Construction details. Technical specifications

Similar documents
Rockwool Cladding Roll

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Composite Panel Firewall Systems

FIREWALLS FIREWALLS. Technical specifications

PROFILED METAL ROOFING DESIGN GUIDE

Corus Panels and Profiles. Roof and Wall Composite Panels

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Design and installation recommendations. August 2007

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

Colorcoat Urban The choice you ll be glad you made. CI/SIB (4-) Nh2 March 2012

A few good reasons to have a conservatory. The conservatory structure

METAL ROOF AND WALL CLADDING SYSTEMS

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

Thermal Performance of Steel Beam Junctions using Different Connection Methods

Kingspan Roof Tile. Insulated Panels. Insulated Tile Effect Roofing System. Building to the Power of. CI/SfB. September 2008

VM ZINC : standing seam Guidelines for specification and installation

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

V-joint fascia soffit systems

When considering Roof drainage design the following should be taken into account:

Longspan. Insulated Panels. Architectural Frame to Frame Insulated Panel System. CI/SfB (4-) Rh2 September 2008

Conservatory Roof Structural Information Guide

Module 3.7. Thermal bridging

Rockwool Flexi Insulation Application Guide

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Multi-layer Insulation Blanket for Roofs

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Fire Resistant Systems

The Warm Edge for insulating glass

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

KAHU RESIDENTIAL ROOFING RRKA DETAIL LIST

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

I-Line - Snap-On Feature

Peninsula Place, Greenwich, London

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Fixed Vertical Access Ladders

The formation of roof waterproofing details calls for

Confort 26. Sliding Systems. Sapa Building System

Ubiflex. Non-lead flashing system

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Upstand Rooflight Natural Light Translucent Upstand Systems

FIRE RATED GLAZING System Guide

Preformed Metal Roofing and Siding

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Leaky Homes Financial Assistance Package (FAP) Repair plan example

MULTI ROOFING. Our Services.

KALZIP STANDING SEAM ROOF SYSTEMS KALZIP DECK ROOF SYSTEM

rationel WINDOWS WITH VISION

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Installation Detailed installation instructions are provided which should be strictly followed.

HANLO The WELCOME HOME Experience.!! Simply better homes!!

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

DENVER MODEL 30 X 30 SPECIFICATIONS

Services Enclosures and Protected Shafts - Maintaining Compartmentation

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Plaisance 24. Sliding Systems. Sapa Building System

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

The Kingspan Insulation Price List 1 st January 2013

SECTION STANDING SEAM METAL ROOF

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

How To Build A Gambrel Roof And A Gable End Roof

Architectural composite panels

PB301 July Lightweight Building Solutions. Bushfire Protection.

Residential Roofing Guide

Trisomet External roof and wall panel system

ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE. Building Solutions Automotive Industry

Partitioning & Ceiling Product Information

Timber Frame Walls Rethinking Construction

What a good idea! Turn your conservatory into an all-year-round living space.

SECTION PREFORMED METAL STANDING SEAM ROOFING

Conservatory roof system designed without compromise - tested to the highest standards

RESIDENTIAL METAL BUILDING COMPONENTS

Asbestos in the home. A guidance booklet for tenants. Please keep this document as a reference guide- It contains important safety information

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Proteus Waterproofing roof systems are tested to the most rigorous international standards, ensuring they will easily deal with our climate.

Sun Windows General Information Sun New Construction Window Installation Instructions

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Energy Company Obligation (ECO): Technical Monitoring Questions

Concrete Waterproofing Systems. Integral Protection.

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

Loss Prevention Standard

Comment Form on Proposed Gut Rehabilitation Alternatives

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

Product Catalog. Extreme Roofing, Inc Rt. 982 Mammoth, PA

Glass partitions SFB 3074

DELTA Premium Moisture Management Systems for Foundations.

ROOFS - Guidance for Repair, Maintenance and Replacement

Steel-framed Walls. Insulation

Detached accessory structures that contain no conditioned floor area are exempt.

Transcription:

Construction details Technical specifications

Construction details CONTENTS Introduction 3 Typical building 7 Thermal performance of built-up systems 8 Built-up roof constructions 14 Built-up wall constructions Corner details 16 18 1 Ridge/Hip details 20 Gable/Verge details 22 Mono ridge details 24 Roof abutment to side details 26 Roof abutment to end and apron details 30 Valley/Parapet gutters and internal hips 32 Eaves and gutter details 36 Door and window head details 38 Door jamb details 40 Window jamb details 42 Cill and drip details 44 Corus Colorcoat products and services 46 Notes and contacts 48

Introduction 2

INTRODUCTION Construction details Introduction Founded in 1980, Euroclad is one of the UK s leading manufacturers of steel and aluminium roofing and cladding systems. Main brands, including Elite Systems, Euroseam and Secret fix, have become increasingly popular with architects and contractors: the core metal profiling activities being complemented by a full fabrications and flashings capability. Synonymous with reliable service and outstanding technical support, Euroclad has strong links with leading manufacturers for specific system elements. To help customers better understand the thermal performance of metal clad buildings Euroclad have prepared Construction Details, showing thermal efficiencies of joint details and plane elements using three-dimensional models. These details help illustrate the overall thermal performance of a roof or wall as well as the specific heat loss through details per linear metre. 3 As part of its commitment to quality, service and the environment Euroclad operate a Quality Management System approved to BS EN ISO 9001: 2000 and an Environmental Management System approved to ISO 14001.

