PSIM Tutorial. How to Use Solar Module Physical Model. - 1 - Powersim Inc. www.powersimtech.com



Similar documents
High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules

Solar Cell Parameters and Equivalent Circuit

DARK CURRENT-VOLTAGE MEASUREMENTS ON PHOTOVOLTAIC MODULES AS A DIAGNOSTIC OR MANUFACTURING TOOL

As we look at the PV array in a PV system, we find that many. by John Wiles

Your Sharp system will be supplied with one of the following sets of panels:

Solar Energy Discovery Lab

Solar Power Analysis Based On Light Intensity

Fox-2 MPPT Unit Testing

T :: T :: T ::

SIMULATIONS OF PARALLEL RESONANT CIRCUIT POWER ELECTRONICS COLORADO STATE UNIVERSITY

FUNDAMENTAL PROPERTIES OF SOLAR CELLS

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Application Note: String sizing Conext CL Series

LN240(30)P-3-xxx ( W poly)

DC To DC Converter in Maximum Power Point Tracker

AC : APPLIED MODELING OF SOLAR CELLS

Plots, Curve-Fitting, and Data Modeling in Microsoft Excel

Lecture 3: DC Analysis of Diode Circuits.

Physics 623 Transistor Characteristics and Single Transistor Amplifier Sept. 13, 2006

However, industrial applications may utilize a relay, which short-circuits the ICL path after the inrush sequence.

SIMPLE TECHNIQUES TO IMPROVE SOLAR PANEL EFFICIENCY USING A MICROCONTROLLER OR SOC

Transistor Characteristics and Single Transistor Amplifier Sept. 8, 1997

Fundamentals of Photovoltaic solar technology For Battery Powered applications

PHOTOVOLTAIC SYSTEMS. Alessandro Massi Pavan

Modeling of Photovoltaic Cell Using Free Software Application for Training and Design Circuit in Photovoltaic Solar Energy

Performance of Single Crystal Silicon Photovoltaic Module in Bruneian Climate

Photovoltaic System Overcurrent Protection

Input and Output Capacitor Selection

13.10: How Series and Parallel Circuits Differ pg. 571

Project 2B Building a Solar Cell (2): Solar Cell Performance

BJT Characteristics and Amplifiers

Help on the Embedded Software Block

VJ 6040 Mobile Digital TV UHF Antenna Evaluation Board

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

Photovoltaic (PV) Energy as Recharge Source for Portable Devices such as Mobile Phones

Design of a Photovoltaic Data Monitoring System and Performance Analysis of the 56 kw the Murdoch University Library Photovoltaic System

AC Transport constant current vs. low impedance modes

DC-DC high gain converter applied to renewable energy with new proposed to MPPT search

SOLAR MODULES SOLARFLEX Polska Grupa Inwestycje Ekologiczne Sp. z o.o. PRODUCTS LINE of SOLARFLEX Price list

Solutions for. Solar Cell and Module Testing. How to decrease costs and increase flexibility in a rapidly changing test environment.

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law

= (0.400 A) (4.80 V) = 1.92 W = (0.400 A) (7.20 V) = 2.88 W

Curcuits and Differential Equaitons

High Power Programmable DC Power Supplies PVS Series

Effect of Ambient Conditions on Thermal Properties of Photovoltaic Cells: Crystalline and Amorphous Silicon

Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI

Analysis and Reporting of I-V Curve Data from Large PV Arrays

ELG4126: Photovoltaic Materials. Based Partially on Renewable and Efficient Electric Power System, Gilbert M. Masters, Wiely

MODEL 62000H-S SERIES

O&M Service for Megasolar Power Plants and Precise Monitoring Techniques for PV Modules

Lab Report No.1 // Diodes: A Regulated DC Power Supply Omar X. Avelar Omar de la Mora Diego I. Romero

Diodes and Transistors

Solar Cell Bypass Diodes in Silicon Crystalline Photovoltaic Panels

Basic Understanding of IEC Standard Testing For Photovoltaic Panels

HIGH FREQUENCY TRANSFORMER WITH TRANSFORMER SWITCHOVER

Simulation of Photovoltaic generator Connected To a Grid

Unit 7: Electrical devices LO2: Understand electrical sensors and actuators Sensors temperature the thermistor

PID - The Problem and How to Solve It

Design qualification and type approval of PV modules

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs

Maximum power point tracking techniques for solar water pumping systems

Photovoltaic String Inverters and Shade-Tolerant Maximum Power Point Tracking: Toward Optimal Harvest Efficiency and Maximum ROI

Lab 1: DC Circuits. Student 1, Partner : Student 2, student2@ufl.edu

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008

Tutorial on Using Excel Solver to Analyze Spin-Lattice Relaxation Time Data

Inductors in AC Circuits

MIDNITE SOLAR AND SOLAR WASHINGTON

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Switch Mode Power Supply Topologies

