Slide table for 90 degrees adhesion test P90-200N

Similar documents
Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Automotive Engineered Attachment Systems

SURFACE MOUNT CERMET TRIMMERS (SINGLE TURN) Rotor. Wiper. Cover. Pin S T - 2 T A Ω ( )

SCREEN PRINTING INSTRUCTIONS

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Peel Back Force Tester GPD s Peel Back Force Tester with FORCEWare software is being used to set peel back standards for the entire industry

Technical specification bucket JET 53 P

DENSITY MEASURING SYSTEMS

3. Standards: Comply with ISO, BS, ASTM, JIS standard and so on.

Peel Adhesion of Pressure Sensitive Tape

MS9000SAN Rework Station

VICKERS HARDNESS TESTER. HBS HBW Kc

Equipment Information

Bringing good things ahead

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Non- Carbon Fiber Electrical Heating Textile Introduction:

Pulse Withstanding Thick Film Chip Resistor-SMDP Series. official distributor of

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Ultrasonic Reference Blocks

Integral Kit Instructions

Sliding and Folding Door Fittings Sliding Door Accessories

Computerized Electronic Univesal Testing Machine WDW-20Y

Product Specification

WELCOME TO VIASION.

Doc. No: Issue: 1 Date: Aug BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02

PRODUCT DATASHEET. Confidex Ironside Micro CONTENTS

1.1.2 Polypropylene The polypropylene must be a white opaque film, 1 2 mil thick. Biaxial orientation is preferred.

Operating Instructions Drill rig DRU160

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

MODEL TEG-F20. Specification Sheet. TEG-F20 Specification Sheet Ver Copyright(C) 2011 Tsukasa Sokken Co., Ltd.

Installation Instructions For Slider Casement Air Conditioners

TENSIONMETER ** code 183_LNRSTW **

DuPont Kapton. polyimide film. General Specifications

FLEXIBLE THERMAL INSULATION MADE OF SILICONE

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Roofing hand tools overview 47

T 549. WORKING GROUP CHAIRMAN N/A; reaffirmed SUBJECT RELATED

Roller Chain Coupling

HARTING Ethernet Cabling 4-poles Overview

1x90 TONS TENSIONERS TECHNICAL PROPOSAL. 1 X 90 Tons 30 m/min Tensioners TECHNICAL PROPOSAL JOB 08/ /02/2008 Basic proposal PP GM SB

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

OPERATING INSTRUCTIONS

TechCut 4 Precision Low Speed Saw

Free Stall Cleaner System with Cable. A new generation of equipment and systems. GEA Farm Equipment Houle

Video conference solutions

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Belt and Roller Conveyor for boxes and containers

Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.

2/2 and 3/2 Way Size 6 Seat Valves

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

How To Fit A Portman Door Leaf

DCS Input/Output Relay Card Series

Slides and Drawers. The right collection

Sommer. Sommer 6. by barwick

SIGRAFLEX . Properties. Applications

peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11

IPR Äspö Hard Rock Laboratory. International Progress Report. Temperature Buffer Test. Report for retaining plug and anchoring

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Accesorios para el Traceado Eléctrico Industrial Industrial Heat Tracing Accesories

HIGH VOLTAGE TEMPERATURE COMPENSATED ZENER REFERENCE DIODES

Video conference solutions

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Electric Flow Boiler

Cree 5mm Round LED C503D-WAN

AISI O1 Cold work tool steel

Rufa 2.4 GHz SMD Antenna Part No. 3030A5839 / 3030A5887 Product Specification

3 Thermal Transfer Acrylate Label Material 3921

TASTECH SERVICES LTD. Manufacturer and Supplier of Equipment and Daily Living Aides to Hospitals, Resthomes, OT s and the General Public

16/32 Channel 1U Rack Mount CCTV Power Supply

Aluminium Standard. Technical Data. Included in delivery

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

Perfection in packaging

Film Scanner The term Film Scanner can refer to a dedicated slide and negative film scanner or to a capture type scanner.

Vandal-proof keypad series

heat treatment equipment & accessories

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

WW12X, WW08X, WW06X, WW04X ±1%, ±5% Thick Film Low ohm chip resistors

Roofing. VARIMAT V2 36 UNIROOF E 38 TRIAC DRIVE PID / Guiding aid 39 X BITUMAT B2 41 COMET SUB-ROOF 42 Overview welding machines 43 EXAMO 45

Intexma Graphics (Pty) Ltd

3216 Ceramic Chip Antenna for Bluetooth/WLAN Application

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

Radial piston pumps type R and RG

6 Design of Gates. 6.1 The Sprue Gate

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

RESERVDELSLISTA NORMFINISH DP14

3. Loosen 3 x grub screws in the Dec end cap and unscrew the cap and counterweight shaft. NEQ6 Belt Modification Kit.

Festoon 715 P PUR cable for flexible application in festoon systems

Fusca 2.4 GHz SMD Antenna

WATERPROOFING OF WET ROOMS

Safety at a high level!

