ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO. Central Control System

Similar documents
ACC-COM-LAN Communications Module (for Ethernet connections)

Do it Right. Save More.

ACC Advanced Commercial Controller

Efficient Irrigation via Smart Control. Rick Foster Sr. Product Manager

AdminToys Suite. Installation & Setup Guide

SRP. Controller Programming System for Commercial and Residential Irrigation Controllers. Owner s Manual and Installation Instructions

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

M400gsm GSM Modem Datasheet

Model Number(s): SRC, SRC Plus, Pro-C, ICC, XCORE, icore

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

NortechCommander Software Operating Manual MAN R6

VisiCount Installation. Revised: 8/28/2012

The software solution to complete your flow monitoring program

PLICSMOBILE: Measurement data via the mobile network

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

CamGuard Security System CamGuard Security System Manual

with SmartPort Connection Connection with SmartPort

Engineering and service software For KNX and LPB plants

Online Monitoring User Guide

Questions and Answers Regarding the Watering Index and ET (EvapoTranspiration)

Internet Central Control System

PM1122 INT DIGITAL INTERFACE REMOTE

Remote Monitoring and Satellite Communications

Think Automation and beyond... IDEC WindSRV. KEPServerEX OPC Server

Global GSM & Satellite Remote Monitoring

CMS Central Monitoring System

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

N600 WiFi USB Adapter

MODEM AND DIAL-UP. Installation/Configuration (Windows 95/98/Me/NT/2000/XP)

Wireless Soil Moisture and Weather Monitoring System Caipos

ENVIRONMENTAL MONITORING SYSTEM WITH WORLD-WIDE COVERAGE AND BIDIRECTIONAL COMMUNICATION VIA INMARSAT SATELLITE NETWORK

Weather Capture Software Guide Version 1.4 Revision: June

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Rain Bird IQ v2.0 Central Control

RACEAIR REMOTE PAGER SYSTEM

TEMP MONITOR_S2 Software operation instructions

Estação Meteorológica sem fio VEC-STA-003

Rev # OC-UG-EN-01 page 1 / 6. Datinf ObjectCounter Software Manual. Datinf ObjectCounter. Manual. Datinf GmbH Wilhelmstr Tübingen Germany

Wireless solutions for water and wastewater management

Global Water Instrumentation, Inc.

Somero SiteShape System

User Guide HUAWEI UML397. Welcome to HUAWEI

MOBILE CALL GSM Alarm System User s Manual

DIAL-UP DATA. User s Guide

Step by step guide to installing your own Ku Band satellite dish

TR-3 Channel Editor. Software Manual

Verizon Remote Access User Guide

SNMP-NET Client Shutdown Management Software for Windows 2000/XP/2003 User s Manual

WALL TABLET. Smart Home Controller. make your home smart. Control your home from anywhere in the world

GPS Vehicle and personal location tracker. User manual

SYSTEMS CALL CENTER GLOBAL RETAIL SOLUTION XWEB5000 XCENTER XWEB3000 XWEB500 - XWEB500D XWEB300D

SuperNav for Heavy Equipment

WiFi Edition

Infinity 2020 Perimeter Intrusion Detection System

mysensors mysensors Wireless Sensors and and Cellular Gateway Quick Start Guide Information to Users Inside the Box

WIRELESS SOLUTIONS. The Right Connection for. Make the Right Connection for Industrial Wireless Solutions

Complete SCADA solution for Remote Monitoring and Control

Web VTS Installation Guide. Copyright SiiTech Inc. All rights reserved.

Global Monitoring + Support

Optimizing Energy Operations with Machine-to-Machine Communications

ENGLISH. Land Phone Line Remote Communication Station Usage Manual. Please read this manual carefully, before starting to operate the station.

Home Security Alarm System

SafeMobile, Inc E. Algonquin Road, Rolling Meadows, IL Tel: (847) Fax: (847)

Allpro Insulator Insulation Contractor Software. Software Brochure. Provided By:

Temperature Datalogger Users Manual

Proving that extra smart can also be extra simple.

EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE

Product Specification instalert Rapid Messenger Variable Message Sign

Welcome to Hay Communications Enhanced High Speed Internet Service

Temperature Alert. LAN-based Temperature and Humidity Data Logger

Residential Irrigation Controller NEW. Owner s Manual and Programming Instructions Compatible with Hunter Remotes and Solar Sync RUN

DriveRight. Fleet Management Software. Getting Started Guide. CarChip. DriveRight. Drivers. Vehicles. Product #8186

SETTING UP A REMOTE MODEM CONNECTION Application Note 27

Quick Start Guide 3G Router from Vodafone

WorldTracker DIGITAL GSM REAL-TIME DATA LOGGING TRACKING SYSTEM. Owners Manual

Intelligent Vibration Monitoring

SatTerm-G SOFTWARE MANUAL FOR A3LA-IG

Practical Exercise on PC. Create Climate files Daily time step. Solution of the exercise

