Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide



Similar documents
Oasis HLB Cartridges and 96-Well Plates

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Purification of reaction mixtures using flash chromatography.

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

Thermo Scientific Chromatography Columns and Consumables Your world of. chromatography

Solid Phase Extraction for Water Analysis. presented by

A Novel Approach to Low Volume Sample Preparation

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

SPE Reference Manual & Users Guide. Reference Manual & Users Guide

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

Basics of SPE Technology & Mechanisms. Pieter Grobler, Sigma-Aldrich RSA

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

General Chromatography

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

PrepTip. Reverse Phase PrepTip User Guide

How To Test For Contamination In Large Volume Water

Sample Preparation for Forensic Toxicology and Clinical Research. Part 1: Sample Preparation Options

PRODUCTS CATALOG. Green Earth. page FORENSICS CLINICAL PHARMA VETERINARY

Guide to Solid Phase Extraction

Sorbents. [ A] [ A] aq. Strong affinity = large K D. Digital chromatography: all-or. or-nothing LC mechanism to extremes K =

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

The basic division explosives for forensic purposes is shown in Fig. 1

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Innovative vs Traditional

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

Opiates in Urine by SAMHSA GC/MS

Sample Preparation Using Solid Phase Extraction

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup

Training Courses 2014 HPLC GC SPE

Optimization of SPE for Analysis of Mandelic Acid as a Biomarker of Exposure to Ethyl Benzene

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

The Essential CHROMacademy Guide. Mobile Phase Optimization Strategies for Reversed Phase HPLC

Click on Table of Contents. Then type desired page number & click OK.

Bulk Materials for Preparative and Process Chromatography

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis

Affi-Prep Protein A Matrix Instruction Manual

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

The Theory of HPLC. Gradient HPLC

Planar Chromatography

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

Gas Chromatography Liner Selection Guide

Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE

LC-MS/MS, the new reference method for mycotoxin analysis

HPLC Troubleshooting Guide

Determination of Mycotoxin Residues by LC MS/MS Featuring Two Alternate Sample Extraction Procedures

Chapter 6. Solution, Acids and Bases

SOLID PHASE EXTRACTION UCT FORENSICS. Green Earth page

Agilent SampliQ Products for SPE. Improve the quality of your SPE so you can improve the quality of your analysis.

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Extraction of Caffeine from Energy Drinks

Determination of Tricyclazole in Water Using Solid Phase Extraction and Liquid Chromatography

Certificate of Analysis

Ion Exchange Determination of Na+ by Displacement and Zn 2+ Using Preconcentration. Reading: Harris pp , 699

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

HiPer Ion Exchange Chromatography Teaching Kit

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

Dionex IonPac AS19-4µm

ORGANIC SAMPLE PREPARATION

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

SiliaPrep. SPE Cartridges and Well Plates

Accelerated Solvent Extraction (ASE ) Sample Preparation Techniques for Food and Animal Feed Samples

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Overview. Purpose. Methods. Results

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Improved Method for the Analysis of 31 Drugs of Abuse in Oral Fluid samples using the Thomson extreme FV by LC-MS/MS

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

CORESTA RECOMMENDED METHOD N 72

Fipronil Analysis By GC/XSD following Post-Extraction Gel Permeation Chromatography Cleanup

Extraction to Injection in a Single Process

The Chemistry of QuEChERS. Quick, Easy, Cheap, Effective, Rugged and Safe Method for Determining Pesticide Residues

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

Biocides main groups

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Structural Analysis of Labeled N-Glycans from Proteins by LC-MS/MS Separated Using a Novel Mixed-Mode Stationary Phase

CHEM 2423 Recrystallization of Benzoic Acid EXPERIMENT 4 - Purification - Recrystallization of Benzoic acid

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Transcription:

chromatography Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide The following guide provides considerations, tips and general guidelines for developing SPE methods using the Thermo Scientific HyperSep family of Solid Phase Extraction (SPE) products. Part of Thermo Fisher Scientific

