Standard offering (pumps)



Similar documents
CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Vertical selfpriming Side-Channel Pumps Type WPV

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Vogel - Multistage Pumps Design MP, MPA, MPB, MPV Sizes DN 40 - DN 125

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

CE Marking to BS EN

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

ALIGNMENT. Pump and Driver Alignment

CRK A-W-A-BUBV

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Multistage high-pressure multistage centrifugal pumps

How To Pump A Pump

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

Model 413 AURORA. 410 Series SINGLE STAGE SPLIT CASE PUMPS

Transformer oil cooler ALFA A02

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS

Series description: Wilo-Drain TC 40

BASIS RANGE TMB SERIES

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

Vertical Multistage Centrifugal Electric Pumps SV Series NEW LASER TECHNOLOGY

Horizontal Jet Pumps 1/3-1-1/2 HP

Rules for Classification and Construction Additional Rules and Guidelines

VAD Variable Area Desuperheaters

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Flygt 3068, 50Hz. Technical Specification

4" SUBMERSIBLE PUMPS

The conditions below apply to the curves shown on the following pages.

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

SJT / SJM / SJP Large Vertical Pumps

Model 1210C Battery Powered Pump Shown. Description

ROBOT PUMPS RT - TURBOTEX PUMPS

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

V47 Series Temperature Actuated Modulating Water Valves

FAN & BLOWER CENTRIFUGAL FANS

Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Pumps SELECTION OF A PUMP

MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL.

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

Inline Pumps Type NCV / NCVL

IMPORTANT SAFETY NOTICE

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

AFE424 SERVICE PARTS

SIGMA GROUP a. s. Divize průmyslová čerpadla

Operataing Manual. Single stage radial Fan. Model MKV/TKV

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX Q [US gpm]

We will discuss common industrial applications with guides for the proper use of electric motors on these.

VAD. Variable Area Desuperheaters

ECOCIAT. Domestic hot water heat recovery unit

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

Butterfly Valves PN 6/10/16 for flanged connection

THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

MICRO HYDRO POWER GENERATING EQUIPMENT

MEMBRANE VACUUM MINI PUMPS

Approval Standard for Centrifugal Fire Pumps (Horizontal, End Suction Type)

MODEL INSTALLATION INSTRUCTIONS

MDT5N25 & MTD5N40 SERVICE PARTS

Dry Pit Solids Handling Pumps

IN series. Centrifugal pumps standardized to DIN-24255

KEYSTONE. Stainless steel hygienic butterfly valves F250 for imperial tubing F251 for metric tubing

Conlift1, Conlift2, Conlift2 ph+

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN

PUMP VIBRATION STANDARDS GUIDELINES

OHV / OHVL Type OH3 Vertical Inline Pumps ISO (API 610)

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

HIGH SPEED SPINDLE MOTORS

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

Vertical Pumps for the Oil & Gas Industry

MULTISTAGE CENTRIFUGAL PUMPS

Flygt Ball Check Valves

VERTICAL TURBINE AND PROPELLER PUMPS

API Flanged Safety Relief Valves Series 526 CATALOG

SUPER-TITAN. Split-case pumps with power, performance and reliability for a world of applications

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Oil and Coolant Circulating Heating System. Model - OCSM

AC Electric Motors best practice

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

Transcription:

MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) info@mdmpumps.co.uk www.mdmpumps.co.uk Any information given with a quotation, such as an MDM pump data sheet, MDM Documents and Nameplates sheet, quotation cover letter or e-mail, will supersede this information. 1. Pricing Issue 2, May 2015 All quoted prices are nett, ex works, VAT extra. Delivery prices quoted to UK mainland exclude the Scottish Highlands. Equipment in Ireland and The Netherlands will only be supported locally if it is ordered through our distributor in the country in question. For this reason, if equipment is required for one of these countries, then a quotation should be obtained from our distributor, not directly from MDM Pumps Ltd. For quotations involving more than one off pump, prices are based on the assumption that all pumps will be ordered. Carriage and despatch are based on all pumps being delivered in a single consignment. 2. Metal parts (excluding motor) All wetted metal parts will be stainless steel to AISI 316L (1.4404) except for those in the mechanical seal, which will typically be stainless steel 316. See Materials of construction document. Mechanical seals See section 4. Joint rings (static seals) 3. Non-metal parts (excluding motor) Pump range Joint rings Section Material H, CH Cover joint ring + impeller joint ring L Silicone 70 FDA D1 - D6, GP, TWO-WAY Cover joint ring only O ring Silicone 70 FDA CR Cover joint ring + impeller joint ring O ring EPDM (not FDA*) *FDA-compliant EPDM available on request. Sacrificial seals The user should assume that seals will not withstand a passivation/degreasing process. Contact MDM Pumps Ltd for advice. Spare/sacrificial seals are not supplied as standard but can be supplied for an extra charge. Other Acoustic cowls will be lined with acoustic foam. Details available on request. Page 1 of 5

