MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Similar documents
for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Oasis HLB Cartridges and 96-Well Plates

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Purification of reaction mixtures using flash chromatography.

How To Test For Contamination In Large Volume Water

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Sample Preparation Using Solid Phase Extraction

Innovative vs Traditional

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Sorbents. [ A] [ A] aq. Strong affinity = large K D. Digital chromatography: all-or. or-nothing LC mechanism to extremes K =

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

LC Application Note.

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

A Novel Approach to Low Volume Sample Preparation

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

Solid Phase Extraction for Water Analysis. presented by

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Gas Chromatography Liner Selection Guide

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

An Automated Method for the Selective Solid Phase Extraction of Zearalenone from Wheat Using Molecularly Imprinted Polymers

A Complete Solution for Method Linearity in HPLC and UHPLC

Optimization of SPE for Analysis of Mandelic Acid as a Biomarker of Exposure to Ethyl Benzene

GC-xt. The most flexible GC /GC-MS liquid sample injector

Enhancing Utility and Throughput of SPME using Advanced Automation Strategies

Opiates in Urine by SAMHSA GC/MS

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

Filter Vials. Product Knowledge. PTFE PVDF Nylon PES. Pat. US #7,790,117 Worldwide patents pending. Thomson Instrument Company Toll Free

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Overview. Purpose. Methods. Results

ORGANIC SAMPLE PREPARATION

Determination of Caffeine in Beverages HPLC-1

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

METHOD 8310 POLYNUCLEAR AROMATIC HYDROCARBONS

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Chemical analysis service, Turner s Green Technology Group

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

Amino Acid Analyzer L-8900

SPE Reference Manual & Users Guide. Reference Manual & Users Guide

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

6. ANALYTICAL METHODS

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

RapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers

Basics of SPE Technology & Mechanisms. Pieter Grobler, Sigma-Aldrich RSA

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

PrepTip. Reverse Phase PrepTip User Guide

PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation

Benzo[a]pyrene Method Development

Background Information

Transcription:

- Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples from hours to minutes Eliminate all extra steps between sample preparation and sample injection Reduce buffer and solvent volume from milliliters to microliters Reduce the sample volume needed to as little as 10 µl PATENT PENDING 5 years 1 9 6 0-2 0 1 0 AUSTRALIA & PACIFIC REGION CHINA EUROPE INDIA JAPAN MIDDLE EAST USA

What is? is Micro Extraction by Packed Sorbent and is a new development in the fields of sample preparation and sample handling. is the miniaturization of conventional SPE packed bed devices from milliliter bed volumes to microliter volumes. The approach to sample preparation is suitable for reversed phases, normal phases, mixed mode or ion exchange chemistries. is available in a variety of common SPE phases. The Barrel Insert and Needle Assembly (BIN), (Patent Pending) contains the stationary phase, and is built into the syringe needle (Figure 1). FIGURE 1 Schematic of the BIN in the syringe needle. Why use? Historically, many sample preparation methods used liquid-liquid extraction (LLE) which required large volumes of sample, solvents and time. The advantages of SPE over LLE are that SPE takes much less time, can be developed into a fully automated technique, requires much less solvent and offers selectivity. performs the same functions as SPE the removal of interfering matrix components and the selective isolation and concentration of analytes. increases the advantages of conventional SPE in the following ways: Significantly reduces the time needed to prepare and inject samples. Can be combined with LC or GC automation - the extraction step and injection step are performed on-line using the same syringe. Significantly reduces the volume of solvents needed. Ability to work with samples as small as 10 µl versus several hundred µl for SPE. Sample Size and Sensitivity Sample volumes may be as little as 10 µl, or by taking multiple aliquots of 100 µl or 250 µl, samples of 1 ml or larger may be concentrated. Automation The capability to extract samples and make injections on-line using a single device reduces both sample processing times and the need for operator intervention. Sorbent Life Typical BIN life for extraction of whole plasma sample is conservatively about 40 to 100 samples. This significantly increases for cleaner samples. Carry Over The small quantity of phase in the BIN can be easily and effectively washed between samples to reduce the possibility of carryover. This washing process is simply not practical with off-line SPE devices. With automation of washing can occur while the previous sample is running. Flexible and Easy to Use The dimensions of the sorbent bed ensure that the performance remains identical to conventional SPE devices when used for extraction of similar samples. BINS can be used for sample volumes as small as 3.6 µl making them particularly well suited to on-line use with LC-MS analysis of volume limited samples.

