Climate chamber with illumination



Similar documents
Material test chamber with mechanical convection

Incubator with mechanical convection

Heating oven with mechanical convection

Heating oven with mechanical control

Vacuum drying oven for non-flammable solvents

VDL 53 - Vacuum drying oven for flammable solvents

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

STD - STANDARD VERSION extended possibilities reasonable price wide range of optional equipment

40 Vacuum drying ovens

WATERBATHS AND OILBATHS

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

CRAC Precision climate control units for data centres

Thermo Scientific Heratherm Microbiological Incubators. Safe,

Weiss Mobile Air Conditioning Systems

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Freezers - Ultrafreezers. Platilab & Irilab Series

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Thermostatic Equipment

Climate Test Chamber. System Weiss. Type WK3-2000/40

LABOKLAV. Autoclaves Made in Germany.

Power consumption (kw)

Digital inductive conductivity transmitter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Blood Bank Refrigerators according to DIN Blood Plasma Freezers according to DIN 58375

Description. Dimensions. Features. precision works better

German engineering under high pressure

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

TMS TANK MANAGEMENT SYSTEM

AIR DEHUMIDIFYING Condensation drying for industry and trade

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

Series 6000 Torque measured metal bellow coupling

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Thyristor-controlled power supplies and battery chargers

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

LyoBeta. R+D Freeze-Dryers

Waterbaths and Oilbaths WNB/WNE/WPE/ONE

How To Make A Fronius Cl Power Inverter

Dehumidifier D 850E. - Instruction manual version 02

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

Installation, operation and maintenance manual TX 35A

CLIMACELL EVO. Climatic Chamber with Forced Air Circulation, Cooling and Controlled Humidity. Innovative Heat Technology. protecting human health

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Electronic Control Devices The European Product Catalogue 2007

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Specials. designed. 3rd edition 2015 English. for scientists 1

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ECOCIAT. Domestic hot water heat recovery unit

Classic Tylö sauna heaters for domestic use.

How To Use A Ds340 (Dsp)

COMBIMASS. Technical Data COMBIMASS eco-bio +

Sterilizers with extra class

MCR1900 Media Converter 19-Slot Chassis

Digital Ultra-Low Temperature Freezer. Digital Ultra-Low Temperature Freezer, Dual SHFS TM, Chest Type. Dual SHFS TM, Upright Type

Barcode Reader Series BCL 31, BCL 32, BCL 34

Product-friendly and fast...

User and installation manual

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Program Summary. Fluid & Motion Control Filtration & Fluid Management Sensors & Measurement

Professional Kitchens

Cliniklav 25. For highest quality in surgical applications MELAG. Evidence Based Sterilization

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

The power of innovation. For better media preparation. Media preparators Systec MediaPrep.

BR I Blood Bank Refrigerators

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

ENAiKOON ultrasonic fuel-level sensor

STERILIZERS, LABORATORY DRYING OVENS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ATL Fuel Level Sender Probes

List of instruments required for Innovation Projects sanctioned in Deshbandhu College for the year

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

Electronic Pressure Switch EDS 300

Solenoid valves Type EVU

2 Rittal Micro Data Centre

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Open channel & partially filled pipe Ultrasonic flow meters

HEAVY DUTY STORAGE GAS

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

French Door Refrigerator E23BC78IPS professional series

OT 40L / 90L. Laboratory Steam Sterilizers

API Marine. BMS Presentation. Ballast Measurement Systems

Capteur température et humidité pour HVAC

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Transcription:

KBWF series (E5.2) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows this climate chamber to create constant lighting and temperature conditions. Advantages: Homogeneous light distribution Natural growth conditions Temperature, humidity & light in one unit Areas of application: Cosmetics Industry Plant / Insect Growth Packaging Industry

