Power On: The light comes on when there is power to the system unit.



Similar documents
Hardware Information Managing your server, adapters, and devices ESCALA POWER5 REFERENCE 86 A1 00EW 00

DISASTER STRIKES. Are you ready?

Security Service tools user IDs and passwords

System i and System p. Customer service, support, and troubleshooting

Virtual Measurements & Control. Flip/Flop Filler

ecotton System Configuration White Paper

Software Installation

AS/400 Logical Partitions Hardware Planning Guide

IBM i Version 7.2. Security Service Tools

FIRE AND BURGLAR ALARM SYSTEM BASED ON Central Panel «KODOS A-20» User Guide

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

Your Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)

Esi-Mail. Setup and User s Guide. Visit for up-to-date help Rev. A

USING WIRELESS DIAGNOSTICS Application Note 31

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

M6310 USB Flash Drive Tester/Duplicator

How To Synchronize the easystore to the AD

D-MAX WEB GUIDE CONTROLLER WITH OPERATOR INTERFACE PANEL QUICK START SETUP MANUAL

H ARDWARE C ONSIDERATIONS

RDM+ Remote Desktop for Android. Getting Started Guide

Preparing a SQL Server for EmpowerID installation

Also on the Performance tab, you will find a button labeled Resource Monitor. You can invoke Resource Monitor for additional analysis of the system.

Robot SAVE 12 User Guide

Priority Pro v17: Hardware and Supporting Systems

ESM s management across multi-platforms eliminates the need for various account managers.

This chapter explains a preparation for the use of RemoteControlService.

System Operator s Guide. MaddenCo Inc. Revised August Copyright 2003 by MaddenCo, Inc All rights reserved.

Quick Installation and Setup for WinPower Software

Lab: Data Backup and Recovery in Windows XP

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

BorderGuard Client. Version 4.4. November 2013

Using the IPMI interface

TMA Management Suite. For EAD and TDM products. ABOUT OneAccess. Value-Adding Software Licenses TMA

Operating Systems Lab Exercises: WINDOWS 2000/XP Task Manager

13 Managing Devices. Your computer is an assembly of many components from different manufacturers. LESSON OBJECTIVES

Software Installation

LifeWays Operating Procedure

VMWare Workstation 11 Installation MICROSOFT WINDOWS SERVER 2008 R2 STANDARD ENTERPRISE ED.

Cisco SPA 500 Series IP Phones

SQL Tuning and Maintenance for the Altiris Deployment Server express database.

Analyzing IBM i Performance Metrics

Flagship Managed Solutions (FMS)

EZ DUPE DVD/CD Duplicator

How To Set The Sensor On A Powerpoint 3.5 (Powerpoint) On A Blackberry 2.5A (Powerplant) On An Iphone Or Ipad (Powerplant) On The Blackberry 3.2 (

Lab - Data Backup and Recovery in Windows XP

DSK MANAGER. For IBM iseries and AS/400. Version Last Updated September Kisco Information Systems 7 Church Street Saranac Lake, NY 12983

Exam Name: i5 iseries LPAR Technical Solutions V5R3 Exam Type: IBM Exam Code: Total Questions: 132

Configure the idrac Remote Access Console

Objectives. At the end of this chapter students should be able to:

User s Guide EKT-824

The Flash Express Feature on IBM zenterprise EC12 and z/os exploitation of flash storage

LinkPlus Interface Guide

Administrator s Guide

iseries Getting started with iseries

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

VTLBackup4i. Backup your IBM i data to remote location automatically. Quick Reference and Tutorial. Version 02.00

Chapter 10 Troubleshooting

eg Enterprise v5.2 Clariion SAN storage system eg Enterprise v5.6

Administrator s Guide

PowerSoftMD by Data Tec Backup Strategies

4 Backing Up and Restoring System Software

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

What you need to know to do successful IBM i upgrades to 7.2 (and 6.1 or 7.1)

46xx_47xx_1546_1547 RAID Recovery/Set Up Instructions

Fujitsu LIFEBOOK T Series

Using These Manuals. How to Use the. Software User Guide. Display examples: 1. Understanding How to Use Your Camera.

