Queen's University Environmental Health and Safety



Similar documents
HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Flammable Liquids Storage

Flammable Liquids Storage

Sample Written Program. For. Flammable Liquids

Flammable and Combustible Liquids. Slide 1 (of 23)

Notes. Material 1. Appropriate Flammable Liquids

ADMINISTRATIVE SERVICES MANUAL

OSHA Office of Training and Education 1

BP WIND ENERGY POLICIES AND PROCEDURES

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Flammable Storage in a Biotech Facility

FLAMMABLE LIQUIDS COMPLIANCE NOTE

3.2 The Department of Environmental Health and Safety is responsible for;

Flammable liquid classes: Combustible Liquid Classes. Class IC. Class II. Class IB F.P. below 22.8 C (73 F), boiling point at or above 37.

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

STORAGE AND HANDLING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 14.00: FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE SOLIDS OR FLAMMABLE GASES

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Section III Hazardous Materials Management

When Completed - Fax to (410)

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

FLAMMABLE AND COMBUSTIBLE LIQUIDS

Standard Operating Procedure: Flammable Liquids

Site and Storage Conditions for Class 3.1 Flammable Liquids

Mechanical Systems Competency 1.20

Ethanol Vehicle and Infrastructure Codes and Standards Citations

MOTOR FUEL DISPENSING SAFETY

OREGON FIRE CODE Interpretations and Technical Advisories

General Fire Code Requirements Within Commercial Tenant Spaces

September 2008 AFC (2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

Waste Oil Collection / Storage

Flammable Liquids 29 CFR

FDNY C14 Certificate of Fitness Quiz

Standard Operating Procedure

HAZARDOUS WASTE SATELLITE ACCUMULATION MANAGER RESPONSIBILITIES

7. Chemical Waste Disposal Procedures

HOT WORK PERMIT PROGRAM TRAINING. John Braun

Petroleum (Consolidation) Regulations 2014

Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation

SECTION FC 2706 NON-PRODUCTION CHEMICAL LABORATORIES

Wilkins Safety Group

Hazardous Waste Procedures. Faculty of Science University of Ottawa

February 2014 Alberta Fire Code Page 1 of 5. Fire Safety and Hand Hygiene in Healthcare Facilities

Compressed Gases The Dangers

Civil Engineering Sector Labour-Management Health and Safety Committee

Berea College Chemical waste/product Management Guide. October 2014

Queen s University Environmental Health & Safety

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

UCLA - Compressed Gas Cylinder Storage and Handling

A Code Review for Emergency Generators and Indoor Use of Portable Generators

Model Safety Program

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

Dip Tanks. RS 1030 (9/13) 2013 Nationwide Mutual Insurance Company Page 1 of 9 All Rights Reserved

University of Tennessee Safety Guidelines

Hazardous Waste Determination and Management Plan

Compressed Gas Cylinder Storage and Handling Guide

Compressed Gas Cylinder Safety

LPG, Flammable Liquids, Toxic and Corrosive Substances

HOT WORK PERMIT PROCEDURES

The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services

Presented by: Rich Perry Marsh Risk Consulting

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

RMM 501 Hazardous Materials Management Systems Including WHMIS Program Page 2 November 2014

LOCAL ARRANGEMENTS FOR WASTE DISPOSAL (BEGBROKE SITE)

How To Safely Handle A Spill

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Transportation of Dangerous Goods. Transportation of Dangerous Goods Training for Queen s University Shippers and Receivers.

OFM-TG Office of the Fire Marshal F M. Handling Flammable and Combustible Liquids in School Laboratories GUIDELINE

NFPA : Basic Requirements for Storage Tanks

The terms hazard and risk are often used, which we define as the following:

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

SPILL PREVENTION, CONTROL, AND COUNTER MEASURES PLAN (SPCC)

Disposal of chemical waste must be regarded as an integral part of all research projects and teaching programs involving chemical use.