Introduction SPECIFICATION AND INSTALLATION 4 Amendments to Building Regulations Approved Documents L2 (ADL2) came into effect in April 2002 and impose significant new criteria on the construction of metal buildings. The requirement to reduce CO 2 emissions and produce thermally efficient buildings has a significant effect upon the construction of the building envelope. Essentially, U-values have been reduced for both roof and walls, but more significantly, the method of calculation is now much more rigorous. Complete analysis of the plane elements is now mandatory. The software used to model the detrimental affect of any thermal bridges is now quite sophisticated and therefore gives a much more realistic reflection of the actual thermal performance of the total building envelope. Several different programmes are available (both BRE and Euroclad employ TRISCO) but to be compliant, the model must satisfy BS ISO EN 10211-2. This is the required standard for all compliant three-dimensional thermal models. In a more revolutionary step, the new regulations also require the calculation of the heat loss through all the details of the building envelope. The thermal efficiency of the ridge, eave, gable, window, door junction, cills etc. must all be calculated. Their propensity to create condensation is also evaluated as a result. Two new criteria have been recognised. PSI (ψ ) VALUES The new three-dimensional thermal models not only calculate the U-value on the plane elements, they are also able to produce psi and F-factors for all junctions and details. The psi value reflects the additional heat loss through the detail per linear metre, when compared to the plane elements. The Building Regulations require the heat loss through the details to be included in the evaluation of the building s total thermal performance.

Construction details Introduction There is no need to achieve the lowest possible psi values, it suffices that the efficiency of the details are calculated and can demonstrate compliance with IP17/01 (5.1). CALCULATION OF F FACTORS With the introduction of reduced air leakage requirement there was concern surrounding the possibility of condensation forming on the internal surface surrounding a thermal bridge. The propensity to create condensation is a function of the detail s thermal inefficiency and the temperature/humidity of the environment within the building. Humidity class 1 Building type Storage areas 0.30 2 Offices and shops 0.50 3 Dwellings, residential buildings and schools 0.75 4 Dwellings with high occupancy, sports halls, kitchens, canteens and buildings heated with un-flued gas heaters 5 Special buildings e.g. laundry, brewery and swimming pool Internal humidity class and the external minimum temperature factor necessary to prevent condensation. Minimum F-value 0.80 0.80 Software programmes compliant with BS EN ISO 10211-2 allow calculation of each detail s F-factor. The table above illustrates how knowledge of the building s use and its internal humidity can lead to easy identification of any detail s acceptability. The F-factor is simply compared to the minimum allowable for that classification of building. Dramatic changes in F-factors can be achieved by small alterations in the design. The F-value has only to exceed the minimum requirement. AIR PERMEABILITY The Building Regulations require the testing of the building envelope. Buildings with a gross floor area in excess of 500m 2 must be physically tested. The standard required is: 10 m 3 /h/m 2 at 50 Pascals The Building Regulations specify testing of building air permeability and in that respect the area of the floor is allowed into the calculation. The allowable air loss in cubic metres area of roof and walls and floor multiplied by 10. For example, a building square on plan, with a flat roof, 120m per side and 8m high, the figures would be as follows: 120m x 8m = 960m 2 x 4 (sides) = 3840m 2 120m x 120m = 14400 x 2 (roof and floor) = 28800m 2 Total = 32640m2 So the allowable air loss would be: 326400m 3 /h Test results at BRE have proven that a carefully sealed liner on either a built-up system, or a composite panel, will prove a very effective vapour check. For further details please refer to the section on Sealing of liners in the Euroclad Design and installation recommendations brochure. A copy of the Air Pressure report is to be given to the local authority. 5

Introduction 6 Air permeability tests can be undertaken by the following companies: 1. BRE, Watford Contact: Brian Webb Tel: 01923 664300 2. BSRIA, West Bracknell Contact: David Pickervance Tel: 01344 426511 3. Building Sciences, Wantage Contact: Nick Selves Tel: 01235 835323 4. HRS Services, Sheffield Contact: E Westgate Tel: 0114 2723003 SUMMARY Extensive computer analysis of Euroclad construction details has shown that standard good practice will often achieve compliance. However, all ψ and F-factors must be calculated and checked to ensure compliance. It should be noted that the application of a particular construction detail in a specific building is determined by the requirements of that individual building. Other factors, such as building type, internal environment and general layout may significantly affect detail choice. This, together with consideration of the details from other parts of the structure (perhaps with a different construction) must be taken into account during design, specification and installation, when determining compliance with the Building Regulations. Air permeability of 10 m 3 /h/m 2 at 50 Pascals has been achieved and bettered both in test and actual experience on site. Good detailing, careful choice of materials, close liaison with the manufacturer and specialist contractor and early involvement of all parties in the project design will prove that an L2 compliant building can be achieved very effectively with a metal envelope. Euroclad has a wide range of products including Standing Seam and Secret fix roofing, trapezoidal/ sinusoidal profiles, aluminium fabrications, flashings, powder coating and composite wall panels. Euroclad can offer a full metal building envelope which is truly integrated by design. The following pages illustrate some standard solutions. Many more are available and particular details can be modelled on a project-by-project basis. If you need any help or further clarification please do not hesitate to contact the Euroclad Sales department.

