for light and heavy duty diesel engines

Similar documents
Bi-fuel systems for Diesel Engines in Oil & Gas drilling environments

Understanding Tier 4 Interim and Tier 4 Final EPA regulations for generator set applications

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Element D Services Plumbing

E - THEORY/OPERATION

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

C18 ACERT Fire Pump Tier bkw/ rpm

3516 Industrial Engine

Unit 8. Conversion Systems

The Use of Exhaust Gas Recirculation (EGR) Systems in Stationary Natural Gas Engines. The Engine Manufacturers Association August 2004

MIXED HYDROGEN/NATURAL GAS (HCNG) TECHNOLOGY- VISIT AT COLLIER TECHNOLOIES

Medical Air Systems: Scroll

Diesel Engine Driven Generators Page 1 of 6

EPA Requirements for Diesel Standby Engines In Data Centers. Bob Stelzer / CTO / Safety Power Inc. For 7x24 Fall 2014 Conference. 1.

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Micro Motion 3098 Gas Specific Gravity Meter

The 2.0l FSI engine with 4-valve technology

Exhaust emissions of a single cylinder diesel. engine with addition of ethanol

Chapters 7. Performance Comparison of CI and SI Engines. Performance Comparison of CI and SI Engines con t. SI vs CI Performance Comparison

Signature and ISX CM870 Fuel System

Better. Where It Counts. Cummins 2013 ISB6.7 For Truck Applications.

Turbo Tech 101 ( Basic )

Environmentally Friendly Drilling Systems

ISX15 and ISX Well Servicing Applications. ISX15 (EPA 2010) hp ( kw) ISX (EPA 2007) hp ( kw)

CAT POWER for On-Highway Performance and Fuel Economy

Perfectly Adapted. ISL Euro 6 Gas Engine PS

Description of Thermal Oxidizers

Electronic Diesel Control EDC 16

Pollution by 2-Stroke Engines

A.Pannirselvam*, M.Ramajayam, V.Gurumani, S.Arulselvan and G.Karthikeyan *(Department of Mechanical Engineering, Annamalai University)

Engineering, Bharathiyar College of Engineering and Technology, Karaikal, Pondicherry , India

ECO-STAR II. ECO-nomical ECO-logical the ECO-STAR II. Packaged Low NOx Multi-Fuel Burner. Features. Benefits. Combustion Excellence Since 1888 ESII-1

Spark-ignited generator set

Marine after-treatment from STT Emtec AB

Comparative Assessment of Blended and Fumigated Ethanol in an Agriculture Diesel Engine

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Kompressoren. Adsorption Dryer AD

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Reliability Accuracy Performance

Dual Fuel Medium Speed Product. Presenter Name Date

CAT CG132. Series Gas Generator Sets

Technical Specification. Generating Set with Waukesha engine burning natural gas

Why and How we Use Capacity Control

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Diagnostic Fault Codes For Cummins Engines

Diagram of components 2. Reducer..3

Accumulators and Receivers

Kolbenschmidt Pierburg Group

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine.

Breakthrough Solenoid Valve Technology for Upstream Oil and Gas Heating Equipment

THM Gas Turbines Heavy duty gas turbines for industrial applications

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

Signature and ISX CM870 Electronics

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

SELECTION, APPLICATION AND MAINTENANCE

The On-Board Refueling Vapor Recovery (ORVR) Evaporative Emission (EVAP) system.

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Typical ECM/PCM Inputs

Copyright 1984 by ASME. NOx ABATEMENT VIA WATER INJECTION IN AIRCRAFT-DERIVATIVE TURBINE ENGINES. D. W. Bahr. and T. F. Lyon

CAT ENGINES WITH ACERT TECHNOLOGY AN INTRODUCTION THE POWER TO LEAD

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Morrison Bros. Co. General Product Specifications

Continuous flow direct water heating for potable hot water

HEAVY-DUTY, REDEFINED. REDEFINED.