How to use Step 1: Pump the sample through the BIN (one or more volumes may be taken). STEP 1 STEP 2 STEP 3 STEP 4 Step 2: Wash the BIN once by pumping 20 µl to 50 µl of wash solution through the BIN to remove interferences. Step 3: Elute the analyte by drawing solvent through the BIN into the syringe barrel. Step 4: Inject the analyte directly into the injector. Pump 50 µl solvent followed by 50 µl wash solution to prepare BIN for the next sample. SAMPLING (1-N TIMES) WASHING ELUTION SOLVENT INJECTION FIGURE 2 When the sorbent is exhausted, or another phase is required, the BIN is easily exchanged by simply unscrewing the locking nut and removing / replacing the BIN. The BIN is easily installed into the syringe housing and then secured by the locking nut. Individual labeling of each BIN insures the use of the correct stationary phase for each extraction. : MICRO EXTRACTION BY PACKED SORBENT

How Does Perform? Sample preparation for complex biological samples is readily adapted to and reduces the volumes of sample and reagents required for extraction when compared with conventional SPE and other micro extraction procedures. The extraction of xanthine metabolites from raw human urine using a BIN packed with C18, prior to GC-MS analysis, is shown in Figure 3 and the extraction of anesthetics from rat plasma using a BIN packed with C2, prior to LC-MS analysis is shown in Figure 4. ABUNDANCE EXTRACTION FROM RAW URINE THEOPHYLLINE / PARAXANTHINE RETENTION TIME (MINUTES) THEOBROMINE CAFFEINE FIGURE 3 Difficult matrices such as human urine are easily processed using. In this example 100 µl of human urine was aspirated through a C18 BIN (conditioned with methanol and water, water wash). Bound xanthines were eluted with 30 µl methanol, 2 µl injected on a BPX5 column for GC-MS analysis. LIDOCAINE (2.4 µmol/l) EXTRACTION FROM PLASMA ROPIVACAINE (2.5 µmol/l) 2.18 3.29 BUPIVACAINE (3 µmol/l) 5.17 FIGURE 4 Local anesthetics were spiked into rat plasma samples - final concentrations: Lidocaine 2.4 µmol/l, Ropivacaine 2.5 µmol/l and Bupivacaine 3.0 µmol/l. 50 µl of the spiked plasma was aspirated through a C2 BIN, washed with water and eluted using 0.1% HCOOH in 25% Acetonitrile + 75% water onto a C18, 100 X 2.1 mm column. 1 2 3 4 5 6 7 8 9 10 RETENTION TIME (MINUTES)

How Does compare? Accuracy and Precision Table 1 summarizes the precision and accuracy results obtained analyzing Ropivacaine by four sample preparation methods:, Liquid-Liquid Extraction (LLE), conventional SPE and Solid Phase Microextraction (SPME). Compared to SPME, also a µspe technique, demonstrated better precision and accuracy while taking significantly less time to process each sample. Table 2 compares the accuracy, precision, limits of detection and extraction time of with two other µspe techniques, SPME and SBSE (Stirring Bar Sorbent Extraction) for 5 different PAH s extracted from water. The results from the and SBSE techniques are significantly better than SPME but processes each sample 100 times faster than SBSE. TABLE 1 : Comparison of accuracy and precision between and other methods for ropivacaine (local anesthetics) Method Ropivacaine Accuracy Precision (RSD%) Handling time LOD (nm) (%) (Inter-assay) [1] / GC-MS 2 105 5.0 1 min [2] LLE / GC-MS 2 101 3.8 20 min [3] SPE / LC-UV 100 101 3.0 20 min [4] SPME / GC-MS 5 110 6.3 40 min M. Abdel-Rehim / J. of Chromatography B, 801 (2004) 317-321 TABLE 2 : Comparison of accuracy and precision of, SPME and SBSE for the analysis of PAH s in water. Compound Accuracy Precision RSD Limit of detection Extraction time (%) (%) (ng/l) (min) SPME SBSE SPME SBSE SPME SBSE SPME SBSE Anthracene 84 81 99 12 3 6 5 100 1.2 2 30 200 Chrysene 107 81 100 1 4 5 5 90 0.2 2 30 200 Fluoranthene 100 84 100 9 4 4 5 100 1.2 2 30 200 Fluorene 103 96 97 5 5 4 1 40 0.7 2 30 200 Pyrene 115 86 100 7 3 3 1 40 0.7 2 30 200 M. Abdel-Rehim / J. Chromatog. A 1114 (2006) 234-238 : MICRO EXTRACTION BY PACKED SORBENT