Considerations for SPE Method Development Determine Appropriate Column Volume The column volume indicated in the reference table within each method represents the maximum volume of sample or solvent that can be applied to the SPE tube or well per aliquot. The most appropriate column volume for a specific method allows for easy sample application and closely matches the necessary volume of wash solvent. Determine the Appropriate Bed Weight The bed weight defines the maximum amount of analyte that a sorbent can retain. Bed weights should be chosen based on the sample size, taking into consideration the approximate amount of contaminants present and the separation mode. For normal and reversed phase modes, typical bed capacity is 1-5% of the bed weight, up to 100 mg solute/g packing for strongly retained compounds. For example, a 500 mg bed weight can retain up to 25 mg of solute mass. For less retained compounds, if the bed weight is too small relative to the sample matrix volume, breakthrough (early elution) during sample loading can occur. For ion exchange sorbents, the number of charged sites available for interaction with the analyte determines the capacity. This ionic capacity of an ion exchange sorbent is given in milliequivalents/gram (meq/g). The mean ionic capacity values range from 0.072 to 0.320 meq/g. The bed weights for the various HyperSep columns and wells are provided in the tables with each method. Solid Phase Extraction Method Tips 1. Do not allow the sorbent to dry between conditioning steps or before sample application. To ensure that columns are properly solvated, apply each solvent immediately after the previous solvent. 2. Prior to elution, fully dried cartridges will ensure optimal analyte recovery. To confirm column dryness, press the sides of the cartridge at the sorbent level at full vacuum. Columns should not feel cool to the touch. If the column feels cool, water is likely to be present and the column needs further drying. 3. Always use fresh NH 4 OH when preparing basic elution solvents. NH 4 OH rapidly loses its strength when exposed to air and may lead to erratic recoveries. Proper elution ph (11-12) is also critical to achieve optimal recovery of basic drugs with high pk a s (i.e., amphetamines, some tricyclics, morphine) when using mixed mode sorbents such as Verify-CX. 4. Condition your column with an appropriate solvent to ensure optimal retentions are achieved. 5. Analytes that are not in their correct ionization state (i.e., neutral or charged) will not effectively bind to the sorbent and may result in erratic recoveries. To avoid, always verify the sample application ph. If using ion exchange, use a mobile phase that will ensure that the analyte is charged. If mechanism is reversed-phase, maximum retention is maintained by ensuring that the mobile phase ph encourages ion suppression. For more technical tips, guides and applications, visit our Chromatography Resource Center at www.thermo.com/columns.

Thermo Scientific HyperSep Reversed Phase/Polar Retention Effect on Graphite Method (Hypercarb) HyperSep SPE Formats HyperSep Hypercarb SPE Columns Bed Weight Volume Pack Size Part Number 50 mg 1 ml 50 60106-303 100 mg 1 ml 30 60106-302 200 mg 3 ml 30 60106-301 500 mg 6 ml 20 60106-402 1 g 6 ml 10 60106-403 2 g 15 ml 10 60106-404 HyperSep-96 Hypercarb Well Plates Bed Weight Volume Pack Size Part Number 10 mg 1 ml 100 Wells 60302-601 25 mg 1 ml 100 Wells 60302-602 50 mg 1 ml 100 Wells 60302-603 10 mg 1 ml 1 Plate 60302-606 25 mg 1 ml 1 Plate 60302-607 50 mg 1 ml 1 Plate 60302-608 1. Analyte Properties Polar, uncharged species can also retain some ionic/charged species 2. Sample Preparation/Application (Polar, aqueous) Add internal standard to the sample if quantification is desired. Optimize sample application by removing particulates if necessary (centrifugation or filtration) and/or diluting viscous matrices with water or buffer to ensure proper ph for desired interactions. This will require some experimentation. 3. Column Conditioning 2-5 column volumes of a strong eluting solvent followed by 2-5 column volumes water. 4. Column Wash Use water or a weak eluting solvent which will wash most interferences from the sorbent without loss of analytes. Wash ph may greatly affect cleanup and/or recovery. 5. Elution Use a strong eluting solvent to elute the analytes of interest. Addition of 0.1% TFA to the solvent will increase its elution strength for polar analytes. Suggested Elution Solvents MeOH THF* Ethyl Acetate* Dichloromethane* Chloroform* Increasing Elution Strength *Elution strength will depend on the nature of the analytes.

