DESIGN CLARIFICATION (DC)



Similar documents
SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

STANDARD FOR NON-FIRE RATED ROLLING DOORS

MODEL HSR-007 Direct Drive Rolling Steel

Architectural Specifications* MODEL HDE

Architectural Specifications MODEL HDXL Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

City of San Diego, CWP Guidelines

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

SECTION FireGard ROLLING FIRE DOORS / SMOKESHIELD FIRE DOORS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

PART 1 GENERAL 1.1 SECTION INCLUDES

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION WINDOW WASHING SYSTEMS

Residential Garage Door Terminology

SECTION HEAT PUMPS

P.A.L. S SPECIFICATIONS

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Packaged Terminal Air Conditioner Wall Sleeve Installation

Mechanical Installation

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

AC Electric Motors best practice

SECTION PREFORMED METAL STANDING SEAM ROOFING

WE-350 Series ¼ Turn Electric Actuator

Preformed Metal Roofing and Siding

SECTION STANDING SEAM METAL ROOFING

3-Part Specification Railing Cable Systems

Phoenix-3W Series One-Way Security Revolving Doors

CLEAR-DIVISIONS CENTERFOLD

DENVER MODEL 30 X 30 SPECIFICATIONS

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

TOP RUNNING SINGLE GIRDER BRIDGE CRANE

Diesel Engine Driven Generators Page 1 of 6

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

SECTION GENERAL PROVISIONS FOR HVAC WORK

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1

Maxi-Stamper. 200 to 1,000 Tons STAMPING OUT DOWNTIME

ADDENDUM #1(BID PACKAGE # 3)

SECTION METAL WALL PANELS

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Office of the State Fire Marshal. Fire Rated Doors

SECTION SERIES 1500 VINYL PATIO DOORS

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

CLEAR-DIVISIONS VARIOFOLD

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

CLEAR-DIVISIONS APERTO

Commercial Gas Furnace Upflow

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

SECTION 1 GENERAL REQUIREMENTS

COLORADO MODEL. 35 x 65 SPECIFICATIONS

SECTION 6. Glass Storefront Doors:

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Installation Instructions For Slider Casement Air Conditioners

1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.

TECHNICAL INFORMATION

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION MORTUARY REFRIGERATORS

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION 807 PUMP STATION REHABILITATION

SECTION MediaStation Model 125 Electric Lateral Files (ELF)

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

Wastewater Capital Projects Management Standard Construction Specification

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

DE Frame with C Series Sidelight

SECTION STORM DRAINAGE SYSTEM

Window Installation Instructions

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

/CHI BUYLINE Rolling Steel. Buyer s Guide THE DOOR TO QUALITY.

SECTION GUARDA SECURITY WINDOW SCREENS

GUIDELINE SPECIFICATIONS

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

Drive shaft, servicing

Reasons for reissue are provided in Section 6, REVISION SUMMARY.

2.9 WINDOW & DOOR BUCKS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

SECTION STANDING SEAM METAL ROOF

Transcription:

DESIGN CLARIFICATION (DC) Owner: Victor Valley Wastewater Reclamation Authority Date: 03/03/2015 Contractor: W M Lyles Carollo Project No.: 8299A.20 Project Name: Subregional WRPs DC No.: 001 DC Title: Overhead Coiling Door Spec/Dwg. Reference: 08332 Authored By: Martin Ramirez CPM Activity Impacted: 2T Information and Reason For Design Clarification 1. The following design clarification has been made to provide a specification for an overhead coiling door that is specified on Volume 6 Hesperia Lift Station and Pipeline Sheet 00-A-02, and as a follow up to RFI 002. Door No. 02 is an overhead steel door that is prefinished by the manufacturer. See attached Specification 08332 Overhead Coiling Doors. 2. Omit Specification 08362 Sectional Overhead Doors as this product is not in use. 3. Electrical Sheets 00-E-02, 00-E-04, 00-E-07 and 00-E-08 have been modified to include the operator for the overhead coiling door. See attachments. If you believe that this Design Clarification will result in a change to the project time or value, please submit a Change Order Request within 14 working days from date created. Signature: Martin Ramirez Date: 03/03/2015 pw://carollo/documents/carollo Internal Projects/Construction Management Group/Sample Project Folder Structure/Project Specific Templates/Design Clarification.doc (A) 1

