Problem / Solution. The problem:

Similar documents
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Power Supplies 3. SDN-P DIN Rail Series

ACS-30-EU-EMDR-10-MOD

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

BB800 Off-Grid Solar System

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Duct Humidity Transmitter

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Introduction. Page 2 / 9

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

AZ420 MINIATURE GENERAL PURPOSE RELAY

WD-AMX Water Detection Controllers

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Charge Regulator SCR 12 Marine

SINEAX U553 Transducer for AC Voltage

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

SMART SENSOR COLLECTION

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

RY2 miniature industrial relays

Contents. Document information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

UMEC International Corporation

CO2 Alarm. Operation. Application

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Water Leak Detection System

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Quick Connect. quick - simple - efficient.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

650W Single Output Power Supply

Electronic Control Devices The European Product Catalogue 2007

TC-9102 Series Surface Mount Temperature Controllers

RM4TG20 three-phase network control relay RM4-T - range V

DS 600. A contact free flux gate based current measurement sensor 600A rms

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Split Controller. User Manual SM-SS-F 2009/01/04

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Solid-State Timer H3G

Proportional pressure regulators VPPE

Capacitive Prox E2K-X

ADM1TE 5/30A DIN rail single phase two wire energy meter

Series 510 Submersible Level Transmitters

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

4 Posiflow Proportional Solenoid Valves

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

R.C.C.B. s two-pole LEXIC

User s Manual Before using the inverter, you need to read and save the safety instructions.

Electronic Control Devices The European Product Catalogue 2007

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MLC TM Maximum Productivity and Versatility for Control without Compromise!

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

SECTION VIDEO SURVEILLANCE SYSTEMS INFRASTRUCTURE

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Free electricity for your home, offices or factory with solar PV panels

HMI display Installation Guide

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Drayton Digistat +2RF/+3RF

How To Read A Pipe From A Sensor

ALARMLINE ANALOGUE Linear Heat Detection System

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

T7079A,B Solid State Remote Temperature Controllers

Three-phase monitoring relay CM-PFE

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

3-phase, bidirectional energy meter

A1000 Cheat Sheet (Open Loop Vector)

Instructions for Safe Use

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Solid-State Relays. Series Included. Solid-State Relays SIR SLR NLF PHS Series PHS...148

FP2 Relay. The Best Relaytion

Model: DC-A2IO Advanced HVAC Controller

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

US Installation Manual Smappee Monitor

Transcription:

Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is green, renewable energy and which doesn't release any harmful pollutants. People want to reduce their carbon footprint and reduce their gas and electricity bills, they can achieve this through Solar PV technology. The problem: At the moment any surplus energy produced from the Solar PV system, people either sell back to the grid (for shocking rates, so it s barely worth it) or they use it around the house to try and decrease other utility bills. More and more people are getting Solar PV systems installed and instead of selling the extra energy back to the grid, they use it to heat water and as a result lower their gas bill. The surplus energy generated from the solar panel is used by the immersion heater to heat the water. Most households have been fitted with a 3kW immersion heater; it may not be possible for the Solar PV system to generate that much spare energy. 3kW is quite high and therefore may over load the spare energy available. Currently the only option for homeowners with high kw immersion heaters is to purchase a 1kW or 2kW immersion heater and hire an electrician and plumber to remove and replace their existing one. However, this can be very time consuming and very expensive and this is where homeowners may consider just selling the surplus energy back to the grid. The solution: Here at Amelec Instruments, we ve designed and created an ECO 2 Water Heating System. The package includes an ACT-200, an AGS1133 Intelligent Solar Switch and an APR-3 Power Reducer. The ACT-200 is a sensor which provides the AGS1133 Trip Amplifier with an accurate measurement of the power generated from the solar panel. The AGS1133 Intelligent Solar Switch monitors the household power; and recognises if the power is being imported or exported. It then automatically switches ON the immersion heater only when enough spare power is being exported. The intelligent switch will also recognise if there is a change in weather conditions and/or other appliances are switched ON around the house, it will then turn off the immersion heater, ensuring the water is only heated using the power generated by your PV system. The unit is fully tested and ready setup, so NO site programming or setting up, simply fit and forget. Through one of our APR-3 Power Reducer units, the immersion heater runs at halve the kw and gently heats the water. So a 3kW immersion heater becomes 1.5kW and 2kW immersion heater becomes 1kW. Over a day, you will get a full tank of hot water for free. Our ECO 2 Water Heating System allows homeowners to use surplus energy generated by the Solar PV system to heat water for free. Over the period of a year, our system can significantly reduce the gas bill. All products are designed and manufactured in our factory in Milton Keynes, England. They are easy to install and very cost effective.