AMS Suite: Machinery Health Manager v5.4

Midland BT Updater BTUpdater Program Program file (x86) ), Midland

The EQ2 HEMS Enterprise Family of Products KEY FEATURES

TexasET Network Water My Yard Program

LB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia Tel/Fax 7(495) , Site:

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Is a specialized database application used by the manufacturing industry to reduce production costs by controlling tool usage, inventory, rework and

Updated: May Copyright DBA Software Inc. All rights reserved. 2 Getting Started Guide

Developer s Guide to Submetering Submetering Specifications for Multi-Housing Construction

Logitrac Fleet Tracking System

A6210 WiFi USB Adapter ac USB 3.0 Dual Band User Manual

IN DEFENSE OF OUR SCHOOLS

1. Installation of USB Driver under command of Windows Operational System

8.5 Using Your Phone As a Modem (Internet Sharing)

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

Automated Wireless Monitoring of Water Distribution Systems. A Telog White Paper

Computer Aided Dispatch & Mobile Digital Communicator

USB Edition TM-STD30 User Guide

NETWORK TECHNOLOGY. Long Range Radio Networks

Ericsson W25. Mobile Networks. Quick Installation Guide

Industry Ap plications

Enterprise Remote Monitoring

Transcription:

ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO IMMS 3.0 Central Control System

Open the Window to Your World Hunter s Irrigation Management & Monitoring Software (IMMS) is a proven software package that makes computerized central control of irrigation affordable, usable, and comprehensible. Since 2003, the software and hardware have been intensively developed and refined into an irrigation command and control masterpiece. With the IMMS 3.0 release, interactive map graphics (to station level) put the irrigation system manager in complete visual control of wide-area watering operations. IMMS is a Microsoft Windows-based application that is compatible with Windows XP, Vista, and Windows 7 (32- or 64-bit operating systems).

Maps The IMMS graphics update includes the ability to create one or more map views for control purposes. You can see where all of your irrigated locations are, and click any for a more detailed view or control purposes. Ideal for orienting new employees, IMMS Graphics also simplifies life for busy irrigators with large numbers of assets to control. Use any background image to show the system, site, or controller area, and create control zones and station symbols that link to their command functions. You supply the pictures, and IMMS includes all the tools you need to create an interactive map-based system. Programming Each controller has its own complete setup and operations screens with tools to quickly and easily get the results you want. Eliminate the confusion and hassle of multiple field personnel setting up irrigation with dials and buttons. Shut off irrigation with a mouse click for emergencies. Access every function of controllers from simple spreadsheets or choosing from a menu of common functions and commands.

ET Sensor These cost-effective sensors can be placed in different micro-climates and used to adjust other controllers in similar conditions. The IMMS-ET historical reports track climate data for analysis. IMMS-ET historical reports IMMS-ET (Evapotranspiration) Take the guesswork out of irrigation amounts and daily adjustments for weather conditions. The optional IMMS-ET software add-on uses cost-effective local sensors, combined with your station database (for plant types, soil, precipitation rate, and more) to create water-saving irrigation programs for your whole system, every day. IMMS-ET models the moisture level in soil reservoirs (including compensation for natural rainfall) and schedules just enough irrigation to replace what your plants need. IMMS-ET can track climate history according to your own sensors and document how it has responded with irrigation adjustments. Alarm Management IMMS reports all alarms, including over-currents, flow violations, communication issues, and water window violations, with individual date- and time-stamped messages. The IMMS operator knows the state of all irrigation controllers and valves at a glance, without driving around town to check individual sites. Printable reports can be exported to other formats or handed to work crews for investigation. Connect up to 100 Sites, with up to 100 Controllers Each A. remote Site Access with dial-up via cellular or landline connection wireless Share the link via hardwire cable or UHF radio B. local Site Connect the first controller with cable via CCC interface Share the link via hardwire cable or UHF radio master controller A. Remote Site hardwired cable central computer wireless master controller B. Local Site hardwired cable

