ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 123 2011



Similar documents
ENGINEERING COMMITTEE

F Male DBS Connector Dimensional and Performance Specification

AMERICAN NATIONAL STANDARD

SMA Interface Mating Dimensions (Per MIL-STD-348)

ENGINEERING COMMITTEE Energy Management Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics

ULTIMATE SNAP-N-SEAL

ENGINEERING COMMITTEE Construction and Maintenance Subcommittee

Times Microwave Systems Hermetically Sealed Assemblies

SMA Connectors. RF Coax Connectors. Product Facts

W1 Connector W1 Adapter W1 Termination

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

SMA Series Subminiature RF Connectors

Standards Affecting a Premise T-1 Installation

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

COAXICON Contacts. RF Coax Connectors. Product Facts

Agilent X/P/K281C Adapters

ULTRARANGE COMPRESSION CONNECTORS

Connecting the Channel A

BNC, N, TNC Connectors

Cables. Accessories. For Force, Torque and Strain Sensors

MAURY. VNA Calibration Kits, Microwave Components & Adapters. Calibrate With Confidence IN THIS CATALOG:

TFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

Test Cable Assemblies

I-PEX MHF4 Micro Coaxial Connector

Making a Case for a New Connector

Cables. Indoor, Outdoor, HDMI, CAT, connectors. Cables, connectors and tools

37 JIC Flare (Nuts) 304C (070112) 306 (070118) 318 (070110) Pg Bulkhead Locknut (Use with #2700) Pg. 23 Tube Nut (Use with #319)

N type Coaxial Connectors

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

EMC Test Chamber Solutions RF Cable Assemblies and Connectors

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

Operating Instructions

Current Probes. User Manual

Uniprise Solutions COAX 101. White Paper.

spinner Measurement & Calibration equipment for network analyzers

Weatherproofing Kit for Connectors and Antennas

Application Guide to RF Coaxial Connectors and Cables

S-Level and Hi-Rel Connectors Power Rating for Coaxial Connectors Mounting Guidelines For Flange Mount Connectors...

SMA Waterproof. Cable Assembly. Filtered Audio Connector. Dataport Receptacle. Dataport Plug

MICRO-COAX Space Grade Cable Assembly Integration Manual

AMPSEAL* Automotive Plug Connector and Header Assembly

Commercial Coaxial Cable

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

Test and measurement cable assemblies

EH-20 20m antenna. By VE3RGW

AMERICAN NATIONAL STANDARD

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

SUBMITTAL 10 FEET. Cast Iron Soil Pipe Products Hubless Pipe & Fittings HUBLESS PIPE 10 FEET*

Fakra. Coaxial connectors. DC 6 GHz

Communication, Signal & Data Cables

Semi-rigid Coaxial Cables

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

V281C/D and W281C/D 1.0 mm Coaxial to Waveguide Adapters. Operating and Service Manual

Screw Thread Design. Rev

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Sunridge MCB Series Miniature Coaxial Interconnect, 2.5mm or 2.0mm Mated Height

PDI-P10LCD Pre-Tensioned Swivel Cartridge

C ole s quality Open Frame Instrument Rotary Switch provides low

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

CAVEL VS80205 MADE IN ITALY 1000 V

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Trunk Cables.

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

PCb Cable mount twinax. ConneCtorS

Setting a Higher Standard

Ultra Small Surface Mount Coaxial Connectors - 1.9mm or 2.4mm Mated Height

Working Pressure - Hose Ends

400 Series - Mini USB Buccaneer

RF & Microwave cable assemblies C291

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

INSTALLATION PROCEDURES FOR PRINTED CIRCUIT BOARD TERMINATORS D-607-XX

ENGINEERING COMMITTEE Digital Video Subcommittee SCTE METHODS FOR CARRIAGE OF CEA-608 CLOSED CAPTIONS AND NON-REAL TIME SAMPLED VIDEO

Gulf Cable & Electrical Ind. Co.

General Information. Lower Frequency Models Custom Designs Special Flanges Narrow Band Specials VSWR. Frequency ( GHz) COMMON SPECIFICATIONS


Cinch Connectivity Solutions. High Frequency End Launch Connectors

db MISER ULTRA LOW LOSS CABLE ASSEMBLIES Are you a design or test engineer fighting a challenging loss budget?

