MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003



Similar documents
Transformer Bushings for GIS

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

An Overview of Lapp Insulator High Voltage Bushing Design

CABLE ACCESSORIES kv

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

EDITION 2012 CABLE SYSTEMS

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

Metal Clad Indoor Instrument Transformer for Plug-In Systems

FAQs-Main switchboard design criteria

A Study of a MV Cable Joint

Presentation of the France Transfo factories

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

SECTION DRY-TYPE TRANSFORMERS

a Nexans company Catalogue 2014

The Intelligent AX1 Switchgear for Medium Voltage

Capacitor Voltage Transformer. Answers for energy.

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Power transformers. Special transformers Railway

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

UGVCL/SP/591/11KV HT AB CABLE

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Transmission Silicone Insulators Line Post 69 kv to 161 kv

Micalastic insulation for high voltage hydro generators

Respecting the environment

08. SEK IDC CONNECTORS

Directory chapter 04

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

PV module safety qualification according to IEC 61730:2004 EN 61730:2007

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Analytical Report RF high voltage cable accessories market

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

High Voltage Cable Systems

Unified requirements for systems with voltages above 1 kv up to 15 kv

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

A S Y N C H R O N O U S M O T O R S

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Subject: Technology Collaboration for Resin Impregnated Paper (RIP) Bushings

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

PTC-Resistor Temperature-Sensors MINIKA to DIN and DIN

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Adaption of Cable Accessories for Onshore and Offshore Substation

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

SMA Interface Mating Dimensions (Per MIL-STD-348)

This section applies to the design and installation of transformers.

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

World Leader in HV Testing Technology

a Nexans company Catalogue 2013

UFES Active protection for switchgear

Power Plant Electrical Distribution Systems

CAS 36 Ring Main Unit

Securing your electrical installations Prisma,

Fault location on power cables. Fault location on power cables

Z-TRAUQ INC. Tel.: (450) Fax: (450)

New Arc Resistant, Compact Metal Clad Switchgear: Meeting ANSI / UL Design Challenges By Ashok Kulkarni and Predrag Milovac

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

How To Build A Low Voltage Capacitor Lvcp

Gulf Cable & Electrical Ind. Co.

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

EFFICIENT ELECTRICAL ENERGY TRANSMISSION AND DISTRIBUTION INTERNATIONAL ELECTROTECHNICAL COMMISSION

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

KSC Series Sealed Tact Switch for SMT

WIRE AND CABLE ENGINEERING GUIDE

Mini USB and USB 2.0-IP67 Connector System

ACCESSORIES FOR HV CABLES WITH EXTRUDED INSULATION

Development of a 500-kV DC XLPE Cable System

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Medium Voltage Joints & Terminations

SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS

F05D Meeting on Damped AC Voltage Testing

INTERNATIONAL STANDARD

APPLICATION ORIENTED DESIGN OF CABLES

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Medium voltage product. Instrument transformers for indoor applications Product overview

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Excerpts from the Canadian National Building Code (NBC)

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Transcription:

MiCAFIL 1 RIP Technology Z. Zic 09/2003

)XQFWLRQRI+LJK9ROWDJH%XVKLQJ Uncontrolled (natural) electrical field Capacity-controlled electrical field

%XVKLQJV0DLQ,QVXODWLRQ6\VWHPV 7\SH 0DLQ,QVXODWLRQ +RXVLQJFRYHU 2LOH[SDQVLRQ FKDPEHU O I I P Oil Oil Impregnated Impregnated Paper Paper paper, paper, oil oil impregn. impregn. yes, yes, on on both both sides sides yes yes R B P Resin Resin Bonded Bonded Paper Paper paper, paper, resin resin bonded bonded no no no no R I I P Resin Resin Impregnated Impregnated Paper Paper paper, paper, resin resin impreg. impreg. no no no no 2LOJDXJH *DVWLJKW yes yes yes yes no no no, no, only only oil-tight oil-tight no no yes yes,(&pd[ 7DQGHOWD 3' < 0,007 0,007 < 10 10 pc pc < 0,015 0,015 < 250 250 pc pc < 0,007 0,007 < 10 10 pc pc 2,/),//('%86+,1*6 '5<%86+,1*6