AN-6005 Synchronous buck MOSFET loss calculations with Excel model

K.Vijaya Bhaskar,Asst. Professor Dept. of Electrical & Electronics Engineering

KADUNA CLINICS SOLAR SYSTEMS PERFORMANCE TESTING

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Electronics I - Laboratory 1 Diode I/V Characteristics

Comparison of Solar Panel Models for Grid Integrations Studies: Harmonics and Voltage Disturbances

SOLAR PHOTOVOLTAIC ENERGY GENERATION AND CONVERSION FROM DEVICES TO GRID INTEGRATION HUIYING ZHENG SHUHUI LI, COMMITTEE CHAIR

Arti cial neural Network-Based modeling and monitoring of photovoltaic generator

THE BREADBOARD; DC POWER SUPPLY; RESISTANCE OF METERS; NODE VOLTAGES AND EQUIVALENT RESISTANCE; THÉVENIN EQUIVALENT CIRCUIT

Series AMLDL-Z Up to 1000mA LED Driver

Real Time Selective Harmonic Minimization for Multilevel Inverters Connected to Solar Panels Using Artificial Neural Network Angle Generation

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

Impedance Matching of Filters with the MSA Sam Wetterlin 2/11/11

Using Microsoft Excel to Plot and Analyze Kinetic Data

PHOTOVOLTAIC ARRAY WIRING HANDBOOK FOR STANDARD NOMINAL 6, 12, 24, AND 48 VOLT SYSTEMS. (for SX-60 series or smaller and MSX-120 solar modules)

Understanding Power Impedance Supply for Optimum Decoupling

Photovoltaic Power: Science and Technology Fundamentals

BIASING OF CONSTANT CURRENT MMIC AMPLIFIERS (e.g., ERA SERIES) (AN )

Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

Renewable Energy. Solar Power. Courseware Sample F0

Multi-port DC-DC Topology for Renewable Energy Systems using Soft Computing Techniques

Experiment 6 ~ Joule Heating of a Resistor

University of California, Berkeley Department of Electrical Engineering and Computer Sciences EE 105: Microelectronic Devices and Circuits

How To Use Multiisim On A Computer Or A Circuit Design Suite 10.0 (Aero)

Current Monitoring Kit QUICK START GUIDE

Chip Diode Application Note

Lab #9: AC Steady State Analysis

Electronics. Discrete assembly of an operational amplifier as a transistor circuit. LD Physics Leaflets P

Transcription:

PSIM Tutorial How to Use Solar Module Physical Model - 1 - Powersim Inc.

This tutorial describes how to use the solar module physical model. The physical model of the solar module can take into account variations of the light intensity and ambient temperature. However, it requires many parameter inputs. Some of the parameters can be obtained from manufacturer datasheets, while other parameters need to be obtained by trial-and-error. In order to make it easier for users to define parameters for a particular solar module, a utility tool called Solar Module (physical model) is provided in the PSIM s Utility menu. This tutorial describes how to use this tool through examples. The solar module physical model has the following parameters: Number of Cells Ns: Number of solar cells in series in a solar module Standard Light Intensity S0: Light intensity under standard test conditions, in W/m 2. This value is normally 1000 W/m 2. Ref. Temperature Tref: Temperature under standard test conditions, in o C. Series Resistance Rs: Series resistance of each solar cell, in Ohm. Shunt Resistance Rsh: Shunt resistance of each solar cell, in Ohm Short Circuit Current Isc0: Short circuit current of the solar module at the reference temperature, in A. Saturation Current Is0: Saturation current of the diode in the model, in A Band Energy Eg: Band energy of each solar cell, in ev. Ideality Factor A: Ideality factor, also called emission coefficient, of the diode in the model. Temperature Coefficient Ct: Temperature coefficient, in A/K. Coefficient Ks: Coefficient that defines how light intensity affects the solar cell temperature The solar module MSX-60 from BP Solar is used to illustrate how to use the utility tool to obtain the model parameters. The process involves the following steps: Enter the information from the datasheet; Make an initial guess of certain parameters; Obtain the I-v and P-v curves, and the maximum power point. Compare with the datasheet and experimental data for different operating conditions, and fine tune the parameters. 1. Entering Datasheet Information The figure below shows the manufacturer datasheet image, and the region of the utility tool dialog window related to manufacturer datasheet. All the information required by this region, except the dv/di value at Voc, can be read directly from the datasheet, as highlighted by the red rectangles. In the datasheet, the temperature coefficient of the open-circuit voltage is expressed in V/ o C. It needs to be converted to %/ o C for the utility tool as: - 80mV/ o C = -0.08/21.1 / o C = -0.38 %/ o C. - 6 - Powersim Inc.