SECTION 08332 OVERHEAD COILING DOORS PART 1 GENERAL 1.01 SUMMARY A. Section includes: Non-fire resistive overhead coiling doors insulated. 1.02 REFERENCES A. National Electrical Manufacturers Association (NEMA). 1.03 SYSTEM DESCRIPTION A. Design requirements: 1. Compatibility with space and service requirements: a. Doors and equipment items provided shall be compatible with space limitations specified and indicated on the Drawings. b. Make modifications to doors and equipment items necessary to conform with space limitations or with utility services specified for rough-in. c. Provide items complete including all necessary ancillary equipment as may be required for complete and trouble-free operation. 2. Maintenance requirements: For ease of maintenance, provide overhead coiling doors complying with following requirements: a. Provide each door assembly as complete unit produced or supplied by a single manufacturer, including frames, sections, brackets, operating mechanisms, hardware, and all necessary accessories for installation of complete in openings indicated. b. Unless otherwise specified, all doors of particular type throughout the entire project shall be as manufactured or supplied by a single manufacturer. 1.04 SUBMITTALS A. Product data: 1. General: Submit data completely describing products, including rough-in diagrams. 2. Electrical operators: Submit complete manufacturer's data for all components for electric door operators. Show motor size and characteristics. Show manufacturer's verification that motor has been adequately sized for each size and type of door required. Submit electrical schematic diagrams. B. Shop drawings: 1. Drawings showing complete installation details, required clearances, relation to building structure, complete electrical rough-in requirements required for installation of motor operators for doors and for connection of such doors to fire alarm system, referenced to the door mark number. 2. Show location and size of access doors required to perform maintenance on doors and auxiliary equipment. March 2015 08332-1 8229A10 pw://carollo/documents/client/ca/vvwra/8229a20/construction Management/R Specifications/08332 (Final)

C. Samples: Submit samples of finishes for finish selection. D. Quality control submittals: 1. Manufacturer's instructions: a. Installation instructions for each type and size of door, including manufacturer's data, operating instructions, and maintenance data. b. Furnish installer copy of diagrams and installation instructions. E. Contract closeout submittals: 1. Project record documents: a. Operation and maintenance data: Provide manufacturer's operation and maintenance data for each different type of door specified, complete with manufacturer's list of recommended spare parts and their prices, electrical schematic diagrams, and name and address of nearest maintenance organization approved by door manufacturer. b. Warranty: Provide manufacturer's standard warranty. 1.05 QUALITY ASSURANCE A. Regulatory requirements: 1. Wind loading as specified in Section 01614. 2. Seismic requirements for door anchorage and support systems as specified in Section 01612. 3. Provide electrical materials in NEMA Type enclosures as specified. 1.06 DELIVERY, STORAGE, AND HANDLING A. Packing, shipping, and storage: Protect doors during shipment and storage to prevent warping, bending, and corrosion. B. Deliver materials only after proper facilities are available. Provide clean dry surfaces or platform as required and protect from deterioration and foreign matter. 1.07 PROJECT CONDITIONS A. Field measurements: Field verify all opening dimensions and clearances prior to fabricating doors. Fitting doors to openings is the responsibility of the CONTRACTOR. 1.08 SEQUENCING AND SCHEDULING A. Inserts and anchorages: Furnish inserts and anchoring devices which must be set into concrete or built into masonry. Provide setting drawings, templates, and directions for installation of anchorage devices. Coordinate delivery with other work to avoid delay to the Contract. March 2015 08332-2 8229A10 pw://carollo/documents/client/ca/vvwra/8229a20/construction Management/R Specifications/08332 (Final)

PART 2 PRODUCTS 2.01 MANUFACTURED UNITS A. Insulated steel overhead coiling door: 1. Manufacturers: One of the following or equal: a. Overhead Door Corp., Lewisville, TX 75067. b. The Cookson Company, Model Insulated Rolling Door. c. Wayne-Dalton Corp., Kinnear Division, Model Thermo-Tite. Mounting: Face of wall. 2. Operation: As indicated on the Drawings. 3. Curtain: a. Slats: 1) Exterior slat: Minimum 18-gauge galvanized steel, interlocking flatfaced slats, manufacturer's standard size with ends of alternate slats fitted with metal end locks to hold curtain in alignment. 2) Interior slat: Galvanized steel, manufacturer's standard gauge. 3) Insulation: Polyethylene foam yielding a minimum R-value of 6.20. b. Bottom bar: Fitted with 2 equal-sized steel angles minimum 1/8-inch thick, with lift handle and slide bolt at each end. c. Weatherstripping: 1) Bottom bar: Manufacturer's standard vinyl loop-type or solid flexible foam weatherstripping. 2) Door jambs: Manufacturer's standard vinyl extrusion seals. 3) Hood or Lintel: a) Hood: Manufacturer's standard waterproofed canvas baffle. b) Lintel: Manufacturer's standard brush typed. 4) Weatherseal for interior side guide. 4. Guides: Formed of roll formed steel channels and angles or structural angles of sufficient depth to provide a groove of adequate depth on each jamb to hold curtain firmly in guides under design wind pressure. 5. Brackets: Steel plate with permanently sealed ball bearings designed to enclose ends of coil and provide support for counterbalance pipe at each end. 6. Barrel and counterbalance mechanism: Steel pipe of sufficient size to carry door load with maximum deflection of 0.03 inch per foot of opening width and counterbalanced by helical springs, oil tempered torsion type designed with minimum safety factor of 25 percent safety factor, and having cast iron barrel plugs that anchor springs to tension shaft and pipe. 7. Hood: Fabricated minimum 24-gauge galvanized steel, designed to enclose curtain coil and counterbalance mechanism. B. Door operators: 1. Motor operator: Unless otherwise indicated on the Drawings, provide a heavyduty type motor operator. a. High starting torque type motor having sufficient power to operate the load at an average speed of 1 foot per second. b. Totally enclosed, fan cooled, continuous-duty motor, sized to suit door size (1 horsepower minimum), with Class B insulation. c. 480 volt, 3-phase operation. d. Controlled by momentary contact 3-button station marked OPEN, CLOSE, and STOP. As indicated on the Drawings. March 2015 08332-3 8229A10 pw://carollo/documents/client/ca/vvwra/8229a20/construction Management/R Specifications/08332 (Final)

