Pressure monitoring equipment for oil-sf 6. bushings, type GOEK



Similar documents
1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

Safety Manual BT50(T) Safety relay / Expansion relay

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

ALARMLINE ANALOGUE Linear Heat Detection System

Cable Plug acc. to DIN EN , Form A

Transformer Bushings for GIS

Unified requirements for systems with voltages above 1 kv up to 15 kv

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Series 8146/5-V37 and Series 8150/5-V37

Inductive sensor NI10-M18-Y1X-H1141

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Gas insulated wall bushing, type GGFL

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

OLI. Oil level indicator

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

a Nexans company Catalogue 2014

Technical Data. Dimensions

ACS-30-EU-EMDR-10-MOD

WE-350 Series ¼ Turn Electric Actuator

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Mounting Instructions. Torque Transducer. A en

6000 Series Buccaneer

3/2-way Solenoid Valve, direct-acting, NC or NO

Standard Buccaneer - Ethernet

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Voltage Regulator SPAU 341 C. Product Guide

HERZ-Thermal Actuators

Plastic tube flowmeters Series PT/PS

Linear Luminaire with LED Series EXLUX 6402/2

Trip circuit supervision relay. Type RXTCS

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Terminal Boxes Series 8146

FAQs-Main switchboard design criteria

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Digital inductive conductivity transmitter

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

The Intelligent AX1 Switchgear for Medium Voltage

CompactLogix Power Supplies Specifications

SITRANS F flowmeters SITRANS F M

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

System 8. ü ( System 8

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

a Nexans company Catalogue 2013

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Three-phase monitoring relay CM-PFE

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

ST Series POWER SUPPLIES USER INSTRUCTIONS

Adjustment functions for both span and shift have been incorporated

Drayton Digistat +2RF/+3RF

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Floodlight Range Installation Guide

Elektromotoren und Gerätebau Barleben GmbH

Power supply unit Model: PAC-SC50KUA

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Urban lighting luminaire XMOD RX. Registered models - Design Massimo Sacconi. NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Elektromotoren und Gerätebau Barleben GmbH

Toroidal Conductivity Sensor

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Remote Monitoring and REC 501 Control Unit Product Guide

Safe and secure distribution of medium voltage with AX1

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

SURGE PROTECTIVE DEVICES

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Technical Data. Dimensions

Thermistor motor protection

IEC Connectors. Introduction

Catalog. Arc Guard System TM TVOC-2

ACTIV-8 PLUS Insulated Conductor Bar

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

TECHNICAL SPECIFICATIONS

Compact pressure switch Flameproof enclosure Ex d Model PCA

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

MasterINTERFACE 39 Series - Relay interface modules

Bulletin 150 SMC Flex Smart Motor Controller Specifications

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

MasterINTERFACE 39 Series - Relay interface modules

Inductive sensors. Compact, fast, reliable. Edition 2013

Transcription:

Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30

This document must not be copied without our written permission, and the contents thereof must not be imparted to a third party nor be used for any unauthorized purpose. Contravention will be prosecuted.

Safety information Keep this instruction available to those responsible for the installation, maintenance, and operation of the bushing. The installation, operation, and maintenance of a bushing present numerous potential unsafe conditions, including, but not limited to, the following: High pressures Lethal voltages Moving machinery Heavy components Slip, stumble or fall Specialized procedures and instructions are required and must be adhered to when working on such apparatus. Failure to follow the instructions could result in severe personal injury, death, and/or product or property damage. Additionally, all applicable safety procedures such as regional or local safety rules and regulations, safe working practices, and good judgement must be used by the personnel when installing, operating, maintaining and/or disposing such equipment. Safety, as defined in this instruction, involves two conditions: 1. Personal injury or death. 2. Product or property damage (includes damage to the bushing or other property, and reduced bushing life). Safety notations are intended to alert personnel of possible personal injury, death or property damage. They have been inserted in the instructional text prior to the step in which the condition is cited. The safety conditions are headed by one of the three hazard intensity levels which are defined as follows: DANGER Immediate hazard which will result in severe personal injury, death, or property damage. WARNING Hazard or unsafe practice which could result in severe personal injury, death, or property damage. CAUTION: Hazard or unsafe practice which could result in minor personal injury, or property damage.