S4 - Top Hung Window. Outside view. Inside view. Interior frame. Exterior frame. Glazing Panel

Lift- and transport truck HTW 50/100 Standard model

Cree 5mm Round LED C503B-WAN

Certificate of shape stability

Machine nozzle with needle shut-off type HP pneumatically or hydraulically controlled

for vehicle measuring

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

High Frequency Ceramic Solutions

Transcription:

Slide table for 90 degrees adhesion test P90-200N Best for peeling test at 90 degrees. Two types of model are available. 1. Standard Type (JIS): P90-200N 2. Economy Type: P90-200N-EZ 安 価 に 測 定 できるローコストタイプ P90-200N P90-200N-EZ P90-200N-EZ [Meets the standard JIS] Enable to peel the sample, keeping 90 degrees. Good for more accurate measurement. [Best for elastic samples] The table does not necessarily keep sample 90 degrees, but it is economy. May not appropriate for the measurement of under 0.4N or with sudden force change. Feature 1 Feature 2 Feature 3 Keeps 90 degrees Meets JIS For various samples The string keeps the peeled sample 90 degrees, connecting the slide table and a force gauge. [P90-200N Only] It partly meets Japanese Industrial Standards, JIS C5016:1994 and Z0237:2000. [P90-200N Only] Not necessarily need to stick the sample on the plate of the slide table. Sample sealed on other plate can be set on the slide table. *The thickness of plate should be within 2mm 1 / 5

Composition example Motorized test stand MX2 series Digital force gauge ZT series Slide table for 90 degrees adhesion test P90-200N *This is Long stroke model Film grips FC-21U Software for graph drawing Force Recorder Standard *Some samples of certain material / shape may not be used with this. PC is not included. combination Case 1 [Standard measurement] Slide table for Software for Cable for Motorized peeling at 90 Digital force gauge Film grips graph drawing force control test stand degrees [P90-200N] [ZT Series] [Force Recorder [CB-518] [MX2-500N] [FC Series] Standard] *1 *2 *3, *4 To analyze the whole measurement by drawing graphs. Case 2 [Economy measurement] [P90-200N-EZ] [DS2 Series] *1 To have peak force only. [N/A] [N/A] *1. It is appropriate to use Digital Force Gauge for adhesion test. 90 degrees cannot be kept with mechanical force gauge because of its structure. *2. We suggest use cables to avoid over load. (Available only with ZT series) *3. It is appropriate to use Motorized Test Stand for adhesion test. We especially recommend use MX2 series with which test speed can be set. *4. A test stand with longer stroke is available if the test sample is too long to use normal stroke. 2 / 5

Peeling of plastic tape (with P90-200N) Measurement example Peeling of PCB (with P90-200N) Peeling of elastic tape (with P90-200N-EZ) Measurement meeting JIS Z0237 partly Measurement meeting JIS C5016 partly Measurement of elastic sample *Digital force gauges, test stand, film grips are not included to P90-200N/P90-200N-EZ. Specifications Model P90-200N P90-200N-EZ Length (sample) 155mm (max.) Width (sample) 80mm (max.) Capacity 0 to 200N 0.4 to 200N Dimensions See page 4 Weight Approx 2kg Fixable test stand MX-500N, MX2-500N, MX-1000N, MX2-1000N * Please contact us in case using with other models of test stand. Weight roller APR-97 (Meets JIS Z0237:2000) Option Spare stainless panel SSP-1608 It helps to stick samples on the panel with stable force, which leads stable measurement result. (Meets JIS Z0237:2000) Needles to take off and wash the panel every measurement, if you have spare panel. It helps save time and work. 3 / 5

Special measurement With a heater Many peeling angles (0-180 degree) Heater is integrated in the table to put sample on. You can adjust temperatures by the external controller. Angle changeable from 0 to 180 degree freely. Please feel free to contact us (info@forcegauge.net / +81-(0)532-33-3288) for more detail of products above, design change, and so on. Related products 180 degree peeling fixture P180-200N 180 degree peeling test of tape with P180-200N Fixture for film sticking test TKS-250N/TKS-20N Sticking strength test of film with TKS-250N 180 degree peeling tester IPT200-5N/20N/50N Exclusive for peeling test Easy to handle and set up samples *Force gauges, test stands, optional attachments are sold separately. 4 / 5

[Dimensions] [P90-200N] [P90-200N-EZ] [Caution] -The contents may be changed without previous notice. -All of products are designed for measurement purpose only. -Force gauges, test stands, optional attachments are not included but necessary to carry out tests. -Some sample cannot be measured depending on their materials or shapes. -Do not copy and use this content without authority. Please feel free to contact us for measurement solutions, distributor s information in your country, and so on. TEL: +81-(0)532-33-3288 Email: info@forcegauge.net 5 / 5