GPD Rubber Press Seals



Similar documents
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Puddle Flange. FRANK Puddle Flange

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

EWE Ball Valve-Type Tapping Valve. EWE Ball-Type Tapping Valve. EWE GBM Tapping Valves. for water and gas

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

WATER SERVICE 2

Digital inductive conductivity transmitter

TECHNICAL SPECIFICATION

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

NEW CONNECTION INDUSTRIAL PRODUCTS NC.10V NC.20V NC.30V. NC. SD.10 NC. SD.20 NC. F.Clamp

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Terminal Boxes Series 8146

How To Use A Flowmeter

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

SECTION STORM DRAINAGE SYSTEM

Installation Instructions

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

INDEX. Sec. No. Items Page Nos.

Metal Pressfitting Pipe Systems

Installation Instructions For Slider Casement Air Conditioners

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Passive Fire Protection

Couplings. Drain Couplings Standard Couplings Large Diameter Couplings Adaptor Couplings Flexible Saddles Bushes

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

Saferand easierinstallation

TRANS-05, Torque Tube Removal, Rebuilding, and Installation

Linear Luminaire with LED Series EXLUX 6402/2

Hose and Tube Fittings Series 1-3

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

Quality & Innovation, Manufactured in the U.S.A.

Guide rail bracket (for adjustable heads)

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

DIVISION 4300 STORM DRAINAGE

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

GK Packing System Welding Instructions

Appendix A: Acceptable pipe and fitting materials

Toroidal Conductivity Sensor

James M. Pleasants Company

Syphonic Roof Drainage

BIS Gulv / Radiator Beslag

Plastic tube flowmeters Series PT/PS

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

TG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION

Wastewater Capital Projects Management Standard Construction Specification

Sliding and Folding Door Fittings Sliding Door Accessories

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

GISMA UNDERWATER CONNECTORS SERIES 40

Operating Instructions

ROOF DRAINS TABLE OF CONTENTS

FLEXWELL Safety Pipe. Pipe systems for installations Technical details

Mikrotherm. Manual radiator valves. To be precise.

Packaged Terminal Air Conditioner Wall Sleeve Installation

Les Produits MURPHCO Ltée

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

LS 2540 SEWER LATERALS AND INSPECTION TEES

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD

SECTION SANITARY SEWER PIPE

Installation Instructions

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

HOSE, TUBE, AND PIPE CLAMPS

SITRANS F flowmeters SITRANS F M

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)


WHI 90-Minute Rated Veneered Door Frame Installation Instructions

MVX-Series Diesel Engine Air Shut Down Valves

This data sheet describes the most common joining methods of steel water mains and the most important phases of installation.

Pipe Clamps and Accessories

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Installation instruction CASAFLEX - Connecting piece DN 100

SIGRAFLEX . Properties. Applications

Quick Connect Boxes Inside Gloveboxes

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Front axle components, overview

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

RUBBER SLEEVE KNIFE GATE VALVE

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

Bypass level indicator With magnetic display Model BNA

Carlon Bore-Gard and Boreable Multi-Gard Raceway

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

HARTING Ethernet Cabling 8-poles Overview

Guidelines for Earthquake Bracing of Residential Water Heaters

Transcription:

GPD Rubber Press Seals Leading in in ideas SYSTEM-TECHNIK

GPD Rubber Press Seals Design Available with a rubber thickness of 30 mm for sealing against non-pressing water and a rubber thickness of 60 mm for The one-piece design is suitable for installation during For installation of the GPD after plumbing and wiring or under difficult conditions a divided design is required. All metal parts are of stainless steel. GPD - plugs the gap No matter if cable or pipe - system GPD always offers a safe solution. Rubber Press Seals can be inserted into the most varied pipe linings, diamond tipped drilled holes or entrance systems without any problems. For special applications please contact our technical department.

for for pipes Application and Function. Max. number of and diameter of grouping GPD (A)/1/(Z)x(D) (Z) = number of Rubber Press Seals GPD are used for protecting pipes and. They can be installed in a pipe lining as well as directly into a diamond tipped drilled hole. GPDs also serve as a guide and for acoustic uncoupling. When tightening the hexagon nuts the rubber disc is displaced by the press plates. Thus a secure and permanent sealing is accomplished even under water pressure that can be released at any time.. GPD (A)/1/1x(D) GPD (A)/2/1x(D) Max. number of and diameter of grouping GPD (A)/2/(Z)x(D) (Z) = number of Max. number of and diameter of grouping GPD (A)/G/2/(Z)x(D) (Z) = number of. GPD (A)/G/1/1x(D) GPD (A)/G/2/1x(D) On request rubber bore cores up to dia. 50 mm can be supplied free of charge. Product Nomenclature Example: GPD. Max. number of and diameter of grouping GPD (A)/G/1/(Z)x(D) (Z) = number of GPD (A) / G / F / 1 oder 2 / WE oder ST / (Z) x (D) diameter of cable or pipe (Øa) number of or pipes characteristic letter for type with connection piece characteristic letter for type with removable insert characteristic number 1 for characteristic number 2 for characteristic letter for type with overlapping flange characteristic letter divided design outside diameter of GPD