InsightPower Client. Shutdown Management Software for Windows 2000/XP/2003. User s Manual

Installation & Operations Manual

APP USER MANUAL. Trackunit Virtual Hardware. Status / Tracking / Map

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

SAMSUNG DCS Auto Attendant & ACD User Guide

CostsMaster. CostsMaster Dongle Server User Guide

MYASIA CLOUD SERVER. Defining next generation of global storage grid User Guide AUG 2010, version 1.1

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Chapter 3. Operating Systems

Time Stamp. Instruction Booklet

PC computer configurations & Windows optimizations (Updated November 2012)

ION EEM 3.8 Server Preparation

PRIMEQUEST Integration

PARTNER ACS R4.0 Remote Administration R4.0. Getting Started

Legal Notices. Guide Part Number REV A 2/10

RHINO TRACKS STANDARD GPS VEHICLE TRACKER

HotelTV. Client Software Update REV A0.10 D October. Web : Mail : support@vestek.com.tr Tel :

tattletale User Guide Consumer unit version P a g e

Protecting your SQL database with Hybrid Cloud Backup and Recovery. Session Code CL02

Installation Instruction STATISTICA Enterprise Server

Fundamentals of UNIX Lab Networking Commands (Estimated time: 45 min.)

SMS Alarm. User Manual

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

CINCINNATIR. A SUPPLEMENT to the OPERATION MANUAL FOR THE. For CINCINNATI Laser Control Software Version 8.3 CINCINNATI INCORPORATED

The Challenger Version 8 User Guide

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

Using RAID Admin and Disk Utility

Reborn Card NET. User s Manual

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

Chapter 6 The BIOS Setup Program

Transcription:

AS/400 Control Panel Functions System operators and service representatives can use the control panel to perform a number of tasks. You can use the control panel to do an initial program load (IPL) and problem analysis. The details of the control panels are described following the illustrations. Power On: The light comes on when there is power to the system unit. Note: The Power On light blinks when the system is being started up and when the system is manually turned off. When the Power Down System (PWRDWNSYS) command or the options on the Power On and Off Tasks (POWER) menu are used, the Power On light does not blink. Power pushbutton: You can press the pushbutton to start the system; press it again to stop the system. Attention: Using the Power pushbutton to turn off the system may cause results that cannot be predicted in your data files, and the next IPL will take longer to complete. Note: Power on is allowed in Manual or Normal mode, and Power off is allowed in Manual mode only. In most cases, use the Power Down System (PWRDWNSYS) command on any command line of your display station to stop the system. If you use the Power pushbutton to turn off your system, errors may occur with your data files. Processor Activity or Processor Active: Models 15x, 4xx, 60x, and some 62x System Units have one Processor Active light, and the light is on when programs are running. Models 5xx, 64x, 65x, and some 62x System Units have the Processor Activity lights that provide a graphical display of the processor activity. System Attention: This light comes on when the system requires operator attention, such as correcting a severe system failure. Function/Data display: The function number appears in the Function/Data display when you press the pushbutton (increment or decrement). Only the numbers of those functions that can be used in the present mode are displayable. This 8-character LCD display is used to: Display System Reference Codes (SRC's) when errors occur. Display valid functions to be performed. Display results of selected functions.

Increment/Decrement buttons: The Increment/Decrement buttons are used to cycle through the functions that are available in the current operating environment. If functions require additional input, these buttons also cycle through the valid selections within the function once the function is selected, and the Enter key is pressed. The Increment/Decrement buttons are used to change the IPL type and mode on systems without a mode button. The IPL type (A, B, C or D) and Mode (Normal, Manual) can be selected by using Function 02. To select IPL type and mode, do the following: 1. Use the Increment/Decrement buttons to select Function 02, and press the Enter pushbutton. 2. Use the Increment/Decrement buttons to select the IPL type and mode you want, and then press the Enter pushbutton to save. 3. You can also specify a fast or slow IPL that can only be set one time at the console panel when the system is powered off. Select Function 02 and press the Enter key twice. Then, use the Increment/Decrement buttons to select F(Fast), S(Slow), or V(System Value). Subsequent IPLs are determined by the system value. *MIN is the recommended setting, however, if you anticipate any hardware problems, specify *ALL on the Hardware diagnostics parameter. The

system value can be changed by using the Change IPL Attributes (CHGIPLA) command. Enter pushbutton: The Enter pushbutton is used to process the function or subfunction that is displayed in the Function/Data display. Mode: The mode button (only on systems with an electronic keystick) allows you to scroll through the four operating modes (Manual, Normal, Secure, and Auto) when the key stick is engaged. The active mode on these systems is indicated by which of the four lights is lit. For systems with keysticks, see Electronic Keystick Slot below. To change modes for systems without keysticks, do the following: 1. Use the Increment/Decrement buttons to select Function 02, and press the Enter pushbutton. 2. Use the Increment/Decrement buttons to select the mode, then press Enter. The Increment/Decrement buttons are also used to select IPL type. Electronic keystick slot: This slot accepts an electronic keystick that, when engaged, allows you to change operating modes. A system operator can prevent unwanted operations by selecting the appropriate mode and removing the keystick. (Available on selected AS/400 models).