TYPICAL BUILDING Construction details Introduction 2 6 6 7 2 3 8 1 6 7 9 5 4 6 9 11 3 1 1 8 11 10 1 Corner details 18 7 Eaves and gutter details 36 2 Ridge/Hip details 20 8 Door and window head details 38 3 Gable/Verge details 22 9 Door jamb details 40 4 Roof abutment to side details 26 10 Window jamb details 42 5 Roof abutment to end and apron details 30 11 Cill and drip details 44 6 Valley/Parapet gutters and internal hips details 32

Thermal performance of built-up systems THERMAL PERFORMANCE OF BUILT-UP SYSTEMS EUROCLAD PLANE ELEMENTS The depths shown on the following four pages are the minimum depths of insulation required to meet the U-values shown. Greater depths may be installed to suit commercially available spacer systems and quilt sizes. EUROCLAD FLASHINGS DETAILS EUROCLAD TRISCO MODEL CONVENTIONS All external boundary conditions assumed to be @ 0 C and 25 W/m 2 K (When the CEN-rule is toggled to HE). All Internal boundary conditions assumed to be @ 20 C and 7.7 W/m 2 K (When the CEN-rule is toggled to HI_NORML). 8 The flashings details shown from pages 14 to 40 all give guidance on the F and ψ values and these values are also dependant on the U-values of the plane elements to which they are adjacent. For modeling purposes, all roof elements are assumed to be 0.25 U-value and all wall elements are assumed to be 0.35 U-value. Air cavities, where applicable, are modelled as material blocks using the type EQUIMAT, as explained in sections C.6-C.8 in the Trisco Manual. Thermal conductivities of typical material values are given as: (in accordance with the MCRMA Guidance) EUROBAR thermal performance Secret fix EUROBAR Euroclad Secret fix and 1000/19 liner with Eurobar 180mm brackets 1000mm centres U-VALUE 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Euroclad Secret fix and MW5 liner with Eurobar 180mm brackets 1000mm centres U-VALUE 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 EUROBAR thermal performance 1000/32 with MW5 (Roofs) EUROBAR Euroclad 1000/32 and MW5 liner with Eurobar 180mm brackets 1000mm centres (Roof) U-VALUE 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Euroclad 1000/32 and MW5 with Eurobar 200mm brackets 1000mm centres (Roof) U-VALUE 0.26 0.25 0.24 0.23 0.22 0.21 0.20 0.19 0.18 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035

Metals Steel Stainless steel Aluminium Copper Other materials 50 or 60 W/mK 17 W/mK 160 W/mK 380 W/mK Construction details Insulants Glass fibre 0.044/0.040/0.037/ 0.035 W/mK Mineral wool 0.040 W/mK Expanded polystyrene 0.035 W/mK Urethane 0.022 W/mK Thermal performance of built-up systems Timber PVC Polyester resin Polycarbonate 0.14 W/mK 0.17 W/mK 0.20 W/mK 0.20 W/mK 9 Euroclad Secret fix and 1000/19 liner with Eurobar 210mm brackets 1000mm centres U-VALUE 0.24 0.23 0.22 0.21 0.20 0.19 0.18 0.17 0.16 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Euroclad Secret fix and MW5 liner with Eurobar 220mm brackets 1000mm centres U-VALUE 0.24 0.23 0.22 0.21 0.20 0.19 0.18 0.17 0.16 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Euroclad 1000/32 and MW5 liner with Eurobar 220mm brackets 1000mm centres (Roof) U-VALUE 0.24 0.23 0.22 0.21 0.20 0.19 0.18 0.17 0.16 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035

Thermal performance of built-up systems 10 EUROBAR EUROBAR thermal performance 1000/32 with 1000/19 (Roofs) Euroclad 1000/32 and 1000/19 liner with Eurobar 170mm brackets 1000mm centres (Roof) 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) U-VALUE 0.044 0.040 0.037 0.035 Euroclad 1000/32 and 1000/19 liner with Eurobar 180mm brackets 1000mm centres (Roof) U-VALUE 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 0.20 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 EUROBAR thermal performance 1000/32 with 1000/19 (Walls) EUROBAR Euroclad 1000/32 and 1000/19 liner with Eurobar 120mm brackets 1000mm centres (Wall) U-VALUE 0.39 0.38 0.37 0.36 0.35 0.34 0.33 0.32 0.31 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Euroclad 1000/32 and 1000/19 liner with Eurobar 140mm brackets 1000mm centres (Wall) 0.34 0.33 0.32 0.31 0.30 0.29 0.28 0.27 0.26 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) U-VALUE 0.044 0.040 0.037 0.035 EUROBAR EXTRA thermal performance Secret fix EUROBAR EXTRA Euroclad Secret fix and MW5 liner with Eurobar Extra 185mm brackets 1000mm centres U-VALUE 0.30 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Euroclad Secret fix and 1000/19 liner with Eurobar Extra 185mm brackets 1000mm centres 0.29 0.28 0.27 0.26 0.20 0.24 0.23 0.22 0.21 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) U-VALUE 0.044 0.040 0.037 0.035