Contents 1 Design 5 1.1 Pressure monitor 5 1.1.1 Fuse diagram 5 2 Technical data 7 2.1 Pressure monitor 7 2.2 Pressure sensor 8 3 Mounting of pressure sensor 9 4 Cable connections 10 4.1 Cable between pressure sensor and pressure monitor 10 4.2 Cable from pressure relays and cable for supply voltage 11 4.3 Cable gland 11 4.4 Circuit diagram 12 5 Ordering particulars 13 4 5693 827-6 en, Rev. 3

1 Design 1 Design The oil pressure in bushings for SF 6 switchgear installation can be supervised by a pressure monitor according to Fig. 3 and a pressure sensor according to Fig. 4. The sensor is normally mounted in our factory on a valve on the bushing flange according to Fig. 5. A cable connects the sensor with the monitor, which is mounted at comfortable eye-level. 1.1 Pressure monitor The pressure monitor is furnished with three pressure relays. The first relay shall give alarm at too low pressure and is pre-set at 85 kpa (abs). The second relay shall give alarm at too high pressure and is pre-set at 250 kpa (abs). The third relay is used for tripping the transformer breaker and is pre-set at 350 kpa (abs). The second and the third relay are pre-set well above the maximum service pressure in the bushings and below the minimum service pressure in the SF 6 system. The pressure relays must be set in the factory. If the supply voltage disappears, no alarm will be released. The pressure monitor is furnished with a display for pressure indication and three lamps indicating status of the pressure relays. The lamp is lit when the alarm level is reached. Principal operation of the pressure monitor is shown in Fig. 2. 1.1.1 Fuse diagram Fig. 1. 5693 827-6 en, Rev. 3 5

1 Design Fig. 2. Block diagram. 6 5693 827-6 en, Rev. 3

2 Technical data 2 Technical data 2.1 Pressure monitor Measuring range: -100 kpa - +400 kpa Indication accuracy: 1 % Resolution: 1 kpa Alarm level 1: The relay is making at falling pressure Alarm level 2: The relay is making at rising pressure Alarm level 3: The relay is making at rising pressure Switch differential: 20 kpa Relay switching capacity: 5 A 250 V AC 0.4 A 110 V DC, L/R 40 ms Operating range: - 40 C - +70 C Display type: LED 14 mm high brightness 3½ digit Supply voltage: 115 / 230 V AC 15 %, 50-60 Hz Terminal instruction: Circuit diagram acc. to Fig. 7 Input: Pressure sensor with shielded cable Immunity tested to conducted electromagnetic interference. Impulse voltage tested and 1 MHz tested acc. to IEC 255-4. Mains frequency tested. Spark tested. Vibration tested. Casing: Die casted aluminium alloy with a two-pack urethane-based coating over a two-pack epoxy-urethane-based primer. Clear transparent window of tough polycarbonate plastic. Case is ventilated and weather proof acc. to DIN 40050 protective class IP 55. Fig. 3. Pressure monitor. 1. Four bolts for the cover 2. Vibration absorber 3. Cover 4. Cable entry for pressure sensor 5. Cable entry for pressure relays 6. Cable entry for supply voltage 7. Mounting clamp 5693 827-6 en, Rev. 3 7

2 Technical data 2.2 Pressure sensor Pressure range: -100 kpa - + 400 kpa Overpressure: 1 MPa Output: 0-10 V Accuracy: 2 % Operating range: - 40 C - +70 C Withstand: 120 C for 48 hours Type: Piezoresistive pressure sensor Immunity tested to conducted electromagnetic interference. Impulse voltage tested and 1 MHz tested acc. to IEC 255-4. Mains frequency tested. Spark tested. Vibration tested. Casing: Protective class IP 55 acc. to DIN or IEC. Weather proof for outdoor mounting. Wetted parts: Stainless steel AISI 316. Fig. 4. Pressure sensor. 8 5693 827-6 en, Rev. 3