Flow Monitoring Track your water usage, and spot plumbing problems a mile away (or several hundred miles away). IMMS is built around the powerful ACC controller platform, which includes real-time flow monitoring. With a flow meter and normally-closed master valves, the ACC detects incorrect flow conditions and moves swiftly to isolate the offending valves. Each flow violation is reported to the central software, after the controller has finished its own diagnostics. Leaks, breaks, and flooding are minimized, and the irrigation manager is the first to know of any issues. IMMS also tracks total water usage by site, controller, program, and station. Keep detailed historical records, and go home each day with the peace of mind that automatic flow monitoring gives. Central Computer: During routine monitoring schedule, IMMS computer program contacts the controller and is notified of time and date of master valve shut down. 01 Flow Sensor (HFS): Flow rates monitored and reported. 02 ACC Controller: Recognizes high flow, issues shut-down command. 03 Master Valve: Water flow shut down. 04 Case Study: IMMS in Sports Turf Application We spent $15,000 and it saved $55,000, says Grounds Manager Chris Ralston of the IMMS-ET at his baseball stadium in Lake Elsinore, CA. Now with the Sacramento River Cats, the AAA team for the Oakland Athletics, Ralston is making sure the capital city sees the same kind of savings. Ralston needs a good system: In Sacramento, he has 82 irrigation zones, including turf, rosebeds, shrubbery, and trees. His four-employee operation (plus 20 seasonal workers) has to keep everything green for the 72 home games plus numerous concerts and events that the stadium hosts. So simplicity is key, and Ralston relies on the IMMS-ET. I think the best feature is the fact that it has an ET sensor on it, says Ralston. With IMMS-ET, everything is on-site and acts as a weather station. Ralston explains the system s ease of use was a factor in his purchase decision. We have five clocks on site and it puts all five on them on one screen. I pick the start time and the computer does everything for me, he says. I double check it, but the fact that it hasn t failed me, the grass is green and I m saving 15 to 20 percent on water use means it s hard to go wrong. Sacramento River Cats baseball stadium in Sacramento, California

Specifications Software Models IMMS3CD: Central control software on CD, compatible with Microsoft Windows 7, Vista, and XP (requires minimum 512 Mb RAM and 1024 x 768 graphics resolution). Map images (not supplied) can be JPG, GIF, TIF, BMP, or PNG file formats. IMMS-ET: Optional ET water savings software add-on (requires one or more ET Sensors). Compatible Controllers ACC-1200 and derivatives, with communications modules (see on this page). ACC99D and derivatives, with communications modules (see on this page). ICC, Pro-C, and SRC may be added to IMMS systems with reduced features (using SI/CI interfaces) via the SmartPort connection. Communications Options IMMS central control may communicate via hardwired cable, professional two-way radio, dial-up telephone, and GSM cell phone. Other possibilities may exist in particular installations; check with Hunter Technical Support for specific applications. ACC-COM-HWR: Radio and hardwire connection only ACC-HWIM: Hardwire interface terminal RAD3: UHF radio (license required) ACC-COM-POTS: Dial-up telephone ACC-COM-GSM: GSM cell phone ACC-COM-GSM-E: GSM cell phone, international See Hunter System Design Guide for details or consult with Hunter Technical Support for specific applications. IMMS-SI- (HW or MOD): Site interface for SmartPort controller connection. IMMS-CI-HW: Controller interface for SmartPort controller connections. ModelS description notes IMMS3CD IMMS 3 Graphics central control software Custom images not included IMMS-ET-CD Optional ET automatic weather adjustment software (requires IMMS3CD base model) radio antenna options ModelS description IMMSANT2 IMMSANT3 IMMSANTYAGI3 RA5M Requires 1 or more ET Sensors at ACC controller locations CoMMuniCation options SPECIFY SEPARATELY ModelS options PurPoSe ACC-COM-HWR = Hardwire/radio module (blank) = No option Supports hardwire and radio communication options ACC-COM-POTS = Dial-up modem module (also supports radio & hardwire) ACC-COM-GSM = CSD cellular module (also supports radio & hardwire) EXAMPLES acc-com-hwr acc-com-pots acc-com-gsm - e Hardwire/radio module Dial-up modem module E = International frequencies CSD cellular module for international frequencies user installed options ModelS description PurPoSe ACC-HWIM Hardwire interface module, required for hardwire connections SPECIFY SEPARATELY Omni-directional antenna for plastic pedestal lid installation Omni-directional antenna for wall or pole mount installation High efficiency directional antenna for pole installation High gain omni-directional mast antenna for roof or pole installations Supports dial-up telephone line input, in addition to hardwire and radio communication sharing Supports GSM mobile input, in addition to hardwire and radio communication sharing (cell service required) SPECIFY SEPARATELY Provides surge protected terminals for hardwired cable connections RAD3 UHF radio module (North America), 450-470 MHz UHF radio module for wireless connections (license and antenna required and not included) RAD460INT UHF radio module (international), 440-480 MHz Consult factory for other international frequency ranges UHF radio module for wireless connections, international only (license and antenna required and not included) APPBRKT Communication bracket for plastic pedestals Holds com modules and accessories in plastic pedestal (not required in wall mounts) GCBL Cable for hardwired communications Connects controllers via ACC HWIM Accessories ET Sensor: Weather sensor for IMMS-ET, add as needed (1 per microclimate) to ACC controllers, includes sensors for solar, temperature, humidity, and rain. ET Wind: Optional sensor for local wind speed. HFS: Hunter Flow Sensor (1 per ACC controller) for flow monitoring. Use with FCT fittings for pipe diameter. Hunter Industries Incorporated 1940 Diamond Street, San Marcos, California 92078 USA www.hunterindustries.com INT-479 D 2/11