Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.



Similar documents
Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Water Main Lining A Sustainable Alternative to Open Cut Replacement

Ultraviolet (UV) Light Cured Fiberglass Reinforced Cured-In-Place Pipe (CIPP) It is not just for sanitary sewer rehabilitation

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

Introduction to Pressure Pipe Rehabilitation with CIPP

Superior Pipe Restoration Solutions. Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

Structural Lining for Water Mains. Presenters: Stephen Marcino, PE and Micah Blate, EIT (JMT)

Using StrongPIPE Hybrid FRP for PCCP Rehab in Miami-Dade System

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

CIPP for Large Diameter Pressure Pipes. Water Research Foundation Large Diameter Pipe Rehabilitation Seminar 20 January 2016 George Bontus, P.Eng.

Wastewater Capital Projects Management Standard Construction Specification

REHABILITATION OR REPLACEMENT? THAT IS THE QUESTION

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

The leader in trenchless rehabilitation

THE ECOLOGICAL IMPLICATIONS OF TRENCHLESS PIPE REHABILITATION

INSTALLATION OF INSITUFORM LINER

Oil and Gas Pipeline Design, Maintenance and Repair

PORTLAND BES ADVANCES IN SEWER MAINTENANCE AND REPAIRS BY OPERATING MULTIPLE CIPP CREWS.

Rehabilitation or Replacement? That Is The Question

Repair or Replacement - Band-Aids vs. Surgery

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

SPR PE Steel Reinforced Liner

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

epros DrainLiner Program

PRESSURE PIPE REHABILIATION CIPP TECHNOLOGIES

CURED-IN-PLACE PIPE MINIMIZING RISK BY DEFECT CODING

FY15 Gravity Sewer and Manhole Rehabilitation

GENERAL SPECIFICATIONS AND GUIDELINES FOR INSTALLATION MASTERLINER CURED-IN-PLACE PIPE SYSTEMS

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

LS 2540 SEWER LATERALS AND INSPECTION TEES

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

Trouble Shooting for Trenchless Liner Installation During Sewer Line Rehabilitation

IS THAT LINER THICK ENOUGH?

Appendix A: Acceptable pipe and fitting materials

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

BKP Berolina Polyester GmbH & Co. KG. Berolina-Liner System Lightspeed in gravity pipe rehabilitation!

SIDE SEWER CONDITION ASSESSMENT AND REPAIR RECOMMENDATIONS

DEPARTMENT OF ENVIRONMENTAL QUALITY

Waste Collection Systems

Sewer Pipe Lining An Economic Solution for Pipe Rehabilitation By Tawana Albany Nicholas, Virgin Islands Waste Management Authority


SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

CCTV PIPE INSPECTION AND EVALUATION RUNWAY 17L-35R

Large Bore Rectangular Box Culvert and Non Circular Rehabilitation with CIPP

Summary 7/11/2012. Michigan Water Environment Association 2012 Annual Conference Boyne Mountain Resort

Where life interacts with infrastructure.

Utilizing Remaining Useful Life for Asset Management of Critical Wastewater Assets

Rainwater going astray. EPROPOX FC30 epoxy resin system to be prepared for a rainy day

The Environmental Implications of Road Culvert Repair Technologies. Bridget Donaldson Senior Research Scientist

Flowtite Jacking Pipe

Meeting the Challenge of Pipeline Emergency Repair

APPLICATION OF GLASS-REINFORCED PLASTIC TO SEWER REHABILITATION

Township of Enniskillen. Asset Management Plan

Measuring the Condition of Prestressed Concrete Cylinder Pipe

ENGINEERING DESIGN GUIDE FOR REHABILITATION WITH CURED-IN-PLACE PIPE Second Edition

CONSTRUCTION OF NON-CIRCULAR SEWER REHABILITATION PROJECTS IN LOS ANGELES

Sewer systems: Failures and rehabilitation

Installation of Large Diameter Buried Pipes

Session: HDPE Pipe Test Rafael Ortega, Vice President, Lockwood, Andrews & Newnam