Customer benefits Features Customer benefits Characteristics APT.line climate technology Same test conditions throughout the chamber interior Independent of specimen size and quantity No drying out of specimens APT.line Constant and gentle circulation of air through large-surface side walls even under a full load Homogeneous climate conditions throughout all specimens Light Cooling system Water supply Humidification system Standard equipment Unit design Accessories and Services Up to 20% greater usable space Light sources adjustable to specimen sizes Same irradiation results throughout the chamber interior Reliable testing independent of ambient conditions Flexible water management Easy plug-and-play handling Very accurately measured values Minimal maintenance requirements Safe, reproducible attainment of test results No extra costs Chamber is easily moved on casters Minimum space requirements Easy assembly Large chamber interior volume Easy cleaning Complete solution Everything from one source BINDER Service is always nearby Flexible positioning and fully removeable illumination cassettes Excellent light uniformity for all specimens on the entire shelf Different light spectra can be used Powerful compressor cooling system with large power reserves for lighting applications No freezing thanks to double evaporator plate Carefully measured cooling Direct connection to the domestic water system External water supply via tap or tank Water treatment with BINDER PURE AQUA SERVICE Sewage pump for discharges up to 1 m in height Back Pack System Vapor pressure humidification for fast response times Drift-free, capacitive humidity sensor Short recovery time after door opening Comprehensive standards Communication interface Access port diameter 30 mm BINDER test certificate Casters Inner glass door and double outer door seal Door heated against condensation ptimal ratio of usable space and footprint Large access area thanks to wide design Chamber interior made out of high-quality stainless steel Closed illumination cassettes No permanent fixtures Comprehensive product portfolio Various options: BINDER Data Logger Kits, access ports in various sizes and positions, control and documentation software APT-CM Years of proven and recognized validation and documentation materials Worldwide service network BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Performance characteristics Electronically controlled APT.line preheating chamber assuring temperature accuracy and reproducible results Temperature range 0 C to 70 C (without humidity and illumination) Temperature range 10 C to 60 C (with humidity and illumination) Humidity range 10 % to 80 % RH (without illumination) Humidity range 10 % to 75 % RH (with illumination) 2 variable positioned illumination cassettes with 5 daylight illumination tubes, each, in steps switchable The patented illumination system assures an unique homogeneous light distribution MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments for programming of day and night cycles Integrated electronic chart recorder Variety of options for the graphic display of process parameters Real-time clock Controlled humidification and dehumidification system with capacitive humidity sensor Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm Access port Ø 30 mm, left side Inner glass door Safety connection kit for water supply and drainage, including water hose, total length 6 m RS 422 interface for use with optional GMP/GLP and FDA guideline 21 CFR Part 11 compliant APT-CM DataControlSystem software 2 stainless steel racks BINDER test confirmation BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Specifications KBWF 240 (E5.2) Exterior dimensions Variable position illumination cassette Housing Width (mm) 925 Height (incl. feet/castors) (mm) 1465 Depth (plus connections and fittings) (mm) 800 Depth (incl. connections and fittings) (mm) 850 Wall clearance, rear (mm) 100 Wall clearance, side (mm) 100 Steam space volume (l) 348 Number of doors (ea.) 1 Illumination with 3 bright white and 2 BINDER Synergie Light fluorescent tubes Temperature-humidity chart without illumination Inner glass door(s) (ea.) 1 Interior dimensions Width (mm) 650 Height (mm) 785 Depth (mm) 485 Interior volume (l) 247 Racks (number standard/max.) 2 / 7 Load per rack (kg) 30 A: Guaranteed condensation free range / B: Temporary usable operation (up to 24 h) Temperature-humidity chart with illumination Permitted total load (kg) 100 Weight (empty) (kg) 214 Variable position illumination cassettes 2 Temperature data (without humidity) Temperature range without illumination cassettes ( C) 0-70 Temperature range with illumination cassettes with illumination ( C) 10-60 Max. heat compensation up to 40 C with illumination (W) 400 A: Guaranteed condensation free range / B: Temporary usable operation (up to 24 h) / C: Deviation of technical data may be possible Climate data (with humidity) Temperature range without illumination cassettes ( C) 10-70 Temperature range with illumination cassettes with illumination ( C) 10-60 Temperature variation with illumination (± K) 0,5-1,0 Temperature fluctuation with illumination (± K) 0,1-0,5 Humidity range without illumination cassettes (% RH) 10-80 Humidity range with illumination cassettes, with illumination 10-75 BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Specifications Humidity range with illumination cassettes, with illumination (% RH) 10-75 Humidity fluctuation with illumination (± % RH) 2 BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