Tips for a Successful Diesel Retrofit Project

Fundamentals of Mass Flow Control

Cummins Westport, Inc. Engine Overview. March 2015

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Principles of Engine Operation

Propane-Fueled Microturbine: Case Study

Table of Contents. Introduction Benefits of Autogas Fuel Safety U.S. vs. Worldwide Autogas Vehicles... 10

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

Laws and price drive interest in LNG as marine fuel

Nitrogen Blanketing for Methanol Storage and Transportation

INDUSTRIAL ENGINE RATINGS GUIDE

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Perfectly Adapted. ISB Euro 6 Diesel Engines PS. Cummins Ltd. Address Line One Address Line Two Address Line Three

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

Hydrogen as a fuel for internal combustion engines

Citius-sarjan merimoottorit

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

EVERY ROUTE. ISB FOR SCHOOL BUS APPLICATIONS

Backup Fuel Oil System Decommissioning & Restoration Plan

SELECTION, APPLICATION & MAINTENANCE

FAC 7.1: Generators. EPA Impacts on Emergency Gensets for 2015 Installations

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

Full Technical Catalog For Closed-loop Sampling System

TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES

EPA emission regulations: What they mean for diesel powered generating systems

Performance Analysis of a. for a Diesel Engine

Integrated Custom Systems

PREPARATION FOR TESTING

SELECT Hg Ultra-purification of mercury from natural gas

EveryTM. Coverage. North American Truck Coverages For 2013 ISL9 And ISB6.7 Engines.

BRASH Air-Steam Hybrid Technology for Combined Heat and Power (CHP)

Clear Advantage. EveryTMEngine. QSB6.7 And QSL9 ( hp) Tier 4 Interim/Stage IIIB

Heating Water by Direct Steam Injection

Transcription:

for light and heavy duty diesel engines

Operate Your Diesel Engine on Natural Gas No engine modifications required No power or efficiency losses Low cost and easy to install Reduces operating costs Extends run-time of standby engines Lowers emissions No high-pressure gas supply Allows use of interruptible gas State-of-the-art controls and monitoring The GTI Bi-Fuel System from Altronic, LLC is an innovative technology that enables operators of light and heavy duty diesel engines to substantially reduce operational costs and lower emissions (with use of DOC) by substituting diesel fuel with lower cost, clean erburning natural gas. Simplicity of Design and Operation GTI Bi-Fuel Systems follow a design philosophy of simplicity. The system does not interface with the diesel control governor, but instead remains independent. This allows the diesel governor to react to changes in genset load without interference of the gas system. In this manner, the diesel LEADS, and the gas LAGS. This philosophy ensures safe engine operation with no compromise in the operation of either fuel system. The GTI Bi-Fuel System is comprised of patented technologies that allow engines to safely operate on gas percentages $4.50 up to a maximum of 70%* of the total fuel requirement. Engines $4.00 converted to GTI Bi-Fuel exhibit $3.50 diesel-like performance in such critical areas as efficiency, stability $3.00 and load acceptance. A key feature of the system is its ability to switch fuel modes without interruption in engine power output. The engine can be switched between diesel and gas automatically while maintaining speed and load. This feature gives the user the flexibility to choose between gas and diesel modes as dictated by fuel pricing, fuel availability or other operational $2.50 $2.00 $1.50 $1.00 $0.50 $0.00 considerations. An equally important feature is the ability to maintain engine power levels while operating in gas mode between the continuous and prime ratings of the engine. For operations above the programmed power limit, the engine is automatically switched to 100% diesel mode, thus avoiding the necessity to derate the engine. The GTI Bi-Fuel System uses a state-of-theart electronic control and monitoring system which monitors critical engine and bi-fuel system parameters and activates or deactivates gas mode accord ing to programmed limits. When a monitored parameter exceeds the allowable limit, the controller switches the engine to 100% diesel mode and electronically logs the fault for diagnostic purposes. The control panel is CSA-approved for Class I, Division 2 environments. Cost Savings Displacing a percentage of diesel fuel with methane-based gas provides an immediate economic benefit based on the cost difference between the fuels and the amount of run time of the genset. In high usage gensets, the GTI System can pay for itself in a short period of time. Simple Excel-based spread sheets are available to assist in modeling the economic benefits of converting to GTI Bi-Fuel. US No. 2 Diesel (without Road Tax) US Well Head Gas Price in Diesel Equivalent Gallons Increased Run Time Reducing the amount of diesel fuel used extends the run time in proportion to the substitution rate, providing extra hours of operation in critical applications. Simplified Logistics The frequency of refueling is reduced, thereby lessening the costs and risks associated with hauling diesel fuel. Reduced Liquid Fuel Storage As environmental concerns about liquid fuel storage increases pressure on operators, using the GTI Bi-Fuel System offers some relief by reducing the volume of above-ground diesel fuel storage. Emissions Altronic has commissioned independent third party emissions testing of the GTI Bi-Fuel System on industry representative engines by EPA and CARB-certified laboratories to stringent industry testing standards and procedures. Results demonstrate conclusively that, when properly installed and commissioned on engines maintained to OEM standards, operation of the GTl Bi-Fuel System can result in a reduction of oxides of nitrogen (NOx), particulates (PM), non-methane hydrocarbons (NMHC), and carbon monoxide (CO).** Jan-2012 Flare Gas Reduction Pressure to reduce the flaring of waste gases into the atmosphere continues to increase worldwide. The GTI-Bi-Fuel System allows these unwanted gases to be used as fuel for the generation of electrical power. Flexible Fuel Rates Gas suppliers offer discounted rates to customers who can tolerate supply interruptions in times of high demand/inadequate supply. GTI Bi-Fuel provides for this option since the genset can operate on 100% diesel at any time. Bi-Fuel is a registered trademark of ALTRONIC, LLC U.S. PATENTS 6,250,260 and 6,543,395 *Substitution rates can vary from 25% to 70%, subject to gas quality and other application conditions. **Requires the use of a properly sized diesel oxidation catalyst (DOC). Altronic recommends the use of such DOC on all bi-fuel applications. Contact your local GTI Distributor for details.