PRODUCT CATALOGUE. for. SMARTPHONE / WEBSITE / DIGITAL EDITION / BOOK / ipad / GPS

SOLVING SECONDARY CONTAINMENT PROBLEMS

SA Pipe Relining is dedicated to finding simple, non intrusive

TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING

Prestressed Concrete Pipe Fitness for Service and Repair

Amendment 1 Preliminary Engineering Report for the City of Salida

CHAPTER 6 - SANITARY SEWER

Published in Pipelines 2001 Proceedings of the Conference American Society of Civil Engineers Held July 15-18, 2001, San Diego, California

Water Transmission & Sewer Force Main Renewal 16 through 60

Rehabilitation of an Aging Concrete Reservoir Adit Tower

SECTION 3 SANITARY SEWER DESIGN

STANDARD SANITARY SEWER REHABILITATION SPECIFICATIONS

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Section 2320 Cured-In-Place Pipe Lining

CCTV of Stormwater Systems. Cairns Regional Council. Commentary Guidelines #

WEKO-SEAL Internal Joint Sealing WEKO-SEAL. internal pipe-joint sealing

Sewer Rehabilitation Design Requirements

Demonstration of an Innovative Large-Diameter Sewer Rehabilitation Technology in Houston, Texas

REPAIRS TO DAMAGED SEWERS

MAPEI s Resfoam polyurethane products

Transcription:

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems. Aging pipeline infrastructure and industry s inability to evaluate and inspect has left many engineers and plant managers looking for solutions. Up until recenly pipeline integrity management has had a low priority while serious issues have been passed on for this generation of managers to solve. Responding to heightened awareness of the significant environmental, safety and economic consequences of corrosion and erosion of pipelines, industry has finally begun to look for answers. The good news is private companies have responded with some innovative and cost effective solutions. Pipeline corrosion and failure is an environmental safety issue, it is an economic issue and it is a job retention issue. Pipeline Corrosion waste resources, results in environmental contamination and costs jobs. Companies find it less expensive to outsource overseas than to maintain facilities in the United States. Though there has been a great breakthrough the chemical engineering of adhesives and coating materials to extend and repair pipelines there has not been a practical way to apply these materials to pipelines while in service. It has only recently has a remote relining system been developed to offer industry an effective way of delivering these new hybrid polyurea materials. Deferred maintenance and poor planning has resulted in the current generation of plant managers and engineers having to deal with issues that were not thought about 30 years ago when pipelines were installed. Budget line items did not take into consideration the possibility of catastrophic failure or major breaks. Until just recently most industry has been in a bandaide mode, putting out fires when a serious problem finally forces action. History During the mid 1990 s Polyurea application companies were very interested in changing their market strategy to focus on the pipeline rehabilitation. They were looking to develop a system that would provide improved performance characteristics over those of the leading treachless industry

technology know as Cured in Place Piping, (CIPP). One of the first applications using polyurea lining involved a major automobile manufacturer in the Detroit area. Many of these older plants had old storm sewer systems with environmental concerns. Their primary concern was the infiltration of Polychlorinated Biphenyls (PCB s) from plant waste that had leached into the ground over the years. These storm systems contained reinforced concrete pipe (RCP) with diameters from 30 to 48. A number of these storm drains had been previously rehabilitated with CIPP. However due to the nature of the thermosetting resin used in the process radial shrinkage occurred during the curing process and created a void between the host pipe and liner. The existence of this annulus negated any beneficial effects of the CIPP lining process as it provided a path for the PCB s in the groundwater to backtrack between the liner and host pipe. This condition continued to allow PCB contaminated ground water to flow back into the uncontrolled environment. In order to correct this condition, a methodology was developed to utilize a combination of a packing cord, stainless steel retaining bands and a semi structural polyurea in a multi layered configuration. This method when implemented per the technical specification requirements successfully provided rehabilitation to effected storm drains and attenuated the infiltration of PCB s into the environment. This successful implementation of using Polyurea technology for pipeline rehabilitation is what spurred the initial ideas of Mr. Kent Weisenberg to develop the current remote lining device that Dallas 1 Rehabilitation Solutions calls RASR, (robotically applied spray rehabilitation). The CIPP installation companies were generating huge revenues for a system that basically had several intrinsic flaws and fundamentally did not work. Mr. Weisenberg s extensive background in polyurea and its versatile application potential, led to the possibility to develop a system that had the ability to rehabilitate pipelines without all the inadequacies of the current trench less methods.