Euroclad 1000/32 and 1000/19 liner with Eurobar 210mm brackets 1000mm centres (Roof) 0.24 0.23 0.22 0.21 0.20 0.19 0.18 0.17 0.16 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) U-VALUE 0.044 0.040 0.037 0.035 Construction details Valley Thermal / parapet performance gutters of and built-up internal systems hips 11 Euroclad 1000/32 and 1000/19 liner with Eurobar 150mm brackets 1000mm centres (Wall) U-VALUE 0.32 0.31 0.30 0.29 0.28 0.27 0.26 0.25 0.24 0.23 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.038 0.037 0.035 Euroclad 1000/32 and 1000/19 liner with Eurobar 160mm brackets 1000mm centres (Wall) U-VALUE 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Euroclad Secret fix and MW5 liner with Eurobar Extra 200mm brackets 1000mm centres U-VALUE 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 0.20 0.19 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Euroclad Secret fix and 1000/19 liner with Eurobar Extra 200mm brackets 1000mm centres U-VALUE 0.27 0.26 0.25 0.24 0.23 0.20 0.21 0.20 0.19 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035

Thermal performance of built-up systems 12 EUROBAR EXTRA EUROBAR EXTRA thermal performance 1000/32 Euroclad 1000/32 and 1000/19 liner with Eurobar Extra 185mm brackets 1000mm centres U-VALUE 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Euroclad 1000/32 and MW5 liner with Eurobar Extra 185mm brackets 1200mm centres U-VALUE 0.29 0.28 0.27 0.26 0.25 0.24 0.23 0.22 0.21 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 EUROBAR EXTRA MAST thermal performance Secret fix EUROBAR EXTRA MAST Euroclad Secret fix and MW5 liner Eurobar Extra 280mm Mast 1200mm centres U-VALUE 0.20 0.19 0.18 0.17 0.16 0.15 0.14 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 EUROBAR EXTRA MAST thermal performance 1000/32 EUROBAR EXTRA MAST Euroclad 1000/32 and MW5 liner with Eurobar Extra 240mm Mast 1200mm centres U-VALUE 0.24 0.23 0.22 0.21 0.20 0.19 0.18 0.17 0.16 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035

Euroclad 1000/32 and 1000/19 liner with Eurobar Extra 200mm brackets 1000mm centres U-VALUE 0.27 0.26 0.25 0.24 0.23 0.22 0.21 0.20 0.19 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Construction details Euroclad 1000/32 and MW5 liner with Eurobar Extra 200mm brackets 1200mm centres U-VALUE 0.27 0.26 0.25 0.24 0.25 0.22 0.21 0.20 0.19 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 SPAN (m) 0.044 0.040 0.037 0.035 Thermal performance of built-up systems 13

Built-up roof constructions BUILT-UP ROOF CONSTRUCTIONS TRAPEZOIDAL SHEETING BUILT-UP CONSTRUCTION (ROOF) 0.25 U-VALUE 32/1000 FORWARD PROFILE PS031.dwg Euroclad 32/1000 Forward profile 0.7mm gauge 14 Bracket and support bar (170mm) 170mm (minimum) 0.040k-value insulation quilt Euroclad 19/1000 liner (steel) sealed as per U-value: 0.25 W/m 2 K. Based on purlin/rail centres of 1800mm.

Construction details Built-up roof constructions 15

Built-up Valley / parapet wall constructions gutters and internal hips BUILT-UP WALL CONSTRUCTIONS TRAPEZOIDAL SHEETING OVER-RAIL SYSTEM MINERAL FIBRE INSULANT (FIREWALL see Euroclad Firewalls brochure for more details) 7FW71.dwg 16 Profiled mild steel internal liner panel 0.4mm gauge (min) Sheeting rail Self-drill, self-tapping fixings Euroclad profiled mild steel external cladding 0.5mm gauge (min) Self-drill, self-tapping fixing 120mm (minimum) 0.040λ insulation quilt Bracket and support bar (120mm)

Construction details Built-up wall constructions 17

Corner details CORNER DETAILS TRAPEZOIDAL SHEETING INTERNAL BUILT-UP CORNER PS002.dwg Euroclad liner sealed as per manufacturer s recommendations Euroclad liner flashing 18 9 x 3mm mastic sealant Euroclad external flashing 9 x 3mm mastic sealant Euroclad liner sealed as per F-factor: 0.96, ψ value: 0.02 W/mK. TRAPEZOIDAL SHEETING EXTERNAL BUILT-UP CORNER PS003.dwg Euroclad liner sealed as per 9 x 3mm mastic sealant 9 x 3mm mastic sealant Euroclad liner flashing Euroclad liner sealed as per Euroclad external flashing F-factor: 0.95, ψ value: 0.02 W/mK.

