The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform



Similar documents
The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform.

Eclipse ABR - OAE - ASSR. Results you can trust. Interacoustics. l e a d i n g d i a g n o s t i c s o l u t i o n s

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

Integrating best practice in hearing care

KEYPOINT XP EDITION. Invented for Value and Performance. A Good Diagnosis is Half the Cure

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER. Setting The Clinical Standard

DIAGNOSTIC TESTING GUIDELINES for Audiology

Hearing Tests And Your Child

Paediatric Hearing Assessment

Once your baby has good head control and can turn towards something interesting, a more advanced behavioural procedure can be used.

Hearing Tests And Your Child

Everybody has the right to

The Healthy Hearing Program Diagnostic Assessment Protocols for Audiological Practice

Product Line for Hearing Screening & Diagnostics

Case Study THE IMPORTANCE OF ACCURATE BEHAVIOURAL TESTING IN INFANT HEARING AID FITTINGS

COCHLEAR NERVE APLASIA : THE AUDIOLOGIC PERSPECTIVE A CASE REPORT. Eva Orzan, MD Pediatric Audiology University Hospital of Padova, Italy

Pediatric Hearing Assessment

Effects of Noise Attenuation Devices on Screening Distortion Product Otoacoustic Emissions in Different Levels of Background Noise

Fundamental Components of Hearing Aid Fitting for Infants. Josephine Marriage PhD

Hearing Tests for Children with Multiple or Developmental Disabilities by Susan Agrawal

Tonal Detection in Noise: An Auditory Neuroscience Insight

OAE hearing screening at your fingertips OAE+

Air Conduction Audiometer Series. MA 27 with headphones and built-in carrying case. MA1, MA25 & MA27.

PURE TONE AUDIOMETER

UKAS Technical/Peer Assessor Keyword List AUDIOLOGY

Using Your Fitting Software This guide provides comprehensive, task-based information about all the fitting software features.

Everything you need for protection scheme testing

A Guide to Otoacoustic Emissions (OAEs) for Physicians

GSI AUDIOSTAR PRO. Free Call: CLINICAL TWO-CHANNEL AUDIOMETER. Australian Distributer:

Official CPT Description

Captus 3000 Thyroid Uptake And Well System

Full line of hearing and balance

How can I manage all automation software tasks in one engineering environment?

LMS Test.Xpress Powering personal productivity

MA33 & MA55. PC Based Audiometers. The ideal choice for health care professionals on the go. by Maico Diagnostics

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

FREQUENCY RESPONSE ANALYZERS

RF Network Analyzer Basics

PURE TONE AUDIOMETRY Andrew P. McGrath, AuD

REGULATIONS FOR THE DEGREE OF MASTER OF SCIENCE IN AUDIOLOGY (MSc[Audiology])

PRODUCT SHEET OUT1 SPECIFICATIONS

EVIDENCE-BASED BIOMECHANICS

Understanding Hearing Loss

Estimation of Loudness by Zwicker's Method

Pediatric Whitepaper. Electrophysiological Threshold Estimation and Infant Hearing Instrument Fitting

AUDIOLOGICAL EVALUATIONS, FINDINGS AND RECOMMENDATIONS: A PARENT S GUIDE

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

CA Service Desk Manager

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

Questions and Answers for Parents

Neurodiagnostic Equipment Solutions

Australian Hearing Aided Cortical Evoked Potentials Protocols

PROFESSIONAL BOARD FOR SPEECH, LANGUAGE AND HEARING PROFESSIONS STANDARDS OF PRACTICE IN AUDIOLOGY

What Is the Audiological Evaluation Time for those Aged 0-5 Years and Older?

ONTARIO INFANT HEARING PROGRAM AUDIOLOGIC ASSESSMENT PROTOCOL. Version 3.1, January 2008

REVENUE CYCLE MANAGEMENT MADE EASY

CLIO 8 CLIO 8 CLIO 8 CLIO 8

Type-D EEG System for Regular EEG Clinic

Timing Errors and Jitter

Voltech DC1000. Precision DC Bias Current Source

Practice Standards for Hearing Service Providers

Pros and Cons: Including High Frequency (1000 Hz) Ipsilateral Acoustic Stapedial Reflexes in UNHS

The Sievers 900 Series TOC Analyzers

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

New ECDL. Frequently Asked Questions

LM381 LM381A Low Noise Dual Preamplifier

RF System Design and Analysis Software Enhances RF Architectural Planning

Impedance 50 (75 connectors via adapters)

Ultrasound Condition Monitoring

1000+ AUDIOMETER OPERATING INSTRUCTIONS

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

One Port Network Analyzer

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

our group Mission Overview Offering

SUPERIOR EYE TRACKING TECHNOLOGY. Totally Free Head Motion Unmatched Accuracy State-Of-The-Art Analysis Software.