Pipe Linings General Pipe linings will be supplied fitting to the wall thickness of the structural works and are imbedded flush into the formwork. Plastic Pipe Lining with labyrinth glands and expansion seal coating on the outside. diameter 60 to 500 mm. FU-K (A)/(L) Fibre Cement Pipe Lining with labyrinth grooves on the outside. Asbestos-free material. diameter 80 to 1500 mm. FU-FZ (A)/(L) Flange suitable for sealing in front of a diamond tipped drilled hole in wall or ceiling. Available with flange gasket and fastening elements. Made of stainless steel. GPD-F-VA/(A) Upon supply our plastic pipe linings are closed with PE covers on the front side and are thus prepared for imbedding into the concrete. In case of fibre cement and stainless steel pipe linings special concepts for project-related applications are also possible, as e.g. design with integral and slip-on type flange (basement waterproofing) to DIN 18195 part 9. Stainless Steel Pipe Lining material no. 1.4301, with welded centre flange. diameter 60 to 1500 mm. FU-VA (A)/(L) Pipe Lining with integral / slip-on type flange to DIN 18 195 part 9. For sealing of waterproof sheeting (black basement lining). Made of stainless steel. diameter 60 to 1500 mm. FU-VA (A)/F+L/T9(N)D/L Divided Flange for subsequently sealing in front of a diamond tipped drilled hole in wall or ceiling. Available with flange gasket and fastening elements. Made of stainless steel. GPD-F-G-VA/(A) GPD Pipe Linings available in Special Design Special concepts for project-related applications as well as special sizes are available after technical clarification at short notice. Our field representatives will be glad to support you in planning. Product Nomenclature Example: Pipe Lining FU- K - FZ - VA (A) / (L) wall thickness pipe inside diameter stainless steel pipe lining fibre cement pipe lining plastic pipe lining We provide replacements for all parts which are impaired in their function due to faults in the material. No replacement for defects that are due to transport or storage or result from faulty processing or installation or the effects thereof. Our specifications are based on the current state of the art. Subject to technical modifications. Due to the amount of possible influences during installation and application our specifications do not release processors and users from checking and testing the material themselves.

Dimensional Table Dimensional Table Pipe Outside Diameter size in inches nominal diameter copper pipes steel pipes steel pipes with PE coating hard- - 1 st long distance heating lines CI sewage pipes with sleeves CI sewage pipes without sleeves (SML) and MI pipes SG ductile pressure pipes fibre cement pipes vitrified clay pipes (normal) vitrified clay pipes (reinforced) HDPE PN 2.5 / 3.2 HDPE PN 6 LDPE PN LDPE PN 10 high temp./canal/ plastic sewage pipes PVC pressure pipes PN 10 / 16 PP + ABS DIN 2439-41 19522 DN 17671 2448 19500 28610 19831 1230 1230 8074 8074 8074 8074 19534 19532 80778 3 / 8 10 12 17,2 16 12 12 15 16 16 20 16 16 1 / 2 15 18 21,3 20 20 25 20 20 3 / 4 20 22 26,9 31 90 25 25 32 25 25 1 25 28 33,7 38 90 32 32 40 32 32 1 1 / 4 32 35 42,4 46,5 110 40 40 50 40 40 1 1 / 2 40 42 42 52,5 110 50 50 50 63 50 50 48,3 2 50 54 53 65 125 60 58 64 78 ±3 63 63 63 75 50 63 63 57 60,3 63 2 1 / 2 65 76,1 76,1 80 140 75 75 63 75 75 (70) 80 78 84 75 90 75 75 90 (75) 105 ±4 90 3 80 80 88,9 93 160 98 90 90 88,9 168 180 4 100 104 102 112 180 112 110 118 116 132 ±5 110/ 110 110 110 110 108 108 119 200 125 114,3 114,3 5 125 130 133 137 225 137 135 144 141 160 ±4 125/ 140 125 140 125 133 139,7 144 140 140 6 150 154 159 163 250 162 160 170 168 187 ±4 160 180 160 160 160 159 168,3 173 266 180 180 280 200 208 219,1 224 315 212 210 222 220 242 ±5 262 ±5 160/ 225 200 225 200 219 334 180 225 250 (225) 355 200/ 250 225 225 250 280 250 267 273 278 400 274 274 274 270 296 ±6 318 ±6 250/ 280 250 280 250 280 280 315 300 324 323,9 450 326 326 322 350 ±7 374 ±7 315/ 355 315 355 315 355 400 350 355,6 500 378 378 404 ±7 430 ±7 400 355 400 400 406,4 560 429 429 432 460 ±8 490 ±8 400 450 450 457,2 630 486 524 ±8 548 ±8 450 500 508 670 532 532 573 581 ±9 607 ±9 500 560 560 600 609,6 635 646 687 ±12 721 ±12 630 630 700 711,2 738 750 790 ±15 831 ±15 710 800 812,8 842 856 895 ±17 941 ±17 800