Construction details Corner details TRAPEZOIDAL SHEETING WALL ABUTMENT TO MASONRY PS001.dwg Euroclad liner sealed as per manufacturers recommendations Euroclad liner flashing 19 Masonry 9 x 3mm mastic sealant Euroclad external flashing F-factor: 0.92, ψ value: 0.03 W/mK.

Ridge/Hip details RIDGE/HIP DETAILS SECRET FIX SF500 RIDGE/HIP (FLASHINGS) SF112.dwg Euroclad Secret fix SF500 ridge closure with filler Secret fix SF500 0.7mm Steel 500 Module Euroclad 0.7mm flashing 20 Sheet turned up Sheet turned up Euroclad liner sheet sealed as per Euroclad 0.7mm liner flashing Fillers sealed with gun grade mastic Euroclad liner sheet sealed as per F-factor: 0.98, ψ value: 0.00 W/mK. TRAPEZOIDAL SHEETING RIDGE/HIP (FLASHINGS) PS017.dwg Fillers sealed with gun grade mastic Euroclad ridge flashing Profiled filler Profiled filler Euroclad liner sheet sealed as per Euroclad liner flashing sealed and fixed to liner Euroclad liner sheet sealed as per F-factor: 0.98, ψ value: 0.00 W/mK.

Construction details Ridge/Hip details TRAPEZOIDAL SHEETING RIDGE (CRANKS) PS016.dwg Euroclad ridge cranks Euroclad liner cranks sealed and fixed to liner 21 Euroclad liner sheet sealed as per Euroclad liner sheet sealed as per F-factor: 0.98, ψ value: 0.00 W/mK.

Gable/Verge details GABLE/VERGE DETAILS SECRET FIX SF500 TO BUILT-UP SYSTEM GABLE/VERGE SF111.dwg Secret fix SF500 0.7mm steel 500 module Secret fix SF500 verge section Sealed with 9 x 3mm Butyl mastic 22 Euroclad liner sealed as per manufacturer s recommendations Euroclad 0.7mm Corus Colorcoat cap flashing Flashings available to match the exterior finish Filler Cleader rail Filler sealed with gun grade mastic Sealed with 9 x 3mm Butyl mastic Euroclad liner sealed as per manufacturer s recommendations F- factor: 0.96, ψ value: 0.03 W/mK. TRAPEZOIDAL SHEETING STANDARD GABLE/VERGE PS013.dwg 9 x 3mm mastic sealant Euroclad liner sealed as per Euroclad Barge flashing Cleader rail 9 x 3mm Butyl mastic Profiled filler 9 x 3mm Butyl mastic sealant Filler sealed with gun grade mastic Euroclad liner sealed as per F-factor: 0.96, ψ value: 0.02 W/mK.

Construction details Gable/Verge details 23

Mono ridge details MONO RIDGE DETAILS SECRET FIX SF500 TO BUILT-UP WALL MONO RIDGE SF108.dwg Secret fix SF500 0.7mm Euroseam Secret fix SF500 ridge closure with filler Euroclad mono ridge flashing Sheet turned up 24 Filler Euroclad liner sealed as per manufacturer s recommendations Euroclad Internal flashing Fillers sealed with gun grade mastic Euroclad liner sealed as per F-factor: 0.96, ψ value: 0.03 W/mK. TRAPEZOIDAL SHEETING MONO RIDGE PS030.dwg Euroclad mono ridge flashing Profiled filler Profiled filler Euroclad liner sealed as per Euroclad liner flashing Filler sealed with gun grade mastic Euroclad liner sealed as per F-factor: 0.95, ψ value: 0.03 W/mK.

Construction details Mono ridge details 25

Roof abutment to side details ROOF ABUTMENT TO SIDE DETAILS SECRET FIX SF500 TO BUILT-UP SHEETING ROOF ABUTMENT TO SIDE WALL SF107.dwg Filler 26 Secret fix SF500 0.7mm Euroclad flashing sealed with 9 x 3mm Butyl mastic Euroclad Secret fix verge section Fillers sealed with gun grade mastic Euroclad liner flashing Euroclad liner sheet sealed as per Euroclad liner sheet sealed as per manufacturer s recommendations Sealed with 9 x 3mm mastic sealant F-factor: 0.96, ψ value: 0.03 W/mK. TRAPEZOIDAL SHEETING ROOF ABUTMENT TO BUILT-UP SIDE WALL PS014.dwg Euroclad liner sealed as per Manufacturer s recommendations Euroclad apron flashing Profiled filler Euroclad liner flashing Euroclad liner sheet sealed as per Filler sealed with gun grade mastic 9 x 3mm mastic sealant F-factor: 0.96, ψ value: 0.02 W/mK.