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

Queen's University Environmental Health & Safety. 1. Introduction

Compressed Gas Cylinder Program

FUELING AND FUEL STORAGE

Safety Data Sheet Avesta Neutralization Agent 502

Arctic King Fuel Tanks meet the Environment Canada TECHNICAL REQUIREMENTS FOR COLLAPSIBLE FABRIC STORAGE TANKS (BLADDERS) - December 17, 2009

SPILL PREVENTION AND RESPONSE PLAN TEMPLATE FOR BUSINESSES IN DAYTON S SOURCE WATER PROTECTION AREA

Hazardous Waste Management Plan

LABORATORY SAFETY INSPECTION CHECKLIST

Fire & Explosion Risks in Service Stations

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

FIRE SAFETY ONLINE TRAINING

Director, National Institute for Occupational Safety and Health. California Fatality Assessment and Control Evaluation (CA/FACE) Program

Building Code Clarifications - 7. Fire Resistance

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Overview of Hotel Fire Safety Requirements

Lids, Leaks, Labels and Location All About Satellite Accumulation Martin E. Sánchez Principal Environmental Specialist

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment

Hazardous Waste Management Procedures

Transcription:

April, 2009 1 SOP-Chem-08 1.0 Introduction This document is intended as a guide to the Queen s University requirements for handling and storing flammable and combustible material in non-laboratories areas. For information regarding flammable and combustible liquids handling in laboratory environments, refer to the Laboratory Flammable and Combustible Liquids Handling Procedures (SOP-Chem-02). 2.0 Applicable Legislation Ontario Fire Code (O.Reg 213/07) Ontario Occupational Health and Safety Act (R.S.O. 1990) National Fire Protection Code of Canada National Fire Protection Association Guidelines ULC/ORD-C30 Safety Containers ULC/ORC-C1275 Storage Cabinets for Flammable Liquid Containers 3.0 Definitions Flammable Liquid: A liquid having a flash point below 37.8 0 C and having a vapour pressure not exceeding 40 psi at 37.8 0 C. Flammable liquids are also termed Class I, which are further subdivided in to Class IA, Class IB and Class IC. Class IA: Flash point below 22.8 0 C and a boiling point below 37.8 0 C Class IB: Flash point below 22.8 0 C and a boiling point at or above 37.8 0 C Class IC: Flash point at or above 22.8 0 C and below 37.8 0 C Combustible Liquids: A liquid having a flash point at or above 37.8 0 C. Combustible liquids can be subdivided into Class II, Class IIIA and Class IIIB. Class II: Flash point at or above 37.8 0 C and below 60 0 C Class IIIA: Flash point at or above 60 0 C and below 93.3 0 C Flash Point: The minimum temperature at which a liquid gives off vapour in sufficient concentrations to form an ignitable mixture with air near the surface of the liquid.

April, 2009 2 SOP-Chem-08 Fire Separation: Refers to a construction assembly (i.e. wall, door, etc.) that acts as a barrier against the spread of fire. The construction assembly may or may not have a fire-resistance rating or a fire-protection rating. A laboratory must be separated from other parts of a building by a fire separation having a fire resistance rating of 1 hour. Note: When a liquid having a flash point at or above 37.8 0 C is being processed, stored, handled or used at temperatures at or above its flash point, it must be treated as a flammable (Class1) liquid. 4.0 Purchasing Individual investigators or departments may purchase flammable liquids directly from external suppliers ONLY if the flammable liquids are in glass or metal containers of 5 litre capacity or less. 5.0 Dispensing 5.1 The dispensing of flammable and combustible liquids from containers larger than 5 litres must be performed in the Botterell Hall Dispensing Room (loading dock area). This presently is the only approved dispensing room on campus. Dispensing from containers larger than 5 litres in any other area is PROHIBITED. 5.2 Containers SHALL be grounded at all times during the dispensing process. 5.3 The fueling of gasoline engines on mobile or portable equipment must be conducted outdoors, with the engine stopped, no sources of ignition within 3 m and with an allowance for the expansion of fuel. Note: The transportation of flammable and combustible liquids requires care. Glass bottles (Winchesters) require special care when handling and it is recommended that a safety bottle carrier be used. 6.0 Storage 6.1 The storage, handling and use of flammable or combustible liquids in a glass or plastic container, with a capacity greater than those listed in subsection 6.2, is permitted only if the required liquid purity would be affected by storage in a metal container, or if the liquid would cause excessive corrosion of the metal container.