Cable Analysis and Fault Detection using the Bode 100

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Diagnostic Tests for Vestibular Problems By the Vestibular Disorders Association

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

Sample Exam Foundation Level Syllabus. Mobile Tester

CARE HOME MANAGEMENT SOFTWARE

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Make your practice more efficient in a heartbeat.

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

CBS RECORDS PROFESSIONAL SERIES CBS RECORDS CD-1 STANDARD TEST DISC

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

PSM 900 and PSM 1000 Personal Monitor Systems TWO SYSTEMS. INFINITE POSSIBILITIES.

CALIFORNIA CHILDREN S SERVICES MANUAL OF PROCEDURES 3.42 STANDARDS FOR INFANT HEARING SCREENING SERVICES

QPR WorkFlow. Minimize Process Time, Maximize Process Outcome. QPR WorkFlow 1

NEW YORK STATE MEDICAID PROGRAM HEARING AID/ AUDIOLOGY SERVICES PROCEDURE CODES

R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz

THE LEADING AUDIOLOGY CLINIC MANAGEMENT SYSTEM

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Audiometry and Hearing Loss Examples

Transcription:

The Eclipse Designed to meet your every need AEP, ASSR, VEMP & OAE testing on one dedicated platform

Design your own diagnostic solution for a perfect result The Eclipse is a modern and versatile platform. It is designed to fit seamlessly into your everyday workflow and to offer complete reliability and perfect results. Have it your way We all strive towards a common goal: To achieve reliable test results to screen or diagnose patients accurately and efficiently. Whatever your challenge may be, the Eclipse hardware platform enables you to focus on the job at hand with the assistance of dedicated software modules for all facets of auditory evoked potentials and otoacoustic emissions. Making complicated things easy A range of pre-loaded test protocols are available in each software module ensuring that you will quickly feel confident. After getting acquainted with the software you can add or modify test protocols and tailor them to your specific needs. The clear layouts allow you to easily interpret the results and focus on the essential outcomes of the test, which can be saved into the OtoAccess TM database for easy retrieval, review and export to your EMR in XML format. Are you future-safe? Every Eclipse software module is developed based on proven technologies and feedback from users and audiology experts. Features are developed in sync with your changing needs and contain the latest technologies making the Eclipse a future-safe investment. A preview of the benefits Solid & noise immune hardware Modular and future-safe platform Unique pre-amplifier technology ensures optimum performance in electrically hostile environments Intuitive interfaces, well-designed layouts, freedom to customize settings Windows 8 and 7 compatible 2

Silence is the Key The Eclipse preamplifier provides unrivalled stealth with only 4nV of internal noise 3

Software modules for any challenge Database NOAH Data Storage & Sharing OtoAccess TM Data Storage & Sharing Todd B. Sauter, M.A. Audiology Associates of Worcester Massachusetts The Eclipse has the largest number of clinically-relevant features of any AEP device today. The platform is an excellent blend of parameter flexibility and user-friendliness. 4

ABR EP25 ABR, MLR, LLR, P300, MMN, ECochG, eabr EP15 ABR ABRIS Automated ABR screening ASSR Threshold assessment OAE DPOAE20 Screening and clinical DPOAE TEOAE25 Screening and clinical TEOAE Balance VEMP cvemp ovemp 5

CE-Chirp Stimulus Family The Gold standard for threshold assessment Auditory Evoked Potentials Traditional Click CE-Chirp LS Stimulus 6