Universal MATE-N-LOK Connectors

1394 locking cables. Your locking cables for AVT IEEE 1394 cameras

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

The SMA RF Connector and Associated Tools Whitham D. Reeve

Design Techniques for High Power RF Coaxial Cable Assemblies

SIMRAD SD10 Sailboat Drive

Broadband Telecommunications Drop Amplifier

V47 Series Temperature Actuated Modulating Water Valves

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30

LOXONE 12 Channel Amplifier

Measurement & Modeling Device Characterization Solutions

Index mm Connector Series mm Connectors (50 GHz)... Page. Interface Standards Specifications Connector Numbers...

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

Transcription:

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 123 2011 Specification for F Connector, Male, Feed-Through

NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards are intended to serve the public interest by providing specifications, test methods and procedures that promote uniformity of product, interchangeability and ultimately the long term reliability of broadband communications facilities. These documents shall not in any way preclude any member or nonmember of SCTE from manufacturing or selling products not conforming to such documents, nor shall the existence of such standards preclude their voluntary use by those other than SCTE members, whether used domestically or internationally. SCTE assumes no obligations or liability whatsoever to any party who may adopt the Standards. Such adopting party assumes all risks associated with adoption of these Standards, and accepts full responsibility for any damage and/or claims arising from the adoption of such Standards. Attention is called to the possibility that implementation of this standard may require the use of subject matter covered by patent rights. By publication of this standard, no position is taken with respect to the existence or validity of any patent rights in connection therewith. SCTE shall not be responsible for identifying patents for which a license may be required or for conducting inquiries into the legal validity or scope of those patents that are brought to its attention. Patent holders who believe that they hold patents which are essential to the implementation of this standard have been requested to provide information about those patents and any related licensing terms and conditions. Any such declarations made before or after publication of this document are available on the SCTE web site at http://www.scte.org. All Rights Reserved Society of Cable Telecommunications Engineers, Inc 2011 140 Philips Road Exton, PA 19341

TABLE OF CONTENTS 1.0 SCOPE...1 2.0 DEFINITIONS AND ACRONYMS...1 3.0 NORMATIVE REFERENCES...2 4.0 INFORMATIVE REFERENCES...3 5.0 ELECTRICAL REQUIREMENTS...3 6.0 MECHANICAL REQUIREMENTS...3 LIST OF FIGURES FIGURE 1 RECOMMENDED MALE F FEED-THROUGH CONNECTOR DRAWING 4 LIST OF TABLES TABLE 1 RECOMMENDED MALE F FEED-THROUGH CONNECTOR DIMENSIONS 4

1.0 SCOPE The purpose of this document is to specify requirements for male F feed-through connectors that are used in the 75 ohm RF broadband communications industry. This specification applies to SCTE drop cable specifications ANSI/SCTE 74 2003, ANSI/SCTE 71 2008, and ANSI/SCTE 100 2010. All requirements of this document are measured after installation per manufactures instructions of the cable into the connector. 2.0 DEFINITIONS AND ACRONYMS 2.1 Dielectric: The material that is used to insulate the center conductor from contacting the outer housing. 2.2 Thread Relief: A reduced diameter section of the threaded surface to allow the tool to run out. This feature is optional. 2.3 Center Conductor: The inner conductor of a coaxial cable that is fed through the male F feed-through connector. 2.4 Reference Plane: The reference plane on the male F feed-through connector is the mating surface that seats against the female F port. It is also the plane from where all horizontal dimensions are taken. 2.5 Parting Line (relevant to casting process only): A raised mark left on the surface of a part as a result of the gap between two halves of a die.

3.0 NORMATIVE REFERENCES The following documents contain provisions, which, through reference in this text, constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreement based on this standard are encouraged to investigate the possibility of applying the most recent editions of the documents listed below. 3.1 SCTE References ANSI/SCTE 60 2010, Test Method for Interface Moisture Migration ANSI/SCTE 74 2003, Specification for Braided 75 Ohm Flexible RF Coaxial Drop Cable ANSI/SCTE 71 2008, Specification for Braided, 75 Ohm, Coaxial Multi-Purpose Cable ANSI/SCTE 98 2009, Test Method for Withstand Tightening Torque - 'F' Male ANSI/SCTE 99 2009, American National Standard Test Method for Axial Pull Connector/Cable ANSI/SCTE 100 2010, Specification for 75 Ohm Smooth Aluminum Access Cables ANSI/SCTE 103 2004, Test Method for DC Contact Resistance ANSI/SCTE 01 2006, Specification for F Port, Female, Outdoor ANSI/SCTE 02 2006, Specification for F Port, Female, Indoor ANSI/SCTE 143 2007, Test Method for Salt Spray 3.2 Standards from other Organizations Not applicable.