Market Necessity A 2002 study of the US infrastructure needs by the Environmental Protection Agency confirmed that the buried transmission and distributions pipeline system is in imminent and extensive need of rehabilitation. As the infrastructure reaches the end of its design life, renovation and replacement industries servicing this requirement shall continue to grow. Currently $80 billion per annum is spent in the US on pipeline renovation. The cost of pipeline remediation is not just measured by the direct cost of the intervention, but additionally by indirect economic impact of disrupted traffic, plant close downs, reduced production and consequent cost to business. It is estimated that this economic impact is nearly twice as expensive as the actual remediation. Pipeline infrastructure systems worldwide are starting to fail with increasing regularity. Over the last century, various support systems providing essential services such as drinking and wastewater have been developed. These pipelines have been buried under a growing surface of infrastructure and are now rapidly reaching the end of their design lives. Conventional repair or replacement of such systems results in significant disruption of surface facilities, such as road, building, and manufacturing plant closers. The Trenchless Technology industry came to prominence in the mid 1970 s when a British company Insituform invented a process called Cured in Place Pipe (CIPP). The process involves the insertion of a felt sock, which is impregnated with resin) polyester or epoxy). The resin sets, usually by using elevated temperatures and forms a structural composite pipe inside the original line. Since the mid 70 s CIPP has rapidly developed and is now estimated to be worth around $2 billion per annum. Trenchless remediation is rapidly becoming the preferred solution, preventing excavation, saves money, takes less time, creates fewer community hazards and can significantly reduce indirect economic costs. Trenchless remediation is growing its market share in a rapidly growing market and today over 50% of the pipelines are rehabilitated using Trenchless techniques. Remediation and repair is forecast to grow as municipal and industrial operations attempt to maximize the useful life of the original infrastructures.

With significant scientific advances in the polyurea technology a huge market place has been opened up for the remote lining of pipe. With considerable help from the Polyurea Development Association the new area of rehabilitation promises to solve many problems that were not anticipated when much of the current pipeline infrastructure was placed in service years ago. Design considerations Below is a summary of the design and challenges encountered in developing the RASR (Robotically applied Spray Rehabilitation) remote application system. Please note that this explanation was written to be easily understood as a non technical design and implementation review. The coating industry is currently designing and utilizes several polyurea formulations in lining applications. The most commonly used formulation is for the structural rehabilitation of fully deteriorated pipe. The load design calculations for these liners are solely based on ASTM F-12 specifications. The current polyurea formulation s flexural modulus is approximately 400,000 psi. Based on the load equation of this ASTM specification one can see that liners for full remediation of even small diameter pipe requires liner thickness in excess of 500 mils. Wall thickness can be varied according to desired results and life expectancy of the substrate. The following is a list of current design capabilities. 1. The RASR unit can apply polyurea liners in pipe diameters from 5 inch through 72 inch. 2. RASR can apply any thickness of polyurea from 1/8 inch through 3 inches. This is not contingent on pipe diameter. It is simply controlled by proper calibration of flow/traversing speed/oscillation/reciprocation. 3. RASR can negotiate, while keeping articulating head center line to spray up to 45 degree bends or sages in pipe. 4. RASR can apply polyurea lining with traversing speeds of up to six feet per minute. 5. RASR can apply pure polyurea or hybrid at any desired thickness, with a get time from four to eight seconds. 6. RASR sends video signal for both forward and reverse viewing color cameras to maintain visual inspection of lining process.

7. RASR can facilitate start and stop functions for the application of structural or sealing sleeves when pipe is not to be full lined. 8. RASR has the ability to line any spherical pipe, elliptical pipe, CMP and concrete box pipe. 9. RASR can be calibrated to apply a symmetrical liner or can vary thickness on the top or bottom of pipe such as in the case of a severe hydrogen sulfide vapor/sulfuric environments in RCP. 10. Unit has the ability to remotely line stand pipes and vertical piping systems. Summary: It is hoped that this paper has provided an informative and interesting review of the current and future development of pipe lining with polyurea. While many challenges were overcame to provide the present level of achievement new ones will always be there as the industry continues to grow this technology in the future. The significant developments discussed in this paper provide the industry with several options with the use of robotics and polyureas as solutions to pipelining and maintenance problems. Vito Saputo Dallas 1 Rehabilitation Solutions Tampa, Florida