2.02 ACCESSORIES e. Provide automatic screw-type limit switch to break circuit at termination of travel. f. Provide gear reducer consisting of high efficiency worm gearing running in an oil bath and a spring set, solenoid-operated brake designed to hold the load when power is off. g. Provide emergency hand chain operator which does not affect the time of the limit switch, to operate the load in case of power failure. h. Operator to have reversing NEMA Size 1 starter having mechanical and electrical interlocks, properly sized 24-volt control transformer, and other controls necessary for proper operation, completely assembled and wired to a terminal strip to facilitate field wiring of the power source, pushbutton stations, and/or other remote devices. i. Unless otherwise indicated on the Drawings, all electrical material supplied shall be in NEMA 12 enclosures for interior locations. j. Provide safety edge to reverse direction of door if obstruction is encountered. Safety edge to be one of the following or equal: 1) The Cookson Company, Model Edge Detecting System. 2) Wayne-Dalton Corp., Kinnear Division, Model Electric Safety Edge. A. Fasteners: Sizes and types as recommend by reviewed door manufacturer. 2.03 FINISHES A. Slats, hood and bottom bar: 1. Steel: Manufacturer s premium powder coat paint finish. Color as selected by ENGINEER and as approved by OWNER. B. Guides and bracket plates: 1. Steel and galvanized steel: Manufacturer's standard shop prime finish compatible with finish paint system as specified in Section 09960. C. Aluminum: As selected from manufacturer's standard color, factory applied. PART 3 EXECUTION 3.01 EXAMINATION A. Verification of conditions: Examine openings to receive overhead coiling doors and verify: 1. Dimensions and correctness of backing or support conditions. 2. Absence of defects that would adversely affect installation. B. Do not start work until unsatisfactory conditions are corrected. 3.02 PREPARATION A. Verify dimensions and design for each opening. B. Coordinate details with other work supporting or adjoining coiling doors. March 2015 08332-4 8229A10 pw://carollo/documents/client/ca/vvwra/8229a20/construction Management/R Specifications/08332 (Final)

C. Furnish fastening devices as required to mount doors properly. 3.03 INSTALLATION A. Install doors in strict accordance with manufacturer's installation instructions, unless specifically otherwise indicated on the Drawings. B. Install assemblies plumb, square, and level at their proper elevations and in their proper planes. C. Securely anchor assemblies to interior face of openings, in manner that provides full opening clearance, perfectly aligned and adjusted for smooth operation. D. Interface with other products: Separate or isolate dissimilar metals with neoprene gaskets, sleeves, or washers, or with an acceptable coating. 3.04 ADJUSTING A. Verify that door assemblies are securely anchored to structure, guides are perfectly aligned, and doors are adjusted for smooth operation. B. Upon completion of installation, ensure doors are free from warp, twist, or distortion and are lubricated and properly adjusted to operate freely. 3.05 CLEANING A. Thoroughly clean surfaces of grease, oil, and other impurities. B. Replace any damaged or otherwise disfigured doors with new prior to final acceptance. 3.06 DEMONSTRATION A. Provide OWNER's maintenance employees with minimum of 8 hours of maintenance instruction. 3.07 PROTECTION A. Protect installed doors from damage until final acceptance. END OF SECTION March 2015 08332-5 8229A10 pw://carollo/documents/client/ca/vvwra/8229a20/construction Management/R Specifications/08332 (Final)