April, 2009 3 SOP-Chem-08 6.2 Properly stoppered or closed containers may be stored outside of a storage cabinet if they are of a capacity of 1 litre or less for flammable liquids and of a capacity of 5 litres or less for combustible liquids. However, it is preferable to store all flammable or combustible liquid, regardless of container type, in a storage cabinet when not in use. 6.3 Where individual containers with a capacity greater than those listed in subsection 6.2 are required for storage of flammable and combustible liquids in a building, safety containers conforming to the CSA-B376 Portable Containers for Gasoline and Other Petroleum Fuels or the ULC/ORD-C30 Safety Container guidelines, shall be used. Furthermore, these containers must not have a capacity greater than 25 litres. 6.4 All containers for flammable or combustible liquid shall be labeled in accordance with WHMIS regulations. Labelling must be with easily legible type, which contrasts any other printed matter on the container. 6.5 Up to 5 litres of flammable liquids may be stored in basement areas, provided it is stored in a safety container conforming to the guidelines listed in subsection 6.3. 6.6 The maximum volume of flammable and combustible liquid that can be stored outside of a cabinet in a room with no fire separation rating is 10 L, of which not more than 5 L can be flammable liquid. 6.7 The maximum volume of flammable and combustible liquid that can be stored outside a cabinet in a room having at least a minimum 45 minute fire separation is 250 L, of which not more than 60 L can be a Class II combustible liquid or 10 L of a flammable liquid. 6.8 In shops or industrial arts areas storage of up to 75 L of flammable and combustible material, of which not more than 25 L can be flammable liquids, shall be permitted outside of a cabinet. 6.9 Flammable and combustible liquids must be segregated by chemical group, where possible, in all storage areas. 6.10 Containers shall be stored such that they are not subject to excess heat, excess cold, or direct sunlight. 6.11 Storage volumes greater than those listed in subsections 6.6, 6.7 & 6.8 must be stored in an approved flammable liquid storage cabinet. The maximum storage in a single cabinet is 500 litres, of which not more than 250 litres can be flammable liquids. Only one cabinet is allowed per room.

April, 2009 4 SOP-Chem-08 6.12 Storage cabinets must conform to the ULC-C1275 Storage Cabinets for Flammable Liquid Containers, ULI 1275 Flammable Liquids Storage Cabinets, Factory Mutual Research or the NFPA 30 guidelines. 6.13 Storage cabinets shall not be located in or adjacent to exits, elevators or principle routes that provide access to exits. 6.14 All flammable liquid storage cabinets must be labeled with conspicuous lettering to indicate the cabinet contains flammable liquids and open flames must be kept away. 6.15 The Department of Environmental Health & Safety must approve any room being used for storage of flammable and/or combustible liquids in volumes greater than those listed in these procedures. Flammable and combustible liquid storage rooms must meet stringent requirements outlined in the Ontario Fire and Building Codes. 6.16 For the requirements regarding the storage of flammable and combustible materials in storage tanks, contact the Department of Environmental Health & Safety. 6.17 Approved and Labelled laboratory-safe refrigerators shall be used to store suitably contained flammable and combustible liquids below room temperature. These refrigerators have all the electrical contacts removed from the storage compartments thereby eliminating the risk of spark and possible ignition of the liquids. 7.0 Spills THE USE OF STANDARD, DOMESTIC REFRIGERATORS, REFRIGERATION UNITS, AND/OR FREEZERS FOR STORING ANY FLAMMABLE AND/OR COMBUSTIBLE MATERIAL IS PROHIBITED. NOTE: The maximum allowable concentration for storage in a domestic refrigerator is 20% flammable or combustible in an aqueous solution. NO EXCEPTIONS!!! 7.1 A spill control procedure shall be developed, approved and implemented for any location where flammable and/or combustible liquids are stored, handled, processed or used. The procedure must be based on and compatible with the Queen s University Spill Response Procedures (SOP-HAZMAT-03) issued by the Department of Environmental, Health and Safety. 7.2 Spill control procedures shall be prominently posted and maintained where flammable and/or combustible material is stored, handled, processed or used.

April, 2009 5 SOP-Chem-08 7.3 Adequate spill control material shall be available and located in close proximity to areas where flammable and/or combustible liquid is stored, handled, processed or used. This is in accordance to the Queen s University Spill Response Procedures. 8.0 Disposal of Waste Flammable and Combustible Liquids 8.1 To ensure compliance with all applicable government regulations, flammable and combustible material must be disposed of in accordance with the Hazardous Waste Disposal Procedures (SOP-Chem-01) issued by the Department of Environmental Health and Safety. Failure to do so will result in the material being rejected during pick-ups. 8.2 Waste flammable and combustible liquids awaiting disposal must be stored in an Approved disposal container with a maximum capacity of 20 litres, or in accordance with section 6.3. The container must be clean and in good condition. The flame arrester must be secured in place and free of debris. Labelling of the disposal container must comply with subsection 6.4. In addition, name, department and room number the can is to be returned to must be clearly displayed. 8.3 Waste liquid is classified as flammable and quantities fall under amounts specified in section 6.0. 8.4 Waste oil awaiting disposal should be stored in 20 litre (5 gallon) UN approved oil drums or pails. Revision History July 2005-Revision 1.0 Initial Release April 2009-Revision 2.0 Section 8.0 Revised