4.0 INFORMATIVE REFERENCES The following documents may provide valuable information to the reader but are not required when complying with this standard. 4.1 SCTE References Not applicable. 4.2 Standards from other Organizations Not applicable. 4.3 Published Materials Not applicable. 5.0 ELECTRICAL REQUIREMENTS 5.1 Impedance: The male F feed-through connector shall perform with a nominal impedance of 75 ohms. 5.2 Return Loss: Please see equipment specifications that the male F feed-through connector is a part of for specific return loss requirements. 5.3 The outer conductor junction of the female F port to male F feed-through connector shall have a DC contact resistance less than 10 milliohms when tightened to 35 in.-lbs. and tested to ANSI/SCTE 103 2004. 5.4 Shielding Effectiveness: The shielding effectiveness for male F feed-through connectors, when attached to cables manufactured to SCTE approved standards, shall meet shielding performance levels of an unspliced section of the same cable when both are tested with the same method. 6.0 MECHANICAL REQUIREMENTS 6.1 Physical dimensions The recommended physical dimensions for the male F feed-through connector shall be as specified in Figure 1, Table 1, and per the notes below.

Figure 1 Recommended Male F Feed-Through Connector DESCRIPTION DIM Mm inches NOTES MIN MAX MIN MAX REF. CABLE CENTER CONDUCTOR DIA. A 0.64 1.07 0.025 0.042 SEALING SLEEVE DIAMETER B 10.41 11.05 0.410 0.435 NUT THREADED LENGTH C 3.97-0.156-3 MANDREL FACE DEPTH TO NUT LEADING EDGE CENTER CONDUCTOR TO MANDREL FACE LENGTH D 4.29 6.10 0.169 0.240 E 6.35 9.53 0.250 0.375 MANDREL FACE OUTER DIAMETER F 7.11-0.280 - NUT TO SEALING SLEEVE INTERFACE LENGTH G 1.78 4.45 0.070 0.175 MAXIMUM ENVELOPE DIMENSION H - 12.95-0.510 CHAMFER BREAK J 0.25 0.76 0.010 0.030 4 MANDREL FACE INNER DIAMETER K - 5.84-0.230 NUT HEX LENGTH L 4.75-0.187 - Table 1 Recommended Male F Feed-Through Connector Dimensions

NOTES 1 DIELECTRIC MUST NOT PROTRUDE BEYOND REF. PLANE 2 THE MATING OF THE FEMALE F TO THE REFERENCE PLANE SHOULD NOT BE IMPEDED. 3 MINIMUM ONE THREAD LEAD-IN. 4 RADIUS OPTIONAL. 5 DRAWING NOT TO SCALE. 6 INTERPRET DRAWING IN ACCORDANCE WITH ASME Y14.5M-1994. 6.2 Mechanical Strength 6.2.1 Withstand Tightening Torque: The male F feed-through connector shall withstand a minimum tightening torque of 60 in-lbs. without damage when measured per ANSI/SCTE 98 2009, Test Method For Withstand Tightening Torque F Male. 6.2.2 Axial Pull Force: The male F feed-through connector, when attached to cables manufactured to SCTE approved standards, shall withstand a minimum axial pull force of 40 lbs. for outdoor and 30 lbs. for indoor applications when tested per ANSI/SCTE 99 2009, Test Method For Axial Pull Connector/Drop Cable. 6.3 Outdoor Environmental Requirements 6.3.1 Male "F" feed-through connectors shall meet the environmental requirements of the equipment to which they are attached and the requirements specified in this document. 6.3.2 Interface Moisture Migration: Male F feed-through connectors, when attached to cables manufactured to SCTE approved standards, shall have no penetrant present or evident, when inspected visually, after undergoing testing per ANSI/SCTE 60 2010, Interface Moisture Migration Test. 6.3.3 Salt Spray: Male "F" feed-through connectors shall be exposed to 1000 hours min. continuous salt spray per ANSI/SCTE 143 2007, Test Method For Salt Spray.