Is there significant carry over using? Devices used for SPE are traditionally considered to be single use. The precision engineering used in the design and manufacture of allows for simple wash steps and consequently the re-use of the device. To demonstrate this we extracted phenols from waste water and measured the carry over between experiments. TIC 220000 2.4-dichlorophenol 2.4-dimethyphenol 2-chlorophenol phenol 4-chloro-3-methylphenol 2.4.6-trichlorophenol 3 5 7 9 11 13 RETENTION TIME (MINUTES) Phenols 25ppb Extraction 2 Extraction 3 Figure 5 shows the chromatograms for the three 10 µl extractions. The first is labeled phenols 25 ppb, the second is extraction 2, and the third extraction 3. Clearly all of the phenols were eluted in the first 10 µl of Methanol used. One of the most often stated reasons for the use of disposable SPE BINS is the issue of carry over. Results from 5 studies are summarized in Table 3. Utilizing a series of washes using eluent and then wash solution the carry over was virtually eliminated. With a cycle time measured in seconds for this washing takes less than 5 minutes. To accomplish the same for conventional SPE takes an hour or more and uses significant amounts of solvents. Summary Table 4 summarizes the comparison of, SPME and conventional SPE. requires much less time than either SPE or SPME, and shows much better recovery and sensitivity than SPME. also eliminates any intermediate steps between the sample preparation steps and the injection into a GC or LC system. FIGURE 5 Phenols at 25 ppb in alkane contaminated water. 10 x 100 µl cycles on C18 BIN (conditioned with methanol and water). Sample was eluted with methanol 10 µl, 2 µl injected onto a BPX5 column and analyzed by GC-MS. TABLE 3 : Comparison of carryover and wash regime. Wash volume (ul) # of washes and Carry-over Source wash solution PAH s in water 50 µl 4X methanol, 5X water 0.2% - 1% M. Abdel-Rehim / J. Chromatog. A 1114 (2006) 234-238 Anesthetics in 50 µl 4X methanol, 4X water ~ 0.2% (I.S.) M. Abdel-Rehim / J. Human Serum of Chromatography B, 801 (2004) 317-321 Roscovitine in 50 µl 5X methanol/water (95:5, v/v), <0.1% M. Abdel-Rehim / J. plasma and urine 5X water/methanol (90:10, v/v) of Chromatography B, 817 (2005) 303-307\ Roscovitine in 50 µl 4X methanol, 4X water <0.01% M. Abdel-Rehim / J. Human plasma Mass Spectrom. 204;39:1488-1493 Olomoucine in 50 µl 5X methanol/water (95:5, v/v), <0.1% M. Abdel-Rehim et al. / Human plasma 5X water/methanol (90:10, v/v) Analytica Chimica Acta 2005 TABLE 4 : Comparison of BINs, SPME and conventional SPE. Factor BIN SPE SPME Amount sorbent 0.5-2 mg 50-2000 mg thickness 150 mm Sample prep. time 1-2 min 10-15 min 10-40 min BIN use 40 to 100 extractions once 50-70 extractions Recoveries good good low Sensitivity good good low M. Abdel-Rehim / J. of Chromatography B, 801 (2004) 317-321

SYRINGE OPTIONS All syringes may be used manually as well as with the listed autosamplers Part No. Description Items per package 005291 100 µl Removable needle syringe for CTC Analytics, HTA 300A Plus & Varian 8400 systems 1 031826 Replacement plunger assembly for 005291 1 006291 250 µl Removable needle syringe for CTC Analytics, HTA 300A Plus & Varian 8400 systems 1 031831 Replacement plunger assembly for 006291 1 006292 250 µl Removable needle syringe for CTC Analytics systems 1 031831 Replacement plunger assembly for 006292 1 BARREL INSERT AND NEEDLE ASSEMBLY OPTIONS For GC applications, needle is 23 gauge, 0.63mm OD, Cone point style Phase Description For use with # per Part Syringe, P/N Pack Number C18 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900101 Silica BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900102 C8+SCX* BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900103 C2 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900104 C8 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900106 Development kit for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900105 (contains 1 each of C18, C8, C2, SILICA and C8+SCX) C18 BIN for CTC Analytics systems using 250 µl syringes 006292 5 2900301 Silica BIN for CTC Analytics systems using 250 µl syringes 006292 5 2900302 C8+SCX* BIN for CTC Analytics systems using 250 µl syringes 006292 5 2900303 C2 BIN for CTC Analytics systems using 250 µl syringes 006292 5 2900304 C8 BIN for CTC Analytics systems using 250 µl syringes 006292 5 2900306 Development kit for CTC Analytics systems using 250 µl syringes 006292 5 2900305 (contains 1 each of C18, C8, C2, SILICA and C8+SCX) For LC Applications, needle is 22 gauge, 0.72mm OD C18 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900401 Silica BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900402 C8+SCX* BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900403 C2 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900404 C8 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900406 SCX BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900408 SAX BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900409 Development kit for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900405 (contains 1 each of C18, C8, C2, SILICA and C8+SCX) C18 BIN for CTC Analytics systems using 250 µl syringe 006292 5 2900501 Silica BIN for CTC Analytics systems using 250 µl syringe 006292 5 2900502 C8+SCX* BIN for CTC Analytics systems using 250 µl syringe 006292 5 2900503 C2 BIN for CTC Analytics systems using 250 µl syringe 006292 5 2900504 C8 BIN for and CTC Analytics systems 006292 5 2900506 SCX BIN for and CTC Analytics systems 006292 5 2900508 SAX BIN for and CTC Analytics systems 006292 5 2900509 Development kit for CTC Analytics systems using 250 µl syringes 006292 5 2900505 (contains 1 each of C18, C8, C2, SILICA and C8+SCX) Base material is silica with mean particle size of 45 µm and pore size of 60Å. *C8+SCX BINS are labelled as M1. : MICRO EXTRACTION BY PACKED SORBENT

Comparison Table SPE versus SPE Sample Volume 3 ml 50 µl Time Price Solvents Evaporation Step 10 ml 500 µl Yes Unnecessary BR-0238-M RevK SGE Analytical Science 07/2010 www.sge.com