Thermo Scientific HyperSep Reversed Phase Method for C18, C8, Phenyl For HyperSep C18, C8, Phenyl SPE Columns C18 C8 Phenyl Bed Weight Volume Pack Size Part Number Part Number Part Number 50 mg 1 ml 100 60108-390 60108-391 60108-516 100 mg 1 ml 100 60108-302 60108-392 60108-386 200 mg 3 ml 50 60108-303 60108-393 60108-387 500 mg 3 ml 50 60108-304 60108-309 60108-388 500 mg 6 ml 30 60108-305 60108-394 60108-389 1 g 6 ml 30 60108-301 60108-427 60108-517 2 g 15 ml 20 60108-701 60108-704 60108-707 5 g 25 ml 20 60108-702 60108-705 60108-708 10 g 75 ml 10 60108-703 60108-706 60108-709 For HyperSep-96 C18, C8, Phenyl Well Plates C18 C8 Phenyl Bed Weight Volume Pack Size Part Number Part Number Part Number 10 mg 1 ml 100 Wells 60300-421 60300-441 60300-681 25 mg 1 ml 100 Wells 60300-422 60300-442 60300-682 50 mg 1 ml 100 Wells 60300-423 60300-443 60300-683 100 mg 1 ml 100 Wells 60300-524 60300-444 60300-684 10 mg 1 ml 1 Plate 60300-425 60300-445 60300-685 25 mg 1 ml 1 Plate 60300-426 60300-446 60300-686 50 mg 1 ml 1 Plate 60300-427 60300-447 60300-687 100 mg 1 ml 1 Plate 60300-428 60300-448 60300-688 1. Analyte Properties Moderately polar to non-polar, uncharged 2. Sample Preparation/Application (Polar, aqueous) Add internal standard to the sample if quantification is desired. Optimize sample application by removing particulates if necessary (centrifugation or filtration) and/or diluting viscous matrices with water or buffer to ensure proper ph for optimum retention. 3. Column Conditioning 2-5 column volumes of a strong solvent such as methanol at low vacuum (-3 inches Hg). Apply deionized or distilled water to remove excess solvent. Momentary high vacuum (5 to 8 inches Hg) may be necessary to restart flow. If the sorbent is accidentally dried, then resolvate and reflush column. 4. Column Wash Use a solvent which will wash most interferences from the sorbent without loss of analyte. Wash ph may greatly affect cleanup and/or recovery. 5. Elution Use a strong eluting solvent which will elute the analytes of interest. Suggested Elution Solvents MeOH Acetonitrile THF Ethyl Acetate Dichloromethane* *If using dichloromethane the sorbent needs be dried by vacuum to remove any traces of water. Increasing Elution Strength