New technologies. New standards. New ABR. Residual Noise Calculation knowing when to stop Reducing noise is the single most important factor for improving any evoked potential recording. The residual noise calculator provides you with the knowledge of when to stop averaging, often saving test time and ensuring confidence in response identification. CE-Chirp Stimulus Family Double your response amplitudes The revolutionary CE-Chirp stimulus family for threshold assessment (developed by Claus Elberling) compensates for frequency specific cochlear travel times and generates waveform responses up to twice the size of traditional click or tone burst stimuli. The original CE-Chirp was designed for optimal response amplitude at medium stimulation intensities. By using the level specific CE-Chirp, clearer waveform morphology at high intensities is also available. The introduction of the CE-Chirp LS stimulus family is an overall improvement to the original CE-Chirp stimulus family. For an easier visual evaluation of the NB CE-Chirp responses, each of the NB CE- Chirp stimuli have been time shifted to provide latencies similar to Click and the CE-Chirp LS stimulus. The time-shifted NB CE-Chirp are named NB CE-Chirp LS, as the placements are level specific. Otherwise, the NB CE-Chirp LS are identical to the original NB CE-Chirp. The CE-Chirp stimulus family is incorporated in the EP25 (*optional for EP15) and ASSR software modules from Interacoustics. Bayesian Weighting saves you valuable time Using Bayesian Weighting during your ABR recording ensures that waveforms remain stable even during periods of patient activity. The influence of patient noise is minimized during the recording, resulting in continuously lower noise in the running average, saving valuable test time. Fmp improving confidence Imagine having an objective waveform confidence indicator to assist you in confirming the presence or absence of a response. The Fmp graph provides objective, mathematical and quantitative information based on multiple points within the recording to assist with your waveform analysis. Use of the Fmp provides a reduction in test time and confidence in your diagnosis. The online display of the Fmp serves as a calculated response confidence. In this example, 99% response confidence was exceeded after only 1500 sweeps. Rather than testing for a certain number of sweeps, the residual noise should be used as a stop criteria. 7

EP15, EP25 and ABRIS From screening ABR to specialized AEP ABRIS Fast and objective ABR screening ABRIS is a fast screening software that can be used for all age groups. It returns a simple pass/refer result, requires minimal tester training and is automatic and objective. Just click START After attaching the electrodes and making a quick impedance check simply click Start and you are set to go. EEG monitoring is provided with a continuous graphical display and no measurements are collected during periods of unacceptable noise. Results are clearly displayed in: Green for Pass and Red for Refer it s that easy! 99.7% don t settle for less Vestibular EP We offer a special version for the vestibular clinic with protocols such as VEMP, ECochG and rate study tests. ABRIS specificity (the ability to correctly exclude normal hearing babies) is as high as 99.7% in large scale clinical trials using two stage screening. ABRIS sensitivity (the ability to correctly identify babies with hearing problems) is 99.99% based on large-scale simulations. 8

EP15 Diagnostic ABR EP25 Clinical AEP Developed for clinics performing standard threshold and neurological ABR testing, the EP15 will allow you to do a com mon task surprisingly well. For those who need specialized procedures requiring the full spectrum of AEPs: Go for the advanced EP25 software. A new standard The contemporary interface delivers unrivalled ease-of-use and superior clarity, which will help you achieve clear and reproducible results in a confident and timely manner. Pre-loaded protocols peer-reviewed by key-experts, easy tailoring of manual and automatic test protocols and a multitude of useful tools make the Eclipse the preferred choice for threshold and neurological ABR. For your daily routine Threshold & neurological ABR testing & eabr Bayesian weighting Residual noise calculator Fmp calculator SNR 3:1 ratio calculator CR, RA, INC waveform markers Normative latency data for click, CE-Chirp, NB CE-Chirp, CE-Chirp LS & NB CE-Chirp LS Single/split screen CE-Chirp, NB CE-Chirp, CE-Chirp LS & NB CE-Chirp LS for optimized threshold assessment (optional) CM & ECochG testing (optional) The benefits of specialized features The EP25 contains all the useful features found in the EP15, but adds the extra functionality needed by more specialized clinics. The EP25 incorporates a full range of test protocols covering the early, middle and late latency tests. EP25 all the features of EP15 and this: AMLR, ALLR & P300/MMN testing CM & ECochG testing ECochG Area Ratio Calculation by John Ferraro CE-Chirp, NB CE-Chirp, CE-Chirp LS & NB CE-Chirp LS for optimized threshold assessment Displaying Right and Left ear in a split screen format is beneficial when performing threshold work. Unique ECochG Area Ratio Calculation implementation. 9

