fire service personnel. Report all instances of injuries that involve incident response and nonincident events such as station duty or training. Health exposures such as inhalation or ingestion of a toxic substance should be reported in this module. Figure 18. Fire Service Casualty module (Sections B I). Gender Double click on this field to choose the gender of the injured person. Age Enter the age of the injured person. Severity Double click on this field to choose the severity of the injury such as life threatening, minor, or death. Date and time of Injury Enter the date and time of when the injury occurred. Data Entry in NFIRS 24

Sections J K. This section allows you to enter more detailed information about the person s injury. Double click each field to retrieve a menu of options to choose from. Entering as much information as possible can be helpful in analyzing potential problems. Figure 19. Fire Service Casualty module (Sections J K). *Once you are done completing the module. Click to close out the module. Data Entry in NFIRS 25

Saving the Report Once the user saves the report, it is automatically updated within the database. NFIRS 5.0 automatically checks for errors when the user saves the report. 1. Once all the information in the necessary modules is entered, click the button on the bottom of the module screen. The window will close and the main screen should be open. Data Entry in NFIRS 26

2. If there is information missing or errors in the report, the report may have warnings or critical errors. If there is a critical validation error, a window such as the one below will appear after clicking. 3. Click and another window should pop up listing the critical validation errors. This list provides information identifying the error and its location. You can double click the error and it will take you to the module of where the error is. In this case, a Fire module is required so there is no need to double click on the error. You will need to add the fire module on the main screen. Note: If you cannot read all the words in the columns you can widen the each column from the column header by dragging the vertical line shown in the box below. 4. If you look at the Level column, there are 2 different levels of errors. There are critical and warning errors. The critical errors need to be corrected or else the reports will not be closed out and the incident cannot be counted as being complete. Warnings should be corrected, but the report can be closed out. Data Entry in NFIRS 27

5. When you are done with your corrections, click, to save the report once again. If a critical validation error dialog box appears again, repeat steps until it does not show. If there are warning errors, the dialog box below will show. The same process to correct a critical validation error applies to this situation. If you choose not to correct warning errors, just click. Data Entry in NFIRS 28

Data Entry in NFIRS 29

Delaware Fire Department Identification Codes New Castle County Kent County Sussex County FDID FDID Name FDID FDID Name FDID FDID Name 10100 Wilmington Bureau 30040 Bowers 40070 Bethany Beach of Fire 20009 Aetna 30041 Camden Wyoming 40071 Blades Volunteer 20011 Brandywine Hundred 30042 Carlisle 40072 Bridgeville 20012 Christiana 30043 Cheswold 40073 Dagsboro 20013 Claymont 30044 Citizen s Hose Co. 40074 Delmar 20014 Cranston Heights 30045 Clayton 40075 Ellendale 20015 Delaware City 30046 Dover Robbin s Hose 40076 Frankford 20016 Elsmere 30047 Farmington 40077 Georgetown 20017 Five Points 30048 Felton 40078 Greenwood 20018 Good Will Fire Co. #1 30049 Frederica 40079 Gumboro 20019 Hockessin 30050 Harrington 40080 Indian River 20020 Holloway Terrace 30051 Hartly 40081 Laurel 20021 Mill Creek 30052 Houston 40082 Lewes 20022 Minquadale 30053 Leipsic 40083 Millsboro 20023 Minquas 30054 Little Creek 40084 Millville 20024 Odessa 30055 Magnolia 40085 Milton 20025 Talleyville 30056 Marydel 40086 Rehoboth Beach 20026 Townsend 30057 South Bowers 40087 Seaford 20027 Volunteer Hose 40088 Selbyville 20028 Wilmington Manor 40089 Memorial 20029 Port Penn 40090 Roxana 20030 Belvedere Fire Co. Data Entry in NFIRS 30

Incident Type Codes Data Entry in NFIRS 31

Data Entry in NFIRS 32

Data Entry in NFIRS 33

Data Entry in NFIRS 34

Data Entry in NFIRS 35

Data Entry in NFIRS 36

Data Entry in NFIRS 37

Data Entry in NFIRS 38

Data Entry in NFIRS 39

Data Entry in NFIRS 40

Data Entry in NFIRS 41

Action Taken Codes Data Entry in NFIRS 42

Data Entry in NFIRS 43

Data Entry in NFIRS 44

Data Entry in NFIRS 45