3URGXFWLRQRI5,3%XVKLQJV Conductor: - Al, Cu, - solid, tube Special creep paper Aluminium foils

3URGXFWLRQRI5,3%XVKLQJV 3 Under vacuum epoxy resin impregnation process 2 Drying process: - vacuum - heating 4 Curing process 1 Winding process

3URGXFWLRQRI5,3%XVKLQJV 5 Machining 6 Assembly 7 Routine Tests

5,3YV2,37HFKQRORJ\

5,37HFKQRORJ\LVWRGD\ VVWDWHRIWKHDUW SF6 - side of copper bar transformer side Simple Small Reliable Safe Environmentally friendly

Resin Impregnated Paper - R I P Bushings Main Advantages (1) HIGH TECHNICAL STANDARD - Low dielectric losses (tg delta < 0,35%) - PD free up to double service voltage - Excellent mechanical strength - High thermal strength (class E, 120 C) SUPERB IN DESIGN - No porcelain shell, except for outdoor use - Easy adaptable dimensions, customer-tailored bushings

Resin Impregnated Paper - R I P Bushings Main Advantages (2) STORAGE, INSTALLATION AND SERVICE: SIMPLE AND RELIABLE - Each position allowed (vertical to horizontal) - Dry, oil - free = simple in handling ENVIRONMENTALLY FRIENDLY - Pressure - free = explosion proof, fire resistant - No pollution by outflowing oil

RIP - Technology: summary of main advantages High technical level excellent mechanical strength low dielectric losses partial discharge free up to the double rated voltage high thermal strength (120 o C) Operation safe, service-friendly no damage risk on the bottom part no explosion risk with influence of the transformer gas tight heavy inflammable high operation safety also by damages of outer insulation no porcelain on transformer side Flexible in Design Adaptable on different transformer and plant constructions compact & robust no porcelain except for outdoor conditions silicon sheds possible any installation possible (vertical, horizontal) Environmental friendly oil free no explosion and fire risk through oil leakage no environmental risk through oil leakage maintenance friendly earthquake proof

NEW RIP Transformer Bushings GO WITH US AND GET THE MAYOR ADVANTAGE AGAINST YOUR COMPETITION!!

RIP - Technology for SF6 / Oil - Bushings In modern metal enclosed switchgear SF6 -gas is used as an extinguishing and insulating medium, ensuring highest security standard for operating staff and residents, especially in most confined and dense populated areas. As a result, today s space saving design requires excellent mechanical and electrical performance of all components involved. Micafil s contribution to this world-wide development is it s new product range of GARIP bushings. These have been designed for the direct single phase connection between power transformers and gas insulated switchgear (GIS) for rated voltages of 72.5 kv up to 550 kv. Since more than 40 years Micafil AG produces high voltage bushings made with Vacuum Resin Impregnated Paper Technology (RIP). We are proud of our leading position in this field, making available to our customers profound expertise in the latest state of the art technology, which is based upon more than 50000 RIP - bushings successful in operation. The insulation body of the GARIP condenser bushing series consists of a robust and solid core, made of wound crepe paper and inserted aluminium foils for field control, carefully vacuum dried and subsequently impregnated with special epoxy resin. The basic procedure for this new kind of manufacture was originally developed by Micafil AG in Switzerland already in 1958 and continuously improved in the course of four decades. Advanced standardisation, highly skilled craftsmanship and computer-aided engineering guarantee today s most reliable and advanced insulation system for every voltage level. Main advantages of Micafil s RIP- technology Short delivery times Low dielectric losses (tan δ ~ 0.35%) Partial discharge free up to double service voltage Fully dry, maintenance free Oil-free and environmental friendly Highest mechanical and thermal properties Robust design and vandalism resistant Option for any operating position Gas and oil tight Easy handling 2