ASSR Where speed meets accuracy The Interacoustics ASSR system reduces test times by 50% thanks to Narrow Band CE-Chirp stimuli and new powerful automated dual response detection methods. 10

A new (and faster) generation Interacoustics ASSR represents a true breakthrough and a new generation in ASSR threshold estimation. The ASSR software enables 8 frequencies to be tested simultaneously to threshold in less than 20-30 minutes through the use of Narrow Band CE-Chirp stimuli and a patented detection engine. Full control full speed You will dramatically shorten test time as you are in full control of selecting the appropriate stimulus levels independently for each frequency based on current and previous results. Also, you are able to change the stimulation rate during testing depending on the state of your patient. All in all: Full control allows full agility and speed. Cut test times in half The Interacoustics ASSR software uses the Narrow Band CE-Chirp stimuli to generate a maximal response, which makes the detection fast and efficient. The dual detection engine evaluates both the phase and the response magnitude from 12 of the higher harmonics of the fundamental modulation rate. This patented technology can reduce test time by 50% compared to traditional ASSR systems and offers unsurpassed accuracy. Save data directly to NOAH The estimated audiogram generated by the Interacoustics ASSR can be saved to NOAH. The estimated audiogram can easily be transferred to Genie or other similar hearing aid fitting software, ensuring a smooth and accurate hearing aid fitting. ASSR detection. ASSR audiogram. 11

12

DPOAE20 TEOAE25 Otoacoustic emissions DPOAE20 Distortion product emissions The Eclipse hardware platform accommodates both DPOAE & TEOAE capabilities. Shared features and benefits Lightweight probe with low internal noise Easy to place in the ear Inexpensive to maintain Auto probe check determines correct placement Validity checkmarks for OAE detection confirmation User-controlled noise sensitivity and rejection for easier collection The DPOAE20 module produces detailed DP Grams with protocols designed by the user for their preferences or requirements. Build your own customized normative data sets or use the supplied norms from Interacoustics. TEOAE25 Transient evoked emissions The TEOAE25 uses linear or non-linear broad band clicks to evoke otoacoustic emissions. The extensive range of clinical options provide a full clinical evaluation of TEOAEs. The TEOAE25 also has protocol settings for automatic display of a pass/ refer result for hearing screening. Factory defaults are also available. 13

Optimize VEMP through visual feedback Vestibular Investigation The Eclipse ovemp and cvemp tests measure and analyse the vestibular evoked myogenic potential generated by a loud stimulus. Instant visual feedback increased quality Valid cvemp results are dependent on correct and controlled EMG tonus. The VEMP software provides visual feedback of the muscle contraction to assist you in helping the patient to obtain correct muscle tonus throughout the entire test. This can be done from the software or on a separate patient monitor for cvemp testing. Complete system Combine VEMP with the Interacoustics VNG system for a complete balance system. EMG-based scaling - a reliable result By applying EMG-based scaling of the obtained waveforms, you are ensured a crucially important balanced presentation of responses from Left and Right ensuring a confident and reliable result. High output stimuli The Eclipse VEMP can stimulate up to 100dB nhl with clicks, 250Hz, 500Hz, 1kHz, 2kHz and 4kHz tone bursts. 14

Automated VEMP ratio calculation The difference between ears is calculated automatically using the VEMP ratio. Simply mark two places on the VEMP curve and the software will calculate the VEMP ratio.

Interacoustics a/s Interacoustics is a world leading diagnostic solutions provider in the field of hearing and balance assessment. We help the professional audiological world reach new milestones through continuous developments and a constant focus on integration and direct customer value. With you at all times Whenever you purchase audiological equipment with the Interacoustics brand on it, you are not just guaranteed a quality product but also highly trained support personnel with specialized knowledge. We operate in over 100 countries worldwide through a carefully selected network of distributors and service centres to ensure that you receive total support and service. Product specifications All technical and hardware specifications concerning software modules and the Eclipse platform can be downloaded from our website. Read more at interacoustics.com Interacoustics a/s Drejervaenget 8 DK-5610 Assens T +45 6371 3555 F +45 6371 3522 info@interacoustics.com interacoustics.com Go online to explore our full product range ABR/OAE Balance Assessment Fitting Systems Middle Ear Analyzers Audiometers Interacoustics a/s - 8101800-3 - 10/2014