About Us Originally formed in February 1975, AMELEC remains a wholly owned British manufacturing company. Over the past 35 years we have supplied a wide range of tried and tested signal conditioning equipment to many industries within both the public and Private sectors and have gained in-depth understanding of product application. We therefore know what works and what does not. Using this knowledge we are able to ensure the products we offer to our customers are fit for purpose and best value for money. Our design, manufacturing and test facilities are all in Milton Keynes, England. We have well established and trustworthy business relationships with sub-contractors, manufacturers and suppliers both here in the UK and worldwide. Dependent upon our customers requirements, we are able to respond to their wants and needs quickly and efficiently, ensuring the best return on their investment. Our design & everyday application engineering principles used in the instruments are based on well-tried linear operational amplifier circuitry, proven in use for over thirty years. Each instrument can be considered as a number of functional blocks assembled together to produce a specific control function. By combining these functional blocks together we have produced a comprehensive range of Trip Amplifiers, Transmitters, Signal Converters / Isolators, Signal Splitters/Boosters, combined Trip Transmitters, Arithmetic (Add / Subtract / Select / Multiply / Divide) units, Power Supplies, Strain Gauge, Frequency & AC I/V Transducers, Transformers as well as HART compatible units. A wide range of these instruments have no time dependent or microprocessor circuitry and have been independently accessed & verified for use in SIL 1, 2 or 3 (IEC61508) rated safety systems/loops. Our facility in Milton Keynes operates in accordance with UKAS certified ISO 9001:2008 quality system. Any outsourced production and services are from approved organisations holding ISO 9001:2008 Quality Management certification. We have been awarded 100% score in quality accreditation by the Achilles-UVDB verify scheme. Instrumentation manufactured by Amelec Instruments is covered by up to 10 year warranty. To confirm that the instruments are compliant with the latest standards, AMELEC have submitted a range of instruments with all the various circuit blocks in them to the test houses. The reference / standards used at the test houses have been:- the CEGB s EES1989, the BS6667, IEC801. We offer RFI Protection to the IEC61000-4-3 standard. Our vast client base is spread across all process industry sectors; originally to the likes of the CEGB, BNFL, GEC, British Gas, ICI, BP & Shell, today AMELEC continues to supply quality instrumentation to the Nuclear, Power Generation, Rail, Oil & Gas, Chemical, Pharmaceutical, Petrochem, Utilities, Food & Brewery sectors, as well as to many other general manufacturing industries & the Water Authorities throughout. Here are some of our clients:

ACT-200 Split core CT for easy Installation Non intrusive monitoring 1 year guarantee as standard CE compliant Low clamped Isolated O/P - Connect directly to PLC Mounting - Clip APPLICATION Motor / Heating element current monitoring. AC current signal conditioning. TECHNICAL SPECIFICATION INPUT Current can be specified in the range of: 0-5A, 0-10A, 0 20A, 0 50A, 0 100A. Other intermediate ranges available on request. Bandwidth: 30 to 400Hz nominal, other ranges available. OUTPUT Current = 2000:1 Typical range 0-20A = 0-10mA Voltage = Any range can be specified up to 25Vac. Typical range 0-50A = 0-1Vac Linearity: < ±1% Accuracy: < ±2% Response time: Typically < 100mS Protection Isolation 2500V RMS. Input / Output / Case Input over range up to 200% continuous. Enclosure: ABS (UL 94V-0) / IP20 ENVIROMENTAL CONDITION Storage temperature: - 10 to +70 C Operating Ambient: -10 to +50 C Relative Humidity: 20 to 95% RH Temp Coefficient: < 300ppm MOUNTING Mounting: Clip Weight < 100g Installation: CAT II Issue 1 2011

