RESOURCE RECYCLING SOLUTIONS LTD Iron House Farm, Lancaster Road, Out Rawcliffe, Preston, Lancashire, PR3 6BP Accident Management Plan Issue 01 Walker Resource Management Ltd - www.walkerom.com
QC Document Title: Accident Management Plan Revision: 01 Date: 31/07/2013 Document Reference: Prepared For: Project Reference: RRS - AMP Resource Recycling Solutions Ltd WRM/PR419/P13 Copyright: Walker Resource Management Ltd 2012 Quality Control Document Author Lauren Briggs Quality Reviewer Ben Brown Date 31/07/2013 Copyright All material on these pages, including without limitation text, logos, icons and photographs, is copyright material of Walker Resource Management Limited. Use of this material may only be made with the express, prior, written permission of Walker Resource Management Limited. This document was produced solely for use by the named contractee to whom the document refers. Walker Resource Management Ltd Churchill House, 90 Boroughgate, Otley, West Yorkshire LS21 1AE Tel: 01943 468138 Fax: 01943 461586 Email: info@walkerom.com Web: www.walkerom.com Company Registration Number: 06656979 VAT Registration Number: 925367802
CONTENTS 1.0 EMERGENCY CONTACTS... 1 2.0 ACCIDENT MANAGEMENT PLAN... 2 i
1.0 EMERGENCY CONTACTS Site Location Details Company Access via Office Phone Resource Recycling Solutions Ltd Access road adjoining Lancaster Road See Mobile Site Mobile Phone 07714 901473 Site Grid reference 341162,444756 Emergency Contacts Emergency Services 999 Local Police 0199 560 7834 Environment Agency Hotline 0800 807 060 Health and Safety Executive 0845 345 0055 Electricity Supplier Eon 0345 052 0000 Local Authority Waste Disposal Contractor Gas Supplier Sewerage Undertaker Lancashire County Council - 0845 053 0000 Fuel Supplier Carrs Billington 0152 4599 333 Company Contacts (Out of hours) Permit Holder NA NA NA Resource Recycling Solutions Ltd Operations Manager Duncan Clitheroe 07714 901476 Managing Director Paul Mathers - 07800 585362 Approval Date of Plan July 2013 Date of Review July 2014 Plan Drawn up by: Miss L Briggs Sign:- Original filed on site Plan Approved by: Ms Julie Gardner Sign:- Original filed on site 1
2.0 ACCIDENT MANAGEMENT PLAN Issue 01 July 2013 Review Date: July 2014 Accident Type Potential for occurrence Anticipated consequences Action to be taken (listed in priority) Plant or equipment failure Diesel spillage Hydraulic leaks Failure of site drainage system Very little likelihood of occurrence. Fuel to be dispensed from a bunded fuel store located on concrete hard-standing. All work is carried out on hard-standing with sealed drainage. The site has no public access. Potentially polluting liquids flow onto hard surfaced area of facility. Stem leak if possible. Isolate using spill control kits or adsorbent material. Inform site manager Monitor leak and prevent any liquid from entering site drains. Drain any contaminated tanks, clean any spillage and dispose of waste as appropriate. Monitor external areas to ensure no further contamination. Record incident Inform EA if necessary. Fire Failure to contain fire water Fuel and oils Buildings Combustible materials Waste materials Chemicals Extremely rare. Potentially polluting liquids flowing onto hard standing area Fire spreading between areas of facility Toxic and polluting smoke Exploding of fuel containers. Wind dispersal of pollutants Review Operations and Management System. Raise alarm on site. Ensure personnel evacuated and accounted for from danger area. If possible to do so safely switch off all electricity/fuel supplies. Ensure all staff are alerted. Call fire service and other emergency services as required. Inform site management. Post member of staff at entrance to site to direct emergency services. Liaise and follow instructions of emergency team making them aware of any hazards on site. Prevent fire waters causing pollution on site. 2
Severe weather Flooding Wind damage Ice/frost Arson/Vandalism Bioaerosols Not very likely due to slope of site leading to drainage containment system and location of site. Site to be as secure as possible. All plant to be locked when not manned. All doors and gates locked outside working hours. The site has no public access. Not very likely that an accident event will occur as the site operates a Bioaerosol Management Plan. Potentially polluting liquids flowing onto and off hardstanding. Depending on the severity of the fire, site critical equipment may have been damaged and no further reception or processing of waste would be undertaken until agreed with the EA. If equipment will be inoperable for extended periods of time, consideration will be given to the removal of material from site until repairs are effectuated. Record incident. Review Operations and Management System. Flooding as per overfilling containment pits. Wind assess damage Mitigate any pollution caused. Inform site manager. Inform EA. Repair damage. Record incident. All of the above Assess damage Mitigate any damage/pollution caused (follow fire plan) Release of potentially polluting airborne particles to environmentally sensitive sites. Inform site management. Inform Police. Inform EA if required. Record incident. Inform site management. Report to EA. Report incident. Review Operations and Management System Review Bioaerosol Management Plan. 3
Walker Resource Management Limited Churchill House, 90 Boroughgate, Otley, West Yorkshire, LS21 1AE Tel: 01943 468138 Fax: 01943 461586 Email: info@walkerom.com Web: www.walkerom.com All material on these pages, including without limitation text, logos, icons and photographs, is copyright material of Walker Resource Management Limited. Use of this material may only be made with the express, prior, written permission of Walker Resource Management Limited. Company Registration Number: 06656979 VAT Registration Number: 925367802