Thermo Scientific HyperSep Normal Phase Method for Silica, Florisil, Aminopropyl For HyperSep Silica, Florisil or Aminopropyl SPE Columns Silica Florisil Aminopropyl Bed Weight Volume Pack Size Part Number Part Number Part Number 50 mg 1 ml 100 60108-390 60108-391 60108-516 50 mg 1 ml 100 60108-409 60108-402 60108-424 100 mg 1 ml 100 60108-317 60108-403 60108-364 200 mg 3 ml 50 60108-410 60108-404 60108-425 500 mg 3 ml 50 60108-315 60108-405 60108-518 500 mg 6 ml 30 60108-411 60108-500 60108-519 1 g 6 ml 30 60108-426 60108-431 60108-432 2 g 15 ml 20 60108-710 60108-735 60108-738 5 g 25 ml 20 60108-711 60108-736 60108-739 10 g 75 ml 10 60108-712 60108-737 60108-740 For HyperSep-96 Silica, Florisil or Aminopropyl Well Plates Silica Florisil Aminopropyl Bed Weight Volume Pack Size Part Number Part Number Part Number 50 mg 1 ml 100 60108-390 60108-391 60108-516 10 mg 1 ml 100 Wells 60300-481 60300-721 60300-501 25 mg 1 ml 100 Wells 60300-482 60300-722 60300-502 50 mg 1 ml 100 Wells 60300-483 60300-723 60300-503 100 mg 1 ml 100 Wells 60300-484 60300-724 60300-504 10 mg 1 ml 1 Plate 60300-485 60300-725 60300-505 25 mg 1 ml 1 Plate 60300-486 60300-726 60300-506 50 mg 1 ml 1 Plate 60300-487 60300-727 60300-507 100 mg 1 ml 1 Plate 60300-488 60300-728 60300-508 1. Analyte Properties Moderately polar to polar compounds 2. Sample Preparation/Application (Non-polar or Moderately Polar Organic Solvent) Add internal standard to the sample if quantification is desired. Optimize sample application by removing particulates if necessary (centrifugation or filtration). 3. Column Conditioning 2-5 column volumes non-polar solvent such as heptane at low vacuum (-3 inches Hg). Release the vacuum or begin flushing immediately upon completion. The more air that passes through the column before sample loading, the less solvated the sorbent will be. 4. Column Wash Use a solvent which will wash most interferences from the sorbent without loss of analyte. 5. Elution Use a more polar solvent (e.g., introduction of more ethyl acetate, acetone or MeOH). Suggested Elution Solvents Heptane Toluene Dichloromethane Acetone Ethyl Acetate MeOH Increasing Elution Strength

Thermo Scientific HyperSep Copolymeric Phase Method for Verify-CX, Verify-AX For HyperSep Verify -CX or Verify-AX SPE Columns Verify-CX Verify-AX Bed Weight Volume Pack Size Part Number Part Number 130 mg 1 ml 100 60108-719 60108-727 300 mg 3 ml 50 60108-720 60108-728 500 mg 3 ml 50 60108-721 60108-729 200 mg 6 ml 50 60108-722 60108-730 500 mg 6 ml 30 60108-723 60108-731 1 g 6 ml 30 60108-724 60108-732 For HyperSep-96 Verify-CX or Verify-AX SPE Well Plates Verify-CX Verify-AX Bed Weight Volume Pack Size Part Number Part Number 10 mg 1 ml 100 Wells 60300-801 60300-809 25 mg 1 ml 100 Wells 60300-802 60300-810 50 mg 1 ml 100 Wells 60300-803 60300-811 100 mg 1 ml 100 Wells 60300-804 60300-812 10 mg 1 ml 1 Pack 60300-805 60300-813 25 mg 1 ml 1 Pack 60300-806 60300-814 50 mg 1 ml 1 Pack 60300-807 60300-815 100 mg 1 ml 1 Pack 60300-808 60300-816 1. Analyte Properties Moderately polar to non-polar and ionized and charged compounds 2. Sample Preparation/Application Add internal standard to the sample if quantification is desired. Optimize sample application by removing particulates if necessary (centrifugation or filtration) and/or diluting viscous matrices with water or buffer to ensure proper ph for optimum retention. Neutral species are unaffected by ph. Charged species may show maximum retention under acidic or basic conditions and method development is required to establish this. 3. Column Conditioning 2-5 column volumes polar solvent such as methanol at low vacuum (-3 inches Hg). Release the vacuum or begin flushing immediately upon completion. The more air that passes through the column before sample loading, the less solvated the sorbent will be. Apply deionized or distilled water to remove excess solvent. Momentary high vacuum (5 to 8 inches Hg) may be necessary to restart flow. If the sorbent is accidentally dried, then resolvate and reflush the column. 4. Column Wash Use water to disrupt the hydrophilic interactions and methanol to disrupt residual hydrophobic and hydrophilic interactions. 5. Elution Use an organic solvent, possibly with some water to elute hydrophobically bound analytes. Then use an aqueous buffer with a ph that would neutralize ionically bound analytes or an aqueous with high ionic strength or a solvent with a counter ion that would bind to a sorbent.

