Alignment Laser System.



Similar documents
Machine Tool Inspection & Analyzer solutions

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

E420 SHAFT ALIGNMENT. Entry level measurement and alignment system for rotating machines BUILT-IN WIRELESS UNITS LARGE COLOUR DISPLAY QUICK START

Laser Alignment Using the CSI 2140

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

NGSS Data Consolidator (DC)

How To Use A Ds340 (Dsp)

Encoders for Linear Motors in the Electronics Industry

Mini InfraRed Thermometer with Laser Pointer

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Multi-Range Programmable DC Power Supplies 9115 Series

Tube Control Measurement, Sorting Modular System for Glass Tube

EMR-9 Quick Start Guide (00175)D 1

Innovative measurement technology for real professionals.

Product Information Sheet UH28CS-12kV Hi Pot Tester

How To Use A Detector 2

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

SHAFT ALIGNMENT. Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE MEASUREMENT VALUE FILTER COMPENSATION THERMAL GROWTH

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

EFC Frequency converters

Dupline Carpark Guidance System

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

High Performance Visible Laser Diode Scanners

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

ZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture

ROTALIGN Ultra is The intelligent System for Machinery Alignment

ROTATING MACHINES. Alignment & Positioning of. Fast, easy and accurate alignment of rotating machines, pumps, drives, foundations, etc.

Dual Laser InfraRed (IR) Thermometer with Color Alert

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

OCSM Series. High Resolution Digital Crane Scale. User Guide

Research-Grade Research-Grade. Capture

Series 6000 Torque measured metal bellow coupling

How To Use A Power Supply On A Powerline 2.2 (Ai)

digital quality control fail pass at your fingertips Smart Metrology Solutions.

Digital Magnetometer Systems - DM Series

Poor quality welds Machine downtime High maintenance costs Lost revenue

Automated part positioning with the laser tracker

Melting Point Apparatus

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

OPERATION MANUAL INFRARED THERMOMETER

Application Report: Running µshape TM on a VF-20 Interferometer

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Types of 3D Scanners and 3D Scanning Technologies.

PreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS

How To Use Bodescan For 3D Imaging Of The Human Body

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

// SUPER technology for precise web viewing: SUPER HANDYScan Be inspired. Move forward.

Multi-Range Programmable DC Power Supplies 9115 Series

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

High Power Fiber Laser Technology

ILX Lightwave Corporation

Fixturlaser XA. EXPRESS ALIGNMENT by Fixturlaser

Multifunction HVAC and IAQ Meter

Collision Prevention and Area Monitoring with the LMS Laser Measurement System

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Key Features. Product Overview. Threaded Joint Rate Simulator

Curing Lights HALOGEN CURING LIGHTS 5.2 L.E.D. CURING LIGHTS 5.3 LIGHT GUIDES 5.5 RADIOMETERS 5.6 ACCESSORIES FOR CURING LIGHTS 5.

MODEL 1211 CURRENT PREAMPLEFIER

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

LMS Test.Xpress Powering personal productivity

GT Sensors Precision Gear Tooth and Encoder Sensors

DIVERSITRONICS, INC. TM

ENAiKOON ultrasonic fuel-level sensor

Adaptability to Enhanced Security

Self-leveling Rotary Laser. Operating Manual. surface. Emitting direction of rotary laser-beam illustrated as follows:

QUICK START 40 MIN. ROTATION ENTERING SHAFT ALIGNMENT. Professional measurement and alignment system for rotating machines

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

siemens.com/mobility Radar detectors of the Heimdall family High detection rate, easy installation

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

RIEGL VQ-480. Airborne Laser Scanning. Airborne Laser Scanner with Online Waveform Processing. visit our website

PORTABLE FLOW METER KITS TDS-100H

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

STEALTH SERIES SHAFT ALIGNMENT SYSTEMS S B T W I R E L E S S 5 -A X I S

BLOOD COLLECTION MIXER

Adaptability to Enhanced Security

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

PHD User Manual. Table of Contents

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Agilent FieldFox RF Vector Network Analyzer N9923A Quick Reference Guide

STERILIZERS, LABORATORY DRYING OVENS

A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

Hygro-Thermometer + InfraRed Thermometer Model RH101

Intelligent Mould Flow Monitoring

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

FT-1000/GPS-N. System of remote monitoring and control of physical

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

Fire detection equipment

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Agilent E6020B FTTx OTDR

Wahl C50 Calibrator FEATURES

GSM HOME SECURITY SYSTEM

TENSIONMETER ** code 183_LNRSTW **

Dual Laser InfraRed (IR) Thermometer

1.44 kw Programmable DC Power Supplies XLN Series

Transcription:

- O T 6 0 0 0 Alignment Laser System.