Construction details SECRET FIX SF500 TO MASONRY ROOF ABUTMENT TO END WALL SF113.dwg Roof abutment to side details Euroclad flashing chased into masonry Sealed with 9 x 3mm Butyl mastic Euroclad Secret fix verge section Secret fix SF500 0.7mm 27 Euroclad liner sheet sealed as per manufacturer s recommendations Euroclad 0.7mm liner Corus Colorcoat flashing Flashings available to match the exterior finish Sealed with 9 x 3mm Butyl mastic F-factor: 0.97, ψ value: 0.02 W/mK.

Roof abutment to side details ROOF ABUTMENT TO SIDE DETAILS TRAPEZOIDAL SHEETING TO MASONRY ROOF ABUTMENT PS012.dwg Euroclad flashing chased into masonry Euroclad external flashing 9 x 3mm mastic sealant 28 Masonry Euroclad liner sheet sealed as per Euroclad liner flashing fixed and sealed to masonry F-factor: 0.94, ψ value: 0.02 W/mK. 9 x 3mm mastic sealant

Construction details Roof abutment to side details 29

Roof abutment to end and apron details ROOF ABUTMENT TO END AND APRON DETAILS SECRET FIX SF500 TO MASONRY ROOF APRON TO END WALL SF114.dwg Euroclad flashing chased into masonry Euroclad flashing sealed with 9 x 3mm Butyl mastic Euroclad Secret fix SF500 ridge closure with filler 30 Secret fix SF500 0.7mm Euroclad liner sheet sealed as per manufacturer s recommendations Sheet turned up Euroclad flashing Sealed with 9 x 3mm Butyl mastic Filler sealed with gun grade mastic F-factor: 0.95, ψ value: 0.03 W/mK. TRAPEZOIDAL SHEETING BUILT-UP-SYSTEM ROOF APRON TO END WALL PS015.dwg Euroclad liner sealed as per Manufacturer s recommendations Profiled filler Euroclad apron flashing Euroclad liner flashing Profiled filler Euroclad liner sheet sealed as per Manufacturer s recommendations Filler se aled with gun grade mastic F-factor: 0.96, ψ value: 0.02 W/mK.

Construction details Roof abutment to end and apron details 31

Valley/Parapet gutters and internal hips VALLEY/PARAPET GUTTERS AND INTERNAL HIPS SECRET FIX SF500 VALLEY GUTTER/INTERNAL HIP SF105.dwg Sheet turned down Euroclad closure flashing Secret fix SF500 0.7mm Sheet turned down 32 Euroclad liner sheet sealed as per manufacturer s recommendations Euroclad Secret fix SF500 filler Insulated gutter (45mm at 0.020λ) Filler sealed with gun grade mastic Euroclad liner sheet sealed as per manufacturer s recommendations 300mm sole F-factor: 0.54, 45mm insulation: ψ value: 1.76 W/mK. 600mm sole F-factor: 0.54, 45mm insulation: ψ value 1.82 W/mK. TRAPEZOIDAL SHEET VALLEY GUTTER PS019.dwg Euroclad closure flashing Profiled filler Profiled filler Euroclad liner sheet sealed as per manufacturer s recommendations Euroclad liner sheet sealed as per manufacturer s recommendations Filler sealed with gun grade mastic Insulated gutter (45mm at 0.020λ) Filler sealed with gun grade mastic 300mm sole F-factor: 0.54, 45mm insulation: ψ value: 1.76 W/mK. 600mm sole F-factor: 0.54, 45mm insulation: ψ value 1.82 W/mK.

TRAPEZOIDAL SHEET VALLEY GUTTER/INTERNAL HIP Construction details PS018.dwg Valley/Parapet gutters and internal hips Profiled filler Euroclad gutter flashing Profiled filler 33 Filler sealed with gun grade mastic Euroclad liner sealed as per manufacturer s recommedations Euroclad liner flashing sealed and fixed to liner Filler sealed with gun grade mastic F-factor: 0.97, ψ value 0.01 W/mK. PARAPET GUTTER SECRET FIX SF500 TO PROFILED SHEETING SF106.dwg Euroclad cap flashing Sheet turned down Euroclad Secret fix SF500 filler Secret fix SF500 0.7mm Euroclad closure flashing Euroclad liner sheet sealed as per Insulated gutter (31mm at 0.020λ) Filler sealed with gun grade mastic Euroclad liner sheet sealed as per F-factor: 0.54, ψ value: 1.09 W/mK.