Reduced Capital Costs Due to the higher power density of diesel engines relative to pure spark-ignited gas engines, the cost per kw produced of a diesel engine can be significantly less compared to the same output gas engine. GTI Bi-Fuel allows the user to enjoy many of the benefits of gas engine operation coupled with the lower capital cost of the initial purchase. Operation and Performance Gas is introduced downstream of the engine air cleaner and upstream of the turbocharger. The gas is supplied at approximately atmospheric pressure using a proprietary air-fuel mixer that allows for a high level of gas mixing with the least possible air restriction. The air-gas mixture is compressed in the turbocharger and distributed to each cylinder by the engine air-intake manifold. The lean airgas mixture is compressed during the compression stroke of the piston and ignited by reduced diesel spray. Since the air-gas mixture is maintained in a lean condition, pre-ignition does not occur. Flow of gas to the engine is load dependent and varies with combustion airflow changes. The Bi-Fuel System varies gas flow according to changes in the turbo intake signal. This allows it to respond to engine fuel requirements while maintaining the integrity of the OEM governing system. The standard GTI Bi-Fuel System incorporates a manually-adjustable power valve to control the gas substitution rate. Diesel injection is controlled by the OEM governing system during both gas and diesel modes. The Bi-Fuel controller monitors various engine and system parameters such as manifold air pressure and temperature, exhaust gas temperature, intake vacuum, gas pressure and engine vibration. This information allows the controller to determine when to activate or deactivate bi-fuel operation depending on engine performance, load level, ambient temperature, knock limits or gas supply pressure levels. The controller can communicate with remote engine monitoring systems via RS-232/RS-485 connection (ASCII or MODBUS protocol). Engine performance is on par with normal diesel levels. Heat rejection levels to the exhaust and water jacket systems are kept within normal operating parameters. Engine response to load variation is typically equal to, or better than, 100% diesel performance due to the unique design of the Bi-Fuel System and the associated combustion characteristics of the air-gas mixture. Similarly, engine load acceptance (for large block loads) meets or exceeds straight diesel performance. Factory Trained and Certified Technicians Altronic requires each GTI Master Distributor to have a factory certified technician on-staff. Altronic provides a rigorous training and on-engine audit program to its distributors to insure quality of installation and commissioning of the GTI Bi-Fuel System to provide proper system performance and engine safety to its customers.

GTI+ BI-FUEL SYSTEM The GTI+ Bi-Fuel System builds on the experience of over 3300 installed GTI Bi- Fuel Systems worldwide. The GTI+ platform offers improved performance through the use of an innovative new mixer design and fully electronic, closed-loop fuel control valve-based gas train. The design increases system responsiveness, reduces the degree of and eliminates the effect of any parasitic pressure drop between the gas train outlet and turbocharger inlet. The GTI+ Bi-Fuel System maintains the basic design philosophy of the original GTI product line: Simplicity in design and operation, while maintaining a true zeropressure draw through configuration that maximizes engine safety. The GTI+ System is ideal for applications such as drilling rigs, where the optimal substitution rate needs to be mapped across the genset load range. The Altronic AGV5-2L valve combines the function of a closed-loop, electronic zero governor with that of a substitution control valve, providing a fast responding and reliable fuel control system. Electronic Gas Train The GTI+ System utilizes a fully electronic, advanced gas train design. At the heart of this system is a specialized version of the Altronic AGV5 fuel valve. The AGV5 is a microprocessor-based smart valve equipped with a fast-acting voice coil for rapid and accurate response. The AGV5 serves as both the zero governor pressure controller and fuel valve to control the bi-fuel substitution rate across the engine load range. The valve responds in closed-loop control to an electronic pressure signal within the mixer housing, ensuring that the fuel demand at the mixer is satisfied at any given time and eliminating pressure droop associated with pneumatic pressure control systems. This closed-loop control minimizes the effects of pressure drops