The OT-6000. Multi -Target,Two Dimensional Alignment. Introducing the most powerful way to measure alignment at distances up to 300 feet. The OT-6000 Alignment Laser System provides simultaneous, real-time measurement of multiple targets along a single reference laser line. Now you can dynamically monitor work as it progresses. The OT-6000 displays the X-Y deviation of each measurement target via your computer or optional handheld data terminal. Utilized by several major aircraft manufacturers, shipbuilders, and the automotive industry, the OT-6000 Alignment Laser System has proven to streamline efficiency and reduce man hours in a wide range of alignment applications. A typical system consists of a single Model OT-6000 LL Alignment Laser, OT-6000 DIM Digital Interface Module, one or more OT-6010 Transparent Targets, and an OT-6020 Reference Target. Numerous options are available as well. Multiple Target Capability. Specify as few or as many transparent targets required for the job. The OT-6000 System accommodates up to six. All targets daisy-chain together, and each target readily fits into NAS conventional tooling spheres. Simply place the target in the beam path, and you re ready to go. Computer Control. Beam-Trak 6000 software makes it easy to dynamically monitor work in progress. This rich graphical interface displays the X-Y deviation of all targets simultaneously. One glance at the screen, and you know exactly the measurement profile of your project. Oversize fonts enable easy readability over great distances. 1 Silicon Position Sensing Detector. 9 0.001-Inch Resolution At 300 Feet. Optimize precision and add a greater measure of confidence. The OT- 6000 provides 0.001-inch resolution at distances up to 300 feet. This is enabled by a third generation fiber-coupled diode laser delivery system that ensures exceptional beam coherence over long distances even in demanding outdoor environments. An Ideal Laser Tracking Alternative. Many consider expensive, laser trackers too much solution for alignment applications alone. The OT-6000 provides a simpler, far more cost-effective alternative with zero compromise to accuracy. Moreover, with its multiple target, real-time measurement capability, the OT-6000 provides major benefits laser trackers don t. 1. Applications Software 2. Reference Target 3. Transparent Target 4. Calibration Wedge 5. Reflector Plate 6. Laser 7. Digital Interface Module 8. Remote Display 9. Remote Data Terminal 2 3 8 7 4 5 6

Laser Alignment At A Glance. The system cables together in moments using a simple daisy-chain configuration. How Laser Alignment Works. The principle of linear laser alignment is simple. A stationary laser, aimed at a reference target up to 300 feet away, creates a line in space that serves as a rock-solid measurement reference. Next, any number of transparent targets are placed directly in the beam path. As the laser light passes through each transparent target, the target is able to determine its X-Y deviation relative to the laser beam. The position data from each target is fed into a handheld data terminal, digital display unit, or windows based application software program. Real-Time Feedback. Enables user to make on-the-spot alignment adjustments. Faster Measurement. Reduces man hours and facilitates project efficiency. Maximum Range. Perform measurements at distances up to 300 feet. Simultaneous Measurement. Enables simultaneous measurement from multiple targets. Data Analysis. Position data can be monitored, stored and analyzed by a computer. The Line Laser Advantage. Laser based alignment provides significant advantages over competing alignment techniques. Cost Effective. Outperforms laser tracking systems in this specific application, at a fraction of the price. Ultra Precise. Eliminates margin of error associated with subjective manual approaches. The OT-6000 Alignment Laser System simultaneously measures X and Y position along several struts used to hold the propellor shaft on the USS Ronald Reagan aircraft carrier.

OT-6000 LL ULTRALIGN LASER OT-6010/6020 OT-6000 DIM TARGET SERIES AND DIGITAL INTERFACE MODULE INTERNAL FIBER-COUPLED LASER DIODE. No-compromise performance to 300 feet. Beam centration of + 0.002 inches. Pulsed at 500 Hz allows target to be totally unaffected by ambient light. POWER. An internal rechargeable NiMH battery pack provides 24 hours continuous use. AC power also. LOW POWER INDICATOR. Illuminates when battery pack is low. TAPERED NAS MOUNT. Made from chrome-plated stainless steel, the NAS Mount is slightly tapered near the front of the laser for easy insertion into NAS tooling sphere mounts. OT-6000 CW 0.010-Inch Calibration Wedge (option). Allows for convenient field verification of laser/target calibration. Conveniently attaches directly to OT-6000 Series Target. OT-6000 RP Reflector Plate (option). Assists in initial setup of targets by showing position of reflected beam from target face. The OT-6000 Target Series consists of two target types: the OT-6010 Transparent Target and the OT-6020 Reference Target. The OT-6000 DIM provides power to the targets in a daisy-chain configuration and serves as a RS-232/RS-485 communications hub for all targets. This enables remote computer control of the entire system. MULTI-TARGET CAPABILITY. Utilize up to six OT-6010 targets and one OT-6020 target per application. 1-INCH DIAMETER SENSOR AREA. Makes it easy to place target into reference beam path. PROPRIETARY TRANSPARENT DESIGN.* A proprietary beam-splitting pellicle design with internal compensation wedges eliminates beam deviation associated with laser beams passing through glass. LEVELING BUBBLE. A 30 minute level bubble allows for precise positioning of the target. POSITIVE MAGNETIC MOUNTING. Integral magnets within the OT-6000 Series Target firmly secure the target when inserted into a standard NAS tooling sphere. INTELLIGENT SENSOR DESIGN. When mounted in a standard NAS tooling sphere, the target's internal PSD is perfectly centered within the sphere to ensure repeatability and insensitivity to errors in angular measurement. OT-6000 RD Remote Display (option). Displays X-Y deviation at location of target. Installs instantly with magnetic mount. * OT-6010 only.