3 Mounting of pressure sensor 3 Mounting of pressure sensor See Fig. 5. WARNING No work at all can be performed on the bushing while it is energized or not earthed. Alternative 1: The pressure sensor is mounted in our factory. - Check that the cable entry is directed downwards, when the bushing is mounted on the transformer. If not, close the valve. - Unscrew the nut (2) as much as the pressure sensor can be turned. - Turn the sensor in such a way that the cable entry is directed downwards. - Screw the nut (2) tight. - Open the valve. Alternative 2: The pressure sensor is not mounted in our factory. - Check that the valve is closed. If not, close the valve. - Dismount the cover and the gasket (O-ring) from the valve. (The gasket (O-ring) 29.2 x 3 is placed between the valve and the cover.) - Mount the pressure sensor and the gasket (O-ring) on the valve. Unscrew the nut (2) as much as the pressure sensor can be turned. - Turn the sensor in such a way that the cable entry is directed downwards, when the bushing is mounted on the transformer. - Screw the nut (2) tight. - Open the valve. The valve is closed The valve is open Fig. 5. Mounting of pressure sensor. 1. Valve 2. Nut 3. Pressure sensor 4. Bushing flange 5. Cover 6. Cable entry 5693 827-6 en, Rev. 3 9

4 Cable connections 4 Cable connections WARNING No work at all can be performed on the bushing while it is energized or not earthed. 4.1 Cable between pressure sensor and pressure monitor The cable shall be connected on the connection terminal board in the junction box on the pressure sensor and on the connection terminal board in the pressure monitor. The cover of the pressure monitor is dismounted by unscrewing the four bolts according to Fig. 3. The sheath of aluminium in the cable shall be connected to the enclosure of the pressure sensor and to the enclosure of the pressure monitor. The distance between the sheath of aluminium and the connection point on the enclosure shall be as short as possible. This connection shall normally be performed by squeezing the auxiliary bar conductor between the two tapered collars in the cable gland. Circuit diagram according to Fig. 7. Recommended type of cable: House wiring cable. ABB article no. 1684 0025-5. Number of conductors and nominal crossectional area: 4G2.5 mm 2. Outside diameter of cable: 11-13 mm. General: Operating temp: Max +70 o C Flammability class: Acc. to IEC 332-1 Electrical ratings: Rated voltage: Test voltage: 450/750 V 2.5 kv, 50 Hz, 15 min Material: Conductor: Untinned copper acc. to IEC 228 class 2 Insulation: PVC acc. to IEC 227-1 Filling: PVC Aux. bare conductor: Tinned copper acc. to IEC 228 Inner sheath: Aluminium Sheath: PVC acc. to IEC 227-1 10 5693 827-6 en, Rev. 3

4 Cable connections 4.2 Cable from pressure relays and cable for supply voltage The cables shall be connected on the connection terminal board in the pressure monitor. Recommended type of cable: Control cable. Number of conductors Outside ABB and nominal cross- diameter article no. sectional area Cable from pressure relays 7G2.5 mm 2 16.0-19.2 mm 1683 1927-4 Cable for supply voltage 4G2.5 mm 2 13.0-15.8 mm 16831927-2 General: Operating temp: Max +105 o C Flammability class: Acc. to IEC 332-1 Electrical ratings: Rated voltage: Test voltage: 600/1000 V 3 kv, 50 Hz, 5 min Material: Conductor: Stranded, tinned and annealed copper acc. to IEC 228 class 2 Insulation: Acc. to IEC 502, class PVC B Inner sheath: Acc. to IEC 502, class PVC B Armour: Galvanised steel wires in one layer Sheath: Acc. to IEC 502 class ST2 4.3 Cable gland Recommended cable glands: Outside diameter of cable Cable gland, ABB article no. 9-16 mm 2672 919-A 16-20 mm 2672 919-C Material: Basis metal: Surface treatment: Wrought brass Nickel plating Fig. 6. Cable gland. 5693 827-6 en, Rev. 3 11

4 Cable connections 4.4 Circuit diagram Fig. 7. 12 5693 827-6 en, Rev. 3

5 Ordering particulars 5 Ordering particulars When ordering please state: 1. Catalogue no. 2. Alarm levels required if these deviate from recommended standard values. 3. Special requirements. Identity number marked on: Supply voltage Catalogue no. Pressure monitor Pressure sensor 230 V AC LF 410 024-K AKM 47880-5 AKM 47881-1 115 V AC LF 410 024-L AKM 47880-6 AKM 47881-1 Cables and cable glands are not included in the catalogue numbers. 5693 827-6 en, Rev. 3 13

ABB Power Technology Products AB Components Visiting address: Lyviksvägen 10 Postal address: SE-771 80 Ludvika, SWEDEN Tel.+46 240 78 20 00 Fax +46 240 121 57 E-mail: sales@se.abb.com www.abb.com 5693 827-6 en, Rev. 3, 2002-01-30