4. Mechanical seal Each pump will be fitted with a single internal mechanical seal with bellows (non-pusher design). Rotating component Stationary component Pump range Bellows Face Seat Seat type / material H with John Crane T2100 EP FDA Carbon Silicon carbide Cup EP FDA CH with John Crane 515H Inconel (Alloy 718) Carbon Silicon carbide O ring EP FDA D2 - D6 with John Crane T2 EP FDA Carbon Silicon carbide Cup EP FDA D1X with John Crane 6J Nitrile (not FDA) Carbon Ceramic Cup EP (not FDA) GP, TWO-WAY with John Crane 6D Butyl (not FDA*) Carbon Ceramic Cup EP CR with Roten T82 EP FDA Ceramic Carbon O ring EP FDA *FDA-compliant EP available on request. 5. Connections and fittings Suction (inlet) and discharge (outlet) Pump size* Suction (inlet) Discharge (outlet) Fittings type 1 (D or GP range) 1 1 25 (H range) 1.5 1 1.5 /40 1.5 or 2 1.5 2 /50 2, 2.5 or 3 2 RJT male BS 4825 : 1991, Part 5 3 /80 3 or 4 3 4 /100 4 3 or 4 5 /125 5 5 6 /150 6 6 8 /200 8 8 Flanged BS EN 1092-1 *The pump size gives an indication of the size of pipework for which the pump was designed. For D and GP pumps imperial measurements (eg 1.5 ) are used whereas for H and CH pump metric measurements (eg 40) are used. The pump size is the beginning of the pump model name so, for example, both the 1.5 D6A and 40H261 pump models have been designed for duty flows typical of 1.5 /40mm pipework. BS 4825 : 1991, Part 5 supersedes BS 1864 : 1966. BS EN 1092-1 supersedes BS 4054. Connection sizes shown are for guideline purposes only. On occasions it may be necessary to supply different connection sizes in order to meet other requirements. Mating connections are not supplied as standard but can be supplied for an extra charge. Drain Drains are not supplied as standard but can be supplied for an extra charge. See Options document. Self-Priming ( SP ) reservoir CR liquid ring pumps have a built-in self-priming reservoir as standard. Centrifugal air separator ( AS ) pumps are not self-priming as standard, but can be manufactured with self-priming reservoirs for an extra charge. Page 2 of 5

Impeller Impeller type Fully open Radial (semi-open) Closed* Pump model GP, CR TWO-WAY, D1X, D2, D121, 40-150H141-H261 All centrifugal Air Separator ( AS ) pumps D3, D4A, D5A, D6A, 25H141-H261 *Volute pumps (pumps whose model name contains a V ) will typically be fitted with radial impellers when run on 4-pole or 6-pole motors. 6. Surface finish Standard finishes are shown below: Pump model Internal finish (wetted parts) External finish H, CH, D, GP Uniform (as machined, max.* 3.6µm R a, 140µin R a ) As machined CR Uniform (as cast, approx. 3.2µm R a, 125µin R a ) Electropolished *Not guaranteed unless requested. Pure or electropolished internal finishes are not supplied as standard but can be supplied for an extra charge. See Options document. Duty point tolerances 7. Pump duty For flooded suction centrifugal pumps and for liquid ring pumps, we guarantee that at the duty flow the pump will deliver a differential head that is: Within ±5% of the duty head, if the head is greater than or equal to 28.2m (40 psi of water at 22 C); Within ±1.4m (±2 psi of water at 22 C) of the duty head, if the head is less than 28.2m. For centrifugal air separator ( AS ) pumps, we guarantee that at the duty head the pump will deliver a flow that is at least as great as the duty flow. Tolerances will be shown in the test box on the MDM pump data sheet. Design pressure / maximum allowable working pressure The maximum allowable working pressure will be as indicated in section A of the generic instruction manual. Copies are available on request. Upper temperature limits Design temperature* Unless otherwise stated, standard pump-and-motor units have a design temperature of 140 C, which means that they will be suitable for steam sterilisation up to 140 C with the pump stationary. Maximum allowable working temperature* The upper limit on the maximum allowable working temperature is 95 C for a standard pump-and-motor unit. *See Upper temperature limits document. Pumping of solids The maximum size of deformable particles (eg lumps of yeast) than can be handled by a centrifugal pump is typically equal to the impeller vane width (except for GP pumps), and the maximum size of non-deformable particles (eg hop seeds) is half this. The impeller vane width will be shown on the MDM pump data sheet. As a guideline, all of our centrifugal pumps can handle deformable particles up to at least 6mm and nondeformable particles up to at least 3mm, unless the vane width on the impeller has been trimmed. (D pump vane Page 3 of 5