Thermo Scientific HyperSep Ion Exchange Phase Method for SCX, SAX HyperSep SAX & SCX SPE Columns Column SAX SCX Bed Weight Volume (ml) Quantity Part Number Part Number 50 mg 1 100 60108-417 60108-420 100 mg 1 100 60108-418 60108-421 200 mg 3 50 60108-419 60108-422 500 mg 3 50 60108-521 60108-423 500 mg 6 30 60108-360 60108-520 1 g 6 30 60108-434 60108-433 2 g 15 20 60108-713 60108-716 5 g 25 20 60108-714 60108-717 10 g 75 10 60108-715 60108-718 HyperSep-96 SAX Well plates and individual wells Column SAX SCX Bed Weight Volume (ml) Quantity Part Number Part Number 10 1 100 Wells 60300-561 60300-581 25 1 100 Wells 60300-562 60300-582 50 1 100 Wells 60300-563 60300-583 100 1 100 Wells 60300-564 60300-584 10 1 1 Plate 60300-565 60300-585 25 1 1 Plate 60300-566 60300-586 50 1 1 Plate 60300-567 60300-587 100 1 1 Plate 60300-568 60300-588 1. Analyte Properties Ionized and charged particles 2. Sample Preparation/Application Add internal standard to the sample if quantification is desired. Optimize sample application by removing particulates if necessary (centrifugation or filtration) and/or diluting viscous matrices with water or buffer to ensure proper ph for optimum retention. Neutral species are unaffected by ph. Charged species may show maximum retention under acidic or basic conditions and method development is required to establish this. 3. Column Conditioning 2-5 column volumes polar solvent such as methanol at low vacuum (-3 inches Hg). Release the vacuum or begin flushing immediately upon completion. The more air that passes through the column before sample loading, the less solvated the sorbent will be. Apply a low ionic strength buffer after flushing to ensure that the sorbent ph is optimal for the sorbent analyte interaction desired. Follow guidelines concerning pk a, ph and ionic binding to ensure optimal retentions. Use the same vacuum guidelines as used for flushing. 4. Column Wash Use an organic solvent or aqueous buffer at a ph that allows the ion to remain charged (2 ph units from the relevant pk a of your analyte and sorbent). 5. Elution Use an aqueous buffer with a ph that would neutralize ionically bound analytes or an aqueous with high ionic strength or a solvent with a counter ion that would bind to a sorbent.

Visit the Chromatography Resource Center at: www.thermo.com/columns The Chromatography Resource Center contains numerous technical resources that can help you improve your separations. An Applications Library with approximately 400 applications for HPLC, GC and SPE, helping you refine conditions Column selection and cross-reference tools to ensure the correct tool Interactive troubleshooting tools, with an e-mail connection to our columns technical support teams Tips and FAQs you can rely on daily Technical Library with recent scientific posters, application notes and guides for download or by mail ISO 9001:2000 FM 76231 Thermo Electron Corporation, Bellefonte, PA is ISO Certified. For Technical Support: North America T +1 800 437 2999 E techsupport.analyze.us@thermofisher.com Africa, Asia, Europe, Latin America and Middle East T +44 (0) 1928 581000 E techsupport.columns@thermofisher.com Thermo Hypersil Ltd., Runcorn, UK is ISO Certified. 2007 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. TG20317_E 02/07M