List of System Reference Codes System Reference Code Starting with 11-3 What You Should Do 0000 AABB You attempted a timed, remote, or 0000 AACC automatic IPL with the system in the Secure or Manual mode. Set the system to the Normal or Auto mode and do the IPL again. 0000 AADD You attempted a manual IPL with the system in the Secure or Auto mode. Set the system to the Normal or the Manual mode and try the operation again. 1xxx D101 1xxx D102 63xx xxxx 93xx xxxx A6xx 500x A1xx xxxx B1xx xxxx A900 2000 B0xx xxxx B6xx xxxx Battery Power Unit x failed. Battery Power Unit x test failed. Replace the battery power unit. The tape unit failed. A disk or diskette Unit failed. Workstation controller failure. IPL load device failure. The IPL completed normally, Does the system console have a sign on screen? If the system varied on, check the QSYSARB job log for the message and follow the corrective actions indicated in the message. To view the QSYSARB job log, use the Work with Active Job (WRKACTJOB) command, and then select Option 10 (Display jobs) to view the job log. You need to have *QSECOFR authority to view the job log. Failure detected by communication Licensed Internal Code. Make sure the latest PTF package is installed. Not enough auxiliary storage. If your system unit has some

disk storage space available, add more to auxiliary storage pool 1. B9xx xxxx C1xx xxxx C3xx xxxx C5xx xxxx D1xx xxxx D6xx xxxx OS/400 installation failure IPL status. This is a normal indication during the IPL. You may suspect a hang or loop condition if the SRC does not change during the two-minute period Diagnostic status. This is a normal indication while the system main storage is being saved to disk. Diagnostic status. This is a normal indication while the system is being powered down. When xxxx is changing, the system is doing a main storage dump.

Mode Descriptions Manual: When the mode is set to Manual, the system allows you to do all manual IPLs, such as an operator-attended IPL from disk or tape, and manual control functions, such as select an IPL or display the kind of IPL that the system is set to run. However, you cannot do a remote IPL, an IPL by date and time, or an IPL after a power failure. Note: You should only set the mode to Manual when necessary. This will ensure that no one accidentally presses the Power pushbutton and causes the system to stop. Normal: Auto: The Normal mode allows you to manually turn the power on and to do each of the automatic operations. That is, you can start the system by doing a manual or remote IPL, an IPL by date and time, or an IPL after a power failure. If you want to stop the system when the mode is set to Normal, use the Power Down System (PWRDWNSYS) command at any display station. You must have QSYSOPR authority to use the Power Down System (PWRDWNSYS) command. The Auto (automatic) mode allows a remote IPL, an IPL by date and time, and an IPL after a power failure. When the mode is set to Auto, you cannot: Secure: Start the system by doing an IPL manually. Stop the system by using the Power pushbutton. Select a different IPL type by using the Increment/Decrement buttons. The Secure mode locks the control panel on the system unit. You can only stop the system from a display station by using the Power Down System (PWRDWNSYS) command.

IPL Overview The following table shows the system reference codes that are displayed and approximately how long they remain displayed while the IPL is progressing. In the diagram, x can be any number 0 through 9 or letter A through F. C1XX BXXX Input/Output processor testing (1-5 minutes) C1XX 1XXX Input/Output processor loading (1-10 minutes) C3XX 3XXX System processor testing (2-10 minutes) C1XX 2XXX System processor loading (2-10 minutes) C1XX 202E Testing system main storage (30 seconds-10 minutes, depending on size of main storage) C1XX D009 System power hardware ready (10 seconds) C1XX 2034 IPL control passed to system processor (10 seconds) C6XX 4XXX Testing system configuration (1-10 minutes) C6XX 4XXX IPLing OS/400 C6XX 4260 System disk data recovery C9XX 2XXX Operating system starting C900 29C0 Operating system (recovery)