Technical Data and Dimensions Dimension drawing 4xM12 25 deep D13 D14 80 Aluminium, silver plated Flange dimensions for: RTKG 72.5-350 / 2000 RTKG 72.5-350 / 2500 RTKG 123-550 / 2000 RTKG 123-550 / 2500 RTKG 145-650 / 2000 RTKG 170-750 / 2000 L L16 LF L2 s1 s2 20 L6 A B Grounded length D10 D9 D8 D1 D2 D5 Sealing area Ra =1.6 (N7) Test tap Sealing area Ra = 3.2 (N8) View A: SF6 side D12 D11 De-aeration of transformer opposite to test tap 22.5 22.5 45 n11 x Øw 45 c6 20 115 Ø18 D7 40 85 Shields removable Types 123kV - 245 kv View B: Oil side D4 D3 Copper, thickness 30 mm d4 d5 d6 20 Types 362kV - 525 kv M12 (2 x180 ) n3xøv M12 (2 x180 ) Flange dimensions for: RTKG 170-750 / 2500 RTKG 245-1050 / 2000 RTKG 245-1050 / 2500 RTKG 362-1300 / 2000 RTKG 420-1550 / 2000 RTKG 525-1800 / 2000 22.5 11.5 22.5 11.5 22.5 45 View A: SF6 side D12 D11 D12 D11 D12 D11 De-aeration of transformer opposite to test tap 15 30 n11 x Øw n3xøv 15 30 n11 x Øw n3 x Øv 11.5 22.5 n11 x Øw n3 x Øv View B: Oil side D4 D3 D4 D3 D4 D3 M12 (2 x180 ) M12 (2 x180 ) M12 (2 x180 ) M12 (2 x180 ) M12 (2 x180 ) M12 (2 x180 ) prospectus No. D 4352 E 4

General Informations Conductor loading Rated current dependent on the bushing lower length (see "Technical Data" page 5 & 6, column 12). Bushings selected with Ir not less than 120% of the rated current of the transformer are considered to be able to withstand the overload conditions according to IEC Publication 60354 (Loading guide). Recommendations for bushing installation Transformer The field strength in the oil on the surface of the shield insulation must be limited to values normal for insulated components. As a guideline minimum distances A to grounded transformer parts are given below: Type RTKG 123 145 170 245 362 420 525 AC test voltage (kv) 185 230 275 310 325 365 460 570 630 680 750 790 A (mm) 130 145 170 200 210 230 300 400 450 500 550 600 Type designation The type designation is included in an overall system. An example of nomenclature used to designate our GARIP bushings: GARIP RTKG 245-1050 / 2000 Testing of the bushing Nominal current (A) Lightning impulse voltage (kv) Rated voltage (kv) R=RIP Insulation T=Transformer application K=Short oil side part G= SF6 -gas application Bushing series Each bushing undergoes routine testing before leaving the factory, either according to IEC 60137 or IEEE C57.19.00. The standard tests include: Tan δ, capacitance and partial discharge measurement Power frequency test Lightning impulse test (if applicable) Leakage test Ordering particulars When ordering please state: Type and catalogue no. see the table below CT space L6, see "Technical Data" page 5 & 6, column 20 For 170 kv / 2000 A respective 245 kv / 2000 A only: choose the size of oil side shield depending on the transformer current; see "Technical Data" page 5 & 6, columns 26 &27 GIS A Observe the minimum enclosure diameter DGIS as well as the minimum operating SF6-gas pressure (see "Technical Data" page 5 & 6, columns 17 & 18). Adjacent conductor parts should be well adapted to the bushing terminal. General Because the bushing is completely dry it can be operated vertically or horizontally or in any position. Bushing type GARIP RTKG 72.5-350 / 2000 GARIP RTKG 72.5-350 / 2500 GARIP RTKG 123-550 / 2000 GARIP RTKG 123-550 / 2500 GARIP RTKG 145-650 / 2000 GARIP RTKG 170-750 / 2000 GARIP RTKG 170-750 / 2500 GARIP RTKG 245-1050 / 2000 GARIP RTKG 245-1050 / 2500 GARIP RTKG 362-1300 / 2000 GARIP RTKG 420-1550 / 2000 GARIP RTKG 525-1800 / 2000 Catalogue no. HLJM 154484 HLJM 154964 HLJM 154504 HLJM 154514 HLJM 154524 HLJM 154534 HLJM 154544 HLJM 154554 HLJM 154564 HLJM 154574 HLJM 154584 HLJM 154594 6