AGS1133 Intelligent Solar Switch Single or Dual CT operation 1 year guarantee as standard CE & RoHS compliant British Design & Manufacture TYPICAL APPLICATION Solar / Wind Power TECHNICAL SPECIFICATION FUNCTION Monitors the household power; recognises if the power is being imported or Exported and only switches ON the immersion heater when enough spare power is being available from the solar system. INPUT From Amelec ACT-200 CT (See datasheet for ACT-200 for further details). Frequency: 50Hz nominal, other ranges available. Calibration Range: 5 to 100% / Average RMS. OUTPUT 1 x SPCO contacts, rated at 250VAC, 16A, 3000VA resistive. (Relay Normally De-energised, Energised on trip) Fail safe. CONTROLS SP 1: 15 turn potentiometer to set spare capacity threshold point in the range of 0.1 to 5kW. Setpoint can be monitored on Test-SP1 with ref to Test-0V. using DVM. 0-1V represent 0-5kW. Important: When setting SP1 potentiometer, ensure the small phase LED is RED. (Default factory setting is 1.5kW). INDICATOR Power ON: 5MM LED, GREEN. Relay status: 5MM LED, Red = ON PHASE DETECTION IMPORT = 3MM LED, GREEN EXPORT =3MM LED, RED PERFORMANCE Accuracy: < 1% Trip settability: better than ±1% Trip repeatability: better than ±1% Response time: Typically < 400mS Power consumption: <3VA MOUNTING AND FIXING This product is designed to be fixed inside EUROPA - ECW06 Enclosure Dimension: 160W x 212H x 115D. Fixing Centre - 145mm PROTECTION Isolation 1000V RMS. Inputs/Contacts/Supply/Earth Internal Fuse. Failsafe Relay loss of power Input over range up to typically 200%. ENVIROMENTAL CONDITION Storage temperature: - 40 to +70 C Operating Ambient: -15 to +55 C Relative Humidity: 5 to 95% RH To reset latched trip manually, apply a short to - SAFETY NOTE: 1. Potentially High dangerous voltages and therefore shall only be installed by qualified person. 2. Connect the equipment according to current IEE regulations and separate all Wiring according to IEC1010. 3. Make sure all screw terminals are tight before you switch the equipment on. 4. Don t touch any circuitry after you have connected the equipment, because there may be lethal voltages on the circuit board or connector terminals We designed this equipment for Pollution-Degree 2 environments only. This means you must install it in a clean, dry environment. Issue 3

APR-3 Power Reducer Power reducer (halve the power) Easy installation 1 year guarantee as standard CE & RoHS compliant British Design & Manufacture TYPICAL APPLICATION Immersion Heater. TECHNICAL SPECIFICATION Units is designed to halve the power. E.g. 3KW load reduced to 1.5KW. INPUT 110 / 240Vac May be suitable for other supply voltages up to 600Vac. Frequency: 50Hz +/- 10% nominal, other ranges available. OUTPUT LOAD 1 to 3 KW ( up to 13A max) PROTECTION Isolation between. LIVE / Case / Heat sink plate Input over range: 20A (non repetitive) Enclosure: IP65 ENVIROMENTAL CONDITION Storage temperature: - 20 to +70 C Operating Ambient: -20 to +70 C Relative Humidity: 20 to 95% RH MOUNTING & DIMENSION Dimension : W44 x H90 x D24 (mm) Wire : 300mm Length rated 20A max. Mounting hole centre: 66mm (2 x 4.2mm hole dia) Weight < 125g Installation: CAT II SAFETY NOTE: 1. Potentially High dangerous voltages and therefore shall only be installed by qualified person. 2. Before wiring to any power source, the unit should be fixed to surface and Earthed. 3. This product could run hot at 100% load and therefore shall be fixed to a flat surface, inside a suitable metal enclosure to help dissipate the heat. 4. Live In from power supply shall be suitably fused to prevent prolonged over load current causing damage. 5. If the unit fails, it should cut power to the load. This unit is not repairable and therefore should be replaced. WIRING Connect the equipment according to current IEE regulations and separate all Wiring according to IEC1010. Issue 3

ECO 2 SYSTEM WIRING DIAGRAM * Only fit power reducer if required otherwise connect N/O direct to immersion heater. Important: The above diagram is for general guidance only, this may change depending on site situation and therefore Connect the equipment according to current IEE regulations and separate all Wiring according to IEC1010.