GTI+ Bi-Fuel System Operation and Performance J I J Engine RPM Regulated Gas Pressure Sensor Gas 3-15psig Plenum between the outlet of the gas train and the mixer inlet. This allows the desired substitution rates to be met while maintaining the fundamental safety characteristics of a zero pressure draw-through design. The AGV5 is a proven design that has been used as the fuel control device in hundreds of gas engine applications. Its soft-seat poppet is highly tolerant of gas stream contamination and offers fail safe reliable service. Since the AGV5 is rated to a higher pressure, the gas train can accept gas supply pressure of up to 50psig, eliminating the need to reduce higher gas supply pressures to lower gas train inlet pressures with an added primary regulator. The new enhanced gas train also uses a highly-reliable, automatic, fast-acting, Diesel Substitution (%)* 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 industrial shutoff valve to provide dual shutoff capability. DE-3020 Controller Platform The GTI+ Bi-Fuel System uses an upgraded DE control platform which provides for GTI+ Example Engine Load (%) configurable I/O for increased flexibility in application across the broad expanse of diesel engines in use today. GTI+ *Diesel substitution rates can vary based on factors such as gas fuel quality, engine design and condition, engine load profile, ambient temperature, application etc. Altronic makes no guarantee of achievable substitution.

Major System Components and Sub-systems Air-Fuel Mixer The GTI Bi-Fuel System uses a proprietary air-gas mixing device that has been designed for optimum blending of natural gas and engine intake air. Mixing of air and gas is achieved using a sophisticated, fixed-venturi design that avoids the use of an efficiency-robbing throttle plate. The low restriction air-gas mixer ensures that adequate air-flow is maintained to the engine and that operating efficiencies are not compromised by installation of the device. The computer-aided-design mixer is built to aerospace tolerances using CNC machining processes and is assembled using state-of-the-art welding techniques. The finished mixer has no moving parts once installed in the engine air-intake system, and requires no routine maintenance. Plenum The plenum works in conjunction with the DN65, DN80, or GTI+ gas train and air-gas mixer to control the amount of gas supplied to the engine for a given engine load with very low restriction and pressure drop. The plenum consists of three main parts: inlet plenum plate, plenum barrel (chamber, hardware, and diffuser plate), and outlet plenum plate (1, 2, 4, and 6 outlet JIC hose connections). The plenum is constructed of CNC-machined aerospace quality aluminum, and mil-spec anodized for surface hardness and corrosion protection. Gas Trains Conditioning and regulating the natural gas prior to admission into the engine is a critical part of the GTI Bi-Fuel System. The system gas train includes a 50-micron fuel filter, an electricallyoperated solenoid valve, actuated in the event of an emergency or for system shutdown, and a zero-pressure, demandtype gas pressure regulator or, for the GTI+ System, a smart, fast-acting fuel control valve. This latter component reduces the inlet gas pressure to roughly atmospheric pressure. With a negative outlet pressure, the design allows the system to use a demand control scheme whereby engine intake airflow determines the gas flow of the engine. As engine load changes, corresponding changes in intake air volume automatically draw additional fuel into the mixer. Engine Control System The Engine Control System is based on proven Altronic controllers and provides state-of-the-art engine control and safety shutdown monitoring. The controller is designed specifically for the GTI Bi-Fuel System and is straight-forward and simple to operate. It monitors a number of pressure and temperature points and returns the engine to 100% diesel operation should any parameter deviate from its normal range. In addition, a hourmeter function tracks the operating hours in bi-fuel mode. Alarms are annunciated in clear message form and the controller maintains an alarm log of the last 100 events.