Valley/Parapet gutters and internal hips VALLEY/PARAPET GUTTERS AND INTERNAL HIPS TRAPEZOIDAL SHEETING EAVES GUTTER AT PARAPET PS021.dwg Euroclad parapet cap flashing Profiled filler Filler sealed with gun grade mastic Profiled filler 34 Euroclad closure flashing Euroclad gutter drip flashing 9 x 3mm mastic sealant Euroclad liner sheet sealed as per manufacturer s recommendations Insulated gutter (45mm at 0.020λ) Euroclad liner sheet sealed as per Filler sealed with gun grade mastic F-factor: 0.54, ψ value: 1.10 W/mK. TRAPEZOIDAL SHEETING CURVED EAVES GUTTER PS026.dwg Profiled filler Euroclad closure flashing Euroclad gutter drip flashing Euroclad liner sheet sealed as per Filler sealed with gun grade mastic Insulated gutter (45mm at 0.020λ) Filler sealed with gun grade mastic Euroclad liner sheet sealed as per These calculations are based on traditional valley gutters. Information on improved results can be obtained from the Euroclad Technical Department. 300mm sole F-factor: 0.54, 45mm insulation: ψ value: 1.76 W/mK. 600mm sole F-factor: 0.54, 45mm insulation: ψ value 1.82 W/mK.

Construction details Valley/Parapet gutters and internal hips 35

Eaves gutter details EAVES GUTTER DETAILS SECRET FIX SF500 TO TRAPEZOIDAL SHEETING EAVES GUTTER SF110.dwg Secret fix SF500 to be turned down approximately 10 Care to be taken to avoid tearing Secret fix SF500 filler Secret fix SF500 0.7mm Eaves drip 50 x 25 x 3mm angle Closure rivetted to liner Rail and bracket system 36 Euroclad gutter Filler sealed with gun grade mastic Euroclad liner sheet sealed as per Manufacturer s recommendations Profiled filler Gutter support strap 6mm, 50mm wide at 1m centres Internal flashing sealed using cross-linked Butyl sealant F-factor: 0.96, ψ value: 0.02 W/mK. TRAPEZOIDAL SHEETING EAVES GUTTER PS022.dwg Euroclad gutter arm Euroclad liner sealed as per Filler sealed with gun grade mastic Euroclad liner flashing Eaves beam Profiled filler Euroclad eaves flashing Euroclad eaves gutter Euroclad liner sealed as per F-actor: 0.96, ψ value: 0.02 W/mK.

Construction details Eaves gutter details TRAPEZOIDAL SHEETING EAVES GUTTER WITH SOFFIT PS035.dwg Filler sealed with gun grade mastic Gutter support bracket Profiled fillers Euroclad 19/1000 liner sealed as per manufacturer s recommendations Thermal barrier Euroclad eaves gutter 37 20/1066 forward soffit Euroclad flashing 0.7mm Euroclad eaves closure flashing 100 x 50 x 1.6 galvanised angles F-factor: 0.68, heat loss: 0.42 WK.

Door and window head details DOOR AND WINDOW HEAD DETAILS TRAPEZOIDAL SHEETING DOOR HEAD PS007.dwg Euroclad liner sealed as per Filler sealed with gun grade mastic 40mm 38 Mineral fibre quilt infill Filler Euroclad closure flashing 20mm Euroclad flashing sealed to panel and steelwork with 9 x 3mm Butyl mastic Packing as required Euroclad two-piece cill flashing Packing Typical door F-factor: 0.72, ψ value: 0.42 W/mK. TRAPEZOIDAL SHEETING VEHICLE ACCESS DOOR HEAD PS006.dwg as per Filler sealed with gun grade mastic Mineral fibre quilt infill Profiled filler 40mm 20mm Euroclad liner sealed as per Euroclad flashing sealed to panel and steelwork with 9 x 3mm Butyl mastic Euroclad closure flashing Packing Euroclad two-piece cill flashing Typical door F-factor: 0.72, ψ value: 0.47 W/mK.

TRAPEZOIDAL SHEETING WINDOW HEAD PS008.dwg Construction details Door and window head details sealed as per Manufacturer s recommendations Euroclad liner sealed as per Filler sealed with gun grade mastic 40mm Mineral fibre quilt infill Profiled filler Euroclad closure flashing 20mm Euroclad flashing sealed to panel and steelwork with 9 x 3mm Butyl mastic Packing as required 39 Euroclad two-piece cill flashing Packing Typical window F-factor: 0.72, ψ value: 0.45 W/mK.

Door jamb details DOOR JAMB DETAILS TRAPEZOIDAL SHEETING VEHICLE ACCESS DOOR JAMB PS029.dwg Euroclad 0.7mm steel flashing 40 Typical door Packing as required Quilt infill Euroclad liner sealed as per Euroclad flashing sealed to liner and steelwork with 9 x 3mm Butyl mastic F-factor: 0.92, ψ value: 0.11 W/mK. TRAPEZOIDAL SHEETING DOOR JAMB PS004.dwg Euroclad 0.7mm steel flashing 9 x 3mm mastic sealant Typical door Packing as required Euroclad liner sealed as per manufacturer s recommendations Quilt infill Euroclad flashing sealed to liner and steelwork with 9 x 3mm Butyl mastic F-factor: 0.85, ψ value: 0.24 W/mK.