OT-6000 BEAM-TRAK 6000 SOFTWARE (OPTION) SIMULTANEOUSLY VIEW ALL TARGETS. View X-Y deviation of all targets simultaneously, in real-time. CUSTOMIZE PARAMETERS. Select measurement units, set resolution, toggle zero offset, and customize display with desired fonts and font sizes. Save settings for instant recall. COMMUNICATE WITH TARGETS. Assign and change target address, and set the internal target address. Save settings for instant recall. INTUITIVE OPERATION. Minimal, straightforward controls ensure simple operation and a fast learning curve. The OT-6000 AL Auto-Align Laser System is a variation of the standard OT-6000 LL Ultralign Laser. It is specifically designed for applications where excessive stress during the alignment process of a large structure can cause the alignment laser and reference target to move out of center. The OT-6000 AL utilizes an automatic feedback loop that constantly monitors alignment between the alignment laser and reference target. Should the center alignment on the reference target be disturbed, internal motion controllers within the laser head automatically realign the laser to the reference target's center. Auto-Align Laser System: OT-6000 AL Internal motion controllers automatically realign laser to the reference target center. User-programmable settings for out-of-tolerance condition and feedback sampling rate. Tolerance and sampling settings can be stored into memory. OT-6000 RDT REMOTE DATA TERMINAL (OPTION) REMOTE OPERATION. Communicate with the entire system at distances up to 100 feet. CONTROL FUNCTIONS. Select pulse averaging and zero offset at the push of a button. DISPLAY DATA. View individual target positions and system status on the 4-line by 20-character supertwist backlit display. For complete information on the OT-6000 AL system, please contact On-Trak today.

Since 1992, On-Trak Photonics, Inc. has provided advanced position sensing and alignment solutions to companies ranging from Fortune 500 corporations to small industry start-ups. We pride ourselves not only on superior product, but exemplary service and support that goes the extra mile. Before, during, and after the sale. Please contact us today for more information on the OT-6000 Alignment Laser System, and for details on our complete line of solutions for laser-based alignment. OT-6000 System Specifications OT-6000LL Ultralign Laser Power Output Wavelength Beam Diameter Class IIA (<1 mw visible red) 635 nm 8 to 12 mm Beam Profile Circular gaussian, TEM 00 Modulation Frequency 500Hz Operating Distance 0 to 300 feet (100 m) Centering Controls NiMH Battery Lifetime Power Requirement Weight Overall Length Enclosure + 0.002 inches (0.05 mm) On/off switch 24 hours continuous operation 12V/500mA DC wall charger 8 lbs. (3.64 kg.) 14.5 inches (368.3 mm) NAS standard 2.2498 inches (57.15 mm) diameter OT-6020 Reference Laser Alignment Target Position Sensing Area Resolution Centering Weight Size Laser Acquisition Indicator On Indicator 1.00 inch diameter (25.4 mm) 0.001 inches (0.01 mm) + 0.002 inches (0.05 mm) to NAS mount 3.5 lbs. (1.6 kg.) NAS mount: 2.2498 x 3.50 inches (57.15 x 88.90 mm) Housing: 3.0 x 3.0 x 3.25 inches (76 x 76 x 82 mm) Red LED flashes simultaneously with laser pulse Green LED indicates power on/off OT-6010 Transparent Laser Alignment Target OT-6000 RD Remote Display Target Transmission > 85% Display Resolution Weight 0.8 inches high red LED.0000, 0.000, 00.00 inches 21 oz. Dimensions 4.0 x 5.2 x 1.2 inches (H x W x D) Note: OT-6010 specifications are identical to OT-6020 specifications (above), plus the following: Max Number of Targets in Line 6 OT-6010 Transparent targets 1 OT-6020 Reference target