GTI Step Control System (STEPCON )* The STEPCON System is an option to the basic GTI Bi-Fuel System. STEPCON retains all of the components of the basic fumigation system with the addition of a Gas Control Manifold (GCM), kw sensor, and a panel upgrade with customized firmware and outputs. The STEPCON enhances the standard bi-fuel system, allowing its application over a wider load range, adjusting the optimal substitution step based on load with the capability to make substitution level adjustments in response to rapid load changes. The design requires no modifications to the diesel engine, controls, or sensors, and uses all of the same basic safety systems to protect the engine. The STEPCON system incorporates a kw sensor to enhance its ability to sense engine load, and a gas control manifold (GCM) assembly, installed directly on the outlet side of the gas train. The GCM incorporates a standard manual power valve in parallel with three single-solenoid fuel control valves, each of which has a manually set, fully adjustable orifice that is set by the commissioning technician. A standard GTI Bi-Fuel commissioning procedure is performed for the load window where the lowest level of substitution will take place, with all three solenoid valves electrically closed, using only the manual power valve to set this lowest (initial) level of substitution. The commissioning procedure is repeated for the second, third, and fourth stepped levels of substitution, each time setting the percent of substitution for its corresponding load window by adjusting the variable orifice of each solenoid valve. Customized software is used to create ON/OFF combinations of the three solenoid valves in the gas control manifold to shape the gas substitution curve to follow the engines tolerance to gas as engine load is varied across a wide range, providing optimized substitution over a wide load band. The result is a load map that allows the GTI control panel to rapidly transition to the selected valve combinations based on engine load, thus maximizing the benefits of the bi-fuel application. Gas.5-4psig STEPCON Applications The STEPCON System is intended for use in applications where there is a need to accommodate adjustments in the optimal substitution rate as a result of changes in conditions that would normally require a limitation to the maximum possible substitution over a given load window; or a limitation to the maximum possible load window with a given rate of substitution. An example would be an installation where high operating temperatures (either time-of-day or load related) limit the substitution at elevated loads. Another example is a genset that spends a large percentage of its time at light load, below the point where a standard bi-fuel system optimized to operate in the engine s moderate-to-heavy load region would be in the bi-fuel OFF condition (such as on a drill rig). STEPCON Sizing The STEPCON system is available in a number of models to accommodate various engine configurations. STEPCON Fuel Control Manifold Size Chart GCM Inlet Flange Outlet Size Outlets STEP65115 DN65 1.5" JIC 1 STEP65215 DN65 1.5" JIC 2 STEP65415 DN65 1.5" JIC 4 STEP80120 DN80 2.0" JIC 1 STEP80220 DN80 2.0" JIC 2 STEP80420 DN80 2.0" JIC 4 Experience You Can Count On Altronic began the promotion and sale of the GTI Bi-Fuel System in 2002, long before most genset operators had heard of such application, or before many had enjoyed the benefits that it offers. Since then thousands of systems have been installed throughout the world in a wide range of applications and operating environments. A dedicated network of independent Master Distributors and Dealers, fully supported by Altronic, offers local installation, commissioning and maintenance. *Patent Pending

Bi-Fuel Kit Application and Contents GTI Series Engine Power Rating Engine Type Gas Mixers 1 Series No. Vibration Sensor(s) STEPCON Option Up to 75 kwe In-line engine 1 x 3" 2513 NA NA No 25 3 2514 NA NA No 75-150 kwe In-line engine 1 x 4" 2514 Optional (1) NA No 50 65 75-150 kwe In-line engine 1 x 4" 150-300 kwe In-line engine 1 x 5" CSA Certified 2 5014 NA NA No 5014 Optional (1) NA Yes 5015 NA NA No 5015 Optional (1) NA Yes 300-600 kwe In-line engine 1 x 6" 6516 Standard (2) Optional Yes 600-1200 kwe 80 1200-3000 kwe V-engine, common manifold V-engine, dual manifold V-engine, quad manifold V-engine, common manifold V-engine, dual manifold V-engine, quad manifold GTI+ Up to 1.2MW 4 In-line or V-engine, single, dual or quad manifold 2 x 6" 6526 4 x 6" 6546 2 x 6" 6526 4 x 6" 6546 2 x 6" 6526 4 x 6" 6546 2 x 7" 8027 4 x 6" 8046 4 x 7" 8047 2 x 7" 8027 4 x 6" 8046 4 x 7" 8047 2 x 7" 8027 4 x 6" 8046 4 x 7" 8047 Size and quantity as required Standard (2) Optional Yes Standard (2) Optional Yes GTI+ Standard (2) NA Yes 1 Mixer sizes can be incorporated as required by engine air inlet piping size. 2 CSA Certified Class I, Div. 2, Group D System available. Contact Altronic sales office for details. 3 Series 25 kits require 12Vdc Power; all other Series require 24Vdc power. 4 At 3psi supply pressure. Contact your distributor for larger applications. C US 712 Trumbull Avenue Girard, Ohio 44420 USA P: 330-545-9768 F: 330-545-3231 Form GTI 3-14.2