GPD Variants and Special Solutions GPD rubbers are made of EPDM. As an option, they are also available in NBR. Rubber Press Seals are available in numerous variants and designs. GPD with connection pieces a combination of the rubber press technique and the shrink-on technique. With 1 to 8 connection pieces suitable for and pipes. GPD (A)/2/ST/(Z1)x(D1) (Z1) = number of connection pieces (D1) = inside diameter of connection pieces GPD with removable insert for changing repeated groupings, suitable for GPD (A)/G/2/WE(A1)/(Z)x(D) GPD with overlapping Flange available as one-piece or divided design, for non-pressing and pressing water. One-piece design: GPD (A)/F/(1or2)/(Z)x(D) Divided design: GPD (A)/G/F/(1or2)/(Z)x(D) The GPD Idea Suitable for the distribution of electricity, gas and water in structural and civil engineering. For diamond tipped drilled holes and pips of all diameters. Subsequent installation for already laid and pipes possible. Gas- and watertight up to 10 bars. Soundproof. Elastic bedding of or pipes, i.e. shocks are absorbed. Basement waterproofing according to DIN 18195 part 9, integral / slip-on type flange. More efficiency due to short installation time. Grouping table Inside Z=1 Z=3 Z=5 Z=9 order no. d. t. dr. hole/ cable/pipe /pipes /pipes /pipes divided GPD for pipe lining in mm in mm in mm in mm 60 mm up to 34 up to 20 up to 12 up to 8 GPD 60/G/2/(Z)x(D) 80 mm up to 45 up to 25 up to 16 up to 12 GPD 80/G/2/(Z)x(D) 100 mm up to 66 up to 30 up to 22 up to 15 GPD 100/G/2/(Z)x(D) 125 mm up to 87 up to 40 up to 35 up to 22 GPD 125/G/2/(Z)x(D) 150 mm up to 112 up to 50 up to 40 up to 28 GPD 150/G/2/(Z)x(D) 200 mm up to 162 up to 70 up to 60 up to 43 GPD 200/G/2/(Z)x(D) 250 mm up to 212 up to 85 up to 70 up to 50 GPD 250/G/2/(Z)x(D) 300 mm up to 260 up to... up to up to GPD 300/G/2/(Z)x(D) 350 mm up to 300 GPD 350/G/2/(Z)x(D) 400 mm up to 350 GPD 400/G/2/(Z)x(D) 450 mm up to 400 GPD 450/G/2/(Z)x(D) 500 mm up to 450 GPD 500/G/2/(Z)x(D) GPD with Replacement Insert Inside dia Z=3 Z=5 Z=9 order no. d. t. dr. hole/ divided GPD for pipe lining dia in mm dia in mm dia in mm 100 mm up to 22 up to 17 up to 12 GPD 100/G/2/WE65/(Z)x(D) 125 mm up to 30 up to 24 up to 16 GPD 125/G/2/WE85/(Z)x(D) 150 mm up to 42 up to 34 up to 24 GPD 150/G/2/WE110/(Z)x(D) 200 mm up to 50 up to 38 up to 27 GPD 200/G/2/WE125/(Z)x(D) (A) (A1) (Z) (D) = outside diameter of GPD inside diameter of diamond tipped = outside diameter of replacement insert = number of to be sealed = diameter of individual Other combinations with different diameters are also possible. Sealing systems and fire protection for and pipes UGA SYSTEM-TECHNIK GmbH & Co. Technical Systems and Products for integration into buildings Heidenheimer Str. 80-82 89542 Herbrechtingen Postfach 12 61 89539 Herbrechtingen Phone: 0049 73 24 / 96 96-0 Fax: 0049 73 24 / 96 96-96 e-mail: info@uga-systeme.de internet: www.uga-systeme.de