widths are occasionally trimmed.) See the Pumping solids document for further information. Liquid ring pumps are generally not recommended for pumping solids unless the particles are very fine, because of the small clearances between the impeller and pump casing. Mounting 8. Motors and mounting Mounting will be standard (motor foot only). Motor feet will have bolt holes. Free-standing bases, cowls or trolleys are not supplied as standard but can be supplied for an extra charge. See Options document. Dimensions and orientation General arrangement drawings are available. We assume that pumps will be mounted with the pump inlet (suction) and shaft oriented horizontally and with the pump outlet (discharge) oriented vertically, pointing upwards. In this orientation the pump outlet will be on the righthand side when viewed from the front. Motor Pumps will be fitted to asynchronous squirrel cage AC induction motors of the following specification: Zone/Area: Suitable for a safe/non-hazardous area Ingress Protection: IP55 External Finish: Standard (normal paint). Paint will not be FDA-approved*. Internal Finish: Standard (no extra internal tropic-proofing) Supply: Suitable for a 400V±5%, 3 phase, 50Hz supply. These motors can also be used with a 460-480V 60Hz supply. Frame Material: Motors with a 180 frame (eg 22kW, 2 poles) or less will typically have an alloy frame. Motors with a 200 frame (eg 30kW, 2 poles) or larger will have a cast iron frame. Efficiency Class: IE2 for 0.75-5.5kW and IE3 for 7.5kW+ (IE2 if the pump will be run with an inverter) Thermal Class: Insulation: Thermal Class F (155 C); Temperature rise: Thermal Class B (80 C). Vibration Level: N (normal). Bearings: C3, ball bearings, suitable to +110 C. Lubrication: Bearing grease will not be FDA-approved. Bearings will typically be sealed for life. Cooling Method: IC 411 (self-ventilated) = TEFV/TEFC (Totally-Enclosed Fan Ventilated/Cooled). Shaft Length: Standard Poles: Motors fitted to centrifugal pumps will typically have 2 poles (nominally 2900 rpm). 4- pole (nominally 1450 rpm) and 6-pole motors can also be used on the centrifugal pumps. Motors fitted to liquid ring pumps will always have 4 poles. *Even if compliance with ASME BPE is requested. Motors are purchased with standard shafts, which for some H, CH, D and GP pumps are then modified to suit the pump. Motors will not be fitted with thermistors as standard, but these can be supplied for an extra charge. Unless you explicitly request a particular motor manufacturer, MDM Pumps Ltd will select whatever manufacturer we believe to be suitable. Our standard offering is typically AEG-Lafert. Quotations for pump kits (bare-shaft pumps) do not necessarily include the motor adaptor plate. Please enquire if this is not explicitly stated in the quotation. Lifting points Pumps will not have lifting lugs. For lifting instructions see page B1 of instruction manual. Page 4 of 5

Documents 9. Documents, nameplates and testing Documents supplied as standard 1) MDM data sheet (to be sent with the order acknowledgement). 1 off per data sheet 2) Generic A5-sized instruction manual (tied to pump). 1 off per pump Section A: Section B: Section C: Section D: Section E: Section F: Section G: Section H: General Transport & Storage Description of Pump Installation & Assembly Operation Maintenance & Servicing Faults causes & remedies EC declaration of conformity* 3) MDM data sheet (included with the instruction manual). 1 off per pump 4) Parts list (included with the instruction manual). 1 off per pump Notes: All documents, test results and nameplates listed above are included in the quoted price. Documents (2), (3) and (4) listed above will be shipped with the pump. Documentation will be in the English language only. Documents will be supplied printed and unbound. Electronic documents are not supplied as standard but can be supplied for an extra charge. Customisation of documents (eg the addition of title blocks or blank areas) will incur an extra charge. *Pump kits (bare-shaft pumps) are classified as components, rather than complete equipment, and therefore will be supplied with an EC declaration of incorporation. In order for a pump to be CE-marked, documentation must be written in the language of the destination country. If translation is required this will incur an extra charge. Nameplates Each pump will be fitted with a standard MDM nameplate, which will show the MDM logo, pump model (includes motor power), pump serial number, year of manufacture, nett weight and CE mark. Customised nameplates are not included in the quoted price. Testing All complete pumps will be hydrostatically and performance tested and will be CE-marked. Pump kits will be hydrostatically tested, but will not be performance tested as standard. Performance testing can be carried out for an extra charge. 10. Standards Our quality system conforms to ISO 9001:2008. All pumps comply with the relevant essential health and safety requirements of the EU Machinery Directive 2006/42/EC. See Pump Standards document. Page 5 of 5