Specifications KBWF 240 (E5.2) Heat compensation without illumination Illumination data per light cassette Daylight tubes (Lux) 9.000 Daylight tubes (W/m²) 24 Fluora growth lamps (Lux) 7.500 Fluora growth lamps (W/m²) 23 Arabidopsis tubes (Lux) 11.000 Arabidopsis tubes (W/m²) 32 Heat compensation with illumination Electrical data IP protection class acc. to EN 60529 IP 20 Voltage (± 10 %) 50 Hz (V) 200-230 Nominal power (kw) 2,4 Energy consumption at 37 C / 75 % RH 1) (W) 600 (9x20-0166), 660 (9x20-0251) Light spectrum Noise level approx. (db (A)) 52 1) These values can be used for dimensioning air condition systems. All technical data are specified for units with standard equipment at an ambient temperature of 25 C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time. BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

ptions BINDER PURE AQUA SERVICE BINDER PURE AQUA SERVICE is used to treat or fully desalinate tap water if the water quality is insufficient. The ion ex-change system consists of a housing, an integrated filter cartridge and a filter head. The digital quality-monitoring system is integrated in the filter head of the BINDER PURE AQUA SERVICE and uses 10 LEDs to display the current operating condi-tion of the filter medium. BINDER Data Logger Kits The new BINDER Data Logger Kits Makes independent recording of temperature and humidity data in the BINDER device possible. The tailored product solution contains helpful accessories: from mounting the logger to the BINDER device to cable access assistance to the sensor mount External water supply set External water supply set from fresh and waste water container, wiring and pump APT-CM DataControlSystem GLP Edition Software for GLP-compliant control, programming and documentation. Allows networking of up to 30 devices or controllers. Meets FDA 21 CFR Part 11 requirements Access port With silicone plugs for introducing external measuring instruments into the chamber, access ports with 30, 50 or 100 mm diameters Calibration certificate & validation BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany

ptions KBWF 240 (E5.2) Access ports with silicone plug 30, 50, 100 mm Securing elements for additional fastening of racks (1 set of 4 pieces) Keyboard lock Ethernet interface for communication software APT-CM DataControlSystem External fresh water supply set consits of fresh and waste water tank with 20 liter each, cabling and pump BINDER PURE AQUA SERVICE Disposable cartridge for BINDER PURE AQUA SERVICE Factory calibration certificate for temperature and humidity. Measurement in center of chamber at 25 C / 60 % RH or at specified values Extension to factory calibration certificate for temperature and humidity. Each additional measurement at an additional measuring point or set of values Temperature precision measurement according to DIN 12880 and 9-point humidity measurement / factory standard with measurement log and certificate, measured at 25 C / 60 % RH or at specified values Data Logger Kit TH 70: For the continuous temperature and humidity recording of -40 C to 70 C / 0 % to 100 % RH. Kit includes 1 data logger, 1 attachable combined humidity/temperature sensor with 2 m extension cable and 1 fixture for the connection at the BINDER unit Data Logger Kit TH 70/70: With two attachable combined sensors. ne for the continuous temperature and humidity recording of -40 C to 70 C / 0 % to 100 % RH. Second one at the data logger for recording the environmental conditions. Kit includes 1 data logger, 2 attachable combined humidity/temperature sensors with 2 m extension cable and 1 fixture for the connection at the BINDER unit Data Logger Kit T 220: For the continuous temperature recording of -90 C to 220 C. Kit includes 1 data logger, PT 100 sensor with 2 m Teflon extension cable and 1 fixture for the connection at the BINDER unit Data Logger Software: Configuration und evaluation software for all BINDER Data Logger Kits, incl. data cable (RS 232) Rack, stainless steel Shelf, perforated, stainless steel Reinforced rack, stainless steel, with 1 set of securing elements (1 set of 4 pieces), max. load 70 kg Vibration compatible shelf / platform (positioned at bottom level) to be mounted inside the chamber for shaker / spinner / roller operation. ther positions available on request 4-20 ma analog output for temperature and humidity measurements (e.g. chart recorder connection), with 6-pin DIN socket. utputs are adjusted automatically as the controller is adjusted Zero-voltage relay alarm outputs for temperature (±2 C) and humidity (±5 % RH), accessible via 6-pin DIN socket, with audible signal that can be switched off (maximum power rating 24 V AC/DC, 2.5 A) FLURA growth lamps set as replacement for the standard tubes for 230 V Arabidopsis fluorescent tubes set as replacement for the standard tubes for 230 V Replacement set of standard daylight illumination tubes for one illumination cassette Replacement set of FLURA illumination tubes for one illumination cassette Replacement set of Arabidopsis illumination tubes for one illumination cassette Locking door handle with key Temperature safety device, class 3.3 (DIN 12880) with optical alarm BINDER GmbH P Box 102 D-78502 Tuttlingen Address: Im Mittleren Ösch 5 D-78532 Tuttlingen, Germany