Construction details 41

Window jamb details WINDOW JAMB DETAILS TRAPEZOIDAL SHEETING WINDOW JAMB PS005.dwg Euroclad 0.7mm steel flashing 42 Typical window 20mm Euroclad liner sealed as per manufacturer s recommendations Packing as required Quilt infill Euroclad flashing sealed to liner and steelwork with 9 x 3mm Butyl mastic F-factor: 0.88, ψ value: 0.18 W/mK.

Construction details Window jamb details 43

Cill and drip details CILL AND DRIP DETAILS TRAPEZOIDAL SHEETING WINDOW CILL PS010.dwg Typical window Packing 44 Euroclad flashing Profiled filler Packing as required Mineral fibre quilt infill Filler sealed with gun grade mastic Euroclad flashing sealed to panel and steelwork with 9 x 3mm Butyl mastic Euroclad liner sealed as per F-factor: 0.82, ψ value: 0.25 W/mK. TRAPEZOIDAL SHEETING OVERHANGING DRIP PS011.dwg Euroclad liner sealed as per Profiled filler Filler sealed with gun grade mastic Euroclad liner flashing fixed and sealed to floor 150mm Euroclad drip flashing Euroclad closure flashing F-factor: 0.94, ψ value: 0.00 W/mK.

Construction details Cill and drip details 45

Corus Colorcoat products and services 46 Corus Colorcoat HPS200 and Colorcoat Prisma pre-finished steel in Blue, Sirius and Goosewing Grey. Corus Colorcoat HPS200 pre-finished steel in Augusta Green.

COLORCOAT PRODUCTS AND SERVICES Construction details To ensure the long-term performance and Confidex Guarantee appearance of the building, it is important that the pre-finished steel product is specified alongside the Offers the most comprehensive guarantee for cladding system. pre-finished steel products in Europe and provides peace of mind for up to 30 years. Unlike other Corus Colorcoat products and services guarantees, Confidex covers cut edges for the entirety of the guarantee period and does not require mandatory The Colorcoat brand provides the recognised mark annual inspections. of quality and metal envelope expertise exclusively from Corus. Over the course of 40 years Corus has Confidex Sustain developed a range of technically leading Colorcoat pre-finished steel products which have been Provides a combined guarantee which covers the comprehensively tested and are manufactured to the durability of the Colorcoat pre-finished steel product highest quality standards. These are supported by a and makes the pre-finished steel building envelope range of services such as comprehensive guarantees, CarbonNeutral the first in the world. Unavoidable CO 2 colour consultancy and technical support and guidance. emissions from the pre-finished steel cladding system including fixings and insulation, are measured from cradle Colorcoat HPS200 to grave and the impact offset. More than just offsetting, the aim is to encourage specification of the most Exclusive coating technology, superior performance sustainable pre-finished steel products and cladding and the unique Confidex Guarantee make Colorcoat systems. HPS200 the most specified pre-finished steel product in Europe for roof and wall cladding. Now maintenance Colorcoat Building manual free for up to 30 years. Developed in consultation with architects and other Colorcoat Prisma construction professionals, the Colorcoat Building Manual incorporates over 40 years of Colorcoat The ideal choice to deliver eye-catching buildings that expertise. It contains information about sustainable will stand the test of time. Technically and aesthetically development and the creation of a sustainable superior to PVDF (PVF2), Colorcoat Prisma is readily specification. available in the most popular solid and metallic colours. All backed up with the unique Confidex Guarantee Colorcoat Technical papers providing cover for up to 25 years on walls. Working closely with the Corus Colorcoat Centre for the Repertoire Colour Consultancy Building Envelope based at Oxford Brookes University and the Steel Construction Institute, Corus has produced The Repertoire Colour Consultancy can advise on a number of technical papers. These address key colours and colour strategies using a range of standard construction issues such as the creation of an airtight shades, as well as discussing individual bespoke colour building envelope and end of life options for pre-finished requirements. Corus can match almost any shade from steel cladding systems. physical swatches to commonly used references such as RAL, NCS and British Standard and more unusual For more information about Corus Colorcoat standards. products and services visit www.colorcoat-online.com or call the Colorcoat Connection helpline on +44 (0)1244 892434. Corus Colorcoat products and services 47 Colorcoat, Colorcoat Connection, Confidex, Confidex Sustain, HPS200, Prisma and Repertoire are trademarks of Corus.

Notes and contacts NOTES AND CONTACTS 48

Euroclad Limited Wentloog Corporate Park Cardiff CF3 2ER Telephone +44 (0) 29 2079 0722 Facsimile +44 (0) 29 2079 3149 E-mail sales@euroclad.com Internet www.euroclad.com Euroclad (Ireland) Limited Unit 4 Newhall Industrial Estate Naas Co. Kildare Telephone 00 353 (0) 45 435 470 Facsimile 00 353 (0) 45 435 472 Internet www.euroclad.ie The details and information contained in this publication are correct at time of going to press. Euroclad reserves the right to change details and specifications without prior notice. No responsibility is assumed for errors or misinterpretations resulting from the information contained in this publication. Typical construction details are illustrative only and no liability is accepted. All gauges nominal. 1K/6.08