Manufacturer datasheet The value dv/di (slope) at Voc refers to the dv/di slope at the open-circuit voltage Voc of 21.1V. From the datasheet I-V characteristics, by reading the values from the graph (marked in red dotted lines), we can calculate approximately the slope as: dv di = ΔV Δi = 0.34 0.5 = 0.68 If the I-V curve is not available on the datasheet, leave the dv/di value at 0. 2. Estimating Parameter Values Eg, A, Rsh, and Ks These four parameters are normally not provided on the datasheet, and one needs to come up with a good initial guess, or obtain them from manufacturers: band energy Eg, ideality factor A, shunt resistance Rsh, and coefficient Ks. - 7 - Powersim Inc.

A good initial guess of the band energy Eg is around 1.12 ev for crystalline silicon, and around 2 ev for amorphous silicon. A good initial guess of the ideality factor A is around 2 for crystalline silicon, and is less than 2 for amorphous silicon. A good initial guess of the shunt resistance Rsh is several thousand Ohm. If unknown, the initial value of the coefficient Ks can be set to 0. In this example, we set: Eg = 1.12 A = 1.2 Rsh = 1000 Ks = 0. 3. Calculating Parameter Values Rs, Isc0, Is0, and Ct Based on the datasheet information and the initial guess of Eg, A, Rsh, and Ks, the rest of the parameters (series resistance Rs, short circuit current Isc0, saturation current Is0, and temperature coefficient Ct) can be calculated by clicking on the Calculate Parameters button. The following values will be obtained: Rs = 0.0108 Isc0 = 3.8 Is0 = 2.16e-8 Ct = 0.00247 Note that the calculation is approximate, and provides only the base values. Users should feel free to adjust these parameters to fit the calculated I-V curve to the datasheet curve or the experimental results. 4. Fine Tuning the Parameters Under give operating conditions of the light intensity S and the ambient temperature Ta, one can obtain the I-V and P-V curves by clicking on the Calculate I-V Curve button. The calculated maximum power point will also be calculated. If we define S = 1000 W/m 2 and Ta = 25 o C, we can obtain the maximum power point as: Pmax = 59.27 W, Vmax = 16.73 V, and Imax = 3.54 A. Both the maximum power and the voltage at the maximum power are lower than the datasheet values of 60 W and 17.1 V. One should adjust the parameters Eg, A, Rsh, Ks, Rs, Is0, and Ct to obtain a better fit. In this example, if we change the series resistance Rs to 0.008 Ohm, the calculated maximum power point is: Pmax = 60.54 W, Vmax = 17.04V, and Imax = 3.55 A, which is closer to the datasheet values. The final parameter values and the I-V and P-V curves are shown below. - 8 - Powersim Inc.

Many iterations and trial-and-error may be needed to obtain a good fit to the datasheet or experimental data. After the parameters are finalized, click on the Copy PSIM Parameters button to copy the model parameters to the PSIM schematic. To save the datasheet and parameter values to a text file to later use, click on the Save button, and save it to a file (for example Solarex MSX-60.txt ). To load the data of a specific solar module back, click on the Load button. 5. Multiple Modules in Series Often several identical solar modules are connected in series to form a solar array. One can use a solar module block to model the solar array. The figure below shows 2 solar modules Solarex MSX-60 connected in series, and a combined block that models 2 modules. The model parameters of the combined block is the same as for a single solar module, except that the number of cells Ns is 2 times of the single solar module value. Note that when multiple modules are connected in series, a bypass diode is needed across each module if the light intensity and ambient temperature inputs are different. Also, a very small capacitor (in this case 30 nf) is needed across each module for numerical convergence. - 9 - Powersim Inc.

2 modules in series A combined block representing 2 modules in i To plot the I-V curve of the combined block, change the following quantities from the single module value: Number of Cells Ns * 2 Maximum Power Pmax * 2 Voltage at Pmax * 2 Open-Circuit Voltage Voc * 2 dv/di (slope) at Voc * 2 The figure below shows the solar module utility tool dialog for a single module and a combined block. The parameter inputs in the red boxes highlight the differences. - 10 - Powersim Inc.

Data of one single solar module Data of the combined block 6. Multiple Modules in Parallel In other cases, several identical solar modules are connected in parallel to form a solar array. One can use a solar module block to model the solar array. The figure below shows 2 solar modules Solarex MSX-60 connected in parallel, and a combined block that models 2 modules. Some of the parameters of the combined block are different as compared to the parameters of a single solar module, as highlighted in the red boxes below. 2 modules in parallel A combined block representing 2 modules in parallel - 11 - Powersim Inc.

To plot the I-V curve of the combined block, change the following quantities from the single module values: Maximum Power Pmax * 2 Current at Pmax * 2 Short-Circuit Current Isc * 2 dv/di (slope) at Voc * 0.5 Series Resistance Rs * 0.5 Short Circuit Current Isc0 * 2 Saturation Current Is0 * 2 Temperature Coefficient Ct * 2 The figure below shows the solar module utility tool dialog for a single module and a combined block. The parameter inputs in the red boxes highlight the differences. Data of one single solar module Data of the combined block - 12 - Powersim Inc.